Design of Steel Structure: Column Base (Refer IS:800-2007, Clause-7.4 Page No-46)
Design of Steel Structure: Column Base (Refer IS:800-2007, Clause-7.4 Page No-46)
Sometimes, a base plate of dimension greater than the requirement may have been provided. In such
cases the Clause 7.4.1.1 IS: 800-2007, Page no 46 has made the following specifications.
If the size of the base plate is larger than that required to limit the bearing pressure on the base support,
an equal projection c of the base plate beyond the Pace of the column and gusset may be taken as
effective in transferring the column load as given in Fig. 3, such that bearing pressure on the effective
area does not exceed bearing capacity of concrete base.
Q 1. Design the base plate for a column made of ISHB 250 @ 51.10 kg/m to carry a compressive
load of 780 kN. The grade of concrete used is M 20. Assume Fe 410 grade steel.
Where,
C1 = the portion of the base plate acting as a cantilever in mm
Fy = yield strength of steel in N/mm2
𝑤 =intensity of pressure calculated in step (iv)
6. Bolted/welded connections are designed and increase the number of bolts so it can be provided in
regular pattern.
Q 2. Design a gusseted base for a column ISHB 350 @ 710 N/m with two plates 450 mm x 20 mm
carrying a factored load of 2500 kN. The column is to be supported on concrete pedestal with M 20
grade concrete.