Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Catalogue

Download as pdf or txt
Download as pdf or txt
You are on page 1of 119

Lamborghini Lamborghini in Quality

Caloreclima Italy and certification


nowadays abroad Lamborghini Caloreclima has been one of
the first Italian companies obtaining
Lamborghini Caloreclima has been Lamborghini branches, representatives, prestigious ISO 9001 certification, which is
successfully working in the HEATING, agencies and distributors are present in acknowledged to sole companies
AIR-CONDITIONING and WATER over 35 foreign countries. It is the Italian operating according to full quality
TREATMENT sectors since 1960. Based in tradition that the reference role of the principles. Furthermore, EC standard
Dosso (FE) since 1970, Lamborghini company is the installer. approval for the products concerned has
Caloreclima’s premises cover an overall A network of agents, assistance centres been obtained.
area of 52,000 square metres, 25,000 of and Lamborghini Topclima being
which being roof covered. widespread everywhere, assure careful
The production, operated according to control of the whole national territory,
advanced logistical mechanization systems, providing the users with proper sales and
is managed in compliance with ISO 9001 after-sales assistance.
quality standards. High flexibility of the
production cycles is allowed, thus
guaranteeing fast industrialization of the
products designed.

1
Proposte
Lamborghini:
Continual
innovation
Lamborghini Caloreclima Company
steadily engages itself in the search for
technical solutions aimed at introducing
innovations into its products.
Lamborghini supplies a brand-new range
of products capable of meeting the
market’s needs, these becoming more and
more demanding.
Here is the philosophy adopted by
“Proposte Lamborghini 2004”.
You will find below the most attractive
news of this edition.
Enjoy your choice!

Quality
above all
Lamborghini is renowned all over the
world for the high quality featuring its
products, which are type approved in
most countries.

Innovations

2
Index

Steel boilers
Condensing stainless steel boilers
Steel boilers

Cast iron boilers

Air heaters
Gas “Wall-hung” air heaters
“Industrial” air heaters
Box zone

Condensing gas wall hung boilers, modulars thermic system


Condensing gas wall hung boiler
Gas condensing modulars thermic system
Gas wall hung boiler

Standing gas boilers, gas water heaters


Standing gas boilers
Instantaneous water heaters
Storage water heaters
Box zone

Hot water storages, regulation temperature system, radiators


Hot water storages tank
temperature regulation systems
Alluminium radiators

3
Water treatment system
Water softeners
Filters
Dosagers pump
Polifosphate dosagers

Accessories

4
High-efficiency steel boilers

Condensation gas steel boilers


SILVER S - SILVER BS
SILVER
“superposed” SILVER
High-efficiency steel boilers
NEINOX BT/G
NEINOX BT
NEINOX
MINIA R - MINIA CI
MINIA CB
MINIA N CBX
MEGA PREX BT
MEGA PREX
MEGA PREX SL
DUO PREX

In compliance with:
DIRECTIVE 90/396/EEC ON GAS APPLIANCES
DIRECTIVE L.V. 72/23/EEC (Act No. 791 of 18/10/77)
EFFICIENCY DIRECTIVE 92/42/EEC

SILVER (S-BS)
SILVER
SILVER “sovrap.”
NEINOX BT/G
NEINOX BT
NEINOX
MINIA R-MINIA CI
MINIA CB
MINIA N CBX
MEGA PREX BT
MEGA PREX
MEGA PREX SL
DUO PREX
13,7 22 29,9 30,5 31 31,7 70 93 100 105 150 186 232 300 407 581 1162 2907
kW
5
Condensation gas steel boilers

¥SILVER S - SILVER BS
– Ultra high-efficiency stainless steel condensation proof boiler for
heating (SILVER S) and hot sanitary water heating and supply (SILVER
BS).
- Ideal for low-temperature system operation.
- Boiler shell in stainless steel AISI 316 Ti.
- Flame injection wet bottom cylindrical furnace
- Flues made up of plates being printed on the inner surface whose
special corrugated shape increases turbulence thus allowing
condensation.
- Low NOx emissions in the environment.
- Operation through gas blown burners.

- 120 Lt. enamelled steel boiler, covered with polyurethane (SILVER


BS).
- Heat loss preventing high-thickness insulation.
- Instruments for unit control and adjustment.
- 14 Lt. Heating circuit expansion tank (SILVER BS).
- Circulators on the sanitary (SILVER BS) and on the heating circuit.
- IP 40 Protection degree.

¥ Maintenance 600 865

– Maintenance is made simple thanks to easy accessibility to internal SILVER

components.
40

Ø80
¥ Certification
850

– SILVER boilers are EC type approved.


65

Ø80
930

SILVER 31 S

600 865

SILVER

40

Ø80
65
1255

Ø80

Combustion path Detail of the STAINLESS STEEL


Along the flue gas plates AISI 316 Ti flue gas plates
930

SILVER 31 BS

Connections: see template on page 112.

Boiler Furnace power Useful efficiency Maximum pressure Power voltage Hot sanitary Weight
type a 50/30°C a 80/60°C water supply
min./max. min./max. bar
kW kcal/h % % risc. sanit. V/Hz l/min. Kg
SILVER 31 S 14÷ 30,8 12.100÷ 26.500 108,5/107 97,8/97 3 - 230/50 - 158
SILVER 31 BS 14÷ 30,8 12.100÷ 26.500 108,5/107 97,8/97 3 6 230/50 12,5 205

Boiler Burner Boiler Useful power 50/30°C Useful power 80/60°C


code type type kW kcal/h kW kcal/h
00705170 FIME 5 S-E SILVER 31 S 15,2÷ 33 13.100÷ 28.400 13,7÷ 29,9 11.800÷ 25.700
00705190 FIME 5 S-E SILVER 31 BS 15,2÷ 33 13.100÷ 28.400 13,7÷ 29,9 11.800÷ 25.700

6
Condensation gas steel boilers

¥SILVER
– Ultra high-efficiency boiler.
- Boiler shell in stainless steel AISI 316 Ti.
- Flame injection wet bottom cylindrical furnace
- Flues made up of plates being printed on the inner surface whose
special corrugated shape increases turbulence thus allowing
condensation.
- Ideal for low-temperature system operation.
- Low NOx emissions in the environment.
- Operation through gas blown burners.
- Heat loss preventing high-thickness insulation.
- External instrument panel for unit control and adjustment.

¥ Maintenance
– Maintenance is made simple thanks to easy accessibility to internal
components.

¥ Certification
– SILVER boilers are EC type approved.

¥ Hydraulic connections
a6 a1
160

a1 System delivery DN 50 (mod. 44÷ 80) and DN 65 (mod. 110÷ 150)


a2 Medium temperature system return DN 50 (mod. 44÷ 80) and DN S I LV E R CALORECLIMA

Øi 151
65 (mod. 110÷ 150) a3
a3 Low temperature system return DN 50 (mod. 44÷ 80) and DN 65
1014

Ø1

900
881
(mod. 110÷ 150) 30 a4
a2
a4 System feeding/discharge inlet Ø _”
530

503
a5 Condensation discharge Ø _”

174
a6 Temperature control pocket a5

126
680 785
746 1430
1462

SILVER 44 ÷ SILVER 80

a6 a1
160

S I LV E R CALORECLIMA

Øi 181
a3
1114

Ø1

1000
980
45 a4
a2
580

553
174

a5
126

780 785
Combustion path Detail of the STAINLESS STEEL 846 1723
along the flue gas plates AISI 316 Ti flue gas plates 1755

SILVER 110 - SILVER 150

Boiler Furnace power Useful efficiency Maximum Power voltage Weight


type a 50/30°C a 80/60°C heating pressure
min./max. min./max.
kW kcal/h % % bar V/Hz Kg
SILVER 44 22,5÷ 45,3 19.300÷ 39.000 108,5/107 97,8/97 5 230/50 182
SILVER 60 30,7÷ 61,8 26.400÷ 53.100 108,5/107 97,8/97 5 230/50 184
SILVER 80 40,9÷ 78 35.200÷ 67.080 108,5/107 97,8/97 5 230/50 184
SILVER 110 56,2÷ 114 48.400÷ 98.000 108,5/106 97,8/96,5 5 230/50 223
SILVER 150 76,7÷ 155,4 66.000÷ 133.700 108,5/105 97,8/96,5 5 230/50 230

Boiler Burner Boiler Useful power 50/30°C Useful power 80/60°C


code type type kW kcal/h kW kcal/h
00705210 EM 6-E.D1 SILVER 44 24,4÷ 48,5 21.000÷ 41.700 22÷ 44 18.900÷ 37.800
00705220 EM 9/2-E.D3 SILVER 60 33,3÷ 66,2 28.600÷ 56.900 30÷ 60 25.800÷ 51.600
00705230 EM 9/2-E.D3 SILVER 80 44,4÷ 83,5 38.200÷ 71.810 40÷ 75,6 34.400÷ 65.016
00705240 EM 16/2-E.D4 SILVER 110 61÷ 120,8 52.500÷ 103.900 55÷ 110 47.300÷ 94.600
00705251 EM 18/2-E.D6 SILVER 150 83,2÷ 163,3 71.600÷ 140.400 75÷ 150 64.500÷ 129.000

7
Condensation gas steel boilers

¥SILVER boilers Superposed


– Ultra high-efficiency boiler.
- 2 boiler shells in stainless steel AISI 316 Ti.
- Flame injection wet bottom cylindrical furnaces.
- Flues made up of plates being printed on the inner surface whose
special corrugated shape increases turbulence thus allowing
condensation.
- Ideal for low-temperature system operation.
- Low NOx emissions in the environment.
- Operation through gas blown burners.
- Heat loss preventing high-thickness insulation.
- External instrument panel for unit control and adjustment.
- The boiler is fitted with hydraulic manifolds for connecting the 2 boiler
shells.

¥ Maintenance
– Maintenance is made simple thanks to easy accessibility to internal
components.

¥ Certification
– SILVER boilers are EC type approved.

200 200
a6 a8 a6 a7 a1

S I LV E R CALORECLIMA

¥ Hydraulic connections
Øi 181

a1 System delivery DN 65
a2 Medium temperature system Ø1
45
return DN 65 a4

a3 Low temperature system return


2203

2089
DN 65 S I LV E R CALORECLIMA

a6 a5
1670

1642
Øi 181

a4 System feeding/discharge inlet Ø a3


1263

_” Ø1
980

45
a5 Condensation discharge Ø _” a4
388
580

553

a6 Temperature control pocket


174

a7 Bulb holding pocket Ø _”


a5 a2
126

a8 Instrument coupling Ø 1” 785 780


1789 185 846
2244

Boiler Furnace power Useful efficiency Maximum Power voltage Weight


type a 50/30°C a 80/60°C heating pressure
min./max. min./max.
kW kcal/h % % bar V/Hz Kg
SILVER 200 102,2÷ 207,3 87.900÷ 178.300 108,5/106 97,8/96,5 5 230/50 471
SILVER 250 127,8÷ 259 109.900÷ 222.800 108,5/106 97,8/96,5 5 230/50 471
SILVER 300 153,4÷ 310,9 131.900÷ 267.300 108,5/105 97,8/96,5 5 230/50 485

Boiler 2 burners Boiler Useful power 50/30°C Useful power 80/60°C


code type type kW kcal/h kW kcal/h
00705260 EM 16/2-E.D4 SILVER 200 110,9÷ 219,8 95.400÷ 189.000 100÷ 200 86.000÷ 172.000
00705271 EM 18/2-E.D6 SILVER 250 138,7÷ 274,5 119.300÷ 236.100 125÷ 250 107.500÷ 215.000
00705281 EM 18/2-E.D6 SILVER 300 166,4÷ 326,4 143.100÷ 280.700 150÷ 300 129.000÷ 258.000

8
High-efficiency steel boilers

¥NEINOX BT/G
Ultra high-efficiency and polluting emissions lowered
to the minimum
– Ideal boilers for small-size buildings heating.
- Low variable temperature boilers.
- Ultra low NOx emissions in the environment.
- Operation through low NOx emissions light oil burner ECO LN.
- Steel boiler shell with flame injection wet bottom cylindrical furnaces.
- Heat resistant protection of the combustion chamber allowing easy
control of the flue gas temperature.
G
- Two ultra thick steel concentric flues enabling even distribution of heat
and avoiding condensation.
- Heat loss preventing high-thickness insulation.
- Standard special front insulation.
- Door opening adjustable arm.
- Stainless steel turbolators.
- External instrument panel for unit control and adjustment.
- Control thermometer pocket.

¥ Installation and Maintenance


– A burner can be fitted onto the boiler plate.
- Maintenance is made simple thanks to easy accessibility to internal
components by means of the adjustable arm.

¥ Optional accessories
– For optional accessories intended for NEINOX BT/G boilers see page 85.

¥ Certification
– NEINOX BT/G boiler is EC type approved. 160

a1

Opening arm Ø 120


a4
670

a2
400
273

a3

Concentric gas flue pipes 860 580

Boiler Furnace power Useful efficiency Maximum Power voltage Heating Heating Boiler Flue Weight
type a 50/30°C a 80/60°C heating pressure delivery return discharge connection
kW kcal/h 100 % 100 % 30 % bar V/Hz Ø a1 Ø a2 Ø a3 Ø a4 Kg
NEINOX BT 31G 34 29.240 93 91,6 91,2 3 230/50 1” 1” 1” 30 145

Boiler Boiler Boiler Useful power


code type type kW kcal/h
00703491 ECO 4 LN NEINOX BT 31G 31 26.600

9
High-efficiency steel boilers

¥NEINOX BT
– Ideal boilers for small-size buildings heating.
- Low variable temperature boilers for maximum efficiency.
- Ultra low NOx emissions in the environment.
- Operation through of low light oil or gas burners.
- Steel boiler shell with flame injection wet bottom cylindrical furnaces.
- Heat resistant protection of the combustion chamber allowing to keep
high flue gas temperature.
- Two ultra thick steel concentric flues enabling even distribution of heat
and avoiding condensation.
- Heat loss preventing high-thickness insulation.
- Standard special front insulation.
- Door opening adjustable arm.
- Stainless steel turbolators.
- External instrument panel for unit control and adjustment.
- Control thermometer pocket.
- NEINOX BT boilers can be combined with BITHERM boilers.

¥ Installation and Maintenance


– A burner can be fitted onto the boiler plate.
- Maintenance is made simple thanks to easy accessibility to internal
components by means of the adjustable arm.

¥ Optional accessories
– For optional accessories intended for NEINOX BT boilers see page 85.

¥ Certification
– NEINOX BT boilers are EC type approved.
160

a1

Opening arm Ø 120


a4
670

a2
400
273

a3

Concentric gas flue pipes 860 580

Boiler Furnace power Useful efficiency Maximum Power voltage Heating Heating Boiler Flue Weight
type a 50/30°C a 80/60°C heating pressure delivery return Discharge connection
kW kcal/h 100 % 100 % 30 % bar V/Hz Ø a1 Ø a2 Ø a3 Ø a4 Kg
NEINOX BT 31 34 29.240 93 91,6 91,2 3 230/50 1” 1” 1” 30 145

Boiler Boiler Useful power


code type kW kcal/h
00902141 NEINOX BT 31 31 26.600

10
High-efficiency steel boilers

¥NEINOX
– Ideal boilers for small- and medium-size buildings heating.
- Steel boiler shell with flame injection wet bottom cylindrical furnaces.
- Ultra low NOx emissions in the environment.
- Operation through of low light oil or gas burners.
- Heat loss preventing high-thickness insulation.
- Standard special front insulation.
- Door opening adjustable arm.
- Stainless steel turbolators.
- Ultra thick steel flues.
- External instrument panel for unit control and adjustment.
- Control thermometer pocket.
- NEINOX boilers can be combined with BITHERM boilers.

¥ Installation and Maintenance


– A burner can be fitted onto the boiler plate.
- Maintenance is made simple thanks to easy accessibility to internal
components by means of the adjustable arm.

¥ Optional accessories
– For optional accessories intended for NEINOX boilers see page 85.

¥ Certification
– NEINOX boilers are EC type approved.

160

a1
a4

Ø 120
E

a2
C

a3
B

Insulation D A

Boiler Furnace power Useful efficiency Maximum Power Heating Heating Boiler Flue A B C D E Weight
type % heating pressure voltage delivery return discharge connection
kW kcal/h 100 % 30 % bar V/Hz Ø a1 Ø a2 Ø a3 Ø a4 mm. mm. mm. mm. mm. Kg
NEINOX 22 24 20.700 91,7 91,4 3 230/50 1” 1” 1” 127 525 280 460 780 620 110
NEINOX 31 34 29.240 91,6 91,2 3 230/50 1” 1” 1” 127 580 300 500 810 670 130
NEINOX 40 44 37.840 91,3 91,1 3 230/50 1 1/4” 1 1/4” 1” 178 660 320 550 920 760 160
NEINOX 50 55 47.300 91,2 91 3 230/50 1 1/4” 1 1/4” 1” 178 660 320 550 920 760 160
NEINOX 70 77 66.220 91,5 91,3 3 230/50 1 1/4” 1 1/4” 1” 178 660 320 550 1.010 760 200

Boiler Boiler Useful power


code type kW kcal/h
00902091 NEINOX 22 22 18.800
00902101 NEINOX 31 31 26.600
00902111 NEINOX 40 40 34.400
00902121 NEINOX 50 50 43.000
00902131 NEINOX 70 70 60.200

11
High-efficiency steel boilers

•MINIA R - MINIA CI
– High-efficiency steel boilers for hot sanitary water heating (mod. R) and
instantaneous supply, ideal for domestic heating.
- Ultra thick steel boiler shell.
- Instantaneous exchanger for hot sanitary water (mod. CI).
- Burner fitted with external air intake.
- Expansion tank 101.
- Heating circuit circulator.
- Hydraulic 3-way valve (mod. CI).
- Stainless steel turbolators.
- IPX4D protection degree.

• Pre-assembled and pre-calibrated burner


– Two-valve gas burner, stabilizer, filter, gas and air pressure switch for
minimum pressure.
- High-performance cone-shaped light oil burner, complete with nozzle
pre-heater.

• Electronic control panel featuring the following


functions:
– Heating and sanitary temperature regulation.
- Defect display.
- Anti-freeze function.
- Post-circulation function.

• Installation and Maintenance


– Maintenance is made simple thanks to easy accessibility to internal
components.
- Installation is enabled by the burner pre-assembly.

• Optional accessories
– For optional accessories intended for MINIA R – MINIA CI boilers see
page 85.

• Certification
– MINIA R and MINIA CI boilers are EC type approved.

450 610
a4
a2 a5
a1
850

Ø100
620

a3

Boiler Furnace power Useful efficiency% Maximum Power Hot sanitary Heating Heating Boiler Entrata Uscita Weight
type heating pressure voltage water production delivery return discharge acqua F acqua C
kW kcal/h 100 % 30 % risc. sanit. V/Hz l/h Ø a1 Ø a2 Ø a3 Ø a4 Ø a5 kg
MINIA 31 R 33,9 29.154 90,26 91,02 3 - 230/50 - 60 3/4” 3/4” 1/2” - 72
MINIA 31 CI 33,9 29.154 90,26 91,02 3 6 230/50 14,5 60 3/4” 3/4” 1/2” 1/2” 80

Boiler Useful power


type kW kcal/h
MINIA 31 R 30,5 26.230
MINIA 31 CI 30,5 26.230

12
High-efficiency steel boilers

•MINIA CB
– High-efficiency proof steel boilers for hot sanitary water heating supply,
ideal for domestic heating.
- Ultra thick steel boiler shell.
- 120 Lt. storage boiler in painted steel for big amounts of hot sanitary
water.
- 12 Lt. expansion tank for heating circuit.
- Sanitary and heating circuit circulators.
- Stainless steel turbolators.
- IPX4D protection degree.

• Pre-assembled and pre-calibrated burner fitted with


external air intake
– Two-valve gas burner, stabilizer, filter, gas and air pressure switch for
minimum pressure.
- High-performance cone-shaped light oil burner.

• Electronic control panel featuring the following


functions:
– Heating temperature regulation through display (hot sanitary water/
heating).
- Time and date schedule of daily and weekly operation intervals for
heating and sanitary circuits.
- Multifunction LCD display and relevant digital controls.
- Reckoning of the operation hours.
- CHECK CONTROL function for self-diagnosis.
- Circulator antiscuff (once every 170 hours).
- “Antilegionella” function (once every 168 hours with the boiler
temperature amounting to 60°C).
- Summer/Winter/Manual/Stand-by operational conditions.

• Installation and Maintenance


– Maintenance is made simple thanks to easy accessibility to internal
components.
- Installation is enabled by the burner pre-assembly.

• Optional accessories
– For optional accessories intended for MINIA CB boilers
see page 85.
600 150 600 179
– External probe allowing variable temperature management
within the operation range intended for the boiler. a1
– Room thermostat or “remote” control with/without
a2 1
external probe.
Ø100

– “Multizone” card for managing up to 4 direct zones or up to a2 2 a3 1


2 direct and 1 mixed zone, with/without external probe. a2 3 a3 2
a7 a3 3
• Certification a8
1330

1240

– MINIA CB boilers are EC type approved.


a5
a4 a6

Boiler Furnace Useful Maximum Power Hot sanitary water Heating Heating Air Cold water Hot water Burner Light oil Gas Weight
type power efficiency % heating voltage production ΔT 30°C delivery return change inlet outlet suction unit connection connection
kW kcal/h 100 % 30 % pressure V/Hz l/h Ø a2 Ø a3 Ø a4 Ø a6 Ø a5 Ø a1 Ø a7 Ø a8 kg
MINIA 31 CB 33,9 29.154 90,26 91,02 3 6 230/50 765 3/4” 3/4” 3/4” 3/4” 3/4” 80 3/4” 3/8” 202

Boiler Useful power


type kW kcal/h
MINIA 31 CB 30,5 26.230

13
High-efficiency steel boilers

•“proof” MINIA N CBX


– High-efficiency proof steel boilers for hot sanitary water heating
supply, ideal for domestic heating.
- Ultra thick steel boiler shell.
- Stainless steel high-density 90 Lt. boiler, covered with polystyrene for
big amounts of hot sanitary water.
- Burner fitted with external air inlet.
- 10 Lt. expansion tank for heating circuit.
- 3 Lt. expansion tank for sanitary circuit
- Sanitary and heating circuit circulators.
- Stainless steel turbolators.
- IPX4D protection degree.

• Pre-assembled and pre-calibrated burner fitted with


external air intake
– Two-valve gas burner, stabilizer, filter, gas and air pressure switch for
minimum pressure.
- High-performance cone-shaped light oil burner.

• Electronic control panel featuring the following


functions:
– Heating and sanitary temperature regulation.
- Defect display.
- Anti-freeze function.
- Differentiated disposal after-circulation function.
- “Antilegionella” function (once every 168 hours with the boiler
temperature amounting to 60°C).

• Installation and Maintenance


– Maintenance is made simple thanks to easy accessibility to internal
components.
- Installation is enabled by the burner pre-assembly.

• Certification
– MINIA N CBX boilers are EC type approved.

a6 Ø 100

89
a1
a2
47,5 47,5
1400

a7
1215,5
1125,5

a8 a7
a5
660
635
424,5
474

a3
252

a4
68
79,5

500 750 250


452,5

Boiler Furnace Useful Maximum Power Hot sanitary water Heating Heating Air Cold water Hot water Burner Light oil Gas Weight
type power efficiency % heating voltage production ΔT 30°C delivery return change inlet outlet suction unit connection connection
kW kcal/h 100 % 30 % risc. sanit. V/Hz l/h Ø a1 Ø a2 Ø a3 Ø a4 Ø a5 Ø a6 Ø a7 Ø a8 kg
MINIA N 31 CBX 34,8 29.930 91 91,5 3 6 230/50 800 3/4” 3/4” 3/4” 3/4” 3/4” 80 3/8” 3/4” 150

Boiler Useful power


type kW kcal/h
MINIA N 31 CBX 31,7 27.200

14
High-efficiency steel boilers

¥MEGA PREX BT
Low temperature and low emission
- Pressurized boilers, ideal for medium/big-size buildings heating.
- Low variable temperature for maximum efficiency.
- Steel boiler shell featuring 3 pass exaust way
- Low NOx emissions in the environment.
- Heat resistant protection of the combustion chamber allowing to keep
high flue gas temperature.
- Two ultra thick steel concentric flues enabling even distribution of heat
and avoiding condensation.
- Stainless steel turbolators.
- Hinged opening door.
- Standard special front insulation.
- Heat loss preventing ultra thick insulation.
- Vertically arranged shell and tube structure, placed over the furnace.
- Reduced width (<90 cm).
- External instrument panel for unit control and adjustment.
- Control thermometer pocket.
- Light oil and gas burner operation.
I L
¥ Installation and Maintenance a2 a3 a5 a6 a1

160
- A burner can be fitted onto the boiler plate.

M
- Maintenance is made simple thanks to easy accessibility to internal
components.
a8
¥ Certification
– MEGA PREX BT boilers are EC type approved. a9

H
D
a7
a4

E
B A
C A1

boiler A A1 B C D E H I L M weight
type mm. mm. mm. mm. mm. mm. mm. mm. mm. mm. kg
MEGA PREX BT 100 660 715 1.252 1.655 978 374 1.225 565 740 52 625
MEGA PREX BT 150 660 715 1.252 1.655 978 374 1.225 565 740 52 655
MEGA PREX BT 180 700 755 1.412 1.815 1.082 410 1.345 565 900 52 750
MEGA PREX BT 230 700 755 1.412 1.815 1.082 410 1.345 565 900 52 790
MEGA PREX BT 290 745 800 1.462 1.865 1.210 460 1.500 615 900 57 900
MEGA PREX BT 350 820 875 1.744 2.147 1.340 495 1.630 665 1.075 53 1.100
MEGA PREX BT 400 820 875 1.744 2.147 1.340 495 1.630 665 1.075 53 1.160
MEGA PREX BT 460 890 945 1.744 2.147 1.422 520 1.750 665 1.075 50 1.380
MEGA PREX BT 580 890 945 1.744 2.147 1.422 520 1.750 665 1.075 50 1.450

boiler boiler useful power


code type kW kcal/h
00902001 M. PREX BT 100 105 90.300
00902011 M. PREX BT 150 151 129.860
00902021 M. PREX BT 180 186 160.000
00902031 M. PREX BT 230 233 200.380
00902041 M. PREX BT 290 291 250.260
00902051 M. PREX BT 350 349 300.140
00902061 M. PREX BT 400 407 350.000
00902071 M. PREX BT 460 465 399.900
00902081 M. PREX BT 580 581 499.660

15
High-efficiency steel boilers

¥MEGA PREX 90÷1150


- Pressurized boilers, ideal for medium/big-size buildings heating.
- Flame injection furnace steel boiler shell.
- Light oil and gas burner operation.
- External instrument panel for unit control and adjustment.
- Heat loss preventing ultra thick insulation.
- Standard special front insulation in models 90 ÷ 1150.
- Hinged opening door.
- Stainless steel turbolators.
- Ultra thick steel flues.
- Control thermometer pocket.

• Installation and Maintenance


- A burner can be fitted onto the boiler plate.
- Maintenance is made simple thanks to easy accessibility to internal
components.

• Certification
- MEGA PREX boilers are EC type approved.

- See sizes on page 18.

Flame injection operation

boiler boiler useful power


code type kW kcal/h
00902151 M. PREX 90 93 80.000
00902161 M. PREX 100 105 90.000
00902171 M. PREX 115 116 100.000
00902181 M. PREX 150 151 130.000
00902191 M. PREX 180 186 160.000
00902201 M. PREX 230 232 200.000
00902211 M. PREX 290 290 250.000
00902221 M. PREX 340 349 300.000
00902231 M. PREX 400 407 350.000
00902241 M. PREX 460 465 400.000
00902251 M. PREX 580 581 500.000
00902261 M. PREX 700 698 600.000
00902271 M. PREX 800 814 700.000
00902281 M. PREX 930 930 800.000
00902291 M. PREX 1050 1.046 900.000
00902301 M. PREX 1150 1.163 1.000.000

16
High-efficiency steel boilers

¥MEGA PREX 1400÷2900


- Pressurized boilers, ideal for big buildings heating.
- Flame injection furnace steel boiler shell.
- Light and oil burner operation.
- External instrument panel for unit control and adjustment.
- Heat loss preventing ultra thick insulation.
- Hinged opening door.
- Stainless steel turbolators.
- Control thermometer pocket.

¥ Installation and Maintenance


- A burner can be fitted onto the boiler plate.
- Maintenance is made simple thanks to easy accessibility to internal
components.

¥ Certification
- MEGA PREX boilers are EC type approved.

- See sizes on page 18.

Flame injection operation

boiler boiler useful power


code type kW kcal/h
00908440 M. PREX 1400 1.395 1.200.000
00908450 M. PREX 1550 1.569 1.350.000
00908460 M. PREX 1750 1.744 1.500.000
00908470 M. PREX 2000 1.976 1.700.000
00908480 M. PREX 2300 2.325 2.000.000
00908490 M. PREX 2900 2.907 2.500.000

17
High-efficiency steel boilers

¥ Technical data and sizes of MEGA PREX

boiler furnace power useful efficiency maximum power heating heating Instrument Boiler expansion flue burner thermostat
type % heating pressure voltage delivery return connection discharge tank connection connection socket
kW kcal/h 100 % 30 % bar V/Hz DN a1 DN a2 Ø a3 Ø a4 Ø a5 Ø a6 Ø a7 Ø a8
MEGA PREX 90 102 87.740 91,18 89,7 5 230/50 50 50 1” 1” - 200 130 1/2”
MEGA PREX 100 115 98.570 91,3 90,11 5 230/50 50 50 1” 1” - 200 130 1/2”
MEGA PREX 115 127 109.480 90,63 90,05 5 230/50 50 50 1” 1” - 200 130 1/2”
MEGA PREX 150 165 142.050 90,42 91,15 5 230/50 50 50 1” 1” - 250 160 1/2”
MEGA PREX 180 203 174.620 90,73 90,36 5 230/50 50 50 1” 1” - 250 160 1/2”
MEGA PREX 230 252 217.240 90,63 90,23 5 230/50 65 65 1” 1” - 250 180 1/2”
MEGA PREX 290 314 270.690 90,91 89,74 5 230/50 65 65 1” 1” - 250 180 1/2”
MEGA PREX 340 378 324.930 90,18 89,91 5 230/50 80 80 1” 1” 1 1/4”** 250 225 1/2”
MEGA PREX 400 442 380.100 90,04 89,82 5 230/50 80 80 1” 1” 1 1/4”** 250 225 1/2”
MEGA PREX 460 504 443.550 90,29 90,07 5 230/50 80 80 1” 1 1/4” 1 1/4” 300 225 1/2”
MEGA PREX 580 633 544.750 90,22 89,94 5 230/50 80 80 1” 1 1/4” 1 1/4” 300 225 1/2”
MEGA PREX 700 760 653.300 90,05 89,76 5 230/50 100 100 1” 1 1/4” 1 1/2” 350 280 1/2”
MEGA PREX 800 889 764.500 90,14 89,89 5 230/50 100 100 1” 1 1/4” 1 1/2” 350 280 1/2”
MEGA PREX 930 1.018 875.700 90,20 89,94 5 230/50 100 100 1” 1 1/4” 1 1/2” 350 280 1/2”
MEGA PREX 1050 1.139 980.020 90,17 89,86 5 230/50 125 125 1” 1 1/4” 1 1/2” 400 280 1/2”
MEGA PREX 1150 1.265 1.088.640 90,78 90,13 5 230/50 125 125 1” 1 1/4” 1 1/2” 400 280 1/2”
MEGA PREX 1400 1.528 1.314.410 90,23 90,02 5 230/50 150 150 1” 1 1/4” 1 1/2” 400 320 -
MEGA PREX 1550 1.719 1.479.060 90,22 90,09 5 230/50 150 150 1” 1 1/4” 1 1/2” 400 320 -
MEGA PREX 1750 1.907 1.640.190 90,36 90,09 5 230/50 150 150 1” 1 1/4” 1 1/2” 400 320 -
MEGA PREX 2000 2.170 1.866.900 90,39 90,23 5 230/50 200 200 1 1/2” 1 1/4” 2” 500 360 -
MEGA PREX 2300 2.554 2.196.990 90,08 89,81 5 230/50 200 200 1 1/2” 1 1/4” 2” 500 360 -
MEGA PREX 2900 3.197 2.749.400 90,25 89,94 5 230/50 200 200 1 1/2” 1 1/4” 2” 550 400 -
* Only one connection

C
M L

116
C a2 a3 a5 a1
M L
a2 a3 a5 a1
160
E

a7
a8
a7
H

a6
H

D
a6
D

a4 a4

A A
B A1 B A1

MEGA PREX 90÷ 1.150 MEGA PREX 1.400÷ 2.900

boiler A A1 B C D E H L M weight
type mm. mm. mm. mm. mm. mm. mm. mm. mm. kg
MEGA PREX 90 700 750 755 1.195 415 56 855 265 484 240
MEGA PREX 100 700 750 755 1.195 415 56 855 265 484 240
MEGA PREX 115 700 750 755 1.195 415 56 855 265 484 240
MEGA PREX 150 750 800 1.000 1.440 440 56 905 475 484 320
MEGA PREX 180 750 800 1.000 1.440 440 56 905 475 484 320
MEGA PREX 230 850 900 1.250 1.690 490 56 1.005 700 484 440
MEGA PREX 290 850 900 1.500 1.940 490 56 1.005 980 484 500
MEGA PREX 340 890 940 1.502 1.900 500 80 1.015 850 600 540
MEGA PREX 400 890 940 1.502 1.900 500 80 1.015 850 600 540
MEGA PREX 460 1.110 1.160 1.502 1.950 610 80 1.205 850 660 800
MEGA PREX 580 1.110 1.160 1.792 2.240 610 80 1.205 1.150 660 900
MEGA PREX 700 1.240 1.290 1.753 2.255 675 82 1.335 1.100 710 1.140
MEGA PREX 800 1.240 1.290 2.003 2.500 675 82 1.335 1.200 710 1.340
MEGA PREX 930 1.240 1.290 2.003 2.500 675 82 1.335 1.200 710 1.340
MEGA PREX 1050 1.390 1.440 2.003 2.500 750 83 1.485 1.200 710 1.760
MEGA PREX 1150 1.390 1.440 2.003 2.500 750 83 1.485 1.200 710 1.760
MEGA PREX 1400 1.270 1.470 2.300 2.850 880 - 1.630 1.300 795 2.600
MEGA PREX 1550 1.270 1.470 2.300 2.850 880 - 1.630 1.300 795 2.600
MEGA PREX 1750 1.270 1.470 2.510 3.060 880 - 1.630 1.850 735 2.750
MEGA PREX 2000 1.400 1.600 2.510 3.190 945 - 1.760 1.550 870 3.650
MEGA PREX 2300 1.400 1.600 2.770 3.450 945 - 1.760 1.950 870 3.900
MEGA PREX 2900 1.670 1.870 2.770 3.450 1.080 - 2.030 2.050 870 5.200

18
High-efficiency steel boilers

¥MEGA PREX SL
- Pressurized boilers, ideal for medium/big-size buildings heating.
- Ultra reduced width (<80 cm), for easy replacement in existing heating
plants.
- Flame injection furnace steel boiler.
- Vertically arranged shell and tube structure, placed over the furnace.
- Light oil and gas burner operation.
- External instrument panel for unit control and adjustment.
- Heat loss preventing ultra thick insulation.
- Standard special front insulation.
- Hinged opening door.
- Stainless steel turbolators.
- Ultra thick steel flues.
- Control thermometer pocket.

¥ Installation and Maintenance


- A burner can be fitted onto the boiler plate.
- Maintenance is made simple thanks to easy accessibility to internal
components.

¥ Certification
- MEGA PREX SL boilers are EC type approved.

685 800 685 850


a2 a3 a5 a1 a2 a3 a5 a1
80

80
160

160
Ø 250

Ø 250
1200

1290

a6 a6
900

950

a4 a4
440

460

1410 700 1460 750


1900 750 1950 800

MEGA PREX SL 230 - MEGA PREX SL 290 MEGA PREX SL 340 - MEGA PREX SL 400

boiler furnace power useful efficiency maximum power heating heating Instrument Boiler Safety burner weight
type % heating pressure voltage delivery return connection discharge valve connection
kW kcal/h 100 % 30 % bar V/Hz DN a1 DN a2 Ø a3 Ø a4 Ø a5 Ø a6 kg
MEGA PREX SL 230 255 219.300 91,7 90,85 5 230/50 65 65 1” 1” 1” 155 720
MEGA PREX SL 290 319 274.340 90,86 90,56 5 230/50 65 65 1” 1” 1” 155 780
MEGA PREX SL 340 384 330.240 90,98 90,71 5 230/50 80 80 1 1/4” 1 1/4” 1” 180 900
MEGA PREX SL 400 448 385.280 90,84 90,62 5 230/50 80 80 1 1/4” 1 1/4” 1” 180 980

boiler boiler useful power


code type kW kcal/h
00902451 M. PREX SL 230 232 200.000
00902461 M. PREX SL 290 290 250.000
00902471 M. PREX SL 340 349 300.000
00902481 M. PREX SL 400 407 350.000

19
High-efficiency steel boilers

¥DUO PREX
- Pressurized boilers ideal for medium/big-size buildings heating.
- 2 superposed steel boiler shells with flame injection.
- High heating power with reduced overall dimensions.
- Operation through gas blown burners.
- External instrument panel for unit control and adjustment.
- Heat loss preventing ultra thick insulation.
- Standard special front insulation.
- Hinged opening door.
- Stainless steel turbolators.
- Ultra thick steel flues.
- Control thermometer pocket.

¥ Installation and Maintenance


- A burner can be fitted onto the boiler plate.
- Maintenance is made simple thanks to easy accessibility to internal
components.

¥ Certification
- DUO PREX boilers are EC type approved.
C E E
a3 a1

a6 a5

a4 a2
H

G
a6 a5

D1
D1

F
a4
D
D

A
A1 185

boiler A A1 B C D D1 E F G H weight
type mm. mm. mm. mm. mm. mm. mm. mm. mm. mm. kg
DUO PREX 180 700 750 755 1470 415 1245 270 780 1610 1693 454
DUO PREX 200 700 750 755 1470 415 1245 270 780 1610 1693 476
DUO PREX 230 700 750 755 1470 415 1245 270 780 1610 1693 500
DUO PREX 300 750 800 1000 1745 440 1320 295 830 1710 1793 695
DUO PREX 360 750 800 1000 1745 440 1320 295 830 1710 1793 725
DUO PREX 460 850 900 1250 2000 490 1470 345 930 1910 1993 870
DUO PREX 580 850 900 1250 2000 490 1470 345 930 1910 1993 1116
boiler furnace power useful efficiency maximum power voltage heating heating Instrument Boiler flue burner
type % heating pressure delivery return connection discharge connection connection
kW kcal/h 100 % 30 % bar V/Hz DN a1 DN a2 Ø a3 Ø a4 Ø a5 Ø a6
DUO PREX 180 204 175.800 91,18 90,3 5 230/50 65 65 1” 1” 200 120
DUO PREX 200 230 198.000 90,87 90,3 5 230/50 65 65 1” 1” 200 120
DUO PREX 230 257 220.800 90,66 90,15 5 230/50 65 65 1” 1” 200 120
DUO PREX 300 333 286.400 90,69 90,25 5 230/50 80 80 1” 1” 250 155
DUO PREX 360 411 353.200 90,51 90,3 5 230/50 80 80 1” 1” 250 155
DUO PREX 460 512 440.000 90,82 90 5 230/50 80 80 1” 1” 250 155
DUO PREX 580 639 549.400 90,92 90,2 5 230/50 80 80 1” 1” 250 155

boiler boiler useful power


code type kW kcal/h
00902381 DUO PREX 180 186 160.000
00902391 DUO PREX 200 209 180.000
00902401 DUO PREX 230 233 200.000
00902411 DUO PREX 300 302 260.000
00902421 DUO PREX 360 372 320.000
00902431 DUO PREX 460 465 400.000
00902441 DUO PREX 580 581 500.000

20
High efficiency cast iron boilers

SEC B
EXA
VIT
BIA F
BIG F
BIG FK
In compliance with:
DIRECTIVE 90/396/EEC ON GAS APPLIANCES
DIRECTIVE L.V. 72/23/EEC (Act No. 791 of 18/10/77)
EFFICIENCY DIRECTIVE 92/42/EEC

SEC B
EXA
VIT
BIAF
BIGF
BIGFK
20,9 30,6 32,55 46,5 93,3 107 200 252 650
kW
21
High efficiency cast iron boilers

•SEC B
- Basement boiler suitable for hot sanitary water heating and supply.
- Cast iron boiler shell.
- Stainless steel 90 Lt. boiler.
- Sanitary circuit circulator.
- Combustion chamber and exchanger being designed for over 90%
guaranteed efficiency.
- Operation through gas blown burners.
- Instrument panel for proper operation control.
- Heat loss preventing ultra thick insulation.
- Suitable for clock controller fitting.

• Installation and Maintenance


- A burner can be fitted onto the boiler plate.
- Maintenance is made simple thanks to easy accessibility to internal
components.

• Certificazione
- SEC B boilers are EC type approved.

500 600

a4
a6
a5
1500

a1
1248

• Clock controller kit


1098
948

Ø105
Ø130

711

a2 a3
542

Code Description
274

08506540 Clock controller kit


64
80

85

boiler furnace power useful efficiency max. pressure power hot sanitary water heating heating Boiler Boiler Boiler Ricircolo weight
type % bar voltage supply ΔT 30°C delivery return discharge delivery return
kW kcal/h 100 % 30 % heating sanitary V/Hz l/h Ø a1 Ø a2 Ø a3 Ø a4 Ø a5 Ø a6 kg
SEC 30 B 34 29.240 90 92 4 6 230/50 900 1 ˚” 1 ˚” 1/2” 3/4” 3/4” 3/4” 135

boiler boiler useful power


code type kW kcal/h
00905430 SEC 30 B 30,6 26.316

22
High efficiency cast iron boiler

•EXA
- Basement boiler suitable for hot sanitary water heating and supply.
- Cast iron boiler shell.
- Combustion chamber and exchanger being designed for over 90%
guaranteed efficiency.
- Operation through gas blown burners.
- Heat loss preventing ultra thick insulation.
- Instrument panel for proper operation control.
- EXA boilers can be combined with PAC S and BITHERM boilers.

• Installation and Maintenance


- A burner can be fitted onto the boiler plate.
- Maintenance is made simple thanks to easy accessibility to internal
components.

• Certification
- EXA boilers are EC type approved.

450 A a1
C
850

• EXA-PAC S electrical connection kit.


711 a2 a3
542
274

Code Description B
08515320 EXA-PAC S electrical connection kit.

64
80
85

boiler furnace power useful efficiency maximum sanitary power voltage heating heating Boiler A B C weight
type % heating pressure delivery return discharge
kW kcal/h 100% 30% bar V/Hz DN a1 DN a2 Ø a3 mm. Ø mm. Ø mm. Kg
EXA 20 23,25 19.995 90 92 4 230/50 1 ˚” 1 ˚” 1/2” 420 105 130 80
EXA 27 34 29.240 90 92 4 230/50 1 ˚” 1 ˚” 1/2” 420 105 130 105
EXA 32 38,6 33.196 90,4 92,08 4 230/50 1 ˚” 1 ˚” 1/2” 420 105 130 105
EXA 40 51,4 44.204 90,4 92,14 4 230/50 1 ˚” 1 ˚” 1/2” 620 105 130 130
EXA 50 64,1 55.126 90,6 92,23 4 230/50 1 ˚” 1 ˚” 1/2” 620 105 180 155
EXA 60 77,2 66.392 90,4 92,17 4 230/50 1 ˚” 1 ˚” 1/2” 820 125 180 180
EXA 70 89,7 77.142 90,7 92,25 4 230/50 1 ˚” 1 ˚” 1/2” 820 125 180 205
EXA 80 103,2 88.752 90,4 92,2 4 230/50 1 ˚” 1 ˚” 1/2” 920 125 180 230

boiler boiler useful power


code type kW kcal/h
00905100 EXA 20 20,9 17.974
00905110 EXA 27 30,6 26.316
00905120 EXA 32 34,9 30.014
00905130 EXA 40 46,5 39.990
00905140 EXA 50 58,1 49.996
00905150 EXA 60 69,8 60.028
00905160 EXA 70 81,4 70.004
00905170 EXA 80 93,3 80.238

23
High efficiency cast iron boiler

•VIT
- Basement boiler suitable for hot sanitary water heating and supply.
- Cast iron boiler shell.
- Instantaneous exchanger for hot sanitary water (models VIT CI).
- Pre-assembled and pre-calibrated light gas burner, complete with
nozzle pre-heater.
- Burner fitted with external air inlet.
- Heating circuit 10 Lt. expansion tank.

G
- Heating circuit circulator.
- 3-way electrical valve.
- Combustion chamber and exchanger being designed for over 90%
guaranteed efficiency.
- Heat loss preventing ultra thick insulation.
- Instrument panel for proper operation control.
- IP X4D protection degree.

• Electronic control panel featuring the following


functions:
- Heating temperature regulation.
- Defect display.
- Anti-freeze function.
- Post-circulation function.

• Installation and Maintenance


- Maintenance is made simple thanks to easy accessibility to internal
components.
- A burner can be fitted onto the boiler plate.

• Certification
- VIT boilers are EC type approved (only for light gas operation).

• Range of product
- VIT R boiler: only for heating.
- VIT CI: for hot sanitary water heating and supply.

boiler furnace power useful efficiency maximum pressure power hot sanitary water heating heating Cold waterHot water weight
type % bar voltage supply ΔT 30°C delivery return inlet outlet
kW kcal/h 100 % 30 % risc. sanit. V/Hz l/min. Ø a1 Ø a2 Ø a3 Ø a4 kg
VIT 30 R 34,76 29.900 91,5 92,2 3 - 230/50 - 3/4” 3/4” 1/2” - 160
VIT 30 CI 34,76 29.900 91,5 92,2 3 6 230/50 2,5÷ 15,5 3/4” 3/4” 1/2” 1/2” 160

boiler burner boiler useful power


code type type kW kcal/h
00704881 ECO 3 R VIT 30 R 32,55 28.000
00704891 ECO 3 R VIT 30 CI 32,55 28.000

24
High efficiency cast iron boiler

•“proof” BIA F
- Proof basement boilers suitable for hot sanitary water heating and supply.
- Cast iron boiler shell.
- Combustion chamber and exchanger being designed for over 90%
guaranteed efficiency.
- Stainless steel boiler, covered with high-density polystyrene: 90 Lt. for
model BIA 30-90 and 120 Lt. for model BIA 40-120.
- Burner fitted with external air inlet.
- Heating circuit 10 Lt. expansion tank.
- Sanitary circuit 4 Lt. expansion tank.
- Heating and sanitary circuit circulators.
- IP X4D protection degree.

• Pre-assembled and pre-calibrated air inlet burner


- Two-valve gas burner, stabilizer, filter, gas and air pressure switch for
minimum pressure.
- High-performance cone-shaped light oil burner, complete with nozzle
pre-heater.

• Electronic control panel featuring the following


functions:
- Heating and sanitary temperature regulation.
- Defect display.
- Anti-freeze function.
- Post-circulation function.
- “antilegionella” function.

• Installation and Maintenance


- A burner can be fitted onto the boiler plate.
- Maintenance is made simple thanks to easy accessibility to internal
components.

• Certification
- BIA F boilers are EC type approved.
 Gas thermal couplings are supplied on demand. Please contact
our Sales Department to be informed on the delivery time.

Ø 130 Ø 130
a1 a1
a6 a6
1400

1400

a2 a2
1037

1037

a3 a3
a5 a5
a4 a4

500 706 500 906

BIA F 30-90 BIA F 40-120

boiler furnace useful maximum power hot sanitary water heating heating boiler boiler hot water tank burner weight
type power efficiency % pressure bar voltage supply ΔT 30°C delivery return delivery return ricirculation suction unit
kW kcal/h 100 % 30 % risc. sanit. V/Hz l/h Ø a1 Ø a2 Ø a3 Ø a4 Ø a5 Ø a6 kg
BIA F 30-90 34 29.240 90 92 3 7 230/50 800 1” 1” 3/4” 3/4” 3/4” 80 180
BIA F 40-120 51,4 44.204 90,4 92,14 3 7 230/50 900 1” 1” 3/4” 3/4” 3/4” 80 240

boiler useful power


type kW kcal/h
BIA F 30-90 30,6 26.316
BIA F 40-120 46,5 39.990

25
High efficiency cast iron boiler

¥BIG F
- Proof basement boilers suitable for medium-sized systems.
- Pre-assembled high-quality cast iron boiler shell.
- Combustion chamber and exchanger being designed for over 90%
guaranteed efficiency.
- Light gas and gas burner operation.
- Heat loss preventing ultra thick insulation.
- Instrument panel for proper operation control.
- IP X4D protection degree.

• Installation and Maintenance


- A burner can be fitted onto the boiler plate.
- Maintenance is made simple thanks to easy accessibility to internal
components.

¥ Certification
- BIG F boilers are EC type approved.
- Available in FK version “to be assembled”
160

CALORECLIMA

a1

C
1196

867
B

726
375

84

600 A a2 a3

boiler furnace power useful efficiency maximum power heating heating Burner A B C weight
type Light oil Gas pressure voltage delivery return discharge
kW kcal/h 100% 100% 30% bar V/Hz DN a1 DN a2 Ø a3 mm. Ø mm. Ø mm. Kg
BIG F 107 116 99.760 91,8 91,3 92,2 6 230/50 80 - 3” 80 - 3” 3/4” 757 180 120 411
BIG F 126 136,9 117.734 91,9 91,2 92,4 6 230/50 80 - 3” 80 - 3” 3/4” 867 180 120 462
BIG F 144 156,5 134.590 92,2 91,5 92,3 6 230/50 80 - 3” 80 - 3” 3/4” 977 200 120 513
BIG F 162 176 151.360 92,3 91,7 92,4 6 230/50 80 - 3” 80 - 3” 3/4” 1.087 200 150 564
BIG F 180 195,6 168.216 92,3 91,8 92,4 6 230/50 80 - 3” 80 - 3” 3/4” 1.197 200 150 615
BIG F 198 215,2 185.072 92,2 91,8 92,4 6 230/50 80 - 3” 80 - 3” 3/4” 1.307 200 150 666
BIG F 216 234,7 201.842 92,4 91,9 92,5 6 230/50 80 - 3” 80 - 3” 3/4” 1.417 200 150 720
BIG F 234 254,3 218.698 92,4 91,9 92,6 6 230/50 80 - 3” 80 - 3” 3/4” 1.527 200 150 775
BIG F 252 273,9 235.554 92 92 92,6 6 230/50 80 - 3” 80 - 3” 3/4” 1.637 200 150 830

boiler boiler useful power


code type kW kcal/h
00906040 BIG F 107 107 92.020
00906050 BIG F 126 126 108.360
00906060 BIG F 144 144 123.840
00906070 BIG F 162 162 139.320
00906080 BIG F 180 180 154.800
00906090 BIG F 198 198 170.280
00906100 BIG F 216 216 185.760
00906110 BIG F 234 234 201.240
00906120 BIG F 252 252 216.720

26
High efficiency cast iron boiler

¥BIG FK to be assembled
- Proof basement boilers suitable for medium- and big-sized systems.
- High-quality cast iron boiler shell, with components to be assembled
during the installation of the boiler at the heating plant; three pass
exaust way.
- Combustion chamber and exchanger being designed for over 90%
guaranteed efficiency.
- Light gas and gas burner operation.
- Ideal for low temperature (35°C) system operation.
- Heat loss preventing ultra thick insulation.
- Instrument panel for proper operation control.
- IP X4D protection degree.

• Installation and Maintenance


- A burner can be fitted onto the boiler plate.

¥ Certificazione
- BIG FK boilers are EC type approved.
160

CALORECLIMA

a3 281,5 a1
10 a4
1180

898

B
463

463
83

850 A a2

boiler furnace power useful efficiency maximum power voltage heating heating heating heating A B C weight
type % pressure delivery return delivery BTreturn BT
kW kcal/h 100% 30% bar V/Hz DN a1 DN a2 DN a3 DN a4 mm. Ø mm. Ø mm. Kg
BIG FK 200 217 186.620 92,2 95,4 6 230/50 80 - 3” 80 - 3” 80 - 3” 80 - 3” 1.040 180 145 890
BIG FK 250 270 232.200 92,6 96 6 230/50 80 - 3” 80 - 3” 80 - 3” 80 - 3” 1.170 180 150 1.000
BIG FK 300 324 278.640 92,6 96,5 6 230/50 80 - 3” 80 - 3” 80 - 3” 80 - 3” 1.300 250 150 1.110
BIG FK 360 388 333.680 92,8 97,1 6 230/50 80 - 3” 80 - 3” 80 - 3” 80 - 3” 1.430 250 180 1.220
BIG FK 420 452 388.720 92,9 97,1 6 230/50 80 - 3” 80 - 3” 80 - 3” 80 - 3” 1.560 250 180 1.330
BIG FK 480 516 443.760 93 97,2 6 230/50 80 - 3” 80 - 3” 80 - 3” 80 - 3” 1.690 250 180 1.440
BIG FK 560 600 516.000 93,3 97,3 6 230/50 80 - 3” 80 - 3” 80 - 3” 80 - 3” 1.820 250 205 1.550
BIG FK 650 695 597.700 93,5 97,3 6 230/50 80 - 3” 80 - 3” 80 - 3” 80 - 3” 1.950 250 205 1.660

boiler boiler useful power


code type kW kcal/h
00906130 BIG FK 200 200 172.000
00906140 BIG FK 250 250 215.000
00906150 BIG FK 300 300 258.000
00906160 BIG FK 360 360 309.600
00906170 BIG FK 420 420 361.200
00906180 BIG FK 480 480 412.800
00906190 BIG FK 560 560 481.600
00906200 BIG FK 650 650 559.000

27
28
Air heaters

“Wall-hung” air heaters


AIR-A
AIR-AC
AIR-ACE

“Industrial” air heaters


LGE
LGE OUT

Zone management equipment


BOX ZONE

DIRECTIVE 90/396/EEC (BOX ZONE not included)


DIRECTIVE E.M.C. 89/336/EEC (Act No. D.L. 476 of 4/12/92) (LGE – LGE OUT and BOX ZONE not included)
DIRECTIVE L.V. 72/23/EEC (Act No. 791 of 18/10/77) (BOX ZONE not included)

AIR-A
AIR-AC
AIR ACE
LGE
LGE OUT
3,35 4,91 22,9 28 29,7 31,9 75,6 1047
kW
29
“Wall-hung” air heaters

•AIR-ACE
- Outdoor wall-hung proof and ducted gas air heaters.
- Zone heating allowed.
- Stainless steel exchanger, combustion chamber and enbloc flue header.
- Stainless steel atmospheric burner suitable for all kinds of gas.
- Panels treated for external use.
- Flue discharge electrical fan.
- Electronic ignition.
- Ionization flame control.
- Centrifugal fan unit.
- IP X4D protection degree.

• Maintenance
- Maintenance is made simple thanks to easy accessibility to internal
components.

• Standard accessories
- GPL nozzles.
- Delivery duct union.
- Air inlet duct horizontal union.
- Air duct sloped union complete with grid.
- Flue discharge kit.
- Combustion air suction kit.
- Remote control panel equipped with electrical cable and 10 Mt. sheath.

• Optional accessories
- For the accessories relating to heaters AIR-ACE, please see on page 85.

• Certification
- AIR-ACE air heaters are
EC type approved.

- On demand: Please contact our


Sales Department to be informed on
the delivery time.

heater furnace power useful 20°C air power voltage Noise Prevalence A B weight
type efficiency capacity level a 5 m.
kW kcal/h % m3/h V/Hz dB PA mm. mm. kg
AIR 30 ACE 34,8 29.900 91,7 2.500 230/50 mon. 48,5 80 1.385 167 73
AIR 49 ACE 57 49.000 90,5 5.000 230/50 mon. 51,5 80 1.385 167 125
AIR 73 ACE 85 73.100 89 7.300 230/50 mon. 53 80 1.464 102 207

heater heater useful power


code type kW kcal/h
00064030 AIR 30 ACE 31,9 27.400
00064040 AIR 49 ACE 51,6 44.380
00064050 AIR 73 ACE 75,6 65.050

31
“Industrial” air heaters

•LGE
- High-efficiency basement industrial air heaters.
- Light oil and gas burner operation.
- Stainless steel combustion chamber.
- Low-revolution ventilation unit, consisting of double suction centrifugal
fans.
- Instruments for unit control and adjustment, complete with triple
thermostat and electrical panel.
- Pre-painted sheet panels covered with soundproofing and lagging
coating.
- Side closing panel.
- For models LGE 25 ÷ LGE 65, fan units with 230V/50Hz single-phase
motor are fitted. For remaining models, fan units with 400V/50Hz
three-phase motors are provided.
- Summer ventilation.
- LGE 500 ÷ LGE 900 models are supplied on demand. Please
contact our Sales Department to be informed on the delivery
time.

• Installation and Maintenance


- Installation may be performed in the room through direct supply or be
connected to distribution channels.
- Maintenance is made simple thanks to easy accessibility to internal
components.

• Certification
- LGE air heaters are EC type approved.

- Prices and technical data are shown on page?

G F

C
E

Combustion air and flue discharge way I B


A

heater A B C D E F G H I Ø weight
type mm. mm. mm. mm. mm. mm. mm. mm. mm. mm. kg
LGE 25 - LGE 35 660 530 1.430 305 1.215 490 620 480 620 150 147-155
LGE 51 - LGE 65 870 636 1.750 305 1.500 596 830 630 830 180 220-230
LGE 80 - LGE 100 1.000 750 1.900 405 1.675 670 920 770 920 200 325-335
LGE 125 - LGE 150 1.260 900 2.060 405 1.750 820 1.180 760 1.180 250 493-503
LGE 175 - LGE 200 1.440 1.020 2.340 405 1.975 940 1.360 760 1.360 250 570-595
LGE 250 - LGE 300 1.790 1.020 2.340 405 1.975 940 1.710 760 1.710 300 840-870
LGE 375 1.960 1.280 2.660 405 2.280 1.200 1.880 930 1.880 300 1.230
LGE 425 - LGE 500 2.300 1.340 2.660 405 2.280 1.260 2.220 930 2.220 300 1.515-1.585
LGE 600 2.820 1.550 2.960 445 2.572 1.470 2.740 970 2.740 350 1.935
LGE 750 2.820 1.620 3.100 445 2.672 1.540 2.740 970 2.740 400 2.395
LGE 900 3.720 1.620 3.100 445 2.672 1.540 3.640 970 3.640 400 2.920

32
33
34
35
Zone management devices

•BOX ZONE
- Zone managament devices for systems up to 35 kW.
- Ideal for embedded-type assembly; wall-hung installation is also possible.
- Zone delivery circulators.
- Operation management electronic card.
- Safety thermostat in low temperature zone (Box Mix Zone).
- Circulator anti-blocking function.
- Post-circulation (10 seconds).
- Temperature regulation for precedence probe (25÷ 45°C).
- Anti-freeze device (5÷ 7°C).
- Possible connection of an external probe to the Box Mix Zone (on
demand).
- Electromechanical mixing valve (Box Mix Zone).
- Delivery temperature regulation of low temperature zone (Box Mix Zone).
- Water circuit breaker.
- Led Check Control for defect detection.

• Maintenance
- Maintenance is made simple thanks to easy accessibility to internal
components

• Optional accessories
- To see the accessories suitable for BOX ZONE, see page 85.

• Range of accessories
- Box Mix Zone: for managing 1 high temperature zone and 1 low
temperature zone.
- Box Zone A2: for managing 2 high temperature or low temperature
zones (only for suitable boilers).
- Box Zone A3: for managing 3 high temperature or low temperature
zones (only for suitable boilers).

200 120 200 120 200 120

RC MC RC MC RC MC

RA3 MA 3
RB MB RA2 MA 2 RA2 MA 2
RA MA RA1 MA 1 RA1 MA 1

58 222 76 48 58 146 152 48 58 58 88 76 76 48 60

Box Zona Mix Box Zona A2 Box Zona A3 Vista laterale

MC = Boiler delivery RB = Low temperature heating return


RC = Boiler return MA1 - MA2 - MA3 = Temperature heating delivery systems
MB = Low temperature heating delivery RA1 - RA2 - RA3 = Temperature heating return systems

Box zone Water Maximum Maximum operating Post power Transformer Transformer Width Height Depth Weight
type content operating pressure pressure circulation voltage protection fuse protection fuse
l bar °C sec. V/Hz W A kg
BOX ZONE MIX 5 3 90 10 230/50 260 3,15 440 550 175 17
BOX ZONE A2 5 3 90 10 230/50 230 3,15 440 550 175 18,5
BOX ZONE A3 5 3 90 10 230/50 340 3,15 440 550 175 20,5

Box Zone Box Zone


code type
08516500 BOX ZONE MIX
08516510 BOX ZONE A2
08516520 BOX ZONE A3

36
Wall-hung gas boilers and heating modules

Wall-hung pre-mixed condensation gas boilers


FUTURIA L “MT” - FUTURIA L “MC” - FUTURIA L “MB”
FUTURIA PLUS - FUTURIA N “MT” - FUTURIA N “MC”
Pre-mixed condensation gas heating modules
REPLY
REPLY N

Caldaie murali a gas per interno


XILO LN - XILO T - XILO - XILO D
VELA XN - ALMA

In compliance with:
DIRECTIVE 90/396/EEC
DIRECTIVE E.M.C. 89/336/EEC (Act No. 476 of the 04/12/92)
DIRECTIVE L.V. 72/23/EEC (Act No. 791 of 18/10/77)
EFFICIENCY DIRECTIVE 92/42/EEC

FUTURIA L
FUTURIA N
FUTURIA PLUS
REPLY
REPLY N
XILO LN
XILO
XILO T - XILO D
VELA XN
ALMA
15 22,5 22,75 23,24 23,4 23,66 23,92 24,5 27,48 27,7 27,8 28 28,36 28,5 31,74 31,9 45,2 49 90,4
kW

37
Wall-hung pre-mixed condensation gas boilers

•FUTURIA L “thermal”
- Ultra-high efficiency proof condensation boilers, suitable for heating.
- Ideal for low temperature system operation.
- Special casting aluminium corrosion proofing enbloc exchanger.
- Stainless steel pre-mixing burner.
- Wet-type combustion chamber. Classe
NOx
- Ionization flame control electronic ignition. 5
- Electronically controlled continuous modulation for the heating circuit
with steady air/gas ratio.
- Natural gas or G.P.L. operation.
- Instruments for retraction unit control and regulation.
- High-prevalence circulator.
- 8 Lt. expansion tank.
- Proof combustion circuit with flue discharge electrical fan.
- Water trap siphon.
- Sanitary circulator arrangement.
- Class: NOx = 5.
- IP X4D protection degree.
- Boiler electrical kit (on demand) for combination with PAC B boilers.

• Installation and Maintenance


- Easy installation thanks to template connections and water connection
kits (on demand).
- Maintenance is made simple thanks to easy accessibility to internal
components.
• Optional accessories
- For accessories suitable for FUTURIA L boiler, see page 85.
- Flue inlet/outlet kits are not included in the supply. See accessories on
demand on page 85.

- Water connection kits are not included in


the supply. See accessories on demand on
page 85.

• Certification
- FUTURIA L boilers are EC type approved.

Heat exchanger

boiler furnace power useful efficiency Maximum heating. power Weight


type a 50/30°C a 80/60°C pressure voltage
kW kcal/h 100% 30% 100% bar V/Hz Kg
FUTURIA L 24 MT W TOP/IT 8,8÷ 25 7.568÷ 21.500 103,7 106,2 98,1 3 230/50 62
FUTURIA L 28 MT W TOP/IT 10÷ 29 8.600÷ 24.940 102,8 106,6 97,8 3 230/50 62
* Raccordi camino: scarico concentrico o scarico sdoppiato

boiler Fuel boiler 50/30°C useful power 80/60°C useful power


code type kW kcal/h kW kcal/h
00904581 natural gas FUTURIA L 24 MT W TOP/IT 9,33÷ 25,75 8.022÷ 22.145 8,98÷ 24,5 7.719÷ 21.070
00904591 LPG FUTURIA L 24 MT W TOP/IT 9,33÷ 25,75 8.022÷ 22.145 8,98÷ 24,5 7.719÷ 21.070
00904601 natural gas FUTURIA L 28 MT W TOP/IT 10,66÷ 29,81 9.168÷ 25.634 10,09÷ 28,36 8.677÷ 24.390
00904611 LPG FUTURIA L 28 MT W TOP/IT 10,66÷ 29,81 9.168÷ 25.634 10,09÷ 28,36 8.677÷ 24.390

38
Wall-hung pre-mixed condensation gas boilers

•FUTURIA L “instantaneous”
- Ultra-high efficiency proof condensation boilers, suitable for hot
sanitary water heating and supply.
- Ideal for low temperature system operation.
- Special casting aluminium corrosion proofing enbloc exchanger.
- Instantaneous exchanger for hot sanitary water with 5 Lt. micro-storage Classe
NOx
unit, complete with foamed polyurethane insulation. 5
- Stainless steel pre-mixing burner.
- Wet-type combustion chamber.
- Ionization flame control electronic ignition.
- Electronically controlled continuous modulation for the heating circuit
with steady air/gas ratio.
- Natural gas or G.P.L. operation.
- Instruments for retraction unit control and regulation.
- High-prevalence circulator.
- 8 Lt. expansion tank.
- Three-way electrical valve.
- Proof combustion circuit with flue discharge electrical fan.
- Water trap siphon
- Class: NOx = 5.
- IP X4D protection degree.

• Installation and Maintenance


- Easy installation thanks to template connections and water connection
kits (on demand).
- Maintenance is made simple thanks to easy accessibility to internal
components.
• Optional accessories
- For accessories suitable for FUTURIA L boiler, see page 85.

- Flue inlet/outlet kits are not included in the


supply. See accessories on demand on page 85.
- Water connection kits are not included in 120 93 242
the supply. See accessories on demand on
page 85.

• Certification
- FUTURIA L boilers are EC type approved.
900

190 220
450 420

Heat exchanger

boiler furnace power useful efficiency Maximum pressure power hot sanitary Weight
type a 50/30°C a 80/60°C bar voltage water supply. ΔT 30°C
kW kcal/h 100% 30% 100% risc. sanit. V/Hz l/min Kg
FUTURIA L 24 MC W TOP/IT 8,8÷ 25 7.568÷ 21.500 103,7 106,2 98,1 3 6 230/50 2,5÷ 11,7 72
FUTURIA L 28 MC W TOP/IT 10÷ 29 8.600÷ 24.940 102,8 106,6 97,8 3 6 230/50 2,5÷ 13,6 72
* Flue connections: concentric or split discharge

boiler fuel boiler 50/30°C useful power 80/60°C useful power


code type kW kcal/h kW kcal/h
00904501 natural gas FUTURIA L 24 MC W TOP/IT 9,33÷ 25,75 8.022÷ 22.145 8,98÷ 24,5 7.719÷ 21.070
00904511 LPG FUTURIA L 24 MC W TOP/IT 9,33÷ 25,75 8.022÷ 22.145 8,98÷ 24,5 7.719÷ 21.070
00904521 natural gas FUTURIA L 28 MC W TOP/IT 10,66÷ 29,81 9.168÷ 25.634 10,09÷ 28,36 8.677÷ 24.390
00904531 LPG FUTURIA L 28 MC W TOP/IT 10,66÷ 29,81 9.168÷ 25.634 10,09÷ 28,36 8.677÷ 24.390

39
Wall-hung pre-mixed condensation gas boilers

•FUTURIA L “boiler”
- Ultra-high efficiency proof condensation boilers, suitable for hot
sanitary water supply.
- Ideal for low temperature system operation.
- Special casting aluminium corrosion proofing enbloc exchanger.
- 50 Lt. storage unit stainless steel boiler, complete with foamed Classe
NOx
polyurethane insulation. 5
- Stainless steel pre-mixing burner.
- Wet-type combustion chamber.
- Ionization flame control electronic ignition.
- Electronically controlled continuous modulation for both heating
circuits with steady air/gas ratio.
- Natural gas or G.P.L. operation.
- Instruments for retraction unit control and regulation.
- High-prevalence circulator.
- 8 Lt. expansion tank.
- 2 Lt. sanitary circuit expansion tank.
- Three-way electrical valve.
- Proof combustion circuit with flue discharge electrical fan.
- Water trap siphon
- Class: NOx = 5.
- IP X4D protection degree.

• Installation and Maintenance


- Easy installation thanks to template connections and water connection
kits (on demand).
- Maintenance is made simple thanks to easy accessibility to internal
components.
• Optional accessories
- For accessories suitable for FUTURIA L boiler, see page 85.

- Flue inlet/outlet kits are not included in the


supply. See accessories on demand on page 85. 120 89 242
- Water connection kits are not included in
the supply. See accessories on demand on
page 85.

• Certification
900

- FUTURIA L boilers are EC type approved.

190 220
600 470

Heat exchanger

boiler furnace power useful efficiency Maximum pressure power hot sanitary Weight
type a 50/30°C a 80/60°C bar voltage water supply ΔT 30°C
kW kcal/h 100% 30% 100% risc. sanit. V/Hz l/h Kg
FUTURIA L 24 MB W TOP/IT 8,8÷ 25 7.568÷ 21.500 103,7 106,2 98,1 3 6 230/50 702 95
FUTURIA L 28 MB W TOP/IT 10÷ 29 8.600÷ 24.940 102,8 106,6 97,8 3 6 230/50 766 95
* Flue connections: concentric or split discharge

boiler Fuel boiler 50/30°C useful power 80/60°C useful power


code type kW kcal/h kW kcal/h
00904541 natural gas FUTURIA L 24 MB W TOP/IT 9,33÷ 25,75 8.022÷ 22.145 8,98÷ 24,5 7.719÷ 21.070
00904551 LPG FUTURIA L 24 MB W TOP/IT 9,33÷ 25,75 8.022÷ 22.145 8,98÷ 24,5 7.719÷ 21.070
00904561 natural gas FUTURIA L 28 MB W TOP/IT 10,66÷ 29,81 9.168÷ 25.634 10,09÷ 28,36 8.677÷ 24.390
00904571 LPG FUTURIA L 28 MB W TOP/IT 10,66÷ 29,81 9.168÷ 25.634 10,09÷ 28,36 8.677÷ 24.390

40
Floor-standing pre-mixed condensation gas boilers

•FUTURIA PLUS
- Ultra-high efficiency proof condensation boilers, suitable for hot
sanitary water heating and supply.
- Ideal for low temperature system operation.
- Special casting aluminium corrosion proofing enbloc exchanger.
- 90 Lt. storage unit stainless steel boiler for big amounts of hot sanitary Classe
NOx
water. 5
- Stainless steel pre-mixing burner.
- Wet-type combustion chamber.
- Ionization flame control electronic ignition.
- Electronically controlled continuous modulation for both heating
circuits with steady air/gas ratio.
- Slow opening gas valve.
- Instruments for retraction unit control and regulation.
- High-prevalence circulator.
- 8 Lt. expansion tank.
- 3 Lt. sanitary circuit expansion tank.
- Three-way electrical valve.
- Proof combustion circuit with flue discharge electrical fan.
- Water trap siphon
- Class: NOx = 5.
- IP X4D protection degree.

• Installation and Maintenance


- Easy installation thanks to template connections and water connection
kits (on demand).
- Maintenance is made simple thanks to easy accessibility to internal
components.

• Optional accessories 100


- For accessories suitable for FUTURIA PLUS boilers, see page 85. Ø 100
100 concentric
concentrico
- Flue inlet/outlet kits are not included in the supply. See accessories on
demand on page 85. Ø 60 o Ø 80 sdoppiato 343
- Water connection kits are not included in the supply. See accessories on
demand on page 85.

• Certification
- FUTURIA PLUS boilers are EC type approved.
1675

40 410

70

450 617

FUTURIA PLUS boiler

boiler furnace power useful efficiency Maximum pressure. power hot sanitary Weight
type a 50/30°C a 80/60°C bar voltage water supply ΔT 30°C
kW kcal/h 100% 30% 100% risc. sanit. V/Hz l/h Kg
FUTURIA 24 PLUS MB W TOP U/IT 8,8÷ 25 7.568÷ 21.500 103,7 106,2 98,1 3 6 230/50 680 89

boiler Fuel boiler 50/30°C useful power 80/60°C useful power


code type kW kcal/h kW kcal/h
00901041 natural gas FUTURIA 24 PLUS MB W TOP U/IT 9,33÷ 25,75 8.022÷ 22.145 8,98÷ 24,5 7.719÷ 21.070

41
Wall-hung pre-mixed condensation gas boilers

•“termo” FUTURIA N
- Ultra-high efficiency proof condensation boilers, suitable for heating.
- Ultra-high heat exchange aluminium lamellar exchanger.
- Flame injection pre-mixed ceramic burner.
- Ideal for low temperature system operation.
- Suitable for water and electrical connection to the boiler kit (boiler Classe
circulator and temperature probe). NOx
- Special casting aluminium corrosion proofing enbloc exchanger. 5
- Adjustable opening pneumatic gas valve.
- Microprocessor electronic card suitable for connection to the cascade
control board and possible external probe.
- Variable speed fan.
- Ionization flame control electronic ignition.
- Electronically controlled continuous modulation for both heating
circuits with steady air/gas ratio.
- Natural gas or G.P.L. operation.
- Instruments for retraction unit control and regulation.
- High-prevalence circulator.
- 10 Lt. expansion tank (models 15, 25 and 35).
- Check valve.
- G.P.L. kit supplied with the boiler.
- Water trap siphon
- Class: NOx = 5.
- IP X4D protection degree.

• Installation and Maintenance


- Series of modules being cascade connected can be managed and easily
assembled. The machine electronic unit is arranged for the connection
of the control room to the cascade control and managament
microprocessor.
- Easy installation thanks to template connections and water connection
kits (on demand).
- Maintenance is made simple thanks to easy accessibility to internal
components.

• Optional accessories
- For accessories suitable for FUTURIA N boiler, see page 85. Aria*
Air* B C D E
- Flue inlet/outlet kits are not included in the supply. See accessories on
demand on page 85. Aria*
Air*
- Water connection kits are not included in the supply. See accessories on Fumi*
Exaust*
demand on page 85.
- When installing a Ø60/ Ø100 concentric kit, a “flanged
800

concentric connection kit” (code 08516310) shall be assembled


between the boiler and the concentric kit.

• Certification
- FUTURIA N boilers are EC type approved.
A 410

boiler furnace power useful efficiency Maximum power A B C D E Weight


type a 50/30°C a 80/60°C pressure voltage
kW kcal/h 100% 30% 100% bar V/Hz mm. mm. mm. mm. mm. Kg
FUTURIA N 15 MT W TOP/IT 3,6÷ 15,3 3.096÷ 13.158 106,5 109 98 3 230/50 450 120 120 105 180 46,5
FUTURIA N 25 MT W TOP/IT 7,5÷ 25,2 6.450÷ 21.670 104,7 109 98 3 230/50 450 120 120 105 180 47,5
FUTURIA N 35 MT W TOP/IT 10,4÷ 34,8 8.940÷ 29.920 104,7 109,1 99,5 3 230/50 490 120 120 125 180 49,5
FUTURIA N 50 MT W TOP/IT 13,8÷ 46 11.868÷ 39.560 105,3 109 98,2 3 230/50 600 120 120 180 130 51,5
* Flue connections: concentric or split discharge

boiler Fuel boiler 50/30°C useful power 80/60°C useful power


code type kW kcal/h kW kcal/h
00905520 nat. gas/LPG FUTURIA N 15 MT W TOP/IT 3,8÷ 16,3 3.268÷ 14.018 3,5÷ 15 3.010÷ 12.900
00905560 nat. gas/LPG FUTURIA N 25 MT W TOP/IT 8÷ 26,4 6.880÷ 22.700 7,3÷ 24,7 6.280÷ 21.240
00905530 nat. gas/LPG FUTURIA N 35 MT W TOP/IT 11,1÷ 36,4 9.540÷ 31.300 10,2÷ 34,6 8.770÷ 29.750
00905550 nat. gas/LPG FUTURIA N 50 MT W TOP/IT 14,4÷ 48,4 12.384÷ 41.624 13,6÷ 45,2 11.696÷ 38.872

42
Wall-hung pre-mixed condensation gas boilers

•“instantaneous” FUTURIA N
- Ultra-high efficiency proof condensation boilers, suitable for hot
sanitary water heating and supply.
- Ultra-high heat exchange aluminium lamellar exchanger.
- Flame injection pre-mixed ceramic burner.
- Ideal for low temperature system operation. Classe
- 5 Lt. hot sanitary water micro storage unit, complete with foamed NOx
polysterene insulation. 5
- Instantaneous exchanger for plate hot sanitary water.
- Adjustable opening pneumatic gas valve.
- Microprocessor electronic card suitable for connection to the cascade
control board and possible external probe.
- Variable speed fan.
- Ionization flame control electronic ignition.
- Electronically controlled continuous modulation for both heating
circuits with steady air/gas ratio.
- Natural gas or G.P.L. operation.
- Instruments for retraction unit control and regulation.
- Sanitary and heating circuit circulators.
- 10 Lt. expansion tank.
- Check valve.
- G.P.L. kit supplied with the boiler.
- Water trap siphon
- Class: NOx = 5.
- IP X4D protection degree.

• Installation and Maintenance


- Series of modules being cascade connected can be managed and easily
assembled. The machine electronic unit is arranged for the connection
of the control room to the cascade control and managament
microprocessor.
- Easy installation thanks to template connections and water connection
kits (on demand).
- Maintenance is made simple thanks to easy accessibility to internal
components.

• Optional accessories
- For accessories suitable for FUTURIA N boiler, see page 85.
- Flue inlet/outlet kits are not included in the supply. See accessories on
demand on page 85. Aria*
Air* 120 120 A 180
- Water connection kits are not included in the supply. See accessories
on demand on page 85. Aria*
Air*
- When installing a Ø60/ Ø100 concentric kit, a “flanged
Fumi*
Exaust*
concentric connection kit” (code 08516310) shall be assembled
between the boiler and the concentric kit.
800

• Certification
- FUTURIA N boilers are EC type approved.

490 410

boiler furnace power useful efficiency Maximum pressure power hot sanitary A Weight
type a 50/30°C a 80/60°C bar voltage water supply ΔT 30°C
kW kcal/h 100% 30% 100% risc. sanit. V/Hz l/min mm. Kg
FUTURIA N 25 MC W TOP/IT 7,5÷ 25,2 6.450÷ 21.670 104,7 109 98 3 10 230/50 11,8 80 58,5
FUTURIA N 35 MC W TOP/IT 10,4÷ 34,8 8.940÷ 29.920 104,7 109,1 99,5 3 10 230/50 16,5 125 59,5
* Flue connections: concentric or split discharge

boiler Fuel boiler 50/30°C useful power 80/60°C useful power


code type kW kcal/h kW kcal/h
00907010 nat. gas/LPG FUTURIA N 25 MC W TOP/IT 8÷ 26,4 6.880÷ 22.700 7,3÷ 24,7 6.280÷ 21.240
00905540 nat. gas/LPG FUTURIA N 35 MC W TOP/IT 11,1÷ 36,4 9.540÷ 31.300 10,2÷ 34,6 8.770÷ 29.750

43
Pre-mixed condensation gas heating modules

•REPLY
- Ultra-high efficiency condensation heating module, suitable for heating
(Reply R) and hot sanitary water heating and supply (Reply C).
- Ideal for low temperature system operation.
- Special casting aluminium corrosion proofing enbloc exchangers.
- Wet-type combustion chambers. Classe
- Stainless steel pre-mixing burner. NOx
- Electronically controlled continuous modulation for both heating 5
circuits with steady air/gas ratio.
- Ionization flame control electronic ignition.
- Instruments for unit control and regulation.
- Boiler circuit high-prevalence circulator.
- Three-way electrical valve (Mod. Reply C).
- Proof combustion circuit with high-prevalence flue discharge electrical
fan.
- Water trap siphon
- Class: NOx = 5.
- IP X4D protection degree.
- Containment module structure suitable for external fitting.

• Installation and Maintenance


- Easy installation thanks to complete supply.
- Maintenance is made simple thanks to easy accessibility to internal
components.

• Optional accessories
- For the accessories suitable for REPLY heating module, see page 85.
- Discharge kits of the heating module are on demand.

• Certification
- REPLY heating modules are EC type approved.

490 230 490 230


315 480 315 480
Ø155
Ø155

200 200
255

255

Reply Reply

540

540
1800

1800

a4
a1
a3 a3
300

a5
a2
300

a6 a6
390
390

360
240
155
155

140 70 1200 140 70 1200 120


120
Reply I Reply C

module furnace power useful efficiency Maximum power Heating . Heating gas boiler boiler Cold water Weight
type a 50/30°C a 80/60°C pressure voltage delivery return conn. delivery return inlet
kW kcal/h 100% 30% 100% bar V/Hz DN a1 DN a2 Ø a3 DN a4 DN a5 Ø a6 Kg
REPLY 49 C 8,8÷ 50 7.568÷ 43.000 103,7 106,2 98,1 3 230/50 50 50 1 1/4" 50 50 3/4" 273

module Fuel module 50/30°C useful power 80/60°C useful power


code type kW kcal/h kW kcal/h
00903471 natural gas REPLY 49 C 9,33÷ 51,5 8.022÷ 44.290 8,98÷ 49 7.719÷ 42.140

44
Pre-mixed condensation gas heating modules

- REPLY C: heating module for hot water heating and supply, complete
with all the I.S.P.E.S. devices and flue discharge header (Ø 150).

* installer’s responsibility - • Accessories on demand

1 Futuria MC (Reply C) boiler 6 Air bleed automatic valve. 12 Radiators (optional).

2 Fuel on-off valve, calibrated at 98° and 7 Manual resetting regulation and safety 13 Expansion tank (optional).
I.S.P.E.S.L. type-approved. double-thermostat (I.S.P.E.S.L. type-
approved). 14 Boiler (optional).
3 Manual resetting safety pressure switch
(I.S.P.E.S.L. type-approved). 8 Heating circuit header. 15 Filling cock (optional).

4 I.S.P.E.S.L. type-approved gauge. 9 Sanitary circuit header/manifold 16 Drain cock.

5 Ø 1/2” safety valve, calibrated according to 10 Condensation discharge. 17 Three-way cock with sample flange, in
I.S.P.E.S.L. standards. compliance with I.S.P.E.S.L. standards.
11 Circulators (optional).

45
Pre-mixed condensation gas heating modules

•REPLY N
- Ultra-high efficiency condensation heating module
- Single-furnace (REPLY N 50) or double-furnace (REPLY N 70 and
REPLY N 100) with ultra-high heat exchange aluminium lamellar
exchangers.
- Flame injection pre-mixed ceramic burner. Classe
NOx
- Ideal for low temperature system operation. 5
- Ideal for outdoor installation, even for uncovered places.
- Variable opening pneumatic gas valves.
- Microprocessor electronic card suitable for connection to the cascade
control board and possible external probe.
- Variable speed fans.
- Ionization flame control electronic ignition.
- Electronically controlled continuous modulation with steady air/gas
ratio.
- Natural gas or G.P.L. operation.
- Utility interface display for each module assembled on the machine.
- Instruments for unit control and regulation.
- Independent exchanger water circuits, being connected to the relevant
delivery and return headers.
- Primary unit circulators.
- Check valve.
- Condensation discharge on disposal circuit complete with siphon.
- Silked stainless steel AISI 316 containment module structure, reduced in
size.
- G.P.L. kit supplied with the boiler.
- Class: NOx = 5.
- IP X4D protection degree.

• Installation and Maintenance


- Series of modules being cascade connected can be managed and easily 400
assembled. The machine electronic unit is arranged for the connection Øi 150 110
of the control room to the cascade control and managament
microprocessor.
- The delivery and return headers for system water delivery and return
and gas adduzione are fitted to the machine; they are flanged in order
to allow easy installation, being complete with blind flanges and
connection system.
1650

- Maintenance is made simple thanks to easy accessibility to internal a1 a3


components.
a2
• Optional accessories
575

a4
390
225

- For the accessories suitable for REPLY N heating module, see page 85.
145

• Certification 700 35
- REPLY N heating modules are EC type approved. 115
250
275

module furnace power useful efficiency Maximum power Heating Heating gas condensation Weight
type a 50/30°C a 80/60°C pressure voltage delivery return conn. discharge
kW kcal/h 100% 30% 100% bar V/Hz DN a1 DN a2 DN a3 Ø a4 Kg
REPLY N 50 13,8÷ 46 11.868÷ 39.560 105,3 109 98,2 6 230/50 80 80 50 40 114
REPLY N 70 13,8÷ 70 11.868÷ 60.200 105,3 109 98,2 6 230/50 80 80 50 40 165
REPLY N 100 13,8÷ 92 11.868÷ 79.120 105,3 109 98,2 6 230/50 80 80 50 40 165

module Fuel module 50/30°C useful power 80/60°C useful power


code type kW kcal/h kW kcal/h
00906210 nat. gas/LPG REPLY N 50 14,4÷ 48,4 12.384÷ 41.624 13,6÷ 45,2 11.696÷ 38.872
00906220 nat. gas/LPG REPLY N 70 14,4÷ 73,7 12.384÷ 63.382 13,6÷ 68,7 11.696÷ 59.082
00906230 nat. gas/LPG REPLY N 100 14,4÷ 96,8 12.384÷ 83.248 13,6÷ 90,4 11.696÷ 77.744

46
Pre-mixed condensation gas heating modules

• Cascade connection
- REPLY N is a heating module intended for single or cascade operation. Two or more REPLY modules can be cascade connected (5
heating modules at maximum), as shown in the figure below.

Attacco
gas Gas
connection
delivery
Mandata
return
Ritorno

Reply N modules necessary control rooms


n° n°
A cascade control room is available on demand, allowing advanced management of the two 2 1
shells inside the boiler. Each control room is capable of controlling a maximum of 5 3 2
furnaces. As a consequence the number of control rooms being necessary for such
4 2
operation changes depending on the number of REPLY N modules connected (see table on
5 2
your right).
6 3
- -
- -

• Flue
- For cascade connection of more than one module, connect the flue outlet (Ø 150) of each single module as shown in the figure, making
sure that the header and flue diameter values correspond to those reported in the table below.

Warning: The header shall feature a slope towards the


condensation discharge amounting to at least 3°.
Ø

150

Reply N modules Header/flue


n° Ø mm
1 150
2 200
3 250
4 300
5 350

47
Wall-hung indoor gas boilers

•“ultra low emission” XILO LN


- Proof boiler suitable for hot sanitary water heating and supply.
- Low NOx emission water cooling burner, in stainless steel for all kinds
of gas.
- Reduced overall dimensions (-20% if compared to the standard
boilers). Classe
NOx
- High-efficiency primary copper exchanger. 5
- Instantaneous exchanger for plate hot sanitary water.
- Ionization flame control electronic ignition.
- Electronically controlled proportional modulation for sanitary and
heating circuits.
- Proof combustion circuit with flue discharge electrical fan.
- By-pass.
- High-prevalence circulator.
- 8 Lt. expansion tank.
- Three-way electrical diverting valve.
- Slow opening gas valve.
- Combustion chamber provided with ceramic fibre insulation.
- Instruments for unit control and regulation.
- Flue standard intake in the boiler (mod. MCS).
- Precedence flow meter.
- Class: NOx = 5.
- IP X4D protection degree.

• Installation and Maintenance


- Easy installation thanks to template connections and water connection
kits (on demand).
- Maintenance is made simple thanks to easy accessibility to internal
components.
220
• Optional accessories A 160
- For accessories suitable for XILO LN boiler, see page 85.
- Flue inlet/outlet kits are not included in the supply. See accessories on
demand on page 85.

• Certification
- XILO LN boilers are EC type approved.
770

440 330

97
250

Water cooling burner

boiler furnace power useful efficiency Maximum pressure power voltage hot sanitary A Weight
type % bar water supply ΔT 30°C
kW kcal/h 100 % 30 % risc. sanit. V/Hz l/min. Ø mm kg
XILO LN 20 MCS W TOP/IT 25 21.500 93,9 92,5 3 8 230/50 2,5÷ 11,2 * 43
* Flue connections: concentric or split discharge

boiler fuel boiler useful power


code type kW kcal/h
00903450 natural gas XILO LN 20 MCS W TOP/IT 12,9÷ 23,4 11.094÷ 20.124
00903460 LPG XILO LN 20 MCS W TOP/IT 12,9÷ 23,4 11.094÷ 20.124

48
Wall-hung indoor gas boilers

•XILO T
- Open (mod. M) and proof chamber (mod. MS) boilers suitable for
heating.
- Suitable for low temperature system operation.
- Reduced overall dimensions (-20% if compared to the standard
boilers).
- High-efficiency primary copper exchanger.
- Atmospheric burner, in stainless steel for all kinds of gas.
- Ionization flame control electronic ignition.
- Electronically controlled proportional modulation for heating circuit.
- Proof combustion circuit with flue discharge electrical fan (mod. MS).
- Safety FLUE CONTROL preventing burnt gases from entering the
room (mod. M).
- High-prevalence circulator.
- 8 Lt. expansion tank.
- Slow opening gas valve.
- Combustion chamber provided with ceramic fibre insulation.
- Instruments for unit control and regulation.
- Flue standard intake in the boiler (mod. MCS).
- IP X4D protection degree.
- XILO T 24 boilers can be combined with PAC B boilers.
220
• Installation and Maintenance A 160
- Easy installation thanks to template connections and water connection
kits (on demand).
- Maintenance is made simple thanks to easy accessibility to internal
components.

• Optional accessories
770

- For accessories suitable for XILO T boiler, see page 85.


- Flue inlet/outlet kits are not included in the supply. See accessories on
demand on page 85.

• Certification
- XILO T boilers are EC type approved. 440 330

97
250

XILO T MS
dimensions

boiler furnace power useful efficiency Maximum heating power voltage A Weight
type % circuit pressure
kW kcal/h 100 % 30 % bar V/Hz Ø mm kg
XILO T 20 M W TOP U/IT 26 22.360 91 88,7 3 230/50 132,5 33
XILO T 20 MS W TOP U/IT 26 22.360 91,3 89 3 230/50 * 35
XILO T 24 M W TOP U/IT 30,2 25.972 91,2 90 3 230/50 152,5 34
XILO T 24 MS W TOP U/IT 30,2 25.972 91 88,9 3 230/50 * 36
* Flue connections: concentric or split discharge

boiler Fuel boiler Useful power


code type kW kcal/h
00903121 natural gas XILO T 20 M W TOP U/IT 10,62÷ 23,66 9.133÷ 20.348
00903131 LPG XILO T 20 M W TOP U/IT 10,62÷ 23,66 9.133÷ 20.348
00903002 natural gas XILO T 20 MS W TOP U/IT 10,47÷ 23,73 9.004÷ 20.407
00903012 LPG XILO T 20 MS W TOP U/IT 10,47÷ 23,73 9.004÷ 20.047
00903141 natural gas XILO T 24 M W TOP U/IT 12,56÷ 27,54 10.804÷ 23.686
00903151 LPG XILO T 24 M W TOP U/IT 12,56÷ 27,54 10.804÷ 23.686
00903161 natural gas XILO T 24 MS W TOP U/IT 11,94÷ 27,48 10.268÷ 23.633
00903171 LPG XILO T 24 MS W TOP U/IT 11,94÷ 27,48 10.268÷ 23.633

49
Wall-hung indoor gas boilers

•“bithermal compact” XILO


- Open (mod. MC) and proof chamber (mod. MCS) boilers suitable for
hot sanitary water heating and supply.
- Suitable for low temperature system operation.
- Reduced overall dimensions (-20% if compared to the standard
boilers).
- High-efficiency bi-thermal copper exchanger.
- Atmospheric burner, in stainless steel for all kinds of gas.
- Ionization flame control electronic ignition.
- Electronically controlled proportional modulation for heating and
sanitary circuit.
- Proof combustion circuit with flue discharge electrical fan (mod. MCS).
- Safety FLUE CONTROL preventing burnt gases from entering the
room (mod. MC).
- Slow opening gas valve.
- Combustion chamber provided with ceramic fibre insulation.
- High-prevalence circulator.
- 8 Lt. expansion tank.
- Instruments for unit control and regulation.
- Flue standard intake in the boiler (mod. MCS).
- Precedence flow meter.
- IP X4D protection degree.

• Installation and Maintenance


- Easy installation thanks to template connections and water connection
kits (on demand). 220
- Maintenance is made simple thanks to easy accessibility to internal A 160
components.

• Optional accessories
- For accessories suitable for XILO boiler, see page 85.
- Flue inlet/outlet kits are not included in the supply. See accessories on
770

demand on page 85.


- Polyphosphate doser of the DPO/B type.

• Certification
- XILO boilers are EC type approved.
440 330

97

- In the presence of hard water it is


250

recommended to assemble a XILO MCS


polyphosphate proportional doser at the dimensions
boiler cold water inlet.

boiler furnace power useful efficiency Maximum pressure power hot sanitary A Weight
type % bar voltage water supply ΔT 30°C
kW kcal/h 100 % 30 % risc. sanit. V/Hz l/min. Ø mm kg
XILO 20 MC W TOP U/IT 25 21.500 90 87,3 3 8 230/50 2,5÷ 10,8 132,5 38
XILO 20 MCS W TOP U/IT 25 21.500 91 87,3 3 8 230/50 2,5÷ 11 * 40
* Flue connections: concentric or split discharge

boiler Fuel boiler Useful power


code type kW kcal/h
00902951 natural gas XILO 20 MC W TOP U/IT 8,45÷ 22,5 7.267÷ 19.350
00902961 LPG XILO 20 MC W TOP U/IT 8,45÷ 22,5 7.267÷ 19.350
00902604 natural gas XILO 20 MCS W TOP U/IT 8,31÷ 22,75 7.146÷ 19.565
00902904 LPG XILO 20 MCS W TOP U/IT 8,31÷ 22,75 7.146÷ 19.565

50
Wall-hung indoor gas boilers

•“monothermal compact” XILO D


- Open (mod. MC) and proof chamber (mod. MCS) boilers suitable for
hot sanitary water heating and supply.
- Suitable for low temperature system operation.
- Reduced overall dimensions (-20% if compared to the standard
boilers).
- High-efficiency primary copper exchanger.
- Instantaneous exchanger for plate hot sanitary water.
- Atmospheric burner, in stainless steel for all kinds of gas.
- Ionization flame control electronic ignition.
- Electronically controlled proportional modulation for heating and
sanitary circuit.
- Proof combustion circuit with flue discharge electrical fan (mod. MCS).
- Safety FLUE CONTROL preventing burnt gases from entering the
room (mod. MC).
- By-pass.
- High-prevalence circulator.
- 8 Lt. expansion tank.
- Three-way electrical diverting valve.
- Slow opening gas valve.
- Combustion chamber provided with ceramic fibre insulation.
- Instruments for unit control and regulation. 220
- Flue standard intake in the boiler (mod. MCS).
A 160
- Precedence flow meter.
- IP X4D protection degree.

• Installation and Maintenance


- Easy installation thanks to template connections and water connection
kits (on demand).
770

- Maintenance is made simple thanks to easy accessibility to internal


components.

• Optional accessories
- For accessories suitable for XILO D boiler, see page 85.
- Flue inlet/outlet kits are not included in the supply. See accessories on 440 330
demand on page 85.
97

• Certification
250

XILO D MCS
- XILO D boilers are EC type approved.
dimensions

boiler furnace power useful efficiency Maximum pressure power hot sanitary A Weight
type % bar voltage water supply ΔT 30°C
kW kcal/h 100 % 30 % risc. sanit. V/Hz l/min. Ø mm kg
XILO D 20 MC W TOP U/IT 26 22.360 91 88,7 3 8 230/50 2,5÷ 11,3 132,5 39
XILO D 20 MCS W TOP U/IT 26 22.360 91,3 89 3 8 230/50 2,5÷ 11,3 * 41
XILO D 24 MC W TOP U/IT 30,2 25.972 91,2 90 3 8 230/50 2,5÷ 13,2 152,5 40
XILO D 24 MCS W TOP U/IT 30,2 25.972 91 88,9 3 8 230/50 2,5÷ 13,1 * 42
* Flue connections: concentric or split discharge

boiler Fuel boiler Useful power


code type kW kcal/h
00902911 natural gas XILO D 20 MC W TOP U/IT 10,62÷ 23,66 9.133÷ 20.348
00902921 LPG XILO D 20 MC W TOP U/IT 10,62÷ 23,66 9.133÷ 20.348
00902862 natural gas XILO D 20 MCS W TOP U/IT 10,47÷ 23,73 9.004÷ 20.047
00902872 LPG XILO D 20 MCS W TOP U/IT 10,47÷ 23,73 9.004÷ 20.047
00902931 natural gas XILO D 24 MC W TOP U/IT 12,56÷ 27,54 10.804÷ 23.686
00902941 LPG XILO D 24 MC W TOP U/IT 12,56÷ 27,54 10.804÷ 23.686
00902882 natural gas XILO D 24 MCS W TOP U/IT 11,94÷ 27,48 10.268÷ 23.633
00902882 LPG XILO D 24 MCS W TOP U/IT 11,94÷ 27,48 10.268÷ 23.633

51
Wall-hung indoor gas boilers

•“wall-hung boiler” VELA XN


- High-efficiency open (mod. MB) and proof chamber (mod. MBS)
boilers suitable for hot sanitary water heating and supply.
- 60 Lt. storage unit stainless steel boiler.
- Copper exchanger.
- Atmospheric burner, in stainless steel for all kinds of gas.
- Combustion chamber provided with ceramic fibre insulation.
- Ionization flame control electronic ignition.
- Electronically controlled proportional modulation for heating and
sanitary circuit.
- Suitable for low temperature system operation.
- Proof combustion circuit with flue discharge electrical fan (mod. MBS).
- Safety FLUE CONTROL preventing burnt gases from entering the
room (mod. MB).
- Slow opening gas valve.
- 8 Lt. expansion tank.
- 2 Lt. sanitary circuit expansion tank.
- High-prevalence circulator.
- Three-way electrical valve.
- Instruments for unit control and regulation.
- Flue standard intake in the boiler (mod. MBS).
- “antilegionella” function.
- By-pass.
- IP X4D protection degree.
B
• Installation and Maintenance A C
- Easy installation thanks to template connections and water
connection kits (on demand).
- Maintenance is made simple thanks to easy accessibility to internal
components.
900

• Optional accessories
- For accessories suitable for VELA XN boiler, see page 85.
- Flue inlet/outlet kits are not included in the supply. See accessories on
demand on page 85. CALORECLIMA

• Certification 600 440


– VELA XN boilers are EC type approved.
195
122

VELA XN
dimensions
**

boiler furnace power useful efficiency Maximum pressure power hot sanitary A B C Weight
type % bar voltage water supply ΔT 30°C
kW kcal/h 100% 30% risc. sanit. V/Hz l/min Ø mm. mm. mm. Kg
VELA XN 24 MB W TOP/IT 26 22.360 90 86,8 3 8 230/50 11,2 132,5 130 220 64
VELA XN 24 MBS W TOP/IT 26 22.360 92 88,7 3 8 230/50 11,4 * 94,5 222 69
* Flue connections: concentric or split discharge - ** Air suction Ø80.

boiler Fuel boiler Useful power


code type kW kcal/h
00906240 natural gas VELA XN 24 MB W TOP/IT 10,43÷ 23,4 8.970÷ 20.124
00906500 LPG VELA XN 24 MB W TOP/IT 10,43÷ 23,4 8.970÷ 20.124
00906250 natural gas VELA XN 24 MBS W TOP/IT 10,5÷ 23,92 9.030÷ 20.571
00906510 LPG VELA XN 24 MBS W TOP/IT 10,5÷ 23,92 9.030÷ 20.571

52
Wall-hung indoor gas boilers

•“wall-hung boiler” ALMA


- High-efficiency open (mod. MB) and proof chamber (mod. MBS)
boilers suitable for hot sanitary water heating and supply.
- 50 Lt. storage unit stainless steel boiler.
- Copper exchanger.
- Atmospheric burner, in stainless steel for all kinds of gas.
- Combustion chamber provided with ceramic fibre insulation.
- Ionization flame control electronic ignition.
- Electronically controlled proportional modulation for heating and
sanitary circuit.
- Suitable for low temperature system operation.
- Proof combustion circuit with flue discharge electrical fan (mod.
MBS).
- Safety FLUE CONTROL preventing burnt gases from entering the
room (mod. MB).
- Slow opening gas valve.
- 8 Lt. heating unit expansion tank.
- 2 Lt. sanitary circuit expansion tank.
- High-prevalence circulator.
- Three-way electrical valve.
- Electronic control panel.
- Heating and sanitary temperature regulation.
- Flue standard intake in the boiler (mod. MBS).
- Defect display. B
- Anti-freeze function. A C
- Post circulation function.
- “antilegionella” function.
- By-pass.
- IP X4D protection degree.
- A digital time and date clock can be fitted.
900

• Installation and Maintenance


- Easy installation thanks to template connections and water connection
kits (on demand).
- Maintenance is made simple thanks to easy accessibility to internal
components.
600 470
• Optional accessories
- For accessories suitable for ALMA boiler, see page 85.
232
- Flue inlet/outlet kits are not included in the supply. See accessories on
demand on page 85.
122

ALMA MBS
• Certification
dimensions
- ALMA boilers are EC type approved.

Attacchi: vedi dima a pag. 79.


boiler furnace power useful efficiency Max. pressure power hot sanitary A B C Weight
type % bar voltage water supply ΔT 30°C
kW kcal/h 100 % 30 % risc. sanit. V/Hz l/min. Ø mm mm mm kg
ALMA 24 MB W TOP/IT 26 22.360 90 86,8 3 8 230/50 11,2 132,5 173 222 70
ALMA 24 MBS W TOP/IT 26 22.360 92 88,7 3 8 230/50 11,4 * 132 222 75
ALMA 28 MB W TOP/IT 30,2 25.972 90,2 86,9 3 8 230/50 13 152,5 173 222 70
ALMA 28 MBS W TOP/IT 30,45 26.187 91,2 88,9 3 8 230/50 13,3 * 132 222 75
ALMA 32 MBS W TOP/IT 34,5 29.670 92,5 88,9 3 8 230/50 15,2 * 132 222 75
* Flue connections: concentric or split discharge - ** Air suction Ø80.

boiler Fuel boiler Useful power


code type kW kcal/h
00905330 natural gas ALMA 24 MB W TOP/IT 10,43÷ 23,4 8.970÷ 20.124
00905340 LPG ALMA 24 MB W TOP/IT 10,43÷ 23,4 8.970÷ 20.124
00905310 natural gas ALMA 24 MBS W TOP/IT 10,5÷ 23,92 9.030÷ 20.571
00905320 LPG ALMA 24 MBS W TOP/IT 10,5÷ 23,92 9.030÷ 20.571
00905370 natural gas ALMA 28 MB W TOP/IT 12,2÷ 27,24 10.492÷ 23.426
00905380 LPG ALMA 28 MB W TOP/IT 12,2÷ 27,24 10.492÷ 23.426
00905350 natural gas ALMA 28 MBS W TOP/IT 12,16÷ 27,8 10.458÷ 23.908
00905360 LPG ALMA 28 MBS W TOP/IT 12,16÷ 27,8 10.458÷ 23.908
00908140 natural gas ALMA 32 MBS W TOP/IT 14÷ 31,9 12.040÷ 27.434
00908150 LPG ALMA 32 MBS W TOP/IT 14÷ 31,9 12.040÷ 27.434

53
54
Water heaters and floor-standing gas boilers

Indoor floor-standing gas boilers


ERA F
ERA F S
ERA F 60
ERA F 90
“small-sized” GASTER N – “big-sized” GASTER N
Instantaneous gas water heaters
SIL
Storage gas water heaters
SAL S 80-120 – SAL S 150-180
SAL S 200-300-400
SAL 200-300-400
Zone management devices
BOX ZONE
In compliance with:
DIRECTIVE 90/396/EEC (BOX ZONE not included)
DIRECTIVE E.M.C. 89/336/EEC (Act No. 476 of the 04/12/92) (BOX ZONE not included)
DIRECTIVE L.V. 72/23/EEC (Act No. 791 of 18/10/77) (BOX ZONE not included)
EFFICIENCY DIRECTIVE 92/42/EEC (SIL, SAL S, SAL and BOX ZONE not included)

ERA F
ERA FS
ERA F 60
ERA F 90
GASTER N
SIL
SAL S
SAL
4,7 8 23 23,7 27,49 27,8 28 28,02 30,3 31,9 32 51 56 289
kW
55
Indoor floor-standing gas boilers

•“cast iron basement” ERA F


- High-efficiency open chamber boilers suitable for heating.
- Cast iron shell with transversal arranged components.
- Atmospheric burner, in stainless steel for all kinds of gas.
- Intermittent pilot electronic ignition with ionization flame control.
- Instruments for unit control and regulation.
- Aluminate built-in antireflouleur.
- Safety FLUE CONTROL preventing burnt gases from entering the
room (mod. MB).
- Slow opening gas valve.
- High-prevalence circulator (mod. PK).
- 10 Lt. expansion tank (mod. PK).
- Safety valve (mod. PK).
- Air bleed automatic valve (mod. PK).
- Filling cock (mod. PK).
- Boiler outlet cock.
- ERA F boilers can be combined with PAC B boilers

• Installation and Maintenance


- Maintenance is made simple thanks to easy accessibility to internal
components (front door).

• Optional accessories
- For accessories suitable for ERA F boiler, see page 85.

• Certification
- ERA F boilers are EC type approved.

E F E 80

C B C
a1 a2 a1
a3
a3
850

850

D
B D
617
582

582

a2
530

F
a4
182

133
A 615 A 615
ERA F 23 - ERA F 32 - ERA F 45 - ERA F 56 ERA F 32 PK

* = 480 mm (ERA F 23 - ERA F 45 - ERA F 56) - 530 mm (ERA F 32)

boiler furnace power useful efficiency Maximum power A B C D E F Heating Heating gas Cold water Weight
type % pressure voltage delivery return conn. inlet
kW kcal/h 100 % 30 % bar V/Hz mm. mm. mm. mm. mm. mm. Ø a1 Ø a2 Ø a3 Ø a4 kg
ERA F 23 10,1÷ 25,3 8.686÷ 21.758 90,9 92 4 230/50 450 137 134 65 130 70 3/4” 3/4” 1/2” - 139
ERA F 32 14,9÷ 34,9 12.814÷ 30.014 91,7 92,5 4 230/50 450 94 91 22 150 80 3/4” 3/4” 1/2” - 165
ERA F 45 19,7÷ 49,5 16.942÷ 42.570 90,9 92,1 4 230/50 600 126 123 86 150 80 3/4” 3/4” 1/2” - 190
ERA F 56 24,5÷ 61,6 21.070÷ 52.976 90,9 92,1 4 230/50 600 83 80 40 180 95 3/4” 3/4” 1/2” - 216
model equipped with circulator and expansion tank
ERA F 32 PK 14,9÷ 34,9 12.814÷ 30.014 91,7 92,5 4 230/50 450 94 91 22 150 33 3/4” 3/4” 1/2” 1/2” 175

boiler boiler Useful power


code type kW kcal/h
00906260 ERA F 23 8,8÷ 23 7.568÷ 19.780
00906270 ERA F 32 13÷ 32 11.180÷ 27.520
00906280 ERA F 45 17,2÷ 45 14.792÷ 38.700
00906290 ERA F 56 21,6÷ 56 18.576÷ 48.160
model equipped with circulator and expansion tank
00906300 ERA F 32 PK 13÷ 32 11.180÷ 27.520

56
Indoor floor-standing gas boilers

•“cast iron, proof” ERA F S


- High-efficiency proof boilers only suitable for heating.
- Cast iron shell with transversal arranged components.
- Stainless steel atmospheric burner for all kinds of gas.
- Intermittent pilot electronic ignition with ionization flame control.
- Instruments for unit control and regulation.
- Proof combustion unit with flue exhaust electrical fan.
- Slow opening gas valve.
- High-prevalence circulator (mod. PK).
- 10 Lt. expansion tank (mod. PK).
- Safety valve (mod. PK).
- Air bleed automatic valve (mod. PK).
- Filling cock (mod. PK).
- Boiler outlet cock.
- ERA F S boilers can be combined with PAC B boilers

• Installation and Maintenance


- Maintenance is made simple thanks to easy accessibility to internal
components (front door).

• Optional accessories
- For accessories suitable for ERA F S boiler, see page 85.
- Flue suction/exhaust kits are not included in the supply

• Certification
- ERA F S boilers are EC type approved.

120 157

40
a1 a7 a6
55 55

a3
850

a2
708
a4 a5
439
182
84

50
500 600
163

boiler furnace power useful efficiency Heating max. power Heating Heating gas Cold water boiler Flue Air Weight
type % pressure voltage delivery return conn. inlet return exhaust suction
kW kcal/h 100 % 30 % bar V/Hz Ø a1 Ø a2 Ø a3 Ø a4 Ø a5 Ø a6 Ø a7 kg
ERA F 32 S 15,9÷ 34,9 13.674÷ 30.014 91,7 90,5 4 230/50 3/4” 3/4” 1/2” - - * 80 170
model equipped with circulator and expansion tank
ERA F 32 S PK 15,9÷ 34,9 13.674÷ 30.014 91,7 90,5 4 230/50 3/4” 3/4” 1/2” 1/2” 1” * 80 180
* Flue connections: concentric or split discharge

boiler boiler Useful power


code type kW kcal/h
00906310 ERA F 32 S* 11÷ 32 9.460÷ 27.520
model equipped with circulator and expansion tank
00903500 ERA F 32 S PK* 11÷ 32 9.460÷ 27.520

57
Indoor floor-standing gas boilers

•“cast iron boiler” ERA F 60


- High-efficiency open chamber (mod. B) and proof (mod. BS) boilers
suitable for hot sanitary water heating and supply.
- Stainless steel boiler, covered with 55 Lt. high-density polystyrene
coating.
- Cast iron shell with transversal arranged components.
- Stainless steel atmospheric burner for all kinds of gas.
- Instruments for unit control and regulation.
- Intermittent pilot electronic ignition with ionization flame control.
- Flue exhaust electrical fan (mod. BS).
- Safety FLUE CONTROL preventing burnt gases from entering the
room (mod. B).
- Slow opening gas valve.
- Heating circuit high-prevalence circulator.
- Heating circuit 10 Lt. expansion tank.
- Sanitary circuit 2 Lt. expansion tank.
- Safety valve.
- Air bleed automatic valve.
- Filling cock.
- Boiler outlet cock.

• Installation and Maintenance


- Maintenance is made simple thanks to easy accessibility
to internal components (front door). 208
80 50505050 88 Ø153

a3
• Optional accessories a1
a5
850

- For accessories suitable for ERA F 60 boiler, see page 85.

785
a6
- Flue suction/exhaust kits are not included in the supply
a4
a2
• Certification
- ERA F 60 boilers are EC type approved. 800 600

ERA F 32 B 60

80 50505050 88 120 157

40
a3
a1
a5 a8 a7
850

785

a6
707

a4
a2

800 600
ERA F 32 BS 60

boiler furnace power useful Maximum power hot sanitary water Heating gas Cold water inletRicirc. Flue Air Weight
type efficiency % pressure bar voltage supply ΔT 30°C delivery/return conn.Hot water outlet exhaust suction
kW kcal/h 100 % 30 % risc. sanit. V/Hz l/h Ø a1/Ø a2 Ø a3 Ø a4/Ø a5 Ø a6 Ø a7 Ø a8 kg
ERA F 32 B 60 14,9÷ 34,9 12.814÷ 30.014 91,7 92,5 4 7 230/50 800 3/4” 1/2” 1/2” 1/2” - - 179
Proof model
ERA F 32 BS 60 15,9÷ 34,9 13.674÷ 30.014 91,7 90,5 4 7 230/50 800 3/4” 1/2” 1/2” 1/2” * 80 175
* Flue connections: concentric or split discharge

boiler boiler Useful power


code type kW kcal/h
00906320 ERA F 32 B 60* 13÷ 32 11.180÷ 27.520
Proof model
00906330 ERA F 32 BS 60* 14÷ 32 12.040÷ 27.520

58
Indoor floor-standing gas boilers

•“cast iron boiler” ERA F 90


- High-efficiency open chamber (mod. B) and proof (mod. BS) boilers
suitable for hot sanitary water heating and supply.
- Stainless steel boiler, covered with 90 Lt. high-density polystyrene
coating.
- Suitable for managing another high-temperature zone.
- Cast iron shell with transversal arranged components.
- Stainless steel atmospheric burner for all kinds of gas.
- Instruments for unit control and regulation.
- Intermittent pilot electronic ignition with ionization flame control.
- Flue exhaust electrical fan (mod. BS).
- Safety FLUE CONTROL preventing burnt gases from entering the
room (mod. B).
- Slow opening gas valve.
- Heating circuit high-prevalence circulator.
- Heating circuit 10 Lt. expansion tank.
- Sanitary circuit 2 Lt. expansion tank.
- Safety valve.
- Air bleed automatic valve.
- Filling cock.
- Boiler outlet cock.

• Installation and Maintenance


- Maintenance is made simple thanks to easy accessibility to internal
components (front door).

• Optional accessories
- For accessories suitable for ERA F 90 boiler, see page 85.
- Flue suction/exhaust kits are not included in the supply

• Certification
- ERA F 90 boilers are EC type approved.

106 45 Ø150 68 120 140

a1

40
a1 a3
a3 a2 a8 a7

a2
1400
1400

1190
1100

1064
976
921
940

a5 a5
655

a6 a6
422
422

252
252
82

82

a4 a4
500 706 500 706

ERA F 32 B 90 ERA F 32 BS 90

boiler furnace power useful Maximum power hot sanitary water Heating delivery gas Cold water inlet Hot water Flue Air Weight
type efficiency % pressure bar voltage supply ΔT 30°C Heating return conn. Hot water outlet tank ricirc. exhaust suction
kW kcal/h 100 % 30 % risc. sanit. V/Hz l/h Ø a1/Ø a2 Ø a3 Ø a4/Ø a5 Ø a6 Ø a7 Ø a8 kg
ERA F 32 B 90 14,9÷ 34,9 12.814÷ 30.014 91,7 92,5 4 7 230/50 800 1” 1/2” 3/4” 3/4” - - 200
Proof model
ERA F 32 BS 90 15,9÷ 34,9 13.674÷ 30.014 91,7 90,5 4 7 230/50 800 1” 1/2” 3/4” 3/4” * 80 206
* Flue connections: concentric or split discharge

boiler boiler Useful power


code type kW kcal/h
00906340 ERA F 32 B 90* 13÷ 32 11.180÷ 27.520
Proof model
00906350 ERA F 32 BS 90* 14÷ 32 12.040÷ 27.520

59
Indoor floor-standing gas boilers

•“two-stage cast iron” GASTER N


- High-efficiency open chamber boilers only suitable for heating.
- Cast iron shell with transversal arranged components.
- Two-stage operation.
- Stainless steel atmospheric burner for all kinds of gas.
- Intermittent pilot electronic ignition with ionization flame control.
- Aluminate built-in antirefouleur.
- Safety FLUE CONTROL preventing burnt gases from entering the
room (models 51 and 68).
- Main gas and safety valves.
- Instruments for unit control and regulation.
- Boiler outlet cock.
- Painted plate covering
- Thermal regulation allowed.
- GASTER N boilers can be combined with PAV N boilers

• Installation and Maintenance


- Two or three on-line arranged boilers featuring the same power can be
managed, being controlled by the cascade control board.
- Maintenance is made simple thanks to easy accessibility to internal
components (front door).

• Optional accessories
- For accessories suitable for GASTER N boiler, see page 85.

• Certification
- GASTER N boilers are EC type approved.

B C

D
a3

a1
1000

762
672

a2
E
222

A 900

boiler first furnace useful Heating max. power A B C D E Heating Heating gas Weight
type stage power efficiency pressure voltage delivery return conn.
furnace power %
kW kcal/h kW kcal/h 100 % 30 % bar V/Hz mm. mm. mm. mm. mm. Ø a1 Ø a2 Ø a3 kg
GASTER N 51 AW 32,7 28.122 56 48.160 91,1 92,3 6 230/50 550 103,5 180 43 35 1 1/2” 1 1/2” 3/4” 214
GASTER N 68 AW 46,6 37.496 74,8 64.328 90,9 92,3 6 230/50 640 103,5 180 46 38 1 1/2” 1 1/2” 3/4” 252
GASTER N 85 AW 54,5 46.870 93,5 80.410 90,9 92,3 6 230/50 720 113,5 200 44 36 1 1/2” 1 1/2” 3/4” 300
GASTER N 102 AW 65,4 56.244 112 96.320 91,1 92,3 6 230/50 800 113,5 200 42 34 1 1/2” 1 1/2” 3/4” 348

boiler boiler first stage useful power Useful power


code type kW kcal/h kW kcal/h
00906360 GASTER N 51 AW 30 25.800 51 43.860
00906370 GASTER N 68 AW 39,5 33.970 68 58.480
00099251 GASTER N 85 AW 49,5 42.570 85 73.100
00099261 GASTER N 102 AW 59,5 51.170 102 87.720

60
Indoor floor-standing gas boilers

•“two-stage cast iron” GASTER N


- High-efficiency open chamber boilers only suitable for heating.
- Cast iron shell with transversal arranged components.
- Two-stage operation.
- Stainless steel atmospheric burner for all kinds of gas.
- Intermittent pilot electronic ignition with ionization flame control.
- Aluminate built-in antirefouleur.
- Safety FLUE CONTROL preventing burnt gases from entering the
room (models 51 and 68).
- Main gas and safety valves.
- Instruments for unit control and regulation.
- Boiler outlet cock.
- Painted plate covering
- Thermal regulation allowed.
- GASTER N boilers can be combined with PAV N boilers

• Installation and Maintenance


- Two or three on-line arranged boilers featuring the same power can be
managed, being controlled by the cascade control board.
- Maintenance is made simple thanks to easy accessibility to internal
components (front door).

• Optional accessories
- For accessories suitable for GASTER N boiler, see page 85.

• Certification
- GASTER N boilers are EC type approved. B C

E
a1
1050

a3
a2
672
567

D
222

A F

boiler first stage furnace useful Heating max. power A B C D E F Heating Heating gas Weight
type furnace power efficiency pressure voltage delivery return conn.
power %
kW kcal/h kW kcal/h 100 % 30 % bar V/Hz mm. mm. mm. mm. mm. mm. Ø a1 Ø a2 Ø a3 kg
GASTER N 119 AW 77 66.220 131 112.660 91,2 92,3 6 230/50 930 133 220 50 42 1.050 2” 2” 1” 430
GASTER N 136 AW 89 76.540 149 128.140 91,3 92,2 6 230/50 1.020 148 250 53 45 1.050 2” 2” 1” 490
GASTER N 153 AW 100 86.000 168 144.480 91,4 92,2 6 230/50 1.100 148 250 58 43 1.050 2” 2” 1 1/2” 535
GASTER N 170 AW 110 94.600 187 160.820 91,5 92,1 6 230/50 1.190 173 300 60 46 1.050 2” 2” 1 1/2” 575
GASTER N 187 AW 122 104.920 206 177.160 91,6 92,1 6 230/50 1.270 173 300 58 44 1.050 2” 2” 1 1/2” 625
GASTER N 221 AW 144 123.840 243 208.980 91,7 92 6 230/50 1.440 173 300 57 45 1.050 2” 2” 1 1/2” 720
GASTER N 255 AW 166 142.760 280 240.800 91,9 91,9 6 230/50 1.610 198 350 62 46 1.100 2” 2” 1 1/2” 835
GASTER N 289 AW 188 161.680 317 272.620 92 91,7 6 230/50 1.780 198 350 66 49 1.100 2” 2” 1 1/2” 905

boiler boiler first stage useful power Useful power


code type kW kcal/h kW kcal/h
00099271 GASTER N 119 AW 71 61.060 119 102.340
00099281 GASTER N 136 AW 82 70.520 136 116.960
00099291 GASTER N 153 AW 92 79.120 153 131.580
00099301 GASTER N 170 AW 102 87.720 170 146.200
00099311 GASTER N 187 AW 112 96.320 187 160.820
00906380 GASTER N 221 AW 133 114.380 221 190.060
00906390 GASTER N 255 AW 153 131.580 255 219.300
00906400 GASTER N 289 AW 173 148.780 289 248.540

61
Instantaneous gas water heaters

•SIL
- High-efficiency open chamber (mod. SIL 14 top) and proof (mod. SIL
14S top) water heaters suitable for hot sanitary water supply.
- High-efficiency copper exchanger.
- Electronic ignition with ionization flame control.
- Stainless steel atmospheric burner for all kinds of gas.
- Proof combustion circuit with flue exhaust electrical fan (mod. S).
- Continuous modulation gas valve.
- Safety FLUE CONTROL preventing burnt gases from entering the
room (mod. SIL TOP).
- Combustion chamber provided with ceramic fibre insulation (mod. S).
- Instruments for unit control and regulation.
- Sanitary flow meter.
- IP X4D protection degree.

• Installation and Maintenance


- Easy installation of the water heater thanks to template connections.
- Maintenance is made simple thanks to easy accessibility to internal
components.

• Optional accessories
- For accessories suitable for SIL water heater, see page 85.
- Flue suction/exhaust kits are not included in the supply. See accessories
on demand on page 85.
- Polyphosphate doser type DPO/B. 220
A 94,5
• Certification
- SIL water heaters are EC type approved.
675

- In the presence of hard water it is


recommended to assemble a
polyphosphate proportional doser at the
water heater cold water inlet.

440 250

97

dimensions for
184,5

** SIL S Top

Connections: see template on page 79.

water heater furnace power hot sanitary water Sanitary circuit power A Cold water Hot water gas Weight
type supply (ΔT 25°C) l/min. max. pressure voltage inlet outlet inlet
kW kcal/h min max bar V/Hz mm. Ø Ø Ø kg
SIL 14 TOP 27 23.220 2,5 13,6 10 230/50 132,5 1/2” 1/2” 1/2” 25
SIL 14 S TOP 27 23.220 2,5 13,6 10 230/50 * 1/2” 1/2” 1/2” 26
* Flue connections: concentric or split discharge

water heater fuel water heater Useful power


code type kW kcal/h
00045100 natural gas SIL 14 TOP 8÷ 23,7 6.880÷ 20.468
00045110 LPG SIL 14 TOP 8÷ 23,7 6.880÷ 20.468
00045120 natural gas SIL 14 S TOP 8÷ 23,7 6.880÷ 20.468
00045130 LPG SIL 14 S TOP 8÷ 23,7 6.880÷ 20.468

62
Gas storage water heaters

•SAL 80S - SAL 120S


- High-efficiency wall-hung forced draught proof water heater.
- 75 Lt. (SAL 80 S) and 115 Lt. (SAL 120 S) storage boiler, full glass
glazed and coated with foamed polyurethane insulation.
- Flue exhaust adjustable cap.
- Burnt flue exhaust fan.
- Electronic ignition with ionization flame control.
- Boiler inspection and cleaning flange.
- Natural gas or LPG operation.
- Instruments for unit control and regulation.

• Maintenance
- Maintenance is made simple thanks to easy accessibility to internal
components.

• Optional accessories
- For accessories suitable for SAL S water heater, see page 85.
- Flue suction/exhaust kits are not included in the supply. See
accessories on demand on page 85.

• Certification
- SAL S water heaters are EC type approved.

Ø60
Ø38
190

30
210

B
C
a2
a3 a1

325 75
170

250
60
460

80 185 80

450 Vistatop
Superiore
view

water heater furnace power hot sanitary water Sanitary circuit max. power A B C Gas Hot water Cold water Weight
type supply A.C.S. ΔT 40°C pressure voltage Inlet outlet inlet
kW kcal/h l/h bar V/Hz mm. mm. mm. Ø a1 Ø a2 Ø a3 kg
SAL 80 S 5 4.300 92 6 230/50 1.040 895 850 3/8” 1/2” 1/2” 49
SAL 120 S 5 4.300 92 6 230/50 1.400 1.255 1.210 3/8” 1/2” 1/2” 74

water heater water heater Useful power


code type kW kcal/h
00045500 SAL 80 S 4,7 4.042
00045510 SAL 120 S 4,7 4.042

63
Gas storage water heaters

•SAL 150S - SAL 180S


- High-efficiency forced draught proof water heater.
- 145 Lt. (SAL 150 S) and 175 Lt. (SAL 180 S) storage boiler, full glass
glazed and coated with foamed polyurethane insulation.
- Flue exhaust adjustable cap.
- Burnt flue exhaust fan.
- Electronic ignition with ionization flame control.
- Boiler inspection and cleaning flange.
- Natural gas or LPG operation.
- Instruments for unit control and regulation.

• Maintenance
- Maintenance is made simple thanks to easy accessibility to internal
components.

• Optional accessories
- For accessories suitable for SAL S water heater, see page 85.
- Flue suction/exhaust kits are not included in the supply. See
accessories on demand on page 85.

• Certification
- SAL S water heaters are EC type approved.

Ø100
Ø60
220
a2

a4

F
a1

G
A

a3
B
C
D

50
251
101 139
139
251

101
520

251

Ø80
139

520 101
Vista
topSuperiore
view

water heater furnace hot sanitary water Sanitary circuit max. power A B C D F G gas Hot water Cold water Hot water Weight
type power supply ΔT 40°C pressure voltage inlet outlet inlet tank ricirculation
kW kcal/h l/h bar V/Hz mm. mm. mm. mm. mm. mm. Ø a1 Ø a2 Ø a3 Ø a4 kg
SAL 150 S 18 15.481 328 6 230/50 1.615 715 420 385 1.925 1.750 1/2” 3/4” 3/4” 3/4” 100
SAL 180 S 19 16.341 349 6 230/50 1.815 715 420 385 2.125 1.950 1/2” 3/4” 3/4” 3/4” 110

water heater water heater Useful power


code type kW kcal/h
00045520 SAL 150 S 16,7 14.363
00045530 SAL 180 S 17,5 15.051

64
Gas storage water heaters

•SAL 220S ÷ SAL 400S


- High-efficiency forced draught proof water heater.
- 220 Lt. (SAL 220 S), 300 Lt. (SAL 300 S) and 400 Lt. (SAL 400 S)
storage boiler, full glass glazed.
- Boiler coated with 50 mm. thick closed cell foamed polyurethane.
- Flue exhaust adjustable cap.
- Burnt flue exhaust fan.
- Electronic ignition with ionization flame control.
- Boiler inspection and cleaning flange.
- Natural gas or LPG operation.
- Instruments for unit control and regulation.

• Maintenance
- Maintenance is made simple thanks to easy accessibility to internal
components.

• Optional accessories
- For accessories suitable for SAL S water heater, see page 85.
- Flue suction/exhaust kits are not included in the supply. See
accessories on demand on page 85.

• Certification
- SAL S water heaters are EC type approved.

Ø100
Ø60
295
a2

a4
a3

B
a1
C
E
a5
D
565
480

110
420
239

481
95
720

95 239 95

720 Vistatop
Superiore
view

water heater furnace hot sanitary water Sanitary circuit power A B C D E gas Hot water Cold water Hot water Scarico Weight
type power supply ΔT 40°C max. pressure voltage inlet outlet inlet tank ricirculation
kW kcal/h l/h bar V/Hz mm. mm. mm. mm. mm. Ø a1 Ø a2 Ø a3 Ø a4 Ø a5 kg
SAL 220 S 28,5 24.512 527 6 230/50 1.660 1.495 1.365 970 1.300 1/2” 1 1/4” 1 1/4” 1” 1” 202
SAL 300 S 31 26.662 573 6 230/50 2.015 1.840 1.720 970 1.655 1/2” 1 1/4” 1 1/4” 1” 1” 245
SAL 400 S 31 26.662 573 6 230/50 2.365 2.190 2.070 1.135 2.000 1/2” 1 1/4” 1 1/4” 1” 1” 286

water heater water heater Useful power


code type kW kcal/h
00045540 SAL 220 S 25,8 22.190
00045550 SAL 300 S 28 24.082
00045560 SAL 400 S 28 24.082

65
Gas storage water heaters

•SAL 220 ÷ SAL 400


- High-efficiency forced draught open chamber water heater.
- 220 Lt. (SAL 220 S), 300 Lt. (SAL 300 S) and 400 Lt. (SAL 400 S)
storage boiler, full glass glazed and coated with foamed polyurethane.
- Flue safety thermostat.
- Piezoelectric ignition.
- Boiler inspection and cleaning flange.
- Natural gas or LPG operation.
- Instruments for unit control and regulation.

• Maintenance
- Maintenance is made simple thanks to easy accessibility to internal
components.

• Certification
- SAL water heaters are EC type approved.

Ø180

200
a2

a4
a3
a1 A

B
E

a5
D
605
545

110
460

Ø180

720

720

Vista
topSuperiore
view

water heater furnace hot sanitary waterSanitary circuit power A B D E gas Hot water Cold water Hot water Scarico Weight
type power supply ΔT 40°C max. pressure voltage inlet outlet inlet tank ricirculation
kW kcal/h l/h bar V/Hz mm. mm. mm. mm. Ø a1 Ø a2 Ø a3 Ø a4 Ø a5 kg
SAL 220 34 29.242 621 6 230/50 1.600 1.400 1.010 1.330 1/2” 1 1/4” 1 1/4” 1” 1” 160
SAL 300 34 29.242 621 6 230/50 1.960 1.750 1.010 1.680 1/2” 1 1/4” 1 1/4” 1” 1” 202
SAL 400 34 29.242 621 6 230/50 2.310 2.100 1.175 2.030 1/2” 1 1/4” 1 1/4” 1” 1” 243

water heater water heater Useful power


code type kW kcal/h
00045570 SAL 220 30,3 26.060
00045580 SAL 300 30,3 26.060
00045590 SAL 400 30,3 26.060

66
Zone management devices

•BOX ZONE
- Zone management devices for systems up to 35 kW.
- Ideal for embedded-type assembly; wall-hung installation is also possible.
- Zone delivery circulators.
- Operation management electronic card.
- Safety thermostat in low temperature zone (Box Mix Zone).
- Circulator anti-blocking function.
- Post-circulation (10 seconds).
- Temperature regulation for precedence probe (25÷ 45°C).
- Anti-freeze device (5÷ 7°C).
- Possible connection of an external probe to the Box Mix Zone (on demand).
- Electromechanical mixing valve (Box Mix Zone).
- Delivery temperature regulation of low temperature zone (Box Mix Zone).
- Water circuit breaker.
- Led Check Control for defect detection.

• Maintenance
- Maintenance is made simple thanks to easy accessibility to internal
components.

• Optional accessories
- To see the accessories suitable for BOX ZONE, see page 85.

• Range of accessories
- Box Mix Zone: for managing 1 high temperature zone and 1 low
temperature zone.
- Box Zone A2: for managing 2 high temperature or low temperature
zones (only for suitable boilers).
- Box Zone A3: for managing 3 high temperature or low temperature
zones (only for suitable boilers).

200 120 200 120 200 120

RC MC RC MC RC MC

RA3 MA 3
RB MB RA2 MA 2 RA2 MA 2
RA MA RA1 MA 1 RA1 MA 1

58 222 76 48 58 146 152 48 58 58 88 76 76 48 60

Box Zona Mix Box Zona A2 Box Zona A3 Side view

MC = Boiler delivery. RB = Low temperature heating return.


RC = Boiler return. MA1 - MA2 - MA3 = Temperature heating delivery systems.
MB = Low temperature heating delivery. RA1 - RA2 - RA3 = Temperature heating return systems.

Box zone Water Max. operating Max. operating Post power power Transformer Width Height Depth Weight
type content pressure temperature circulation voltage input protection fuse
l bar °C sec. V/Hz W A mm. mm. mm. kg
BOX ZONE MIX 5 3 90 10 230/50 260 3,15 440 550 175 17
BOX ZONE A2 5 3 90 10 230/50 230 3,15 440 550 175 18,5
BOX ZONE A3 5 3 90 10 230/50 340 3,15 440 550 175 20,5

Box Zone Box Zone


code type
08516500 BOX ZONE MIX
08516510 BOX ZONE A2
08516520 BOX ZONE A3

67
68
Boilers, Regulation systems and Radiators

Boilers for hot sanitary water supply


PAC B – PAC S
PAV/N
BITHERM
Regulation systems
CLASS PIÙ chronothermostat
In compliance with:
DIRECTIVE E.M.C. 89/336/EEC (Act No. D.L. 476 of 4/12/92) Boilers and Radiators not included)
DIRECTIVE L.V. 72/23/EEC (Act No. 791 of 18/10/77) (Radiators not included)

PAC B
PAC S
PAV/N
BITHERM
80 120 145 150 250 600
Litri

69
Boilers for hot sanitary water supply

•PAC B - PAC S
- Enamelled steel boilers.
- Foamed polyurethane insulation.
- High-prevalence circulator.
- Thermostat.
- Thermometer.
- Magnesium anode.
- Safety valve.
- Check valve.
- Air bleed automatic valve.
- Inspection flange.

• Installation and Maintenance


- Maintenance is made simple thanks to easy accessibility to internal
components.xxx

• Certification
- PAC B and PAC S boilers are EC type approved.

• Range of products
- PAC B, white covering (RAL 9003). Possible combination with ERA F,
XILO T 24 and ERA F S boilers.
- PAC S, dark grey covering (RAL 9007). Possible combination with SEC
and EXA.

a4 a1
a3 a2 a5
CALORECLIMA

80
1 3

0 4
850

A 600

Boiler exchange accumulator pipe coil Hot sanitarypeak samplingMaximum coil A Cold Hot coil coil Ricircolo Weight
type power capacity capacity water supply during storage maxmimum water water inlet outlet
ΔT 30°C the first 10’ pressure pressure inlet outlet
kW kcal/h l l l/h l bar bar mm. Ø a1 Ø a2 Ø a3 Ø a4 Ø a5 Kg
PAC 80 B 28,5 24.500 80 3,5 816 185 6 12 450 1/2” 1/2” 3/4” 3/4” 1/2” 73
PAC 120 B 34,9 30.000 120 4,25 1.000 260 6 12 600 1/2” 1/2” 3/4” 3/4” 1/2” 105

PAC 80 S 28,5 24.500 80 3,5 816 185 6 12 450 1/2” 1/2” 3/4” 3/4” 1/2” 73
PAC 120 S 34,9 30.000 120 4,25 1.000 260 6 12 600 1/2” 1/2” 3/4” 3/4” 1/2” 105

boiler boiler accumulator capacity


code type l
00047620 PAC 80 B 80
00047630 PAC 120 B 120

00047600 PAC 80 S 80
00047610 PAC 120 S 120

70
Boilers for hot sanitary water supply

•PAV/N
- two-layer glazed and enamelled steel boilers.
- scratch-resistant polyethylene coating.
- Foamed polyurethane insulation.
- Magnesium anode.
- Boiler safety control eletrical panel.
- Possible combination with GASTER N, BIG F, MEGA PREX (BT-SL) and
DUO PREX.

• Installation and Maintenance


- Maintenance is made simple thanks to easy accessibility to internal
components.xxx

• Certification
- PAV/N boilers are EC type approved.

a5

a3
B

a4

a1

Boiler exchange accumulator pipe coil hot sanitary peak sampling Maximum coil A B Cold Hot coil coil Hot water Weight
type power capacity capacity water supply during the storage maxmimum water water inlet outlet tank
ΔT 30°C first 10’ pressure pressure inlet outlet ricirculation
kW kcal/h l l l/h l bar bar mm. mm. Ø a1 Ø a2 Ø a3 Ø a4 Ø a5 Kg
PAV 150 N 30,6 26.350 145 5 1.032 145 6 10 600 890 1” 1 1/4” 1” 1” 1/2” 56
PAV 200 N 42 36.125 193 7,2 1.417 230 6 10 600 1.150 1” 1 1/4” 1” 1” 1/2” 72
PAV 300 N 58,3 50.150 296 9,6 1.965 340 6 10 600 1.660 1” 1 1/4” 1” 1” 1/2” 96
PAV 500 N 73,5 63.220 494 12,1 2.782 690 6 10 750 1.640 1” 1 1/4” 1” 1” 1/2” 125
PAV 600 N 89,7 77.150 591 14,4 2.963 795 6 10 750 1.950 1” 1 1/4” 1” 1” 1/2” 152

boiler boiler accumulator capacity


code type l
00047550 PAV 150 N 145
00047560 PAV 200 N 193
00047570 PAV 300 N 296
00047580 PAV 500 N 494
00047590 PAV 600 N 591

71
Boilers for hot sanitary water supply

•BITHERM
- enamelled steel boilers.
- Foamed polyurethane insulation.
- Magnesium anode.
- Fitted with registering (mininimum and maximum) thermostat and
thermometer
- Possible combination with SEC, EXA, NEINOX, NEINOX BT.

• Installation and Maintenance


- Maintenance is made simple thanks to easy accessibility to internal
components.

• Optional accessories
- Kits for water connections to Neinox and Neinox BT boiler are not
included in the supply.

• Certification
- BITHERM boilers are EC type approved.

• Kits for water connections


C A
to NEINOX and
NEINOX BT boilers. BITHERM CALORECLIMA

a2
a4 a3
code description a5
B

a1
08510830 Kits for water connections

Boiler exchange accumulator Pipe coil hot sanitary peak sampling Max. coil A B C Cold Hot coil coil Hot Weight
type power capacity capacity water supply during the storage max water water inlet outlet water tank
ΔT 30°C first 10’ pressure pressure inlet outlet ricirculation
kW kcal/h l l l/h l bar bar mm. mm. mm. Ø a1 Ø a2 Ø a3 Ø a4 Ø a5 Kg
BITHERM 150 29,3 25.200 150 7 840 225 6 6 1.000 610 610 3/4” 3/4” 1” 1” 3/4” 100
BITHERM 200 36 31.000 200 10 1.033 300 6 6 1.125 660 660 3/4” 3/4” 1” 1” 3/4” 130
BITHERM 250 42,7 36.800 250 13 1.226 375 6 6 1.375 660 660 3/4” 3/4” 1” 1” 3/4” 160

boiler boiler accumulator capacity


code type l
00047411 BITHERM 150 150
00047421 BITHERM 200 200
00047431 BITHERM 250 250

72
Regulation systems

•CLASS PIÙ
- Digital chronothermostat.
- Three-time-bracket weekly programme, set up for each day of the
week
- Half-week programme and one/two/three-time-bracket daily
programme
- Optimum start-up control.
- Self-adapting system, allowing automatic adaptation to the system
control.
- Summer/winter switching programme.
- Possible temperature adjustment for anti-freeze protection.
- Possible new calibration of the room probe (unless previously
calibrated).
- Fitted with anti-scuff periodic circulator control.

• Installation and Maintenance


- Easy adjustment and installation thanks to ready electrical controls on
the boiler.
- No maintenance required.

• Certification
- CLASS PIÙ chronothermostats are EC type approved. 135

104

41

chronothermostat chronothermostat Network voltage Network frequency Weight


code type V Hz kg
00087520 CLASS PIÚ 230± 15% 50 o 60 0,5

73
Aluminium radiators

•Aluminium radiators
- High radiant power radiators, made by high-pressure die-casting
special aluminium alloy.
- Thermal emission is optimized thanks to bigger convective fins with
respect to wet surfaces.
- Maximum operation pressure: 10 bar
- Battery inspection through hydropneumatic system.
- The radiators are suitable both for standard and single-pipe systems.
- Fitted with 1” Ø connections allowing direct assembly of the valves in
single-pipe systems.
- Paint covering is protected by a thermo retractile polyethylene film.

• Installation and Maintenance


- Minimum distances from the wall and from the floor are approximately
30 mm. and 120 mm. respectively.
- In the event of under recess installation, a space of 100 mm. upwards
shall be kept.
- Make sure that the filling water hardness is lower than 15°F with a Ph
ranging from 7 to 8.
- Do not use solvents or abrasive materials when cleaning the radiator,
thus avoiding to damage the paint covering.
- Do not use fired tile nor porous material humidifiers.

• Optional accessories
- For optional accessories intended for aluminium radiators, see page?

80 98 800

- In the presence of hard water it is


recommended to assemble a
polyphosphate proportional dosing unit A B
at the boiler cold water inlet.

radiator radiator A B Larghezza


Singolo 10 elements
code type
F17165100 510 500 581,5
F17166100 610 500 581,5
F17167100 710 500 581,5
F17168100 810 500 581,5

• Technical data

Types 510 610 710 810


Heating power ΔT 50°C in compliance with EN 442 W 1.220 1.410 1.590 1.730
kcal/h 1.049,2 1.212,6 1.367,4 1.487,8
Heating power ΔT 60°C in compliance with EN 442 W 1.545 1.788 2.026 2.201
Heating power ΔT 70°C in compliance with EN 442 W 1.887 2.187 2.488 2.698
Heating power per part ΔT 50°C in compliance with EN 442 W 122 141 159 173
kcal/h 104,92 121,26 136,74 148,78
K coefficient n 1,2962 1,3039 1,3282 1,3204
Maximum operation pressure bar 10 10 10 10
Water composition l 4 4,3 5 5,2
Elements n 10 10 10 10
Connections Ø 1” 1” 1” 1”
Weight kg 13 15 18 20

74
Water treatment line

Water softeners
SWEET-M
EAU-M
EAU-E BIOS
DOUBLE-E
PLUS-E
In compliance with:
DIRECTIVE E.M.C. 89/336/EEC (Act No. D.L. 476 of 4/12/92)
DIRECTIVE L.V. 72/23/EEC (Act No. 791 of 18/10/77)

Water filters
FCO
FCP
FCA
FT
FF
FD
In compliance with:
DIRECTIVE E.M.C. 89/336/EEC (Act No. D.L. 476 of 4/12/92) (only FT-FF-FD fitlers)
DIRECTIVE L.V. 72/23/EEC (Act No. 791 of 18/10/77) (only FT-FF-FD fitlers)

Dosing pumps
PDC
PDPH
In compliance with:
DIRECTIVE E.M.C. 89/336/EEC (Act No. D.L. 476 of 4/12/92)
DIRECTIVE L.V. 72/23/EEC (Act No. 791 of 18/10/77)

Polyphosphate dosing units


DPO

SWEET-M
EAU-M
EAU-E BIOS
DOUBLE-E
PLUS-E
40 125 210 720 960 3.360
m3 °F

75
Water softeners

•SWEET-M
- Time regeneration water softeners for domestic heating.
- Time electromechanical operation and programme valve.
- Rigid, shock-resistant, parallelepiped, compact and stylish shell in non-
toxic polyethylene.
- Realized in compliance with the standards ruling the materials for
alimentary use.
- Fitted with 1 gearless traction electric motor.
- No water hammering during operation and regeneration.
- Reduced loss of pressure during operation.
- Possible chlorine producing unit assembly in compliance with D.M. No.
443 standard.
- SWEET-M water softeners are supplied preloaded and equipped with
hardness mixer and by-pass.
- Hardness test.

• Installation and Maintenance


- Easy installation thanks to high adaptability to house appliances. Simply
connect the softener to the water delivery system outlet and to a 230V
power supply outlet. An inlet filter shall be assembled in order to
prevent floating particles from entering.
- Maintenance is made simple thanks to the softener’s simple structure.

• Optional accessories
- For optional accessories intended for SWEET-M water softeners, see
page 113.

• Certification
- SWEET-M water softners are EC type approved.

A B

water softener average maximum maximum power Salt consumption salt A B C D weight**
type capacity capacity pressure voltage for regeneration container
l/h l/h bar V/Hz kg kg mm. mm. mm. Ø kg
SWEET 8 M 600 1.200 6 230/50 mon. 2,2 55 316 559 673 3/4” 23
SWEET 15 M 1.200 1.600 6 230/50 mon. 2,7 100 316 559 1.006 3/4” 29
SWEET 22 M 1.600 2.500 6 230/50 mon. 3,7 125 316 559 1.127 3/4” 35
* Non-continuous maximum capacity - ** Weight: with filling material
Cyclic capacity has been calculated with water overall hardness being 26° F (260 ppm CaCO3); turbidity free, colourless, iron and oil free, and supplied at continuous
average capacity.

water softener water softener Maximum cyclic capacity


code type m3 °F
00053511 SWEET 8 M 40
00053521 SWEET 15 M 75
00053531 SWEET 22 M 125

76
Water softeners

•EAU-M
- Time regeneration water softeners for domestic heating.
- Time electromechanical operation and programme valve.
- Rigid, shock-resistant, parallelepiped, compact and stylish shell in non-
toxic polyethylene.
- Realized in compliance with the standards ruling the materials for
alimentary use.
- Fitted with two gearless traction electric motors.
- No water hammering during operation and regeneration.
- Reduced loss of pressure during operation.
- Possible chlorite producing unit assembly in compliance with D.M. No.
443 standard.
- Hardness test.
- EAU-M water softeners are supplied preloaded.

• Installation and Maintenance


- Easy installation thanks to high adaptability to house appliances. Simply
connect the softener to the water delivery system outlet and to a 230V
power supply outlet. An inlet filter shall be assembled in order to
prevent floating particles from entering.
- Maintenance is made simple thanks to the softener’s simple structure.

• Optional accessories
- For optional accessories intended for EAU-M water softeners, see
page 113.

• Certification
- EAU-M water softners are EC type approved.

A B

water softener average maximum maximum power Salt consumption salt A B C D Peso**
type capacity capacity* pressure voltage for regeneration container
l/h l/h bar V/Hz kg kg mm. mm. mm. Ø kg
EAU 8 M 600 1.200 6 230/50 mon. 2,2 55 330 540 740 3/4” 23
EAU 15 M 1.200 1.600 6 230/50 mon. 2,7 100 330 540 1.040 3/4” 29
EAU 22 M 1.600 2.500 6 230/50 mon. 3,7 125 330 540 1.160 3/4” 35
* Non-continuous maximum capacity - ** Weight: with filling material
Cyclic capacity has been calculated with water overall hardness being 26° F (260 ppm CaCO3); turbidity free, colourless, iron and oil free, and supplied at continuous
average capacity.

water softener water softener Maximum cyclic capacity


code type m3 °F
00053241 EAU 8 M 40
00053251 EAU 15 M 75
00053261 EAU 22 M 125

77
Water softeners

•EAU-E Bios
- Time, volume* and volume/time combined regeneration water
softeners for domestic heating.
- Microprocessor electronic servocontrol operation and programme
valve.
- Equipped with “BIO COMPURITY SYSTEM” protection against build
up of bacteria.
- Rigid, shock-resistant, parallelepiped, compact and stylish shell in non-
toxic polyethylene.
- Realized in compliance with the standards ruling the materials for
alimentary use.
- Countercurrent regeneration for efficient resin feeding and reduced
water and salt consumption.
- Data storage guaranteed by a self-recharging accumulator for at least
three months of black out.
- The supply includes flexible pipes and a by-pass fitted with hardness
proportional mixer, backflow valves and built-in chlorine producing unit.
- In compliance with D.M. No. 443 standard.
- Hardness test.

• Installation and Maintenance


- Easy installation thanks to high adaptability to house appliances. Simply
connect the softener to the water delivery system outlet and to a 230V
power supply outlet. An inlet filter shall be assembled in order to
prevent clinker from entering.
- Maintenance is made simple thanks to the softener’s simple structure.

• Optional accessories
- For optional accessories intended for EAU-E Bios water softeners, see
page 113.
- For volumetric* regeneration a pulse shaper kit shall be installed. See D
optional accessories on page 113.

• Certificazione
– EAU-E Bios water softners are EC type approved.
C

A B

water softener average maximum maximum power Salt consumption salt A B C D weight**
type capacity capacity* pressure voltage for regeneration container
l/h l/h bar V/Hz kg kg mm. mm. mm. Ø kg
EAU 8 E BIOS 600 1.200 6 230/50 mon. 2,2 55 330 540 740 3/4” 20
EAU 15 E BIOS 1.200 1.600 6 230/50 mon. 2,7 100 330 540 1.040 3/4” 30
EAU 22 E BIOS 1.600 2.500 6 230/50 mon. 3,7 125 330 540 1.160 3/4” 40
* Non-continuous maximum capacity - ** Weight: with filling material
Cyclic capacity has been calculated with water overall hardness being 26° F (260 ppm CaCO3); turbidity free, colourless, iron and oil free, and supplied at continuous
average capacity.

water softener water softener Maximum cyclic capacity


code type m3 °F
00053302 EAU 8 E BIOS 40
00053312 EAU 15 E BIOS 75
00053322 EAU 22 E BIOS 125

78
Water softeners

•DOUBLE-E
- Time, volume* and volume/time combined regeneration water
softeners for domestic/residential heating.
- Microprocessor electronic servocontrol operation and programme
valve.
- Cylinder in polyethylene strengthened with plastic reinforced by fiber
glass.
- Three-way proportional by-pass with non-return valve for models
Double 35E – Double 50E - Double 65E.
- Hardness mixer for models Double 35E – Double 50E - Double 65E.
- Connecting flexible pipes.
- Salt container in polyethylene.
- Possible chlorine producing unit assembly in compliance with D.M. No.
443 standard.
- Hardness test.
- Models DOUBLE 35E and 50E are supplied preloaded.

• Installation and Maintenance


- Easy installation thanks to high adaptability to house appliances. Simply
connect the softener to the water delivery system outlet and to a 230V
power supply outlet. An inlet filter shall be assembled in order to
prevent clinker from entering.
- Maintenance is made simple thanks to the softener’s simple structure.

• Optional accessories
- For optional accessories intended for DOUBLE-E water softeners, see B A
page 113. G
- For volumetric* regeneration a pulse shaper kit shall be installed. See
optional accessories on page 113.

useful space
utile)
• Certification E
D

(spazio
– DOUBLE-E water softners are EC type approved. C

• Range of products
- DOUBLE 35E-50E-65E: for domestic heating. F
- DOUBLE 85E-125E: for residential heating.

water softener average maximum maximum power Salt consumption salt A B C D E F G weight**
type capacity capacity* pressure voltage for regeneration container
l/h l/h bar V/Hz kg kg mm. mm. mm. mm. mm. mm. Ø kg
DOUBLE 35 E 1.800 2.700 6 230/50 mon. 7 200 800 260 1.335 1.435 530 1.050 1 1/4” 60
DOUBLE 50 E 2.400 3.000 6 230/50 mon. 9,5 200 900 330 1.600 1.700 530 1.050 1 1/4” 85
DOUBLE 65 E 3.500 5.500 6 230/50 mon. 16 300 1.100 370 1.600 1.700 700 1.060 1 1/4” 101

DOUBLE 85 E 5.700 8.100 6 230/50 mon. 21 300 1.150 400 1.900 2.000 700 1.060 1 1/2” 164
DOUBLE 125 E 7.500 10.000 6 230/50 mon. 31 300 1.150 400 1.900 2.000 700 1.060 1 1/2” 176
* Non-continuous maximum capacity - ** Weight: with filling material
Cyclic capacity has been calculated with water overall hardness being 26° F (260 ppm CaCO3); turbidity free, colourless, iron and oil free, and supplied at continuous
average capacity.

water softener water softener Maximum cyclic capacity


code type m3 °F
00053361 DOUBLE 35 E 210
00053371 DOUBLE 50 E 275
00052932 DOUBLE 65 E 412

00052942 DOUBLE 85 E 510


00052952 DOUBLE 125 E 720

79
Water softeners

•PLUS-E
- Time, volume* and volume/time combined regeneration water
softeners for industrial heating.
- Electronic servocontrol operation and programme valve.
- Cylinder in polyethylene strengthened with plastic reinforced by fiber
glass for models PLUS 165E and PLUS 215E.
- Hot-galvanized steel cylinder for models PLUS 265E and PLUS 550E.
- Connecting flexible pipes.
- Salt container in polyethylene.
- Hardness test.

• Installation and Maintenance


- Easy installation thanks to high adaptability to house appliances. Simply
connect the softener to the water delivery system outlet and to a 230V
power supply outlet. An inlet filter shall be assembled in order to
prevent clinker from entering.
- Maintenance is made simple thanks to the softener’s simple structure.

• Optional accessories
- For optional accessories intended for PLUS-E water softeners, see
page 113.
- For volumetric* regeneration a pulse shaper kit shall be installed. See
optional accessories on page 113.

• Certification
B A
– PLUS-E water softners are EC type approved.
G

– On demand: to be informed on the delivery time, please contact our

utile)
(spaziospace
Sales Department.
E
D

useful
C

water softener average maximum maximum power Salt consumption salt A B C D E F G weight**
type capacity capacity* pressure voltage for regeneration container
l/h l/h bar V/Hz kg kg mm. mm. mm. mm. mm. mm. Ø kg
PLUS 165 E 9.000 15.000 6 230/50 mon. 40 800 1.600 470 2.030 2.330 1.000 1.200 2” 246
PLUS 215 E 10.000 16.800 6 230/50 mon. 53 800 1.600 470 2.030 2.330 1.000 1.200 2” 288
PLUS 265 E 12.600 18.000 6 230/50 mon. 65 1.000 1.670 600 2.330 2.630 1.160 1.350 2” 387
PLUS 330 E 18.000 25.000 6 230/50 mon. 82 1.000 2.060 750 2.415 2.720 1.160 1.350 2” 683
PLUS 425 E 18.600 25.500 6 230/50 mon. 106 1.000 2.060 750 2.415 2.720 1.160 1.350 2” 718
PLUS 550 E 24.000 32.000 6 230/50 mon. 137 1.500 2.315 900 2.450 2.750 1.265 1.350 2” 932
* Non-continuous maximum capacity - ** Weight: with filling material
Cyclic capacity has been calculated with water overall hardness being 26° F (260 ppm CaCO3); turbidity free, colourless, iron and oil free, and supplied at continuous
average capacity.

water softener water softener Maximum cyclic capacity


code type m3 °F
00053171 PLUS 165 E 960
00053181 PLUS 215 E 1.260
00053191 PLUS 265 E 1.560
00053201 PLUS 330 E 1.980
00053211 PLUS 425 E 2.550
00053221 PLUS 550 E 3.360

80
Water filter

•“cartridge” FCO
- Chromium-plated and polished brass header.
- Shatterproof and non-ageing trogamid T transparent glass.
- Long-lasting washable cartridge.
- Chromium-plated bronze connection header for models FCO _” and
FCO 1”.
- Washable plaited stainless steel cartridge with high-filtering wide surface
for models FCO 1 1/2” and FCO 2”.
• Installation and Maintenance
- Easy installation thanks to high adaptability to house appliances. Simply
connect the filter to the water delivery system outlet.
- Maintenance is made simple thanks to the filter’s simple structure.
• Certification
- FCO filters are EC type approved.
filter filter maximum recommended maximum max. operation filtering connections weight
code type capacity capacity temperature pressure degree
l/min. l/min °C bar micron Ø kg
00052770 FCO 3/4” 70 45 30 7 60 3/4” 3
00052780 FCO 1” 100 55 30 7 60 1” 3
00052790 FCO 1 1/2” 150 100 30 7 50 1 1/2” 4
00052800 FCO 2” 250 170 30 7 50 2” 3,5

•“cleaning” FCP
- Brass header.
- Shatterproof and non-ageing trogamid T transparent glass.
- AISI 316 stainless steel cartridge.
- Internal parts in plastic material for alimentary use.
- Maintenance spanner.
• Installation and Maintenance
- Easy installation thanks to high adaptability to house appliances. Simply
connect the filter to the water delivery system outlet.
- Maintenance is made simple thanks to the filter’s simple structure.
• Certification
- FCP filters are EC type approved.

filter filter maximum recommended maximum max. operation filtering connections weight
code type capacity capacity temperature pressure degree
l/min. l/min °C bar micron Ø kg
00053440 FCP 3/4” 50 40 30 10 90 3/4” 2
00053450 FCP 1” 75 60 30 10 90 1” 2
00053460 FCP 1 1/4” 80 70 30 10 90 1 1/4” 2

•“self-cleaning” FCA
- All plastic parts are made of acetal resin.
- All metal parts are made of brass.
- Shatterproof and non-ageing trogamid T transparent glass.
- AISI 316 stainless steel cartridge.
- NBR gasket.
- Maintenance spanner.
- Adjustable inlet-outlet flange.
- Backwashing turbojet.
• Installation and Maintenance
– Easy installation thanks to high adaptability to house appliances. Simply
connect the filter to the water delivery system outlet.
- Maintenance is made simple thanks to the filter’s simple structure.
• Certification
- FCA filters are EC type approved.

filter filter maximum recommended maximum max. operation filtering connections weight
code type capacity capacity temperature pressure degree
l/min. l/min °C bar micron Ø kg
00053400 FCA 3/4” 50 40 30 10 90 3/4” 3
00053410 FCA 1” 75 60 30 10 90 1” 3
00053420 FCA 1 1/4” 80 70 30 10 90 1 1/4” 3

81
Water filter

•FT - FF - FD
- Mineral container in plastic reinforced by fiber glass
- Automatic valve with microprocessor control.

• Installation and Maintenance


- Easy installation thanks to high adaptability to house appliances. Simply
connect the filter to the water delivery system outlet.
- Maintenance is made simple thanks to the filter’s simple structure.

• Certification
- FT – FF - FD filters are EC type approved.

• Range of products
- FT filter: turbidity
- FF filter: deferrizator
- FD fitler: cleaner

- On demand: to be informed on the delivery time, please contact our


Sales Department.

filter filter maximum recommended maximum washing power connections weight**


code type capacity* capacity operation capacity voltage
pressure 230V/50Hz
l/min. l/min. bar l/min. W Ø kg
00052582 FT 26 E 15 23 7 23 8 1” 90
00052592 FT 36 E 30 55 7 44 8 1” 143
00052632 FF 26 E 5 16 Δ 7 18 8 1” 57
00052642 FF 36 E 12 25 Δ 7 32 8 1” 101
00052682 FD 26 E 8 15 7 18 8 1” 52
00052692 FD 36 E 24 35 7 32 8 1” 67
EXT 12V transformer - *non continuous – Δ Fe max 1,5 ppm - **Weight: with filling materials

82
Dosing pumps

•PDC
- Gradual regulation automatic dosing pump.
- Antacid header.
- Injection capacity regulation by means of % graduated switch.
- Maximum injection of 2 Lt./h of chemical product for PDC 2 and of 5
Lt./h for PDC 5.
• Installation and Maintenance
- Easy installation thanks to high adaptability to house appliances.
- Maintenance is made simple thanks to the dosing pump’s simple
structure.
• Optional accessories
- For the chemical product container intended for dosing pumps, see
optional accessories on page 113.
• Certification
– - PDC dosing pumps are EC type approved.

pump pump maximum maximum maximum power weight


code type capacity operation temperature voltage
pressure 230V/50Hz
l/h bar °C W kg
00053760 PDC 2 2 10 50 30 5
00053770 PDC 5 5 10 50 50 5

•PDPH
- Meter proportional automatic dosing pump.
- Meter shell in OT 58 equipped with variable proportionality dosing
pump control reader, 3.5 p.p.m. maximum dosage of Aquasil 20/40 P2
O5 chemical product for models PDPH 1.5 and PDPH 2,7.
- Models PDPH 1.5 and PDPH 2.7 are used to avoid boiler scaling and
corrosion.
- Antacid header for models PDPH 5 and PDPH 30.
- Bronze meter with pulse shaper automatic header for variable
proportionality dosing pump control maximum injection of 10 Lt./h of
chemical product for models PDPH 5 and PDPH 30.
- Regulation of the product amount by means of maximum 1000 p.p.m.
graduated switch for models PDPH 5 and PDPH 30.

• Installation and Maintenance


- Easy installation thanks to high adaptability to house appliances.
- Maintenance is made simple thanks to the dosing pump’s simple
structure.

• Optional accessories
- For the chemical product container intended for dosing pumps, see
optional accessories on page 113.
- For PLC chemical product use, see page 113.

• Certification
- PDPH dosing pumps are EC type approved.

pump pump maximum maximum maximum power injected meter weight**


code type capacity operation temperature voltage solution
pressure 230V/50Hz max.
m3/h bar °C W p.p.m. Ø kg
00053480 PDPH 1,5-15 1,5 6 40 3,5 3,5 1/2” 1,2
00053490 PDPH 2,7-20 2,5 6 40 3,5 3,5 3/4” 1,5

00053780 PDPH 5-20 5 10 50 65 1000 3/4” 7


00053790 PDPH 7-25 7 10 50 65 1000 1” 7
00053810 PDPH 10-30 10 10 50 65 1000 1 1/4” 8
00053820 PDPH 20-40 20 10 50 65 1000 1 1/2” 15
00053830 PDPH 30-50 30 10 50 65 1000 2” 16

83
Polyphosphate dosing units

•DPO
- Chromium-plated bright brass header.
- Chromium-plated brass unions male-male (only for model DPO 1”).
- Shatterproof and non-ageing trogamid T transparent glass.

• Installation and Maintenance


- As the dosing units do not need any connection to the power supply,
the installation results to be extremely easy.

• Certification
- DPO dosing units are EC type approved.

• Range of products
- DPO/A dosing unit, corrosion inhibitor for water featuring a hardness
degree up to 15°F.
- DPO/B dosing unit, corrosion inhibitor and anti-scale fluid for water
featuring a hardness degree exceeding 15°F.

dosing unit dosing unit minimum loss of amount of water treated maximum maximum polyphosphate weight
code type maximum pressure with inhibiting charge pressure temperature charge
capacity max. tipo A tipo B
l/min. bar m3 max. m3 max. bar °C g kg
00052730 DPO 1/2" A 2-25 0,25 20 – 10 40 80 1,5
00052740 DPO 1" A 4-60 0,25 180 – 10 40 800 4,5
00052750 DPO 1/2" B 2-25 0,25 – 20 10 40 80 1,5
00052760 DPO 1" B 4-60 0,25 – 180 10 40 800 4,5

84
Accessories for wall-hung and floor-standing gas boilers – gas water heaters

• Flanged concentric connecting kit for FUTURIA N


Warning: flanged concentric connecting kit results to be necessary each time
a concentric kit with a 60/100 diameter is fitted to the boiler.

code description boiler

08516310 Flanged concentric kit FUTURIA N 15 - FUTURIA N 25 - FUTURIA N 35

• Flanged concentric connecting kit


Warning: concentric kits A and B shall be combined with the kits of accessories featuring the same
reference. Example: A+A and B+B = Si, while A+B = No
Technical description
- 90° concentric bend (Ø 60/100) equipped with inspection outlets. – White enamelled aluminium
concentric pipe (Ø60/100) L= 0.85 Mt. – Gasket strip – Stainless steel wind-resistant terminal – rubber
seal – Two Ø100 washers – M/F aluminium reduction Ø60.

code description boiler/water heater

08508990 Concentric kit - A XILO LN - ERA F S - ERA F BS - SIL S


08515060 Concentric kit - B XILO LN - ERA F S - ERA F BS - SIL S
08515170 Concentric kit without flue outlet - B XILO - XILO D - XILO T - VELA XN - ALMA

• Condensation concentric kit


Technical description
- 90° concentric bend equipped with inspection outlets
- White enamelled aluminium concentric pipe L= 0.85 Mt.
- Stainless steel wind-resistant terminal – rubber seals – Two washers
Warning: for models FUTURIA N 15 – FUTURIA N 25 – FUTURIA N35,
the flanged concentric connecting kit shall be fitted “code 08516310”

code description boiler

08510120 Condensation concentric kit Ø80/100 FUTURIA L - FUTURIA N 15 - FUTURIA N 25 - FUTURIA N 35


FUTURIA PLUS
08516080 Condensation concentric kit Ø80/125 FUTURIA N 50

• Split simple high kit Ø 80 1 1


Technical description
- Split tee-union equipped with inspection holes – Two white enamelled 90° Ø 80 bends
- Rubber seals – M/F Ø 60 aluminium reduction

• Split simple high kit Ø 60 2 2


Technical description
- Split tee-union equipped with inspection holes - Two white enamelled 90° Ø 80 bends
- 2 Ø 60/80 white enamelled reductions - Rubber seals - M/F Ø 60 aluminium reduction
code description boiler/water heater

08509860 Split simple high kit Ø 80 XILO LN - XILO - XILO D - XILO T - VELA XN - ALMA
ERA F S - ERA F BS - SIL S

85
Accessories for wall-hung and floor-standing gas boilers – gas water heaters

• Condensation split simple high kit Ø 80 3


Technical description
- Split tee-union equipped with inspection holes – Two white enamelled 90° Ø 80 bends 3
- Rubber seals

• Condensation split simple high kit Ø 60 4


Technical description
4
- Split tee-union equipped with inspection holes – Two white enamelled 90° Ø 80 bends
- 2 Ø 60/80 white enamelled reductions – Rubber seals

code description boiler

08510320 Split simple high kit Ø 80 FUTURIA L - FUTURIA N - FUTURIA PLUS


08511330 Split simple high kit Ø 60 FUTURIA L - FUTURIA N - FUTURIA PLUS

• Condensation split simple short kit Ø 80 7


Technical description
- M/F flat splitter equipped with inspection holes – Two white enamelled 90° Ø 80 bends 7
- Rubber seals

• Condensation split simple short kit Ø 60 8


Technical description
- M/F flat splitter equipped with inspection holes – Two white enamelled 90° Ø 80 bends 8
- 2 Ø 60/80 white enamelled reductions – Rubber seals

code description boiler

08509690 Split simple short kit Ø 80 FUTURIA L


08511320 Split simple short kit Ø 60 FUTURIA L

86
Accessories for wall-hung and floor-standing gas boilers – gas water heaters

• Concentric roof-top discharge kit 1 , with lead propeller nut 2 and berm discharge 3
Technical description
- one concentric pipe L=1.2 Mt. Ø 125 with flue terminal
- Aluminium reduction stub pipe Ø 60/80 1
- Plastic reduction stub pipe Ø 100/125
3
- Coaxial connection stub pipe Ø 60/80 with inspection outlets 2
- Aluminium reduction M/F Ø 60
For model FUTURIA N 50, a flanged concentric 120 mm stub pipe “kit” is
necessary Ø 80/125 with flue inspection outlets “code 08516120”.

code description boiler/water heater

08507590 Concentric roof-top discharge kit Ø 125 FUTURIA L - FUTURIA N 50 - FUTURIA PLUS - XILO LN - XILO
XILO D - XILO T - VELA XN - ALMA - ERA F S - ERA F BS - SIL S
08507600 lead propeller nut Kit FUTURIA L - FUTURIA N 50 - FUTURIA PLUS - XILO LN - XILO - XILO D
XILO T - VELA XN - ALMA - ERA F S - ERA F BS - SIL S
08508100 berm discharge connection Kit FUTURIA L - FUTURIA N 50 - FUTURIA PLUS - XILO LN - XILO - XILO D
XILO T - VELA XN - ALMA - ERA F S - ERA F BS - SIL S

• Concentric roof-top discharge kit 1 , with lead propeller nut 2 and berm discharge 3
Technical description
- one concentric pipe L=1.2 Mt. Ø 100 with flue terminal
- Coaxial connection stub pipe Ø 60/100 with inspection outlets 1
- Aluminium reduction M/F Ø 60
3
2
Warning: For models FUTURIA N 15 – FUTURIA N 25,
a flanged concentric connection “kit” is necessary “code 08516310”.

code description boiler

08514120 Concentric roof-top discharge kit Ø 100 FUTURIA L - FUTURIA N 15 - FUTURIA N 25 - FUTURIA N 35
08507600 lead propeller nut Kit FUTURIA L - FUTURIA N 15 - FUTURIA N 25 - FUTURIA N 35
08508100 berm discharge connection Kit FUTURIA L - FUTURIA N 15 - FUTURIA N 25 - FUTURIA N 35

• Split separate discharge kit


Technical description
- 2 flanged stub pipes Ø 80 with inspection outlet
- Rubber seals

code description boiler/water heater

08514110 Condensation split separate discharge kit FUTURIA L


08511090 Split separate discharge kit XILO LN - XILO - XILO D - XILO T - VELA XN - ALMA
ERA F S - ERA F BS - SIL S

87
Accessories for wall-hung and floor-standing gas boilers – gas water heaters

• Split separate discharge non-flanged kit


Technical description
- 2 stub pipes with inspection outlet
- Rubber seals
code description boiler

08516090 Split separate discharge non-flanged kit Ø 80 FUTURIA N


08516100 Split separate discharge non-flanged kit Ø 60 FUTURIA N

• Concentric accessories for flue suction and discharge


- Warning: series A and B cannot be combined
Example: A + A and B + B = Si, while A + B = No

code description boiler/water heater

08509000 Concentric extension 1 Mt. kit Ø 60/100 - A XILO LN - XILO - XILO D - XILO T - VELA XN - ALMA
ERA F S - ERA F BS - SIL S
08515070 Concentric extension 1 Mt. kit Ø 60/100 - B XILO LN - XILO - XILO D - XILO T - VELA XN - ALMA
ERA F S - ERA F BS - SIL S

code description boiler

08510130 Concentric extension 1 Mt. kit Ø 60/100 (condensation) - A FUTURIA L - FUTURIA N 15 - FUTURIA N 25 - FUTURIA N 35
FUTURIA PLUS
08516110 Concentric extension 1 Mt. kit Ø80/Ø125 FUTURIA N 50

code description boiler/water heater

08511220 concentric terminal kit Ø60/Ø100 XILO LN - XILO - XILO D - XILO T - VELA XN - ALMA
L = 0,85 mt concentrica - A LED - ERA F S - ERA F BS - SIL S
08515160 concentric terminal kit Ø60/Ø100 XILO LN - XILO - XILO D - XILO T - VELA XN - ALMA - LED
L = 0,83 mt concentrica - B ERA F S - ERA F BS - SIL S

code description boiler/water heater

08509030 concentric 90° bend kit Ø60/Ø100 - A XILO LN - XILO - XILO D - XILO T - VELA XN - ALMA
ERA F S - ERA F BS - SIL S
08515100 concentric 90° bend kit Ø60/Ø100 - B XILO LN - XILO - XILO D - XILO T - VELA XN - ALMA
ERA F S - ERA F BS - SIL S

88
Accessories for wall-hung and floor-standing gas boilers – gas water heaters

code description boiler

08510140 concentric 90° bend kit Ø60/Ø100 (condensation) - A FUTURIA L - FUTURIA N 15 - FUTURIA N 25 - FUTURIA N 35
FUTURIA PLUS
08516430 concentric 90° bend kit Ø80/Ø125 FUTURIA N 50

code description boiler/water heater

08509020 concentric 45° bend kit Ø60/Ø100 - A XILO LN - XILO - XILO D - XILO T - VELA XN - ALMA
ERA F S - ERA F BS - SIL S
08515090 concentric 45° bend kit Ø60/Ø100 - B XILO LN - XILO - XILO D - XILO T - VELA XN - ALMA
ERA F S - ERA F BS - SIL S

code description boiler

08510150 concentric 45° bend kit Ø60/Ø100 (condensation) - A FUTURIA L - FUTURIA N 15 - FUTURIA N 25 - FUTURIA N 35
FUTURIA PLUS

code description boiler/water heater

08509490 concentric flanged 90° bend kit Ø60/Ø100 XILO LN - ERA F S - ERA F BS - SIL S
with flue inspection outlets - A
08515150 concentric flanged 90° bend kit Ø60/Ø100 XILO LN - ERA F S - ERA F BS - SIL S
with flue inspection outlets - B
08515200 concentric flanged 90° bend kit Ø60/Ø100 - B XILO - XILO D - XILO T - VELA XN - ALMA

code description boiler/water heater

08509060 Concentric flanged 120 mm stub pipe kit XILO LN - ERA F S - ERA F BS - SIL S
with flue inspection outlets Ø60/Ø100 - A
08515130 Concentric flanged 120 mm stub pipe kit XILO LN - ERA F S - ERA F BS - SIL S
with flue inspection outlets Ø60/Ø100 - B
08515190 Concentric flanged 120 mm stub pipe kit Ø60/100 - B XILO - XILO D - XILO T - VELA XN - ALMA

code description boiler

08514180 Concentric flanged 120 mm stub pipe kit Ø60/Ø100 FUTURIA L - FUTURIA N 15 - FUTURIA N 25 - FUTURIA N 35
with flue inspection outlets (condensation) - A FUTURIA PLUS
08516120 Concentric flanged 120 mm stub pipe kit Ø80/Ø125 FUTURIA N 50
with flue inspection outlets (condensation)
Warning: For models FUTURIA N 15 – FUTURIA N 25 – FUTURIA N 35, a flanged concentric connection “kit” is necessary “code 08516310”.
89
Accessories for wall-hung and floor-standing gas boilers – gas water heaters

code description boiler/water heater

08509010 Vertical concentric 1 Mt. Extension kit Ø60/Ø100 XILO LN - ERA F S - ERA F BS - SIL S
with flue inspection outlets* - A
08515080 Vertical concentric 1 Mt. Extension kit Ø60/Ø100 XILO LN - ERA F S - ERA F BS - SIL S
with flue inspection outlets - B
08515180 Vertical concentric 1 Mt. Extension kit Ø60/Ø100 - B XILO - XILO D - XILO T - VELA XN - ALMA

code description boiler/water heater

08509050 concentric bend strip kit Ø60/Ø100* - A XILO LN - XILO - XILO D - XILO T - VELA XN - ALMA
TREND - TREND L - ERA F S - ERA F BS - SIL S
08515120 concentric bend strip kit Ø60/Ø100 - B XILO LN - XILO - XILO D - XILO T - VELA XN - ALMA
ERA F S - ERA F BS - SIL S

code description boiler/water heater

08509040 concentric extension strip kit Ø60/Ø100* - A XILO LN - XILO - XILO D - XILO T - VELA XN - ALMA
ERA F S - ERA F BS - SIL S
08515110 concentric extension strip kit Ø60/Ø100 - B XILO LN - XILO - XILO D - XILO T - VELA XN - ALMA
ERA F S - ERA F BS - SIL S

• Split accessories for flue suction and discharge Ø80

code description boiler/water heater

08506940 Split Ø80 0.5 Mt. extension kit XILO-IN - XILO LN - XILO - XILO D - XILO T - VELA XN
ALMA - ERA F S - ERA F BS - SIL S

code description boiler/water heater

08510050 Split Ø80 0.5 Mt. extension kit (condensation) FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler/water heater

08506210 Split Ø80 1 Mt. extension kit INOVA L - XILO-IN - XILO LN - XILO - XILO D - XILO T - VELA XN
ALMA - ERA F S - ERA F BS - SIL S

code description boiler/water heater

08510060 Kit prolunga 1 mt. Ø 80 sdoppiata (condensa) FUTURIA L - FUTURIA N - FUTURIA PLUS

90
Accessories for wall-hung and floor-standing gas boilers – gas water heaters

code description boiler/water heater

08509840 split Ø80 90° bend kit FUTURIA L - FUTURIA N - FUTURIA PLUS - XILO-IN - XILO LN
XILO - XILO D - XILO T - VELA XN - ALMA - ERA F S - ERA F BS - SIL S

code description boiler/water heater

08506930 split Ø80 45° bend kit FUTURIA L - FUTURIA N - FUTURIA PLUS - XILO-IN - XILO LN
XILO - XILO D - XILO T - VELA XN - ALMA - ERA F S - ERA F BS - SIL S

code description boiler/water heater

08509460 Inspection stub pipe kit Ø 80 FUTURIA L - FUTURIA N - FUTURIA PLUS - XILO-IN - XILO LN
XILO - XILO D - XILO T - VELA XN - ALMA - ERA F S - ERA F BS - SIL S

code description boiler/water heater

08508090 tee reduction kit Ø 80/125 FUTURIA L - FUTURIA N - FUTURIA PLUS - XILO-IN - XILO LN
XILO - XILO D - XILO T - VELA XN - ALMA - ERA F S - ERA F BS - SIL S

code description boiler/water heater

08509660 external washer kit Ø 80 FUTURIA L - FUTURIA N - FUTURIA PLUS - XILO-IN - XILO LN
XILO - XILO D - XILO T - VELA XN - ALMA - ERA F S - ERA F BS - SIL S

code description boiler/water heater

08512030 internal washer kit Ø 80 FUTURIA L - FUTURIA N - FUTURIA PLUS - XILO-IN - XILO LN
XILO - XILO D - XILO T - VELA XN - ALMA - ERA F S - ERA F BS - SIL S

91
Accessories for wall-hung and floor-standing gas boilers – gas water heaters

• Split accessories for flue suction and discharge

code description boiler

08511360 split extension kit 0,5 mt. Ø 60 FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08511350 split extension kit 1 mt. Ø 60 FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08511280 split bend kit 90° Ø 60 FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08511290 split bend kit 45° Ø 60 FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08511380 inspection stub pipe kit Ø 60 FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08511390 vertical condensation collection stub pipe kit Ø 60 FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08511370 horizontal condensation collection stub pipe kit Ø 60 FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08511420 washer kit Ø 60 FUTURIA L - FUTURIA N - FUTURIA PLUS

08511410 air/flue terminal kit Ø 60 FUTURIA L - FUTURIA N - FUTURIA PLUS

92
Accessories for wall-hung and floor-standing gas boilers – gas water heaters

code description boiler

08511400 extension connection joint kit F/F Ø 60 FUTURIA L - FUTURIA N - FUTURIA PLUS

• External accessories for flue suction and discharge

code description boiler/water heater

08509830 External thermally insulated extension Kit 0,5 Mt XILO-IN - XILO LN - XILO - XILO D - XILO T - VELA XN
Ø 80 internal Ø 125 ALMA - ERA F S - ERA F BS - SIL S

code description boiler/water heater

08508370 External thermally insulated extension Kit 1 mt. XILO-IN - XILO LN - XILO - XILO D - XILO T - VELA XN
Ø 80 internal Ø 125 ALMA - ERA F S - ERA F BS - SIL S

code description boiler/water heater

08508400 condensation collection stub pipe kit Ø 80 XILO-IN - XILO LN - XILO - XILO D - XILO T - VELA XN
ALMA - ERA F S - ERA F BS - SIL S

code description boiler/water heater

08513590 Roof-top discharge terminal kit XILO-IN - XILO LN - XILO - XILO D - XILO T - VELA XN - ALMA
ERA F S - ERA F BS - SIL S

code description boiler/water heater

08508930 split insulated 90° bend kit XILO-IN - XILO LN - XILO - XILO D - XILO T - VELA XN
ALMA - ERA F S - ERA F BS - SIL S

code description boiler/water heater

08508950 neck kit for thermally insulated pipe Ø 125 XILO-IN - XILO LN - XILO - XILO D - XILO T - VELA XN
ALMA - ERA F S - ERA F BS - SIL S

93
Accessories for wall-hung and floor-standing gas boilers – gas water heaters

• Accessories for flue suction and discharge “BLACK LINE” Ø 80

code description boiler/water heater

08509610 extension kit 0,5 mt. Ø 80 FUTURIA L - FUTURIA N - FUTURIA PLUS - XILO-IN - XILO LN
XILO - XILO D - XILO T - VELA XN - ALMA - ERA F S - ERA F BS - SIL S

code description boiler/water heater

08509620 extension kit 1 mt. Ø 80 FUTURIA L - FUTURIA N - FUTURIA PLUS - XILO-IN - XILO LN - XILO
XILO D - XILO T - VELA XN - ALMA - ERA F S - ERA F BS - SIL S

code description boiler/water heater

08509630 extension kit 1,95 mt. Ø 80 FUTURIA L - FUTURIA N - FUTURIA PLUS - XILO-IN - XILO LN - XILO
XILO D - XILO T - VELA XN - ALMA - ERA F S - ERA F BS - SIL S

code description boiler/water heater

08509600 condensation collection 90° bend kit FUTURIA L - FUTURIA N - FUTURIA PLUS - XILO-IN - XILO LN - XILO
XILO D - XILO T - VELA XN - ALMA - ERA F S - ERA F BS - SIL S

code description boiler/water heater

08509640 spacer strip kit Ø 80 FUTURIA L - FUTURIA N - FUTURIA PLUS - XILO-IN - XILO LN - XILO
XILO D - XILO T - VELA XN - ALMA - ERA F S - ERA F BS - SIL S

code description boiler/water heater

08509650 strip kit Ø 80 FUTURIA L - FUTURIA N - FUTURIA PLUS - XILO-IN - XILO LN - XILO
XILO D - XILO T - VELA XN - ALMA - ERA F S - ERA F BS - SIL S

94
Accessories for wall-hung and floor-standing gas boilers – gas water heaters

code description boiler/water heater

08509660 washer kit Ø 80 FUTURIA L - FUTURIA N - FUTURIA PLUS - XILO-IN - XILO LN


XILO - XILO D - XILO T - VELA XN - ALMA - ERA F S - ERA F BS - SIL S

code description boiler/water heater

08509590 air terminal kit Ø 80 FUTURIA L - FUTURIA N - FUTURIA PLUS - XILO-IN - XILO LN
XILO - XILO D - XILO T - VELA XN - ALMA - ERA F S - ERA F BS - SIL S

code description boiler/water heater

08509670 flue terminal kit Ø 80 FUTURIA L - FUTURIA N - FUTURIA PLUS - XILO-IN - XILO LN - XILO
XILO D - XILO T - VELA XN - ALMA - ERA F S - ERA F BS - SIL S

code description boiler/water heater

08510040 inspection plate kit Ø 80 FUTURIA L - FUTURIA N - FUTURIA PLUS - XILO-IN - XILO LN - XILO
XILO D - XILO T - VELA XN - ALMA - ERA F S - ERA F BS - SIL S

code description boiler/water heater

08510030 wall-fastened bracket kit Ø 80 FUTURIA L - FUTURIA N - FUTURIA PLUS - XILO-IN - XILO LN - XILO
XILO D - XILO T - VELA XN - ALMA - ERA F S - ERA F BS - SIL S

• Accessories for flue suction and discharge “BLACK LINE”

code description boiler/water heater

08512050 extension kit 0,5 mt. Ø 60 FUTURIA L - FUTURIA N - FUTURIA PLUS

95
Accessories for wall-hung and floor-standing gas boilers – gas water heaters

code description boiler

08512060 extension kit 1 mt. Ø 60 FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08512070 extension kit 1,95 mt. Ø 60 FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08512080 condensation collection 90° bend kit Ø 60 FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08512100 spacer strip kit Ø 60 FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08512090 strip kit Ø 60 FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08511420 washer kit Ø 60 FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08511410 flue/air terminal kit Ø 60 FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08512110 flue terminal kit Ø 60 FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08512120 inspection plate kit Ø 60 FUTURIA L - FUTURIA N - FUTURIA PLUS

96
Accessories for wall-hung and floor-standing gas boilers – gas water heaters

• Plastic accessories for flue suction and discharge

code description boiler

08514360 wall discharge kit Ø60/Ø100 FUTURIA L - FUTURIA N 15 - FUTURIA N 25 - FUTURIA N 35


FUTURIA PLUS

code description boiler

08514720 roof-top discharge kit Ø60/Ø100 FUTURIA L - FUTURIA N 15 - FUTURIA N 25 - FUTURIA N 35


FUTURIA PLUS

code description boiler

08514640 split separate kit Ø80 FUTURIA L - FUTURIA PLUS

code description boiler

08514650 Kit sdoppiato separato Ø60 FUTURIA L - FUTURIA PLUS

code description boiler

08514700 berm discharge union kit FUTURIA L - FUTURIA N 15 - FUTURIA N 25 - FUTURIA N 35


FUTURIA PLUS

code description boiler

08514710 lead propeller nut kit FUTURIA L - FUTURIA N 15 - FUTURIA N 25 - FUTURIA N 35


FUTURIA PLUS

code description boiler

08514480 extension kit Ø60/Ø100 L = 0,5 mt FUTURIA L - FUTURIA N 15 - FUTURIA N 25 - FUTURIA N 35


FUTURIA PLUS

code description boiler

08514490 extension kit Ø60/Ø100 L = 1 mt FUTURIA L - FUTURIA N 15 - FUTURIA N 25 - FUTURIA N 35


FUTURIA PLUS

code description boiler

08514500 extension kit Ø60/Ø100 L = 2 mt FUTURIA L - FUTURIA N 15 - FUTURIA N 25 - FUTURIA N 35


FUTURIA PLUS

97
Accessories for wall-hung and floor-standing gas boilers – gas water heaters

code description boiler

08514560 extension kit Ø80 L = 0,5 mt FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08514570 extension kit Ø80 L = 1 mt FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08514580 extension kit Ø80 L = 2 mt FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08514530 extension kit Ø60 L = 0,5 mt FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08514540 extension kit Ø60 L = 1 mt FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08514550 extension kit Ø60 L = 2 mt FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08514520 bend kit 90° Ø60/Ø100 FUTURIA L - FUTURIA N 15 - FUTURIA N 25 - FUTURIA N 35


FUTURIA PLUS

code description boiler

08514510 bend kit 45° Ø60/Ø100 FUTURIA L - FUTURIA N 15 - FUTURIA N 25 - FUTURIA N 35


FUTURIA PLUS

code description boiler

08514450 bend kit 90° Ø80 FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08514460 bend kit 45° Ø80 FUTURIA L - FUTURIA N - FUTURIA PLUS

98
Accessories for wall-hung and floor-standing gas boilers – gas water heaters

code description boiler

08514420 bend kit 90° Ø60 FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08514430 bend kit 45° Ø60 FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08514670 flanged adapter kit Ø60/Ø100 FUTURIA L - FUTURIA N 15 - FUTURIA N 25 - FUTURIA N 35


FUTURIA PLUS

code description boiler

08514660 reduction kit Ø60M/Ø80F FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08514470 bend supporting kit Ø80 FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08514440 bend supporting kit Ø60 FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08515050 gasket lubricating kit / 5 parts FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08514410 spacer kit Ø60 FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08514620 spacer kit Ø80 FUTURIA L - FUTURIA N - FUTURIA PLUS

99
Accessories for wall-hung and floor-standing gas boilers – gas water heaters

code description boiler

08514610 flexible pipe flue covering kit Ø80 FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08514690 flue covering kit Ø80 FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08514680 flue covering kit Ø60 FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08514630 flexible pipe inspection kit Ø80 FUTURIA L - FUTURIA N - FUTURIA PLUS

code description boiler

08514600 flexible pipe kit Ø80 L = 25 mt FUTURIA L - FUTURIA N - FUTURIA PLUS

• Concentric accessories for flue suction and discharge for SAL water heaters
code description water heater

08513400 horizontal concentric discharge kit SAL 80 S - SAL 120 S


08513410 vertical concentric discharge kit SAL 80 S - SAL 120 S
08513430 horizontal concentric discharge kit SAL 150 S - SAL 180 S - SAL 220 S - SAL 300 S - SAL 400 S
08513420 vertical concentric discharge kit SAL 150 S - SAL 180 S - SAL 220 S - SAL 300 S - SAL 400 S
08513540 concentric extension kit 0,5 m Ø38/60 SAL 80 S - SAL 120 S
08513550 concentric extension kit 1 m Ø38/60 SAL 80 S - SAL 120 S
08513450 concentric extension kit 0,5 m Ø60/100 SAL 150 S - SAL 180 S - SAL 220 S - SAL 300 S - SAL 400 S
08513460 concentric extension kit 1 m Ø60/100 SAL 150 S - SAL 180 S - SAL 220 S - SAL 300 S - SAL 400 S
08513560 concentric 90° bend kit Ø38/60 SAL 80 S - SAL 120 S
08513570 concentric 90° bend kit Ø38/60 SAL 80 S - SAL 120 S
08513470 concentric 90° bend kit Ø60/100 SAL 150 S - SAL 180 S - SAL 220 S - SAL 300 S - SAL 400 S
08513480 concentric 90° bend kit Ø60/100 SAL 150 S - SAL 180 S - SAL 220 S - SAL 300 S - SAL 400 S

100
Accessories for wall-hung and floor-standing gas boilers – gas water heaters

• Split accessories for flue suction and discharge for SAL water heaters
code description water heater

08513440 split discharge kit Ø80 SAL 150 S - SAL 180 S - SAL 220 S - SAL 300 S - SAL 400 S
08513510 split extension kit 1 m Ø80 SAL 150 S - SAL 180 S - SAL 220 S - SAL 300 S - SAL 400 S
08513520 split extension kit 0,5 m Ø80 SAL 150 S - SAL 180 S - SAL 220 S - SAL 300 S - SAL 400 S
08513530 split extension kit 0,25 m Ø80 SAL 150 S - SAL 180 S - SAL 220 S - SAL 300 S - SAL 400 S
08513500 split bend kit 90° Ø80 SAL 150 S - SAL 180 S - SAL 220 S - SAL 300 S - SAL 400 S
08513490 split bend kit 45° Ø80 SAL 150 S - SAL 180 S - SAL 220 S - SAL 300 S - SAL 400 S

• Flue manifold kit CGL 2


Technical description
- AISI 304 stainless steel flue manifolds
- Installation can be performed at a distance A ranging from 0 to 100 mm.
A
code description water heater

08515820 flue manifold kit CGL 2/4 GASTER N 51 AW


08515830 flue manifold kit CGL 2/5 GASTER N 68 AW
08515840 flue manifold kit CGL 2/6 GASTER N 85 AW
08515850 flue manifold kit CGL 2/7 GASTER N 102 AW
08515860 flue manifold kit CGL 2/8 GASTER N 119 AW
08515870 flue manifold kitCGL 2/9 GASTER N 136 AW
08515880 flue manifold kit CGL 2/10 GASTER N 153 AW
08515890 flue manifold kit CGL 2/11 GASTER N 170 AW
08515900 flue manifold kit CGL 2/12 GASTER N 187 AW
08515910 flue manifold kit CGL 2/14 GASTER N 221 AW
08515920 flue manifold kit CGL 2/16 GASTER N 255 AW
08515930 flue manifold kit CGL 2/18 GASTER N 289 AW

• Flue manifold kit CGL 3


Technical description
- AISI 304 stainless steel flue manifolds
- Installation can be performed at a distance A ranging from 0 to 100 mm.
A A
code description water heater

08515940 flue manifold kit CGL 3/4 GASTER N 51 AW


08515950 flue manifold kit CGL 3/5 GASTER N 68 AW
08515960 flue manifold kit CGL 3/6 GASTER N 85 AW
08515970 flue manifold kit CGL 3/7 GASTER N 102 AW
08515980 flue manifold kit CGL 3/8 GASTER N 119 AW
08515990 flue manifold kit CGL 3/9 GASTER N 136 AW
08516000 flue manifold kit CGL 3/10 GASTER N 153 AW
08516010 flue manifold kit CGL 3/11 GASTER N 170 AW
08516020 flue manifold kit CGL 3/12 GASTER N 187 AW
08516030 flue manifold kit CGL 3/14 GASTER N 221 AW
08516040 flue manifold kit CGL 3/16 GASTER N 255 AW
08516050 flue manifold kit CGL 3/18 GASTER N 289 AW

101
Accessories for wall-hung and floor-standing gas boilers – gas water heaters

• “BASE” water connection kit


Technical description
- 5 nichel-plated copper pipes
- 1 gas cock Ø _”
- 1 gas cock Ø _”
- Nipples and various unions

code description boiler

08515640 “base” water connection kit FUTURIA L MT *


08514190 “base” water connection kit FUTURIA L MC *
08516130 “base” water connection kit FUTURIA L MT - FUTURIA N 15 MT - FUTURIA N 25 MT - FUTURIA N 35 MT
08516140 “base” water connection kit FUTURIA L MC - FUTURIA N MC
08514200 “base” water connection kit FUTURIA L MB - ALMA
08511940 “base” water connection kit XILO LN - XILO - XILO T - XILO D
08516360 “base” water connection kit VELA XN
* clearance sale

Technical description
- 5 nichel-plated copper pipes
- 1 gas cock Ø 3/4”
- 1 gas cock Ø 3/4”
- Nipples and various unions

code description boiler

08510080 comfort cock water connection kit FUTURIA PLUS

102
Accessories for wall-hung and floor-standing gas boilers – gas water heaters

• “universal” water connection kit


Technical description
- 5 stainless steel pipes
- 1 gas cock Ø 1/2”
- Nipples and various unions
code description boiler

08512240 stainless steel universal water connection kit FUTURIA L - FUTURIA PLUS - ALMA - VELA XN

• Heating module coupling kit


code description boiler

08514070 Kit accoppiamento Fumo/idraulico “riscaldamento” REPLY C


08514080 “sanitary” water coupling kit REPLY C

• Installation template

code description boiler

08516530 connection template FUTURIA N 15 MT - FUTURIA N 25 MT


08516540 connection template FUTURIA N 35 MT
08516550 connection template FUTURIA N 25 MC - FUTURIA N 35 MC
08515650 connection template FUTURIA L MT
08513910 connection template FUTURIA L MC
08513920 connection template FUTURIA L MB - ALMA
08511880 connection template XILO LN - XILO - XILO D
08512180 connection template XILO T 20
08512890 connection template XILO T 24
08512000 connection template VELA XN

• By-pass kit
Technical description
In the event of total closure of zone thermostatic valves or of thermostatic controls of heating units, it
assures boiler heating system circulation.
- By-pass valve – Union pipes
code description boiler

08511180 Kit by-pass XILO - XILO T

103
Accessories for wall-hung and floor-standing gas boilers – gas water heaters

• Disconnector kit
Technical description
It prevents heating system water from getting in contact with the water supply system water.
- disconnector – union pipes
code description boiler

08511260 Disconnector kit FUTURIA L - XILO - XILO T


08515620 Disconnector kit XILO-IN
08510200 Disconnector kit FUTURIA PLUS
08515610 Disconnector kit ALMA

• Room adjustment systems


– CLASS PIÚ Cronotermostat 1
– remote kit 4
4 1

code description boiler

00087520 cronotermostato CLASS PIÙ - 1 Tutti i modelli


08515630 time and date schedule kit ALMA
08512290 remote kit - 4 ALMA
08516150 remote kit FUTURIA N

• Electrical connection kit

code description boiler

08514880 boiler electrical connection kit FUTURIA L MT

104
Accessories for wall-hung and floor-standing gas boilers – gas water heaters

• Boiler management kit


code description boiler

08516390 Boiler management kit FUTURIA N 15 MT - FUTURIA N 25 MT


08516400 Boiler management kit FUTURIA N 35 MT
08516160 Boiler management kit FUTURIA N 50 MT

• Probe kit

code description boiler/heating module

08511210 Outdoor sensor FUTURIA N - REPLY N - BOX ZONE MIX


08510020 Outdoor sensor FUTURIA L - FUTURIA PLUS
08510000 boiler probe kit XILO T

• Management control panel kit

code description boiler/heating module

08516170 Management control panel kit FUTURIA N - REPLY N

• Kit sequenziatore

code description boiler/heating module

08516180 Sequencer kit All kind of boiler

• Water hammering preventing tank kit


Technical description
- 0.16 Lt. expansion tank – Safety valve Ø _ - Expansion tank pipe

code description water heater

08512840 Hammering preventing kit SIL - SIL S

• DPO anti-lime system


technical desription
- DPO _” doser type B, union pipes and connections

code description boiler/water heater

08902550 anti-lime DPO kit XILO-IN - XILO LN - XILO - XILO D - XILO T - ALMA - VELA XN - SIL

105
Accessories for wall-hung and floor-standing gas boilers – gas water heaters

• Conversion from natural gas to G.P.L.

code description boiler/water heater

08514220 Natural gas to LPG conversion kit FUTURIA L 24


08514230 Natural gas to LPG conversion kit FUTURIA L 28
08516190 Natural gas to LPG conversion kit FUTURIA N 15
08516200 Natural gas to LPG conversion kit FUTURIA N 25
08516210 Natural gas to LPG conversion kit FUTURIA N 35
08516220 Natural gas to LPG conversion kit FUTURIA N 50
08513940 Natural gas to LPG conversion kit XILO LN
08511160 Natural gas to LPG conversion kit XILO - XILO-IN
08511810 Natural gas to LPG conversion kit XILO D 20 - XILO T 20 - ALMA 24 MB/MBS - VELA XN
08511820 Natural gas to LPG conversion kit XILO D 24 MC - XILO T 24 M
08511930 Natural gas to LPG conversion kit XILO D 24 MCS - XILO T 24 MS
08507110 Natural gas to LPG conversion kit ALMA 28 MB/MBS - TREND 28
F39024770 Natural gas to LPG conversion kit ERA F 23
F39024780 Natural gas to LPG conversion kit ERA F 32 - ERA F 32 PK
F39024790 Natural gas to LPG conversion kit ERA F 45
F39024800 Natural gas to LPG conversion kit ERA F 56
08508520 Natural gas to LPG conversion kit GASTER N 51 A W
08508530 Natural gas to LPG conversion kit GASTER N 68 A W
08508540 Natural gas to LPG conversion kit GASTER N 85 A W
08508550 Natural gas to LPG conversion kit GASTER N 102 A W
08508560 Natural gas to LPG conversion kit GASTER N 119 A W
08508570 Natural gas to LPG conversion kit GASTER N 136 A W
08508580 Natural gas to LPG conversion kit GASTER N 153 A W
08508590 Natural gas to LPG conversion kit GASTER N 170 A W
08508600 Natural gas to LPG conversion kit GASTER N 187 A W
08516270 Natural gas to LPG conversion kit GASTER N 221 A W
08516280 Natural gas to LPG conversion kit GASTER N 255 A W
08516290 Natural gas toLPG conversion kit GASTER N 289 A W
08512930 Natural gas to LPG conversion kit SIL 14 - SIL 14 S

106
Accessories for wall-hung and floor-standing gas boilers – gas water heaters, Regulation systems and radiators

• Conversion from G.P.L. to natural gas

code description boiler/water heater

08514240 from LPG to natural gas conversion kit FUTURIA L 24


08514250 from LPG to natural gas conversion kit FUTURIA L 28
08516230 from LPG to natural gas conversion kit FUTURIA N 15
08516240 from LPG to natural gas conversion kit FUTURIA N 25
08516250 from LPG to natural gas conversion kit FUTURIA N 35
08516260 from LPG to natural gas conversion kit FUTURIA N 50
08515550 from LPG to natural gas conversion kit XILO (ugelli Ø 1,2) - XILO-IN
08513950 from LPG to natural gas conversion kit XILO LN
08511790 from LPG to natural gas conversion kit XILO (ugelli Ø 1,17)
08511840 from LPG to natural gas conversion kit XILO D - XILO T - ALMA - VELA XN - TREND - TREND L
08512940 from LPG to natural gas conversion kit SIL 14 - SIL 14 S

107
Accessories for gas and light oil boilers

• External air intake kit


Technical description
- rigid pipe Ø60 x 400 mm – flexible pipe Ø60 x 3 mm – suction terminal
- strip – 90° Ø60 aluminium pipe
code description burner/boiler

08025460 external air intake kit MINIA CI - MINIA R

• Recirculation circulator kit


Technical description
- 1 circulator – 2 recirculation pipes - gaskets

code description boiler

08512280 recirculation circulator kit MINIA CB

• Remote external probe kit

code description boiler

08511210 External probe kit MINIA CB - BOX ZONE MIX

• Remote kit

code description boiler

08512290 Remote kit MINIA CB

• Zone system kit


Technical description
- 1 circulator – 1 boiler-circulator stub pipe – 1 heating delivery pipe - Gaskets

code description boiler

08512250 Zone system kit MINIA CB

108
Accessories for gas and light oil boilers and radiators

• Zone management card kit

code description boiler

08512260 Zone management card kit MINIA CB

• Mixed zone kit


Technical description
- 1 circulator – 1 boiler-circulator stub pipe – 1 valve delivery-pipe – 1 circulator-valve pipe
- 1 mixed zone distributor – 1 three-way motor valve – 1 delivery probe
code description boiler

08512270 Mix zone kit MINIA CB

• Water connection kit with BITHERM boiler

code description boiler

08510830 Water connection kit NEINOX - NEINOX BT

• Kit sequenziatore

code description boiler

08516180 Sequencer kit All kind of boilers

109
Air heaters accessories

• Horizontal discharge kit


Technical description
- discharge duct L=1Mt., union strip with external gasket and terminal
code description air heater

08711370 Horizontal discharge kit Ø 80 AIR 21A÷ 30A - AIR 30AC


08711380 Horizontal discharge kit Ø 100 AIR 43A÷ 73A - AIR 43AC÷ 73AC

• Air suction kit


Technical description
- suction duct L=0.5 Mt. with external terminal, flexible pipe L=3 Mt. 2 hose clamps,
plug for burning air drawing.
code description air heater

08711390 Air suction kit Ø 140 AIR 21A÷ 73A - AIR 73AC

• Duct and bend kits


code description air heater

08506210 condensation discharge bend kit Ø 80 L=1 mt AIR 21A÷ 30A - AIR 30AC
08711410 condensation discharge bend kit Ø 100 L=1 mt AIR 43A÷ 73A - AIR 43AC÷ 73AC
08509840 condensation discharge bend kit 90° Ø 80 AIR 21A÷ 30A - AIR 30AC
08711430 condensation discharge bend kit 90° Ø 100 AIR 43A÷ 73A - AIR 43AC÷ 73AC
08711440 condensation discharge bend kit 90° Ø 80 AIR 21A÷ 30A - AIR 30AC
08711450 condensation discharge bend kit 90° Ø 100 AIR 43A÷ 73A - AIR 43AC÷ 73AC

• Roof-top discharge terminal Kit


Technical description
- discharge duct L=1Mt., union strip with external gasket and terminal, plastic material seal cap
complete with gasket and washer strip.
code description air heater

08711460 Roof-top discharge terminal Kit Ø 80 AIR 21A÷ 30A - AIR 30AC
08711470 Roof-top discharge terminal Kit Ø 100 AIR 43A÷ 73A - AIR 43AC÷ 73AC

• Lead propeller nut Kit


1 2

code description air heater

08507600 Kit raccordo scarico a terrazzo 1 AIR 21A÷ 73A - AIR 30AC÷ 73AC
08508100 berm discharge union kit 2 AIR 21A÷ 73A - AIR 30AC÷ 73AC

• Grid Kit with adjustable vertical fins

code description air heater

08711480 vertical grid kit AIR 21A - AIR 26A - AIR 30A
08711490 vertical grid kit AIR 43A - AIR 49A
08711500 vertical grid kit AIR 73A

110
Air heaters accessories

• Remote control panel with 10 Mt. cable

code description air heater

08711510 remote control panel AIR 21A÷ 73A - AIR 30AC÷ 73AC

• Kit mensola

code description air heater

08711520 Bracket kit AIR 21A÷ 73A - AIR 30ACE÷ 73ACE - IDRO LAMBY
08711540 Bracket kit AIR 30AC÷ 73AC

• Kit testata

code description air heater

08707290 Header kit LGE 25 - LGE 35


08707300 Header kit LGE 51 - LGE 65
08707280 Header kit LGE 80 - LGE 100
08707310 Header kit LGE 125 - LGE 150
08707320 Header kit LGE 175 - LGE 200
08707330 Header kit LGE 250 - LGE 300
08707340 Header kit LGE 375
08707350 Header kit LGE 425 - LGE 500
08707360 Header kit LGE 600
08707370 Header kit LGE 750
08707380 Header kit LGE 900

• Case filter kit

code description air heater

08707490 Case filter kit LGE 25 - LGE 35 - LGE 25 OUT - LGE 35 OUT
08707500 Case filter kit LGE 51 - LGE 65 - LGE 51 OUT - LGE 65 OUT
08707510 Case filter kit LGE 80 - LGE 100 - LGE 80 OUT - LGE 100 OUT
08707520 Case filter kit LGE 125 - LGE 150 - LGE 125 OUT - LGE 150 OUT
08707530 Case filter kit LGE 175 - LGE 200 - LGE 175 OUT - LGE 200 OUT
08707540 Case filter kit LGE 250 - LGE 300 - LGE 250 OUT - LGE 300 OUT
08707550 Case filter kit LGE 375 - LGE 375 OUT
08707560 Case filter kit LGE 425 - LGE 500 - LGE 425 OUT - LGE 500 OUT
08707570 Case filter kit LGE 600 - LGE 600 OUT
08707580 Case filter kit LGE 750 - LGE 750 OUT
08707590 Case filter kit LGE 900 - LGE 900 OUT

111
Accessories for air heaters and regulation systems

• Grid kit

code description air heater

08707390 Grid kit LGE 25 - LGE 35 - LGE 25 OUT - LGE 35 OUT


08707400 Grid kit LGE 51 - LGE 65 - LGE 51 OUT - LGE 65 OUT
08707410 Grid kit LGE 80 - LGE 100 - LGE 80 OUT - LGE 100 OUT
08708460 Grid kit LGE 125 - LGE 150 - LGE 125 OUT - LGE 150 OUT
08708470 Grid kit LGE 175 - LGE 200 - LGE 175 OUT - LGE 200 OUT
08708480 Grid kit LGE 250 - LGE 300 - LGE 250 OUT - LGE 300 OUT
08708490 Grid kit LGE 375 - LGE 375 OUT
08708500 Grid kit LGE 425 - LGE 500 - LGE 425 OUT - LGE 500 OUT
08708510 Grid kit LGE 600 - LGE 750 - LGE 600 OUT - LGE 750 OUT
08708520 Grid kit LGE 900 - LGE 900 OUT

• Probe kit

code description box zone

08511210 external probe kit BOX ZONE MIX

• Plugs, reductions, nipples, gaskets and bracket kit


code description Radiator

08300000 package kit of 10 1” right-hand white plugs all types


08300010 package kit of 10 1” left-hand white plugs all types
08300110 package kit of 10 1” to 1/8” right-hand white reductions all types
08300120 package kit of 10 1” to 1/8” left-hand white reductions all types
08300020 package kit of 10 1” to 1/4” right-hand nipples all types
08300030 package kit of 10 1” to 1/4” right-hand white reductions all types
08300040 package kit of 10 1” to 3/8” right-hand nipples all types
08300050 package kit of 10 1” to 3/8” right-hand white reductions all types
08300060 package kit of 10 1” to 1/2” right-hand nipples all types
08300070 package kit of 10 1” to 1/2” right-hand white reductions all types
08300080 package kit of 10 1” to 3/4” right-hand nipples all types
08300090 package kit of 10 1” to 3/4” right-hand white reductions all types
08300100 package kit of 10 1” to 3/4” right-hand nipples all types
F19999902 Kit conf. 100 guarnizioni da 1” all types
F19999905 package kit of 10 wall-fastened all types
F19999953 colour kit all types

112
Softeners Accessories

• Pulse shaper kit for softener volumetric regeneration


Technical description
– Mod. 3/4”: pulse shaper meter with brass turbine shell fitted with pulse shaper probe dry dial, roll direct reading for cold water.
– Mod. 1 1/4” - 1 1/2”- 2”- 3”: pulse shaper meters fitted with pulses emitter head, litre-counter, pulse shaper probe.

Code Description Softener

08902530 Pulse shaper kit (k 0,4 - 3/4”) EAU 8 E BIOS - EAU 15 E BIOS - EAU 22 E BIOS
08902440 Pulse shaper kit (k 0,4 - 1 1/4”) DOUBLE 35 E ÷ DOUBLE 65 E
08902080 Pulse shaper kit (k 0,1 - 1 1/2”) DOUBLE 85 E - DOUBLE 125 E - PLUS 165 E - PLUS 215 E
08902090 Pulse shaper kit (k 0,1 - 2”) PLUS 265 E ÷ PLUS 425 E
08902260 Pulse shaper kit (k 0,1 - 3”) PLUS 550 E

• Disinfecting Kit
Technical description
– This apparatus is intended for the protection against build up of bacteria which may arise from the softener cationic resins. Highly advanced
electrolytic automatic operation for the production of chlorine. The apparatus manufacturing complies to M.D. No. 443 of the 21/12/90.

Code Description Softener

08902420 CL 2 - KK 100 all up to 125 Lt. of resin (SWEET excluded)


08902580 CL 2 - SWEET SWEET 8-15-22 M

• Chemical products
– All the chemical products reported below are supplied by our Spare Parts Service
• Acquasil 20/40: anti-scale fluid for alimentary use, corrosion proofing for pumps of the PDPH 15-40 type.
• LPC Polifosf A: powdered – for softened water – alimentary use.
• LPC-A-010: fluid – for softened water – alimentary use.
• LPC-T-011: fluid – for raw water – heating system use
• LPC Polifosf B: powdered - for raw water – alimentary use.
• LPC-A-020: fluid - for raw water – alimentary use.
• LPC-T-021: fluid - for raw water – cooling tower use.
• LPC-A-030: fluid – for softened water – alimentary use – boiler conditioning system.
• LPC-A-031: fluid - for softened water – alimentary use – condensation steam line.
• LPC-T-040: algaecide fluid.
• LPC-T-050: powdered for boiler cleaning, exchangers, etc.

Code Description Package in kg

Corrosion inhibitors /anti-scale substances


04915010 Acquasil 20/40 1
Corrosion inhibitors
04905850 LPC Polifosf A 1
04906890 LPC-A-010 30
04906350 LPC-T-011 24
Anti-scale substances
04902800 LPC Polifosf B 1
04908260 LPC-A-020 26
04903090 LPC-T-021 26
Water conditioning system for steam boiler max 12 bar
04902970 LPC-A-030 30
04902980 LPC-A-031 24
Microbiocide
04907620 LPC-T-040 24
Scales remover
04903080 LPC-T-050 25

113
Fastening template

Futuria L MT Futuria L MC Futuria L MB - Alma

GS GS condensation
condensation condensation
discharge discharge SC discharge
MB M
M C
RB G
SC F
G
R
F
AE
R
AE

80

52
102
152
188
225
283
348
398

G Gas Ø 3/4” (boiler) Ø 1/2” (connections) C hot water Ø 1/2” C hot water Ø 1/2”
F boiler feeding water Ø 1/2” G Gas Ø 3/4” (boiler) Ø 1/2” (connections) G Gas Ø 3/4” (boiler) Ø 1/2” (connections)
AE power supply F Boiler feeding water Ø 1/2” F Boiler feeding water Ø 1/2”
M system delivery Ø 3/4” AE Power supply AE Power supply
R system return Ø 3/4” M system delivery Ø 3/4” M system delivery Ø 3/4”
MB boiler delivery Ø 3/4” R system return Ø 3/4” R system return Ø 3/4”
RB boiler return Ø 3/4” GS supporting hooks Ø 10 mm. RC water tank recirculation Ø 1/2”
GS supporting hooks Ø 10 mm. SC condensation discharge Ø 80 mm. GS supporting hooks Ø 10 mm.
SC condensation discharge Ø 80 mm. SC condensation discharge Ø 80 mm.
FS additional supporting holes Ø 10 mm.
N.B. provide with female connections N.B. provide with female connections N.B. provide with female connections

Futuria Plus
comfort water
connections kit

C Hot water Ø 1/2”


G Gas Ø 3/4”
F boiler feeding water Ø 1/2”
AE power supply
M system delivery Ø 3/4”
R system return Ø 3/4”
SC condensation discharge Ø 80 mm.

N.B. provide with female connections

114
Fastening templates

Xilo LN - Xilo - Xilo D Xilo T 20 Xilo T 24

C hot water Ø 1/2” G Gas Ø 3/4” (boiler) Ø 1/2” (connections) G Gas Ø 3/4” (boiler) Ø 1/2” (connections)
G Gas Ø 3/4” (boiler) Ø 1/2” (connections) F boiler feeding water Ø 1/2” F boiler feeding water Ø 1/2”
F boiler feeding water Ø 1/2” AE power supply AE power supply
AE power supply M system delivery Ø 3/4” M system delivery Ø 3/4”
M system delivery Ø 3/4” R system return Ø 3/4” R system return Ø 3/4”
R system return Ø 3/4” GS supporting hooks Ø 10 mm. MB boiler delivery Ø 3/4”
GS supporting hooks Ø 10 mm. RB boiler return Ø 3/4”
GS supporting hooks Ø 10 mm.

N.B. provide with female connections N.B. provide with female connections N.B. provide with female connections

115
Fastening templates

Vela XN Sil
13,5
GS
600 10
476 29 382 29
62
21,5 102,5 290 105
440
146

Fissaggio
Fix 675
staffa
System AE 854 900
G

C G F
126 24,5
226
110 110 110 110
304
382
452
522

C hot water Ø 1/2” C hot water Ø 1/2”


G Gas Ø 3/4” (boiler) Ø 1/2” (connections) G Gas
F boiler feeding water Ø 1/2” F boiler feeding water Ø 1/2”
AE power supply GS supporting hooks Ø 10 mm.
M system delivery Ø 3/4”
R system return Ø 3/4”
GS supporting hooks Ø 10 mm.

N.B. provide with female connections N.B. provide with female connections

116
Fastening templates

Silver S
328 272
292
57 95 50

75 69
a13
a12 a6
a1 a2
a10 a5
a11

706
a4
a7 70

421
225
201
191

155
162
122
72 a3 97
84 a9 102
167 a8

Boiler back
a1 system delivery Ø 1”
a2 Average temperature system return Ø 1”
a3 low temperature system return Ø 1”
a4 cold water inlet Ø 1/2”
a5 gas connection Ø 1/2”
a6 flue exhaust Ø 80”
a7 air inlet Ø 80”
a8 boiler discharge Ø 1/2”
a9 condensation discharge Ø 3/4”
a10 electric cable outlet Ø 40 mm.
a11 safety valve bleed Ø 14 mm.
a12 and a13 system zone delivery pipes Ø 1” (optional)

Silver BS
328 272
292
57 95 50
75 69

a13
a12 a6
a1 a9
a10 a8
a11 a2
a3 a5
a7 28 70
1111

a12
826
625
606

560
567
527

a13
302
77

a14
72 97
167 102

Boiler back

a1 system delivery Ø 1” a9 condensation discharge Ø 3/4”


a2 average temperature system return Ø 1” a10 electric cable outlet Ø 40 mm.
a3 low temperature system return Ø 1” a11 safety valve bleed Ø 14 mm.
a4 cold water inlet Ø 1/2” a12 boiler delivery Ø 3/4”
a5 gas connection Ø 1/2” a13 boiler recirculation Ø 3/4”
a6 flue exhaust Ø 80” a14 boiler return Ø 3/4”
a7 air inlet Ø 80”
a8 boiler discharge Ø 1/2” a12 and a13 system zone delivery pipes Ø 1” (optional)