Series 51-SY5000/7000/9000
CAT.ES11-90B B
51-SY-B.qxd 09.3.18 11:10 AM Page 2
L3
A
Dimensions
Dimension
Model L1 L2 L3
51-SY5120-L
L1
104
51-SY5120-LL 15
51-SY5120-TT 120.8
40
L2
51-SY7120-L
118.2
51-SY7120-LL 18
51-SY7120-TT 135
51-SY9120-L
148.3
51-SY9120-LL 42 23
51-SY9120-TT 165.1
L2
Flow-rate Characteristics
Flow-rate characteristics
Series 1→4/2 (P→A/B) 4/2→5/3 (A/B→EA/EB)
C[dm3/(s·bar)] b Cv C[dm3/(s·bar)] b Cv
51-SY520 1.9 0.35 0.49 2.4 0.39 0.61
Body ported 51-SY720 4.1 0.23 0.93 3.3 0.33 0.81
51-SY920 7.0 0.33 1.7 7.6 0.35 2.0
51-SY540 2.4 0.41 0.64 2.8 0.29 0.66
Base mounted 51-SY740 4.1 0.41 1.1 4.1 0.29 1.0
51-SY940 7.9 0.34 2.0 9.6 0.43 2.6
Features 1
3 Types of Connectors
쎲 Easily maintained by adapting connector 쎲 IP65 compliant
for the lead wire (L- and LL-type) (TT-type)
L-type
LL-type
L-type plug connector (L-type) L-type plug connector with cover (LL-type) Terminal type (TT-type)
3 Types of Barriers
Features 2 B
Intrinsically Safe Explosion-proof System
5 Port Solenoid Valve
Series 51-SY5000/7000/9000
Body Ported
Single Unit
How to Order
51 SY 5 1 20 A LL 3 01
Series Bracket
5 51-SY5000 Thread type Nil: Without bracket
F1: With foot bracket
7 51-SY7000 Nil Rc
2-position
9 51-SY9000 F G single only
N NPT
Explosion-proof
T NPTF
Intrinsically safe
51 explosion-proof
structure
A, B port size
Thread piping
Type of actuation Symbol Port size Applicable series
2-position single 01 1/8 51-SY5000
F2: With side bracket
02 1/4 51-SY7000
1
02 1/4
51-SY9000
03 3/8
2-position double One-touch fitting (Metric size) Note)
Symbol Port size Applicable series
2
C4 ø4 one-touch fitting ∗ The 51-SY9000 has no
C6 ø6 one-touch fitting 51-SY5000 bracket.
3-position closed center C8 ø8 one-touch fitting
C8 ø8 one-touch fitting
3 Note) 51-SY7000
C10 ø10 one-touch fitting
C8 ø8 one-touch fitting Note) Warning
3-position exhaust center C10 ø10 one-touch fitting 51-SY9000 If a resin tube is used,
C12 ø12 one-touch fitting take measures against
Note)
4 static electricity.
Manual override
3-position pressure center Nil: Non-locking push D: Push-turn locking E: Push-turn locking
type slotted type lever type
Note)
5
Terminal type
TT Note)
Specifications
Solenoid Specifications
Response Time
Note) Based on dynamic performance test, JIS B 8375-1981.
(Coil temperature: 20°C, system A, B, F at 24 VDC)
2A
51-SY-B.qxd 09.3.18 11:10 AM Page 6
Series 51-SY5000/7000/9000
Flow-rate Characteristics
Series 51-SY5000 Series 51-SY9000
Port size Flow-rate characteristics Note) Port size Flow-rate characteristics
Valve Type of Valve Type of
1, 5, 3 4, 2 1→4/2 (P→A/B) 4/2→5/3 (A/B→EA/EB) 1, 5, 3 4, 2 1→4/2 (P→A/B) 4/2→5/3 (A/B→EA/EB)
model actuation C(dm3/ C(dm3/ model actuation C(dm3/ C(dm3/
(P, EA, EB) (A, B) b Cv b Cv (P, EA, EB) (A, B)
(s·bar)) (s·bar)) (s·bar)) b Cv (s·bar)) b Cv
2- Single
position Double 1.9 0.35 0.49 2.4 0.39 0.61 51-SY9 2- Single
Closed 20- position 1/4 7.0 0.33 1.7 7.6 0.35 2.0
51-SY5 1.7 0.43 0.45 1.8 0.35 0.46 -02 Double
center
20- 3- Exhaust 1/8
-01 position center 1.5 0.44 0.41 2.5 0.32 0.59
[1.5] [0.43] [0.40] 51-SY9 2- Single
Pressure 2.2 0.46 0.61
1.8 0.38 0.46
20- position 3/8 8.0 0.29 1.9 8.0 0.33 2.0
center [0.91] [0.58] [0.28] -03 Double
2- Single 0.75 0.43 0.20 0.85 0.64 0.30
position Double C4 C8
Closed Single ø8
51-SY5 ø4 0.74 0.40 0.19 0.84 0.57 0.28 51-SY9 2-
20-
center one- 20- one- 4.3 0.28 0.96 7.1 0.32 1.7
-C4
3- Exhaust touch 0.75 0.36 0.19 0.84 0.64 0.30 -C8 position touch
position center [0.84] [0.53] [0.27] Double 1/4 fitting
fitting
Pressure 0.78 0.44 0.21 0.84 0.57 0.27
center [0.71] [0.37] [0.18] C10
1/8 Single ø10
2- Single 1.5 0.33 0.33 2.0 0.37 0.52
51-SY9 2-
position Double C6 20- one- 6.1 0.28 1.4 7.9 0.33 1.9
Closed ø6 -C10 position touch
51-SY5 1.3 0.31 0.33 1.6 0.32 0.39 Double fitting
center one-
20- 3- Exhaust
-C6 position center
touch 1.3 0.33 0.33 1.8 0.35 0.44 C12
fitting [1.4] [0.37] [0.35]
Double ø12
Pressure 1.7 0.31 0.42 51-SY9 2-
center 1.7 0.33 0.44 20- one- 7.0 0.25 1.6 8.6 0.41 2.2
[0.80] [0.47] [0.23]
2- Single -C12 position touch
1.9 0.21 0.45 2.3 0.29 0.57 Single fitting
position Double C8
Closed ø8 1.6 0.29 0.39 1.7 0.38 0.46
51-SY5 center
20- one-
3- Exhaust
-C8 position center
touch 1.4 0.38 0.39 2.0 0.37 0.52
fitting [1.5] [0.41] [0.43]
Pressure 2.2 0.32 0.56
center 1.8 0.41 0.50
[1.6] [0.44] [0.44]
Note) [ ]: Normal position
Series 51-SY7000
Port size Flow-rate characteristics Note)
Valve Type of
1, 5, 3 4, 2 1→4/2 (P→A/B) 4/2→5/3 (A/B→EA/EB)
model actuation 3 C(dm3/
(P, EA, EB) (A, B) C(dm / b Cv b Cv
(s·bar)) (s·bar))
2- Single 4.1 0.23 0.93 3.3 0.33 0.81
position Double
Closed 2.9 0.31 0.70 2.4 0.38 0.63
51-SY7 center
20- 3- Exhaust 1/4
-02 2.5 0.39 0.65 [2.1] 3.4 0.35 0.82
position center [0.38] [0.54]
Pressure 4.3 0.23 0.97
center 2.2 0.39 0.58
[2.4] [0.32] [0.61]
2- Single 1 (P) 3.2 0.26 0.77 3.2 0.37 0.82
position Double port C8
Closed 1/4 ø8 2.6 0.24 0.63 2.4 0.31 0.62
51-SY7 center
20- one-
3- Exhaust 5, 3
-C8 position center (EA, EB)
touch 2.4 0.25 0.57 2.6 0.42 0.70
fitting [1.9] [0.46] [0.56]
Pressure port 3.3 0.28 0.78
center 1/8 [2.4] [0.22] [0.57] 2.2 0.34 0.60
2- Single 3.8 0.26 0.86 3.2 0.34 0.82
position Double C10
Closed ø10 2.8 0.27 0.67 2.4 0.21 0.59
51-SY7 center one-
20- 3- Exhaust touch
-C10 position center 2.5 0.25 0.59 2.7 0.38 0.70
fitting [2.0] [0.38] [0.56]
Pressure 3.8 0.25 0.89
center [2.4] [0.31] [0.61] 2.3 0.38 0.61
Note) [ ]: Normal position
3
51-SY-B.qxd 09.3.18 11:10 AM Page 7
Construction
Series SY
2-position single
Symbol
w ry q e
2-position single (A) (B)
4 2
5 1 3
(EA) (P) (EB) t
Symbol
2-position double 2-position double
w y qr
(A) (B)
4 2
5 1 3
(EA) (P) (EB) t
Symbol 3-position closed center/exhaust center/pressure center
3-position closed center
wy qr
(A) (B)
4 2
3-position exhaust center
Replacement Parts
No. Description Part no.
Refer to “How to Order Port Block
6 Port block assembly
Assembly” on page 5.
Series 51-SY5000/7000/9000
SY 000 6A
Series
5 51-SY5000 Thread type
7 51-SY7000 Nil Rc
9 51-SY9000 F G
N NPT
T NPTF
A, B port size
Thread piping
Symbol Port size Applicable series
01 1/8 51-SY5000
02 1/4 51-SY7000
02 1/4
51-SY9000
03 3/8
One-touch fitting (Metric size) One-touch fitting (Inch size)
Symbol Port size Applicable series Symbol Port size Applicable series
C4 ø4 one-touch fitting N3 ø5/32" one-touch fitting
C6 ø6 one-touch fitting 51-SY5000 N7 ø1/4" one-touch fitting 51-SY5000
C8 ø8 one-touch fitting N9 ø5/16" one-touch fitting
C8 ø8 one-touch fitting N9 ø5/16" one-touch fitting
51-SY7000 51-SY7000
C10 ø10 one-touch fitting N11 ø3/8" one-touch fitting
C8 ø8 one-touch fitting N9 ø5/16" one-touch fitting
51-SY9000
C10 ø10 one-touch fitting 51-SY9000 N11 ø3/8" one-touch fitting
C12 ø12 one-touch fitting
Mounting
screw
Port block assembly
(Cassette type)
Fitting
assembly
5
51-SY-B.qxd 09.3.18 11:11 AM Page 9
Dimensions: 51-SY5000
2-position single With foot bracket
L-type plug connector (L) 51-SY5120-L-01-F1
51-SY5120-L-01 (-F2)
22.6 21
47
16.7
38 4.5
16.6
22
29
2 x M3 x 0.5 thread depth 3.5
(For mounting bracket) 14.7 2 x ø3.2
65 40 (For mounting)
11.6
Insulator: Black (–)
B
A
111.8
44 (E-type)
0.3 mm2
14.7
(40.2)
(36.7)
40
32.5
20.5
ø1.55
(1.2) (32.3)
1.2
L (Lead wire length) 109.1
(11.7)
32.5 10.5
3 x 1/8" 32.3
0.8
(20)
15
EA P EB
2 x ø2.2
(For manifold gasket positioning) 27.2
(45)
14.7
0.3 mm2
12
0.75 mm2
Max.10
6
51-SY-B.qxd 09.3.18 11:11 AM Page 10
Series 51-SY5000/7000/9000
Dimensions: 51-SY5000
2-position double
22.6
L-type plug connector (L)
51-SY5220-L-01 (-F2)
16.7
2 x M3 x 0.5 thread depth 3.5
(For mounting bracket)
65.4
11.6
Insulator: Black (–)
B
A
0.3 mm2
(36.7)
40
32.5
(40.2)
20.5
14.7
ø1.55
(20)
15
EA P EB
27.2
2 x ø2.2
(For manifold gasket positioning) (45)
0.3 mm2
14.7
(71.7)
0.75 mm2
12
(88.5)
7
51-SY-B.qxd 09.3.18 11:11 AM Page 11
Dimensions: 51-SY5000
3-position closed center/exhaust center/pressure center
L-type plug connector (L) 22.6
3
51-SY5 45 20-L-01 (-F2)
16.7
2 x M3 x 0.5 thread depth 3.5
(For mounting bracket)
(89.4)
32.7 45.3
11.6
Insulator: Black (–)
B
A
(37)
(2 x ø3.2 mounting hole)
0.3 mm2
44 (E-type)
(36.7)
40
32.5
(40.2)
20.5
14.7
ø1.55
(20)
15
EA P EB
27.2
2 x ø2.2
(For manifold gasket positioning) (45)
0.3 mm2
14.7
84.3
0.75 mm2
12
101.1
8
51-SY-B.qxd 09.3.18 11:11 AM Page 12
Series 51-SY5000/7000/9000
Dimensions: 51-SY7000
2-position single With foot bracket
L-type plug connector (L) 51-SY7120-L-02-F1
51-SY7120-L-02 (-F2)
2 x M4 x 0.7 thread depth 6.5 20 29.4 57
(For mounting bracket) 46 5.5
19.8
28
38
14.7
79.2
40
13.6
Insulator: Black (–) Manual override
B
A
Insulator: Red (+)
2 x ø4.2
20
(manifold mounting hole)
42 2 x 1/4"
44 (E-type)
125
(49.5)
0.3 mm2
(42.5)
40
40
24.5
14.7
(39.4)
L (Lead wire length) 123.3
1.2
1/4"
{P(1) port} 40 12.5
2 x 1/8"
0.9
(23.9)
18
EA P EB
36
2 x ø2.2
(For manifold gasket positioning) (66)
14.7
0.3 mm2
12
0.75 mm2
9
51-SY-B.qxd 09.3.18 11:11 AM Page 13
Dimensions: 51-SY7000
2-position double
L-type plug connector (L) 2 x M4 x 0.7 thread depth 6.5 20
(For mounting bracket)
51-SY7220-L-02 (-F2)
7
79.6
Insulator: Black (–)
B
13.6
A
Insulator: Red (+)
Manual override 2 x ø4.2
20
(manifold mounting hole)
42
2 x 1/4"
{A(4), B(2) port}
(52)
(2 x ø4.2 mounting hole)
44 (E-type)
0.3 mm2
(42.5)
(49.5)
40
40
24.5
14.7
ø1.55
(1.2)
(14) L (Lead wire length) 167.8
1/4"
{P(1) port}
2 x 1/8" (83.9)
{EA(5), EB(3) port}
0.9
2
18
EA P EB
(23.9)
2 x ø2.2 36
(For manifold gasket positioning) (66)
0.3 mm2
14.7
(78.8)
0.75 mm2
12
(95.6)
10
51-SY-B.qxd 09.3.18 11:11 AM Page 14
Series 51-SY5000/7000/9000
Dimensions: 51-SY7000
3-position closed center/exhaust center/pressure center
L-type plug connector (L)
3 2 x M4 x 0.7 thread depth 6.5 20
51-SY7 45 20-L-02 (-F2) (For mounting bracket)
7
39.8 52.8
Insulator: Black (–)
B
13.6
A
Insulator: Red (+)
Manual override 2 x ø4.2
20
(manifold mounting hole)
42
2 x 1/4"
{A(4), B(2) port}
(52)
(2 x ø4.2 mounting hole)
ø1.55
44 (E-type)
0.3 mm2
(42.5)
(49.5)
40
24.5
40
14.7
EA P EB
2
36
(23.9)
2 x ø2.2
(For manifold gasket positioning) (66)
0.3 mm2
14.7
91.8
0.75 mm2
12
108.6
11
51-SY-B.qxd 09.3.18 11:11 AM Page 15
Dimensions: 51-SY9000
2-position single
L-type plug connector (L)
03
51-SY9120-L- 02
109.3
6.5 (56.3)
Insulator: Black (–)
4 A 2 B
18.4
Insulator: Red (+)
Manual override
33.6 3 x ø3.2
64.2 (manifold mounting hole)
2 x 1/4", 3/8"
{4(A), 2(B) port}
46 (E-type)
0.3 mm2
51.5
42
36.6
16.7
ø1.55
10
(12) 2 x ø4.4 24.9 43.85
(Mounting hole)
L (Lead wire length) 153.4
3 x 1/4" 56.3
0.5
5 EA 1 P 3 EB
0.5
49.8
0.3 mm2
0.75 mm2
Max.10
12
51-SY-B.qxd 09.3.18 11:11 AM Page 16
Series 51-SY5000/7000/9000
Dimensions: 51-SY9000
2-position double
L-type plug connector (L)
03
51-SY9220-L- 02
106
6.5
Insulator: Black (–)
18.4
4 A 2 B
46 (E-type)
0.3 mm2
51.5
42
36.6
16.7
ø1.55
10
(12) 2 x ø4.4 24.9
(Mounting hole)
L (Lead wire length) 194.2
97.1
3 x 1/4" 0.5
{1(P), 3(EB), 5(EA) port}
23
5 EA 1 P 3 EB
0.5
49.8
0.3 mm2
0.75 mm2
Max.10
13
Intrinsically Safe Explosion-proof System
5 Port Solenoid Valve
Series 51-SY5000/7000/9000
Base Mounted
Single Unit
How to Order
51 SY 5 2 40 A LL
Thread type
Series
Nil Rc
5 51-SY5000
F G
7 51-SY7000
N NPT
9 51-SY9000
T NPTF
Port size
Explosion-proof
Symbol Port size Applicable series
Intrinsically safe
51 explosion-proof Nil Without sub-plate
structure 1/4 51-SY5000
02
With sub-plate 51-SY7000
Type of actuation 3/8 51-SY7000
03
With sub-plate 51-SY9000
2-position single
1/2
04 51-SY9000
1 With sub-plate
Manual override
2-position double Nil: Non-locking push D: Push-turn locking E: Push-turn locking
type slotted type lever type
2
4 Note)
Lead wire length
3-position pressure center Symbol Lead wire length Note
3 300 mm —
5 Note) 6 600 mm Maximum length for L-type
10 1000 mm —
15 1500 mm —
Note) 3-position type is not
available for the 51- 20 2000 mm —
SY9000 series. 30 3000 mm —
Pilot type
100 10000 mm Semi-standard
Nil Internal pilot
R External pilot Electrical entry
Symbol Electrical entry
L-type plug connector
System Note 1) Note 2)
A Z728.H (51-SYE100-A) L
B MTL728P + (51-SYE100-B)
F KFD0-SD2-Ex1.1065 (51-SYE100-F)
Note 1) Attached barrier type L-type plug connector
The numbers in ( ), 51-SYE100-쏔 with cover
represents SMC’s control number. LL
Note 2) If the barrier is not necessary due to
valve replacement etc, enter O after the
system symbol.
Example) 51-SY5140-AOLL3 Terminal type
TT Note)
Specifications
Solenoid Specifications
Response Time
Note) Based on dynamic performance test, JIS B 8375-1981.
(Coil temperature: 20°C, system A, B, F at 24 VDC)
A 15
51-SY-B.qxd 09.3.18 11:11 AM Page 19
Flow-rate Characteristics
Series 51-SY5000
Flow-rate characteristics Note)
Valve model Type of actuation Port size 1→4/2 (P→A/B) 4/2→5/3 (A/B→EA/EB)
C(dm3/(s·bar)) b Cv C(dm3/(s·bar)) b Cv
2- Single
2.4 0.41 0.64 2.8 0.29 0.66
position Double
Closed center 1.8 0.47 0.50 1.8 0.40 0.47
51-SY540-
1/4 3.0 0.33 0.72
-02 3- Exhaust center 1.4 0.55 0.44
[1.2] [0.48] [0.37]
position
3.3 0.36 0.85
Pressure center 1.8 0.40 0.48
[0.84] [0.60] [0.28]
Note) [ ]: Normal position
Series 51-SY7000
Flow-rate characteristics Note)
Valve model Type of actuation Port size 1→4/2 (P→A/B) 4/2→5/3 (A/B→EA/EB)
C(dm3/(s·bar)) b Cv C(dm3/(s·bar)) b Cv
2- Single
4.1 0.41 1.1 4.1 0.29 1.0
position Double
Closed center 3.0 0.43 0.80 2.6 0.41 0.72
51-SY740-
1/4 4.7 0.35 1.1
-02 3- Exhaust center 2.6 0.42 0.71
[1.7] [0.48] [0.49]
position
5.3 0.39 1.3
Pressure center 2.2 0.49 0.63
[2.3] [0.49] [0.65]
2- Single
4.9 0.29 1.2 4.5 0.27 1.1
position Double
Closed center 3.0 0.40 0.80 2.6 0.45 0.73
51-SY740-
3/8 4.8 0.35 1.1
-03 3- Exhaust center 2.6 0.42 0.71
[1.7] [0.48] [0.49]
position
5.3 0.31 1.3
Pressure center 2.3 0.45 0.66
[2.3] [0.51] [0.64]
Note) [ ]: Normal position
Series 51-SY9000
Flow-rate characteristics
Valve model Type of actuation Port size 1→4/2 (P→A/B) 4/2→5/3 (A/B→EA/EB)
C(dm3/(s·bar)) b Cv C(dm3/(s·bar)) b Cv
51-SY940- 2- Single
3/8 7.9 0.34 2.0 9.6 0.43 2.6
-03 position Double
51-SY940- 2- Single
1/2 8.0 0.48 2.2 10 0.29 2.5
-04 position Double
16
51-SY-B.qxd 09.3.18 11:11 AM Page 20
Series 51-SY5000/7000/9000
Construction
Series SY
Symbol
2-position single 2-position single wr t q e
4 2
y
u (A) (B)
5 1 3
(EA) (P) (EB)
Symbol
2-position double 2-position double
wr t q
u 4
(A)
2
(B) y
5 1 3
(EA) (P) (EB)
Symbol
3-position closed center 3-position closed center/exhaust center/pressure center
wr t q
4 2
u (A) (B)
y
5 1 3
3-position pressure center (EA) (P) (EB)
Component Parts
No. Description Material Note
1 Body Aluminum die-casted White
White
2 Adapter plate Resin
(51-SY9000: Gray)
3 End plate Resin White
4 Piston Resin —
5 Spool valve assembly Aluminum, HNBR —
17
51-SY-B.qxd 09.3.18 11:11 AM Page 21
Dimensions: 51-SY5000
2-position single
L-type plug connector (L)
18 19
51-SY5140(R)-L-02
9.5
37.2 2 x ø4.3 60.3
4
(External pilot port)
Insulator: Black (–) A B
17.5
35
B
A
Insulator: Red (+)
PE
X
EA P EB
Manual
17 override 56 4.3 17
65 62.5
M5 x 0.8
(Pilot EXH port) 109.1
<For external pilot type>
0.3 mm2
ø1.55
22
9.5
(E-type)
18 18
66.5
28 5 x 1/4"
(Piping port)
0.3 mm2
ø4.1
37.2
0.75 mm2
ø5.9
34.5
18
51-SY-B.qxd 09.3.18 11:11 AM Page 22
Series 51-SY5000/7000/9000
Dimensions: 51-SY5000
2-position double 18 19
L-type plug connector (L)
9.5
51-SY5240(R)-L-02
37.2
15.5 48 4 15.5
2 x ø4.3
M5 x 0.8
4
(For mounting)
Insulator: Black (–) (External pilot port)
A B
17.5
17.5
B
A
PE
X
Insulator: Red (+) Manual EA P EB
override
35
17 17
56
M5 x 0.8 65.4 62.5
(Pilot EXH port) 153.6
<For external pilot type>
0.3 mm2
22
(E-type)
9.5
18 18
66.5
28 5 x 1/4"
(Piping port)
0.3 mm2
ø4.1
37.2
(71.7)
0.75 mm2
ø5.9
34.5
(88.5)
19
51-SY-B.qxd 09.3.18 11:11 AM Page 23
Dimensions: 51-SY5000
3-position closed center/exhaust center/pressure center
L-type plug connector (L)
3 18 19
51-SY5 45 40(R)-L-02
9.5
37.2
15.5 48 4 15.5
2 x ø4.3 M5 x 0.8
(For mounting)
4
Insulator: Black (–) (External pilot port)
A B
17.5
17.5
A
B
PE
X
Insulator: Red (+) Manual
EA P EB
35
17 override 17
56
M5 x 0.8 78 44.1 62.5
(Pilot EXH port)
166.2
<For external pilot type>
0.3 mm2
22
9.5
(E-type)
18 18
66.5
28
89.4
0.3 mm2
ø4.1
37.2
84.3
0.75 mm2
ø5.9
34.5
101.1
20
51-SY-B.qxd 09.3.18 11:11 AM Page 24
Series 51-SY5000/7000/9000
Dimensions: 51-SY7000
2-position single
L-type plug connector (L)
21 22.5
03
13.5
51-SY7140(R)-L- 02
79.2
41.7 61 10.4
21.5 2 x ø4.3 M5 x 0.8 21
(For mounting)
4
(External pilot port)
Insulator: Black (–) A B
23
PE
38
46
A
X
Insulator: Red (+) Manual EA P EB
override
21 69 6.4 21.5
123.3 67.2
M5 x 0.8
(Pilot EXH port)
<For external pilot type>
71.2 (E-type)
0.3 mm2
26.5
11.5
13.5
20.5 20.5
5 x 3/8", 1/4"
33
(Piping port)
0.3 mm2
ø4.1
41.7
0.75 mm2
ø5.9
39
21
51-SY-B.qxd 09.3.18 11:11 AM Page 25
Dimensions: 51-SY7000
2-position double 21 22.5
L-type plug connector (L)
13.5
03
51-SY7240(R)-L- 02
41.7 61 4
2 x ø4.3
21.5 21
(For mounting) M5 x 0.8
4
Insulator: Black (–) (External pilot port)
A B
23
23
PE
B
A
X
Insulator: Red (+)
Manual EA P EB
override
38
46
21 69 21.5
79.6 67.2
M5 x 0.8
167.8
(Pilot EXH port)
<For external pilot type>
0.3 mm2
ø1.55
26.5
13.5
11.5
(E-type)
20.5 20.5
71.2
33
0.3 mm2
ø4.1
41.7
(78.8)
0.75 mm2
ø5.9
39
(95.6)
22
51-SY-B.qxd 09.3.18 11:11 AM Page 26
Series 51-SY5000/7000/9000
Dimensions: 51-SY7000
3-position closed center/exhaust center/pressure center
L-type plug connector (L) 21 22.5
13.5
3
51-SY7 40(R)-L-
4
5
02
03
61 4
41.7
2 x ø4.3 M5 x 0.8
21.5 21
(For mounting) (External pilot port)
4
Insulator: Black (–) A B
23
23
PE
B
A
X
Insulator: Red (+)
Manual EA P EB
override
46
38
21 69 21.5
92.6 44.1 67.2
M5 x 0.8 180.8
(Pilot EXH port)
<For external pilot type>
0.3 mm2
26.5
13.5
11.5
(E-type)
20.5 20.5
71.2
33
96.9
0.3 mm2
ø4.1
41.7
91.8
0.75 mm2
ø5.9
39
108.6
23
51-SY-B.qxd 09.3.18 11:11 AM Page 27
Dimensions: 51-SY9000
2-position single
L-type plug connector (L) 29 30
17.5
04
51-SY9140-L- 03
109.3
51.2 86.5 16.8
25 2 x ø5.4 27
(For mounting) 1/8"
5
(External pilot port)
Insulator: Black (–) 4 A 2 B
28.5
PE
47
57
A
B
Insulator: Red (+)
X
5 EA 1 P 3 EB
27 96.5 11.8 25
153.4 76.5
1/8"
(Pilot EXH port)
<For external pilot type>
L (Lead wire length)
0.3 mm2
ø1.55
34.5
15.5
17.5
(E-type)
29.5 29.5
80.5
44.5
0.3 mm2
ø4.1
51.2
0.75 mm2
ø5.9
48.5
24
51-SY-B.qxd 09.3.18 11:11 AM Page 28
Series 51-SY5000/7000/9000
Dimensions: 51-SY9000
2-position double 29 30
17.5
L-type plug connector (L)
04
51-SY9240-L- 03
106
86.5
51.2
25 2 x ø5.4
27
(For mounting) 1/8"
5
(External pilot port)
Insulator: Black (–) 4 A 2 B
28.5
PE
B
Insulator: Red (+)
X
5 EA 1 P 3 EB
47
57
27 96.5 25
194.2 76.5
1/8"
(Pilot EXH port)
<For external pilot type>
L (Lead wire length)
0.3 mm2
ø1.55
34.5
(E-type)
15.5
17.5
29.5 29.5
80.5
44.5
0.3 mm2
ø4.1
51.2
(92)
0.75 mm2
ø5.9
48.5
(108.8)
25
51-SY-B.qxd 09.3.18 11:11 AM Page 29
26
51-SY-B.qxd 09.3.18 11:11 AM Page 30
27
Body Ported Series 51-SY5000/7000
51 SY 5 1 20 A LL 3 01
Explosion-proof
Thread type
Intrinsically safe
51 explosion-proof Nil Rc
structure F G
Series N NPT
5 51-SY5000 T NPTF
7 51-SY7000
A, B port size
Type of actuation Thread piping
1 2-position single Symbol Port size Applicable series
2 2-position double 01 1/8 51-SY5000
3 3-position closed center 02 1/4 51-SY7000
4 3-position exhaust center
One-touch fitting
5 3-position pressure center
Symbol Port size Applicable series
C4 ø4 one-touch fitting
System Note 1) Note 2) C6 ø6 one-touch fitting 51-SY5000
A Z728.H (51-SYE100-A) C8 ø8 one-touch fitting
B MTL728P + (51-SYE100-B) C8 ø8 one-touch fitting
51-SY7000
F KFD0-SD2-Ex1.1065 (51-SYE100-F) C10 ø10 one-touch fitting
Note 1) Attached barrier type Warning If a resin tube is used, take measures
The numbers in ( ), 51-SYE100-쏔 against static electricity.
represents SMC’s control number.
Note 2) If the barrier is not necessary due to
valve replacement etc, enter O after the
system symbol.
Manual override
Example) 51-SY5120-AOLL3-01 Nil Non-locking push type
D Push-turn locking slotted type
E Push-turn locking lever type
Electrical entry
Symbol Electrical entry Lead wire length
Symbol Lead wire length Note
L-type plug connector
3 300 mm —
L 6 600 mm Maximum length 600 mm for L-type
10 1000 mm —
15 1500 mm —
20 2000 mm —
L-type plug connector
with cover 30 3000 mm —
LL 100 10000 mm Semi-standard
Terminal type
TT Note)
28 B
51-SY-B.qxd 09.3.18 11:11 AM Page 32
Series 51-SY5000/7000
Manifold Specifications
Flow-rate Characteristics
29
51-SY-B.qxd 09.3.18 11:11 AM Page 33
Dimensions: 51-SY5000
L-type plug connector (L)
51-SS5Y5-20- Stations -
L1 71 (E-type)
L2 10 59.5
Manual override {1/8"}
16.5
11.5
4 x ø4.5
(Mounting hole)
45.3
EB
EB
B
B
32.7
32.3
30
166.2
21
153.6
60
P
P
21
32.7
16.2
20
EA
EA
A
A
76.8
6 x 1/4"
{P(1), EA(5), EB(3) port}
(Pitch) 1/8"
P = 16 22 {A(4), B(2) port}
(Lead wire length)
n 2 1 Stations
L
67
41.7
36.2
26.5
177
71.7
88.5
Max.10
L (Lead wire length)
41.7
67 39
67
Stations n 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations 9 stations 10 stations 11 stations 12 stations 13 stations 14 stations 15 stations 16 stations 17 stations 18 stations 19 stations 20 stations
L1 60 76 92 108 124 140 156 172 188 204 220 236 252 268 284 300 316 332 348
L2 40 56 72 88 104 120 136 152 168 184 200 216 232 248 264 280 296 312 328
30
51-SY-B.qxd 09.3.18 11:11 AM Page 34
Series 51-SY5000/7000
Dimensions: 51-SY7000
L-type plug connector (L)
51-SS5Y7-20- Stations -
71 (E-type)
L1
67
L2 10
Manual override {1/4"}
4 x ø4.5 16.5
(Mounting 11.5
hole)
52.8
39.4
EB
EB
30
180.8
21
167.8
60
P
P
21
39.8
21 (For mounting)
EA
EA
83.9
6 x 1/4"
(A, B port)
(Pitch) 1/4"
P = 19 23.5 {A(4), B(2) port}
L (Lead wire length)
n 2 1 Stations
67
41.7
38.3
26.5
95.6
71.7
Max.10
L (Lead wire
length)
39
41.7
67
67
Stations n 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations 9 stations 10 stations 11 stations 12 stations 13 stations 14 stations 15 stations 16 stations 17 stations 18 stations 19 stations 20 stations
L1 66 85 104 123 142 161 180 199 218 237 256 275 294 313 332 351 370 389 408
L2 46 65 84 103 122 141 160 179 198 217 236 255 274 293 312 331 350 369 388
31
51-SY-B.qxd 09.3.18 11:11 AM Page 35
Manifold Options
Type 20 Gasket Assembly Part No. Individual SUP Spacer
Blanking Plate Assembly Round head
combination screw
Assembly
t
Gasket
SUP port
Series Assembly part no. Series Gasket assembly
51-SY5000 SY5000-26-20A 51-SY5000 SY5000-GS-1
51-SY7000 SY7000-26-22A 51-SY7000 SY7000-GS-1
Note) Gasket assembly
consists of 10 sets of
mounting screws and a Series Assembly part no. Port size t
gasket. 51-SY5000 SY5000-38-1∗A 1/8 15
51-SY7000 SY7000-38-1∗A 1/4 18
Note) The SUP port of the 51-SY5000/7000
may be either on the lead wire side or
on the end plate side. (An assembly
is shipped under the conditions
Individual EXH Spacer Individual SUP Spacer Assembly shown in the figure.)
Assembly + Individual EXH Spacer Assembly
(Double spacer)
EXH port
(Both sides)
51-SY7000 SY7000-39-1∗A 1/4 18 SUP port Note) The SUP spacer's port does not have an orientation.
As for the EXH ports, adjust the symbol “5” to the pilot
valve side. Also, please make sure to connect the
individual ports to protect the wiring section of the pilot
valve from drainage, etc.
The individual SUP spacer and EXH spacer can be
mounted either on the upper side or lower side. (The
above illustration shows the condition when the
∗ Thread type
product is shipped out from a factory already
Caution assembled.)
Mounting screw Nil Rc
tightening torques F G
M3: 0.8 N· m N NPT
M4: 1.4 N· m T NPTF
Warning
When mounting a valve or spacer on the
manifold base or sub-plate, etc., those
mounting directions are determined. If
mounted in the wrong direction, the equipment
to be connected may cause malfunction. Refer
to external dimensions, and then mount it.
32
51-SY-B.qxd 09.3.18 11:11 AM Page 36
51 SS5Y 5 42 05 02
Explosion-proof
Intrinsically safe Stations
51 explosion-proof 02 2 stations
structure
33
Base Mounted Series 51-SY5000/7000
51 SY 5 2 40 A LL 3
Explosion-proof
Manual override
Intrinsically safe
51 explosion-proof Nil Non-locking push type
structure D Push-turn locking slotted type
Series E Push-turn locking lever type
5 51-SY5000
7 51-SY7000
Lead wire length
Symbol Lead wire length Note
Type of actuation 3 300 mm —
1 2-position single 6 600 mm Maximum length 600 mm for L-type
2 2-position double 10 1000 mm —
3 3-position closed center 15 1500 mm —
4 3-position exhaust center 20 2000 mm —
5 3-position pressure center 30 3000 mm —
100 10000 mm Semi-standard
Pilot type
Nil Internal pilot Electrical entry
R External pilot Symbol Electrical entry
L-type plug connector
34 B
51-SY-B.qxd 09.3.18 11:11 AM Page 38
Series 51-SY5000/7000
Manifold Specifications
Note 1) For 10 stations or more (5 stations or more for the 51-SS5Y7), supply pressure to P port
on both sides and exhaust from EA/EB port on both sides.
Note 2) Refer to “Manifold Options” on page 39.
Flow-rate Characteristics
35
51-SY-B.qxd 09.3.18 11:11 AM Page 39
Dimensions: 51-SY5000
L-type plug connector (L)
51-SS5Y5-41- Stations - L1
5.5 L2 77.5 (E-type)
Manual 13.8
override
4 x ø4.5
(Mounting
113.6
hole) A A A A
20
20
65
66.8
166.2
20
37.8
27.8
B B B B
4.5
6 x 1/4"
8.5
40
52.6
(Pitch)
18 P = 16
Stations 1 2 n
73.5
48.2
42.7
33
23
7.5
9 2n x 1/8"
(Pitch) {A(4), B(2) port}
15.5 P = 16
189.6
113.6
156
51.7
64.3
40
Max.10
L (Lead wire length)
L (Lead wire length)
48.2
45.5
73.5
73.5
Stations n 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations 9 stations 10 stations 11 stations 12 stations 13 stations 14 stations 15 stations 16 stations 17 stations 18 stations 19 stations 20 stations
L1 52.5 68.5 84.5 100.5 116.5 132.5 148.5 164.5 180.5 196.5 212.5 228.5 244.5 260.5 276.5 292.5 308.5 324.5 340.5
L2 42 58 74 90 106 122 138 154 170 186 202 218 234 250 266 282 298 314 330
36
51-SY-B.qxd 09.3.18 11:11 AM Page 40
Series 51-SY5000/7000
Dimensions: 51-SY5000
L-type plug connector (L)
51-SS5Y5-42- Stations - 82.3 (E-type)
length)
(Lead
wire
L
M5 x 0.8
(Pilot EXH port)
Manual override <When using external pilot
solenoid valve>
17.6
109.7
A A A A
24
20
65.4
20
68
156
23.6
20
39
B B B B
29
5.3
6 x 1/4"
33.7
7.3
46.3
M5 x 0.8
(External pilot port)
(Pitch)
21 P = 17.5
5 L2
L1
Stations 1 2 n
47.5
53
37.8
27.3
9.8
8.5 2n x 1/4"
(Pitch) {A(4), B(2) port}
19 P = 17.5
82.3 (E-type)
51-SS5Y5-42- Stations - 51-SS5Y5-42- Stations -
82.3 (E-type) 50.3
53
Max.10
109.7
109.7
189.6
156
F
33.7
50.5
46.3
63.1
Stations n 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations 9stations 10 stations 11 stations 12 stations 13 stations 14 stations 15 stations 16 stations 17 stations 18 stations 19 stations 20 stations
L1 59.5 77 94.5 112 129.5 147 164.5 182 199.5 217 234.5 252 269.5 287 304.5 322 339.5 357 374.5
L2 49.5 67 84.5 102 119.5 137 154.5 172 189.5 207 224.5 242 259.5 277 294.5 312 329.5 347 364.5
37
51-SY-B.qxd 09.3.18 11:11 AM Page 41
Dimensions: 51-SY7000
L-type plug connector (L)
51-SS5Y7-42- Stations - L1
85.5 (E-type)
6 L2
37
length)
(Lead
wire
19.1
L
Manual M5 x 0.8
override (Pilot EXH port)
<When using external pilot
solenoid valve>
4 x ø4.5
(Mounting
125.6
EA
hole) A A A A
PE
26
21
79.6
21
180.8
73
26.6
21
42
EB
31.5
X
B B B B
6 x 1/4"
1.9
11.1
42.2
{P(1), EA(5), EB(3) port}
55.2
M5 x 0.8
(External pilot port)
(Pitch)
21 P = 19
Stations 1 2 n
81.5
56.2
52.8
A A
9.4
41
28.9
B B
7 2n x 1/4"
(Pitch)
24 P = 19 {A(4), B(2) port}
L (Lead wire length)
EA
PE
170.6
P
204.2
P
EB
X
EB
X
37.1
50.1
53.9
66.9
Stations n 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations 9 stations 10 stations 11 stations 12 stations 13 stations 14 stations 15 stations 16 stations 17 stations 18 stations 19 stations 20 stations
L1 61 80 99 118 137 156 175 194 213 232 251 270 289 308 327 346 365 384 403
L2 49 68 87 106 125 144 163 182 201 220 239 258 277 296 315 334 353 372 391
38
51-SY-B.qxd 09.3.18 11:11 AM Page 42
Series 51-SY5000/7000
Manifold Options
Type 41, 42 Gasket Assembly Part No. Individual SUP Spacer
Blanking Plate Assembly Round head Assembly
combination screw
t
Gasket
t
Individual SUP +
Series Individual EXH Port size
EXH port
assembly part no.
51-SY5000 SY5000-75-1∗A 1/8
E
5
1
mounting the port to the pilot valve side,
SUP port please make sure to connect the ports to
51-SY7000 SY7000-39-16∗A 1/4 18
protect the pilot valve wiring section from
drainage.
The individual SUP spacer and EXH
spacer can be mounted either on the
upper side or lower side. (The above
illustration shows the condition when the
product is shipped out from a factory
Mounting screw Nil Rc These are inserted in unused cylinder ports and SUP, EXH ports.
Purchasing order is available in units of 10 pieces.
tightening torques F G
M3: 0.8 N· m N NPT Dimensions
øD
ød
39
51-SY-B.qxd 09.3.18 11:11 AM Page 43
Manifold Options
How to Order Interface Regulator
Series 51-SY5000
ARBY5000-00--2 ARBY5000-M1--2
ARBY5000 00 P 2
Pressure gauge
connection port
00 Pressure gauge (G15-10-01)
M1 Plug (M-5P)
Regulating port
P P port
A1 A port (P controlled, A regulated)
B1 B port (P controlled, B regulated)
Series 51-SY7000
ARBY7000-00--2 ARBY7000-M1--2
ARBY7000 00 P 2
Pressure gauge
connection port
00 Pressure gauge (G15-10-01)
M1 Plug (M-5P)
Regulating port
P P port
A1 A port (P controlled, A regulated)
B1 B port (P controlled, B regulated)
Accessory
Series Round head combination screw Gasket
ARBY5000 M3 x 48.5 (Flat nickel plated) SX5000-57-6
ARBY7000 M4 x 57 (Flat nickel plated) SX7000-57-4
Caution
Mounting screw
tightening torques
M3: 0.8 N·m
M4: 1.4 N·m
40
Series 51-SY
Zener Diode Barrier Dimensions
Terminal No. indication (Non-hazardous side)
51-SYE100-A Terminal No. indication (Hazardous side) Terminal No.8: +
Barrier input: 24 VDC ±10%
Terminal No.1: + Terminal No.7: –
Terminal No.2: –
Terminal for ground (2 parts)
Z728.H
1 2
3 4
5 6
7 8
(M3 Round head combination screw)
12.5
115
Examination certificate emblem
(Examination certificate No. TC14452)
Safe R
Barrier
Safe Area/
1 8
Nicht
Hazardous
>PC<
Ex-Bereich
Area/
Ex-Berelch X3 Unspecified
equipment
2 7 V 250V
Manufacturer: Pepperl+Fuchs
Note) See P+F’s catalog for options.
Caution
Terminal No. 2, No. 7 and the DIN rail mounting bracket on the bottom part of
the barrier or terminal for grounding are short circuit connected.
240 Ω Fuse
1 8
2 7
Zener diode
1
Hazardous
area tmnls
728P+
4
7.5 11.5
3 1
49.2
Haz Safe
4 2
85 14.2
Manufacturer: Measurement Technology
93.5 Ltd.
Examination certificate emblem Note) See MTL Instruments' catalog for
(Examination certificate No. TC14453) options.
A 41
Series 51-SY
Insulating Barrier Dimensions
51-SYE100-F
100
93
Examination
certificate emblem
+ 7
(Examination certificate
1
I
– U
2
3
–
8
No. TC19711)
>PC<
DIN rail mounted part 20
(width: 35 mm)
7 8 9
6
2
5
removable removable
OUT
4
1
Terminal No. indication (Hazardous side) Terminal No. indication (Non-hazardous side)
Terminal: No.1: + Terminal: No.7: +
Barrier input: 24 VDC ±10%
Terminal: No.2: – Terminal: No.8: –
42 B
51-SY-B.qxd 09.3.18 11:11 AM Page 46
Safety Instructions
These safety instructions are intended to prevent hazardous situations and/or equipment damage.
These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or
“Danger.” They are all important notes for safety and must be followed in addition to International
Standards (ISO/IEC)∗1), and other safety regulations.
∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
ISO 4413: Hydraulic fluid power – General rules relating to systems.
IEC 60204-1: Safety of machinery – Electrical equipment of machines. (Part 1: General requirements)
ISO 10218-1: Manipulating industrial robots - Safety.
etc.
Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or
Caution: moderate injury.
Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or
Warning: serious injury.
Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious
Danger : injury.
Warning
1. The compatibility of the product is the responsibility of the person who designs the equipment
or decides its specifications.
Since the product specified here is used under various operating conditions, its compatibility with specific equipment must
be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test
results. The expected performance and safety assurance of the equipment will be the responsibility of the person who
has determined its compatibility with the product. This person should also continuously review all specifications of the
product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment
failure when configuring the equipment.
2. Only personnel with appropriate training should operate machinery and equipment.
The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of
machines or equipment including our products must be performed by an operator who is appropriately trained and
experienced.
3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.
1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling
or runaway of the driven objects have been confirmed.
2. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the
power from any appropriate source is cut, and read and understand the specific product precautions of all relevant
products carefully.
3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of safety measures if the product is to
be used in any of the following conditions.
1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct
sunlight.
2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military,
medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop
circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the
standard specifications described in the product catalog.
3. An application which could have negative effects on people, property, or animals requiring special safety analysis.
4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical
protective function, and periodical checks to confirm proper operation.
Back page 1
51-SY-B.qxd 09.3.18 11:11 AM Page 47
Safety Instructions
Caution
1. The product is provided for use in manufacturing industries.
The product herein described is basically provided for peaceful use in manufacturing industries.
If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract
if necessary.
If anything is unclear, contact your nearest sales branch.
Compliance Requirements
1. The use of SMC products with production equipment for the manufacture of weapons of mass destruction (WMD) or
any other weapon is strictly prohibited.
2. The exports of SMC products or technology from one country to another are governed by the relevant security laws
and regulations of the countries involved in the transaction. Prior to the shipment of a SMC product to another
country, assure that all local rules governing that export are known and followed.
Back page 2
51-SY-B.qxd 09.3.18 11:11 AM Page 48
Series 51-SY5000/7000/9000
Specific Product Precautions 1
Be sure to read before handling.
Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC
Products” (M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.
Warning Caution
Non-locking push type [Standard] The 51-SY series pilot valve and main valve share a common ex-
haust inside the valve. Therefore, do not block the exhaust port
Press in the direction of the arrow.
when arranging the piping.
Series 51-SY5000/7000/9000
Used as a 3-Port Valve
Caution
In case of using a 5-port valve as a 3-port valve
The 51-SY5000/7000/9000 series can be used as normally
closed (N.C.) or normally open (N.O.) 3-port port valves by clos-
Push-turn locking slotted type [Type D] ing one of the cylinder ports (A or B) with a plug. However, they
should be used with the exhaust ports kept open.
While pressing, turn in the direction of the arrow.
If it is not turned, it can be operated the same way as the non- Plug position B port A port
locking type. Type of actuation N.C. N.O.
Plug Plug
Number of solenoids
Plug Plug
LOCK
Double
PUSH
PUSH
Back page 3
51-SY-B.qxd 09.3.18 11:11 AM Page 49
Series 51-SY5000/7000/9000
Specific Product Precautions 2
Be sure to read before handling.
Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC
Products” (M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.
Interface Regulator
Caution
Specifications
Interface regulator model ARBY5000--P-2 ARBY5000-- A1
B1 -2 ARBY7000--P-2 ARBY7000-- A1
B1 -2
5 3 5 3 5 3
75 (EA) (EB) (EA) (EB) (EA) (EB)
50 1 1 1
0.1 0.15 0.2 0.25 (P) (P) (P)
Set pressure (MPa) P port regulated A port regulated B port regulated
(P controlled, (P controlled,
A regulated) B regulated)
ARBY5000 00 P 2 ARBY7000 00 P 2
Regulated port Regulated port
P P port P P port
A1 A port (P controlled, A regulated) A1 A port (P controlled, A regulated)
B1 B port (P controlled, B regulated) B1 B port (P controlled, B regulated)
Back page 4
51-SY-B.qxd 09.3.18 11:11 AM Page 50
Series 51-SY5000/7000/9000
Specific Product Precautions 3
Be sure to read before handling.
Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC
Products” (M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.
Flow-rate Characteristics (Conditions: Inlet pressure 0.7 MPa when 2-position solenoid valve is mounted.)
0.6 0.6
0.5 0.5
0.4 0.4
0.3 0.3
0.2 0.2
0.1 0.1
0 0
0 200 400 600 800 1000 1200 0 200 400 600 800 1000 1200 1400
Back page 5
51-SY-B.qxd 09.3.18 11:11 AM Page 51
Series 51-SY5000/7000/9000
Specific Product Precautions 4
Be sure to read before handling.
Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC
Products” (M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.
Warning Caution
1. Please take antistatic precautions appropriate to the 1. When using other than SMC brand tubing, confirm
use of resin tubing. that the following specifications are satisfied with re-
Refer to “Recommended Practices for Explosion-Protected spect to the outside diameter tolerance of the tub-
Electrical Installations in General Industries” issued by Tech- ing.
nology Institution of Industrial Safety. 1) Nylon tubing within ±0.1 mm
2) Soft nylon tubing within ±0.1 mm
Caution 3) Polyurethane tubing within +0.15 mm,
within –0.2 mm.
The pitch determined for each of the 51-SY series piping ports
Do not use tubing which do not meet these outside diameter
(P, A, B, etc.) is based on the assumption that KJ series one-
tolerances. It may not be possible to connect them, or they
touch fittings will be used.
may cause other trouble, such as air leakage or the tubing
For this reason, other pipe fittings may interfere with each other
pulling out after connection.
depending on their type and size. Dimensions should be con-
firmed in a pipe fitting catalog before they are used.
• Tubing attachment/detachment for one-touch fittings Solenoid Valve Mounting
1) Attaching of tubing
1. Take a tubing having no flaws on its periphery and cut it off
at a right angle. When cutting the tubing, use tubing cutters Caution
TK-1, 2 or 3. Do not use pinchers, nippers or scissors, etc. Mount it so that there is no slippage or deformation in
If cutting is done with tools other than tubing cutters, the gaskets, and tighten with the tightening torque as
tubing may be cut diagonally or become flattened, etc., shown below.
making a secure installation impossible, and causing prob-
lems such as the tubing pulling out after installation or air Model Thread size Tightening torque
leakage. Allow some extra length in the tubing. 51-SY5000 M3 0.8 N·m
2. Grasp the tubing and push it in slowly, inserting it securely 51-SY7000 M4 1.4 N·m
all the way into the fitting. 51-SY9000 M3 0.8 N·m
3. After inserting the tubing, pull on it lightly to confirm that it
will not come out. If it is not installed securely all the way
into the fitting, this can cause problems such as air leakage
or the tubing pulling out.
2) Detaching of tubing
1. Push in the release button sufficiently, pushing its collar
equally around the circumference.
2. Pull out the tubing while holding down the release button so
that it does not come out. If the release button is not
pressed down sufficiently, there will be increased bite on
the tubing and it will become more difficult to pull it out.
3. When the removed tubing is to be used again, cut off the
portion which has been chewed before reusing it. If the
chewed portion of the tubing is used as is, this can cause
trouble such as air leakage or difficulty in removing the tub-
ing.
• The pitch determined for each of the 51-SY series piping ports
(A, B, etc.) is based on the assumption that KJ series one-
touch fittings will be used. For this reason, other pipe fittings
may interfere with each other depending on their type and
size. Dimensions should be confirmed in a pipe fitting catalog
before they are used.
Back page 6
51-SY-B.qxd 09.3.18 11:11 AM Page 52
Series 51-SY5000/7000/9000
Specific Product Precautions 5
Be sure to read before handling.
Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC
Products” (M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.
Warning
The explosion-proof performance of the 51-SY (intrinsically safe explosion-proof system) is ExiaIIBT4 (See the reference “Explosion-
proof Structure Symbol (ExiaIIBT4)”). Selection of a valve for a dangerous place should be done in accordance with “Recommended
Practices for Explosion-Protected Electrical Installations in General Industries” issued by Technology Institution of Industrial Safety.
Warning
This valve should be used in a class-1 or class-2 environment by (Places often falling into the class-2 environment)
combining with a barrier (placed in non-hazardous location). a) A place where dangerous gas or liquid can leak from a con-
tainer if the container is corroded.
Note that this valve can not be used in a class-0 envir-
b) A place where dangerous gas or liquid can be released or leak
onment. out due to incorrect operation of equipment or an abnormal re-
Classification of hazardous environment action of equipment after exposure to high temperature and
high pressure.
Class-0 environment ·········· Not available
c) A place where a dangerous atmosphere is generated due to
A place where an explosive atmosphere is constantly generated
failure of mandatory ventilation equipment and stagnation of
or can be generated.
explosive gas.
Also, a place where atmosphere is above the lower limit of explo-
sion constantly or for a long time of period is also regarded as the d) A place which is indoors around or next to the class-1 environ-
class-0 environment for safety season. ment and rarely has explosive gas with dangerous concentra-
tion.
(Places often falling into the class-0 environment)
a) A container of flammable liquid or space above the liquid level
in the container. Prohibition of Disassembly and Modification
b) Around the liquid level of flammable liquid in an open container
or similar place.
Class-1 environment ·········· Available
Warning
A place where an explosive atmosphere can be generated peri- Disassembling the pilot valve and barrier can deterior-
odically or occasionally. ate the explosion-proof performance, and it may lead to
Also, a place which can have a dangerous concentration of ex- an accident.
plosive gas due to repair, maintenance, or leakage. Therefore, please do not disassemble or modify the pilot valve
(Places often falling into the class-1 environment) and barrier.
a) Around an opening which releases explosive gas due to re-
moval of a product during normal operation, opening/closing of
a lid, or operation of a safety valve. Intrinsically Safe Explosion-proof Circuit Wiring
b) Around the opening of a container such as a tanker and drum
which is filled with flammable liquid. Warning
c) Around an opening which releases explosive gas due to occa-
sional operation of a relief valve.
Wiring of intrinsically safe explosion-proof circuits
d) Around the opening of a gas-vent on a tank etc. should not be routed with the other circuits. Also, it
e) Around an opening which releases explosive gas during in- should not have electrostatic induction or electromag-
spection or repair work. netic induction.
f) A room or a place which can have explosive gas due to insuffi-
cient ventilation.
g) The part which is above the roof of a floating roof tank but
within the shell.
h) A place which can have leaked explosive gas and can accu-
mulate the gas such as a pit.
Class-2 environment ·········· Available
A place where explosive atmosphere can be generated under ab-
normal condition though an explosive atmosphere cannot be
generated under normal condition.
1) A place where flammable gas is constantly operated, but it is
enclosed in an air-tight container or facility, and concentration
of the gas may be thick when the container or facility gets
broken due to an accident or when operation fails.
2) A place that can have a dangerous explosive gas concentra-
tion due to the breakage of mechanical ventilation equipment
though the equipment is usually reliable.
Back page 7
51-SY-B.qxd 09.3.18 11:11 AM Page 53
Series 51-SY5000/7000/9000
Specific Product Precautions 6
Be sure to read before handling.
Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC
Products” (M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.
Reference
Explosion-proof Structure Symbol (ExiaIIBT4)
Symbols Specified by Technical Standard
Ex ia T4
Temperature classification:
Gas of T1 to T4
Group: II
Classification of gas: Gas of A and B
Type of explosion-proof structure: Intrinsically safe
explosion-proof structure (system)
A symbol of the explosion-proof structure based on
Technical Standard (rev.)
Back page 8
51-SY-B.qxd 09.3.18 11:11 AM Page 56
Record of changes
Edition B ∗ Deleted the system “C” and “E” from How to Order on
page 1, 14, 28, 34.
∗ Deleted the 51-SYE100-C from Zener Diode Barrier
Dimensions on page 41.
∗ Deleted the 51-SYE100-E from Insulating Barrier Dimensions
on page 42. NQ
Safety Instructions Be sure to read “Handling Precautions for SMC Products” (M-E03-3) before using.