Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
0% found this document useful (0 votes)
33 views

Assignment 3

The document contains an assignment with 10 questions related to applied electricity. It includes questions about calculating power delivered to loads, supply voltages, capacitance required for motor power factor correction, generator load calculations, output voltage and lead angle for an RL circuit, equivalent circuit expressions, cable selection based on current rating and voltage drop, explanation of earth electrode resistance testing and RCD testing, and discussing advantages and disadvantages of solar PV power systems. It asks the student to perform calculations and briefly explain various electrical concepts.

Uploaded by

Nilak lakshan
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views

Assignment 3

The document contains an assignment with 10 questions related to applied electricity. It includes questions about calculating power delivered to loads, supply voltages, capacitance required for motor power factor correction, generator load calculations, output voltage and lead angle for an RL circuit, equivalent circuit expressions, cable selection based on current rating and voltage drop, explanation of earth electrode resistance testing and RCD testing, and discussing advantages and disadvantages of solar PV power systems. It asks the student to perform calculations and briefly explain various electrical concepts.

Uploaded by

Nilak lakshan
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

FACULTY OF ENGINEERING, UNIVERSITY OF JAFFNA

APPLIED ELECTRICITY – EC1020


Assignment 03
 
1. For the circuit shown below, find:

a. The average power delivered to the load

b. The average power absorbed by the line

c. The apparent power supplied by the voltage source

d. The power factor of the load

e. The power factor of the line plus the load

5 𝑗5 

2. A circuit diagram is shown below. Calculate the supply voltage V .


3. A single phase motor connected to 400V, 50Hz supply which takes 31.7A at a
power factor of 0.7 lagging. Calculate the capacitance required in parallel which
the motor to raise the power factor to 0.9 lagging.

4. A single phase AC generator supplies the following loads:


 Lighting load of 20kW at unity power factor
 Induction motor load of 100kW at power factor of 0.707 lagging
Calculate the total KW and kVA delivered by the generator and power factor at
which it works.

5. For the RL circuit shown in Figure below, compute the output voltage and the
angle of lead.
R=280Ω

Vs=25V∠0o +
XL=200Ω Vout
-
 
 
6. The following two circuits are equivalent. Derive an expression for each R and
C in terms of Rs, Cs & ω.

Rs
A A

ZT Cs ZT RP CP

B B

7. A 6kW load is to be supplied at 230 V by a PVC sheathed and insulated twin and
cpc copper cable, 8 metres in length. The cable is clipped on the surface through
an area with an ambient temperature of 40°C and is grouped with three other
cables of similar size and loading. The protection is by means of a BS 3036 fuse.
It is assumed in this example that all the correction factors need to be applied)

Available fuses are 20A, 30A, 40A, 50A


Temperature factor (Ca ) = 0.94
Grouping factor (Cg ) = 0.65
Fusing factor (Cr ) = 0.725
I. Calculate the design current (Ib)
II. Select the type and current rating of the overcurrent device.
III. Calculate the tabulated current (It)
IV. Select the suitable cable.
V. Calculate the voltage drop using following formula and ensure that
voltage drop is not more than 5%.
Volts drop = mv/a/m x design current, Ib x length of run in metres, L
–––––––––––––––––––––––––––––––––––––––––––––––
1000

8. Briefly explain that how Earth Electrode Resistance test and RCD test.
9. What are the advantages and disadvantages of Solar PV power system?
10. Briefly explain the working principle of residual current circuit breaker.