S-2-Cpuse-H-Ni6: Two-Way Reactive Power Splitter, 555-2700 MHZ

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

S-2-CPUSE-H-NI6

Two-way Reactive Power Splitter, 555–2700 MHz

OBSOLETE
This product was discontinued on: October 31, 2019
Replaced By:

S-2-UW-H-NI6 Ultra Wideband Two-way Low PIM Reactive High Power Splitter, 555–6000 MHz (Additional mounting
bracket PN:42396A-17 sold separately)

Product Classification
Regional Availability Asia    |   Australia/New Zealand    |   EMEA    |   Latin America    |   North America

Product Type Power splitter

General Specifications
Device Type Splitter

Application Indoor/Outdoor

Color Silver

Inner Contact Plating Silver

Interface N Female

Outer Contact Plating Trimetal

Dimensions
Height 25 mm   |   0.984 in

Width 61 mm   |   2.402 in

Length 150 mm   |   5.906 in

Outline Drawing

Page 1 of 3

©2021 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: March 21, 2021
S-2-CPUSE-H-NI6

Electrical Specifications
3rd Order IMD -160 dBc

3rd Order IMD Test Method Two +43 dBm carriers

Insertion Loss at Frequency Band 0.2 dB @ 555–2700 MHz

Return Loss, minimum 20.8 dB

Average Power, maximum 300 W

Impedance 50 ohm

Operating Frequency Band 555 – 2700 MHz

Peak Power, maximum 3 kW

Power Rating, Splitting 300 W

Reflected Power, maximum 300 W

Split Loss 3 dB

VSWR 1.2

Mechanical Specifications
Coupling Nut Proof Torque 4.5 N-m   |   39.828 in lb

Environmental Specifications
Operating Temperature -35 °C to +85 °C (-31 °F to +185 °F)

Relative Humidity Up to 100%

IEC 60529:2001, IP65 Page 2 of 3

©2021 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: March 21, 2021
S-2-CPUSE-H-NI6
Ingress Protection Test Method IEC 60529:2001, IP65

Packaging and Weights


Height, packed 40 mm   |   1.575 in

Width, packed 90 mm   |   3.543 in

Length, packed 180 mm   |   7.087 in

Volume 648000 mm³   |   39.544 in³

Weight, gross 0.32 kg   |   0.705 lb

Weight, net 0.26 kg   |   0.573 lb

Regulatory Compliance/Certifications
Agency Classification
CHINA-ROHS Above maximum concentration value
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system
ROHS Compliant/Exempted

Page 3 of 3

©2021 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: March 21, 2021

You might also like