Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

B3 P8 Rebar

Download as pdf
Download as pdf
You are on page 1of 2
on CHECKLIST FOR METAL / MODULAR SCAFFOLDING 42 ‘Main Gontractor: ACE WoPks 9B Project! SURG Cay Site Rog. Now ‘Scaffolding Information: cocato:.M622-83 “PE... one. wan ravingno: 1B! LF p6/ecet/olw (Fetrto sit avout plan) 6.0m High : Lift x Width .. Bay Type nna _ rmodularframedtibe) Materialia. BED ance Mmelused eS £5 /bn138/ 8%} vapenton to ES | Gere oes 6] Ten Yes Ne rarer T [FOUNDATION a |Scatfolds erected on firm ground 'b |Scaffolds not endangered by open excavation 2 |SOLEPLATES [Proper soloplates used IBASEPLATES JALIGNMENT OF SCAFFOLD COMPONENT lstandard or frame vertical [Ledger and transom levelled » ScarrOLD COMPONENT CONNECTOR. Standard comected ented wh he 3 soo » [Peo stated al vera ins baton oes won 6 [HORIZONTAL BRACING ORLACINS a a a IProper baseplates fited to all standard or leg of scaffolds | ~~ v “ - [At every 5 lift of frame or modular scaffold to bot! }& outer 7 [TIE BACK a {at every 2 lin or every tloor starting from the base |Space not more than 3 bays or 7.6 meters apart lwhichaver Is lesser manner 8 FOOT - TIE Foal - tes fitted to both inner and outer standards ‘9 WORKING PLATFORM [Continuos working platform at construction level solated viorking platforms are provided with proper |auardrals and securely fastened in postion 40 [Berricade to open sides of building v a ¢ \epace no further than one bay from the end, ina stagered | 7 v v uw Y Scanned with CamScanner Tem Yes | No Remarks Scaffold erecled one Miuabove the top most construction | | | level 412 | GUARDRAIL “ |Guardrall are fitted and connected to standard 19] TORSION CABLE (\t required by design) \rensioned torsion cable at every eantlaver bracket N/A 14|DEBRIS NET [Debris net to be erected to prevent partials and debris, lcistadged from scaffold falling on to the public access LADDER |Ledder aro secured to the scaffold atthe top and bottom TEMPORARY STRUCTURE INo scaffold is connected to a temporary structure PROFESSIONAL ENGINEER'S DRAWING |Soaffold are erected strclly in accordance to the [Professional Engineer's Drawing SCAFFOLD COMPONENT [Scaffold components and ftings showing no sign of ldetertoration [Al tings are tighton and undamaged |All components and fittings are fixed, secured and placed in position HOUSEKEEPING |Working platfrom, access ways and landing claerad ctf lany obstruction, loose objects and tripping haz | Scaffolding free from debris, unused formwork, icomponent and etc. ISIGNAGE Suitable signage/tags are place at appropriate ionation 18 16 7 Nc a NS ony. Tel & Fax No. 68000 Ampang, Selanaer| 5 “ei 09-92651861 Fax: 03 82001881" Co! Project Manager | Safety and Heath otter Scanned with CamScanner

You might also like