Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

F940wgot-Twd-E: 7-I W I A

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

F940WGOT-TWD-E1-mentuke 02.4.

19 1:46 PM Page 2

GRAPHIC OPERATION TERMINALS

F940WGOT-TWD-E
7-INCH WIDE FOR INDUSTRIAL AUTOMATION
F940WGOT-TWD-E1-mentuke 02.4.19 1:46 PM Page 3

Improved Design Efficiency and Operability:


This model can also be installed vertically to fit in a narrow space. When preparing screens, layout either for h

An example of two-way split screen


Advantages of Split Screen:
Depending on machine specifications,
you may wish to have menu screens
or operation keys always displayed on
the screen. However, to create another
identical screen makes the design
complicated. A solution to this problem
is the screen dividing function, which
allows you to divide the screen into a part
(or parts) to show permanent information
and a part to show variable information.
● Example of screen display * For all screens, either the two-way or the three-way split form
for horizontal installation

When installed horizontally, the screen


can be divided into two or three parts.
An example of three-way
split screen

● Example of screen display


for vertical installation

–1–
F940WGOT-TWD-E1-mentuke 02.4.19 1:48 PM Page 8

7-inch 256-color TFT liquid crystal


display provides high clarity images.

F940WGOT-TWD-E
New GOT with
Ultra-WIDE Screen
and Additional
Functions!!
• Viewer Friendly WIDE Screen
• Improved Design Efficiency and
Operability
• Three Communications Channels
Incorporated to Enable Connection
with a multitude of peripheral
Equipment
• Easy to Monitor Communications
• Complete with New Useful Functions

y:
ther for horizontal or vertical installation can be selected.

Useful
: Auxiliary screen is used to show Applications
menus, operation keys, etc. that for Two-way
should be displayed permanently. Split Screen:
Main screen is used as a monitor Auxiliary screen
r screen, etc. on which the display is normally for
alterable. stationary display,
m • Main screen can have a maximum of 500 can also be used
variations to select. in a two-way split
• Main screen is as large as that of
part F940GOT (6-inch) and allows you to use
screen.
on screen data.
n.
ree-way split format can be selected on the operating system, however, the two formats cannot be used together.
1. Pressing a
numerical value
or an ASCII code
displays ten
keys on the
auxiliary screen.

2. When operation
is completed,
the original
auxiliary screen
is resumed.

–2–
F940WGOT-TWD-E1-mentuke 02.4.19 1:47 PM Page 5

Three Communication Channels


Incorporated to Enable Connection
with a Multitude of Peripheral
Equipment:
Three interface channels are incorporated as standard equipment
for communications with PC (COM2: RS-232C) and
PLC (COM1: RS-232C, COM0: RS-422).

COM2: RS-232C Interface


(D-SUB 9-Pin (Male))
Enables connection with a PC that has
Screen creation software or ladder preparation software.
PC-operated software:
GT-Designer
FX-PCS/WIN
GX-Developer (SWMD5C-GPPW)

Data transfer cables:


FX-232CAB-1
(3m; for PC RS-232C 9-pin connector)
FX-232CAB-2
(3m; for PC RS-232C half-pitch 14-pin connector)
F2-232CAB-1
(3m; for PC RS-232C 25-pin connector)

Power Terminal (DC24V)

COM1: RS-232C Interface


(D-SUB 9-Pin (Male))
Enables connection with a PLC or peripherals
equipped with an RS-232C interface such as:
MELSEC-Q series, 3rd party manufacturers PLC,
microcomputer board, printer, bar code reader etc.

COM0: RS-422 Interface


(D-SUB 9-Pin (Male))
Enables connection with a PLC equipped with
an RS-422 interface. MELSEC-FX/A/QnA series,
3rd party manufacturers PLC, microcomputer
board, etc.

Ladder monitoring and editing is also possible while displaying


image on the screen. (Two-port interface function is incorporated)
With MELSEC-F/A/QnA/Q series directly connected to CPU or QnA or Q series connected to a calculator link (Q mode), screen
display and ladder editing can be run concurrently.
*1: Refer to Specifications for details
PLC Bar code reader, of connectable PLCs.
PC
*1, 2 printer, etc. *3 *2: A single PLC can be
connected to either COM0
COM2 (RS-232C) K × K or COM1.
*3: A single bar code reader
COM1 (RS-232C) × K K or printer can be connected
to either COM1 or COM2.

COM0 (RS-422) × K ×

–3–
F940WGOT-TWD-E1-mentuke 02.4.19 1:47 PM Page 6

Easy to Monitor Communications


Connected PLCs and communication status can be monitored
Peripheral equipment profiles can be learned immediately from the screen where error
details and signal ON/OFF status are also displayed to help operate the machine with
confidence.

GOT ports:
COM0: RS-422 COM1: RS-232C COM2: RS-232C

Convenient Functions
A wide choice of languages provided for worldwide applications
Available languages:
English, Korean, Chinese (simplified and common styles of characters), Italian, Dutch,
Swedish, Spanish, German, Portuguese, French and Japanese (JIS first and second
level kanji). For GOT system screens only Japanese or English is available.
Editing and monitoring of list programs (FX series only)
Built-in FX-10P functions facilitate debugging and maintenance of sequence programs.
Applications
Allows minor program changes at the work site, eliminating the need to prepare
peripherals for that purpose. Even sudden troubleshooting and maintenance calls are
a snap. Reduces costs for customers who took delivery of machinery together with an
FX-10P Handy Programming Panel (HPP).
Functions and operations
The F940WGOT is equipped with built-in Read/Write/Insert/Delete and Monitor
functions for instruction list programs equivalent to those provided by the FX-10P
Handy Programming Panel (HPP).

PLC monitoring and operation can be authorized from


multiple units. (Up to 4 GOT units can be linked.)
A maximum of four units, WIDE GOT or GOT-F900 can be connected to a single PLC
(with direct CPU connection to MELSEC-FX/A/QnA/Q series or microcomputer).
(A Handy GOT can be connected only as the last unit in the chain)
*When connected to RS-422

Communications through Communications through Communications through Communications through


RS-422* RS-232C RS-422* RS-232C

30m 15m 30m 15m

F940WGOT-TWD uses COM0 and COM1 for these connections.

–4–
F940WGOT-TWD-E1-mentuke 02.4.19 1:47 PM Page 7

Description of Screen
Creation Software:
SWMD5C-GOTR-PACK (E) ( V )
This Windows-compatible software for screen creation is applicable to
all GOT-900 series products including GOT-A900 series and GOT-F900
series (F930GOT, F940GOT, F940WGOT and Handy GOT ).
This substantially upgraded software has been made easier to use and
understand, the menu systems and operability are redesigned to meet
developing customer needs.

Operating environment:
Pentium 133 MHz or over (recommended)
PC (OS) (Refer to the English version for SWMD5C-GOTR-PACKE ( V ).)
Disk drive (mandatory) CD-ROM drive
130 MB or over for standard installation (80 MB or over for installation and 50 MB or over
Hard disk capacity
for execution)
Refer to Specifications for connecting cables.

Improved Design
Applicable software and versions: Efficiency and Operability:
This model can also be installed vertically
Software Model to fit in a narrow space. WhenFunction
preparing screens, layout either for h
SW5D5C-GTWORKS SWMD5C-GOTR-PACK+GT Simulator (co-packaged)
An example of two-way
User screen split screen
creation software
GT Works SWMD5C-GOTR-PACK
for GOT-A900/F900 series of Split Screen:
Advantages
GT Simulator Depending
Used for simulating sequences on machine
and screens onspecifications,
PC
you may wish to have menu screens
SW5D5C-GOTR-PACK or operation keys always displayed on
GT Designer the screen. However, to create another
SWMD5C-GOTR-PACK Same as above
identical screen makes the design
complicated. A solution to this problem
GT Sumulator does
is thenot support
screen GOT-F900
dividing function, series.
which
allows you to divide the screen into a part
(or parts) to show permanent information
and a part to show variable information.
● Example of screen display * For all screens, either the two-way or the three-way split form
for horizontal installation

Quality of Graphics
When installed horizontally, the screen
Improved!!
can be divided into two or three parts.
This software solution provides quality graphics An example of three-way
drawn skillfully with 256 color tones to achieve split screen
a close resemblance to actual switches and
lamps. Included are graphics representing switch
ON/OFF positions or lamp ON/OFF status.
● Example of screen display
for vertical installation

–5–
F940WGOT-TWD-E1-mentuke 02.4.19 1:47 PM Page 4

External dimensions: unit: mm (inch)

Unit Panel cut out dimensions


Exterior color:
7-inch 256-color TFT liquid crystal Munsell 0.08 GY/7.64/0.81
or its equivalent
Weight:
display provides high clarity images. 1.1 kg (including a 0.1 kg

124 (4.88) +1(0.04)


bracket)

133 (5.24)

123 (4.84)
Accessory: Bracket

0
*An open space equal to

F940WGOT-TWD-E panel cut dimensions plus


about 10 mm of additional
space all around, is
necessary for bracket
installation.
Example:
226 (W)×144 (H)×35.3 (D) mm

New GOT with 215 (8.46)


5 (0.20)
70.6 (2.78) 206 (8.11) +1(0.04)
0
excluding screw height.

Ultra-WIDE Screen
and Additional
F900GOT Series Functions!!
Product Range • Viewer Friendly WIDE Screen
• Improved Design Efficiency and
930 940
Operability
• Three Communications Channels
Incorporated to Enable Connection
with a multitude of peripheral
Equipment
• Easy to Monitor Communications
• Complete with New Useful Functions

Handy 940W

y:
ther for horizontal or vertical installation can be selected.

Useful
: Auxiliary screen is used to show Applications
menus, operation keys, etc. that for Two-way
should be displayed permanently. Split Screen:
Main screen is used as a monitor Auxiliary screen
r screen, etc. on which the display is normally for
alterable. stationary display,
m • Main screen can have a maximum of 500 can also be used
variations to select. in a two-way split
• Main screen is as large as that of
part F940GOT (6-inch) and allows you to use
screen.
on screen data.
n.
ree-way split format can be selected on the operating system, however, the two formats cannot be used together.
1. Pressing a
numerical value
or an ASCII code
displays ten
keys on the
auxiliary screen.

2. When operation
is completed,
the original
auxiliary screen
is resumed.

–6
2–
F940WGOT-TWD-E1-mentuke 02.4.19 1:46 PM Page 1

■General specifications:
Item Specifications
Source voltage DC 24V +10%~ −15%
Current consumed Current consumed: 650 mA, Max.750 mA when the power is turned on (400 mA when backlight is out)
Fuse Pre-installed (not replaceable)
Allowable instantaneous interruption time 1ms for continuous operation
Battery PM-20BL lithium battery pre-installed (life: Approx. 5 years, warrantee 1 year)
Ambient temperature 0~50¡C (when installed horizontally), 0~40¡C (when installed vertically or installed flat with the screen facing up)
Ambient humidity 35~85%RH (no dew condensation permitted)
Operating atmosphere No corrosive gas and dust permitted
Frequency Acceleration Amplitude
Vibration applied
Conforms to With intermittent 10~57Hz 0.075mm ten times (for
Vibration resistance JIS B 3502 or vibration 57~150Hz 9.8m/s2 (1G) 80 min.) in each
IEC1131-2 10~57Hz 0.035mm of X, Y and Z
With continuous
vibration directions
57~150Hz 4.9m/s2 (1G)
Impact resistance Conforms to JIS B 3502 or IEC 1131-2 (147 m/s2 [15G], impact applied three times (11ms) in each of X, Y and Z directions)
Noise resistance Noise voltage:1,000Vp-p, Noise width:1 sec when a noise simulator with a frequency of 30~100 Hz is used
Withstand voltage AC500V for 1 min. (between terminals as a whole and earth terminal)
Insulation resistance 10MΩ or over (between power terminals as a whole and earth terminal when measured with a DC500V ohm meter)
Grounding Type D grounding; No grounding needed if grounding is impossible
Protection rating IP65F or equivalent

■Display unit specifications:


Item Specifications
TFT full-dot matrix, 256-color LCD
Display Size 7-inch 155.5 (W)× 87.8 (H) mm
No. of dots 480×234 dots
Indicating element Approx. 50,000 hours (warrantee 1 year)
Life Cold cathode tube; 50,000 hours or more with automatic light extinguishing function. Timing for switching off the light can be set by
Backlight
PLC. (warrantee 1 year)

■List of controllers connectable to GOT units:


Controller Connection method
Connected to RS-422 Connecting cable Connected to RS-232C Connecting cable
Mitsubishi Electric FX FX0, FX0S, FX1S, FX0N, FX1N, FX2N, FX2NC FX-50DU-CAB0 3m FX1S, FX1N: * When BD is in use
MELSEC FX1S series+FX1N-422-BD FX-50DU-CAB0L 3m FX1N-232-BD FX-232CAB-1 3m
FX1N series+FX1N-422-BD FX-50DU-CAB0-1M 1m FX0N-232ADP+FX1N-CNV-BD * When ADP is in use
FX2N series+FX2N-422-BD FX-50DU-CAB0-10M 10m FX2N: F2-232CAB-1 3m
FX-50DU-CAB0-20M 20m FX2N-232-BD
FX-50DU-CAB0-30M 30m FX0N-232ADP+FX2N-CNV-BD
FX2NC:
FX0N-232ADP
FX, FX2C series FX-40DU-CAB 3m
A AnN, AnA, AnS, AnSJ, A1SHJ, A2C, A2CJ, FX-40DU-CAB-10M 10m
A0J2H, AnU, A2US, A2USH FX-50DU-CABL 3m
QnA QnA
Q QCPU (Q mode): QC30R2 3m
Q02, Q02H, Q06H, Q12H, Q25H
QCPU (A mode):
Q02-A, Q02H-A, Q06H-A
Motion A171SCPU-S3, A171SHCPU, A172SHCPU, A273UHCPU Same as for A or QnA
Calculator link A series: AJ71UC24, A2SJ71UC24-R2/R4, A1SJ71C24-R2/R4, Check RS-422/232C with Connecting cable to be
(A, QnA, Q) A1SCPUC24-R2, A2CCPUC24 calculator link unconnected prepared by customer
QnA series: AJ71QC24, AJ71QC24-R2, AJ71QC24-R4, A1SJ71QC24,
A1SJ71QC24-R2
Q series (serial communication): QJ71C24, QJ71C24-R2
Omron C series Connected to the host link CQM1 series: CPU with host link function Check RS-422/232C with host Connecting cable to be
C200H series: host link unit CS1: host link link unconnected prepared by customer
Fuji Electric N series Connected to link unit NB series: NB-RS1-AC, NB-RS1-DC Check RS-422/232C with link Connecting cable to be
NJ series: NJ-RS2, NJ-R4, RS-232C interface incorporated CPU unit unconnected prepared by customer
(NJ-CPU-B16)
NS series: NS-RS1
Yaskawa Electric Machine Controller Connected to MEMOBUS unit: Check RS-422/232C with Connecting cable to be
CP9200H ¥ MEMOBUS unit 217F (CN1, 2, 3) MEMOBUS unit unconnected prepared by customer
MP920 ¥ CPU ,E,PBIS port (PORT 1, 2) ¥ MEMOBUS unit 217F (CN 1, 2, 3)
MP930 ¥ CPU ,E,PBIS port (PORT 1, 2)
Allen -Bradley SLC500 series Connected to programming port Connecting cable to be
SLC500 series: prepared by customer
SLC 5/03, SLC 5/04
Micrologix Micrologix 1000, 1200, 1500
SIEMENS S7 series Connected to programming port Check RS-422/232C with HMI Connecting cable to be
S7-300 series: 312IFM, 313, 314, 314IFM, 315, 315-2DP, 316 adapter unconnected prepared by customer
(HMI Adapter necesary)
S7-400 series: 412-1, 413-1, 413-2DP, 414-1, 414-2DP, 416-1, 416-2DP
Microcomputer board General-purpose RS-422 interface Connecting cable to be RS-232C interface Connecting cable to be
communications prepared by customer prepared by customer

New publication, effective Mar. 2002


L-173-1-C5351-B HI-0203 (OKA) Specifications subject to change without notice.