Mtu Engine Model12V4000G63 A. LT CIRCUIT (260 KW at 29 M /HR) Heat Exchanger: Gl-13Lx24 Duty Requirements

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

MTU ENGINE MODEL12V4000G63

A. LT CIRCUIT (260 KW @ 29 m³/Hr)

HEAT EXCHANGER: GL-13Lx24

DUTY REQUIREMENTS LT Water Raw


Water

Inlet temperature °C : 62.8


35.0
Outlet temperature °C : 55.0
41.4
Flow rate m³/h : 29.00
35.00

PLATE HEAT EXCHANGER

Heat load kW : 260.0


Total heat transfer area m² : 2.64
Calculated pressure drop kPa / kPa : 61 72
Number of channels : 11L
12L
Number of plates : 24

CONSTRUCTION DATA

Connection diameter :2½“ 2


½“
Connection standard : ANSI#150 B16.5
Connection locations in/out : S1/S3
S2/S4
Fluid hold-up volume dm³ : 3.6
4.0
Max. operating pressure / Test pressure bar : 6/9
Max. working temperature °C : 110
Length (C) mm : 250
Plate pack length (A) mm : 82
Width * Height mm : 320 * 832
Weight - full / Weight - empty kg : 140 / 130
MTU ENGINE MODEL12V4000G63

B. HT CIRCUIT (580 KW@ 56 m³/Hr)

HEAT EXCHANGER: GC-26Lx16

DUTY REQUIREMENTS HT Water Raw


Water

Inlet temperature °C : 100.0


35.0
Outlet temperature °C : 90.8
41.7
Flow rate m³/h : 56.00
75.00

PLATE HEAT EXCHANGER

Heat load kW : 580.0


Total heat transfer area m² : 3.64
Calculated pressure drop kPa / kPa : 42 70
Number of channels : 7L 8L
Number of plates : 16

CONSTRUCTION DATA
Connection diameter : 4” 4”
Connection standard : ANSI#150 B16.5
Connection locations in/out : S1/S2
S3/S4
Fluid hold-up volume dm³ : 7.0
8.0
Max. operating pressure / Test pressure bar : 6/9
Max. working temperature °C : 110
Length (C) mm : 641
Plate pack length (A) mm : 72
Width * Height mm : 460 * 1265
Weight - full / Weight - empty kg : 360 / 340
TECHNICAL SPECIFICATIONS

HEAT EXCHANGER: GC-8Hx22

MTU MACHINE MODELS - 12V4000G23 (14 KW @ 12 LPM)


- 12V4000G63 (14 KW @ 12 LPM)

DUTY REQUIREMENTS SIDE 1 SIDE


2

Fluid Side 1 DIESEL


Fluid Side 2 Water

Inlet temperature °C : 82.5


35.0
Outlet temperature °C : 37.0
39.1
Flow rate l/min : 12.00
50.00

PLATE HEAT EXCHANGER

Heat load kW : 14.00


Total heat transfer area m² : 1.50
Calculated pressure drop kPa / kPa :4 37
Number of channels : 10H
11H
Number of plates : 22

CONSTRUCTION DATA

Plate material : SS316


Plate thickness mm : 0.5
Gasket material : NBR
Frame type : GC-8
Frame material : IS2062 Gr. B
Bolt material : IS1367 (8.8)
Connection material : SS316
SS316
Connection diameter : 1” 1”
Connection standard : ANSI#150 B16.5
Connection locations in/out : S4/S3
S2/S1
Fluid hold-up volume dm³ : 1.3
1.4
Max. operating pressure / Test pressure bar : 6/9
Max. working temperature °C : 100
Length (C) mm : 195
Plate pack length (A) mm : 55
Width * Height mm : 180 * 774
Weight - full / Weight - empty kg : 50 / 40