Gaseous Emission Control by Absorption: Course: Environmental Engineering Module 2: Air Pollution Control

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

Course: Environmental Engineering Module 2: Air Pollution Control

Lecture 8
Gaseous emission control by absorption


 
Course: Environmental Engineering Module 2: Air Pollution Control

 
ABSORPTION
Absorption is a process where transfer of a gaseous component from gas phase to liquid phase
takes place. More specifically in air pollution control, absorption involves the removal of
objectionable gaseous contaminant from a process stream by dissolving them in liquid. Common
terms used in absorption process are as follows:
1. Absorbent: the liquid, usually water, into which contaminant is absorbed
2. Absorbate or solute The gaseous contaminant being absorbed, such as SO2, H2S, etc.
3. Carrier gas: the inert portion of gas stream, usually air, from which the contaminant is to
be removed [1].
4. Interface: the area where the gas phase and the absorbent contact each other.
5. Solubility: the capability of the gas to be dissolved in a liquid.
Absorption equipment used to remove gaseous contaminants are referred to as absorber or wet
scrubber. Wet scrubbers usually cannot be operated to optimize simultaneous removal of both
gases and particulate matter. In designing absorber from gaseous emissions, optimum mass
transfer can be accomplished by:
1. Providing a large interfacial contact area.
2. Providing good mixing between gas and liquid phases.
3. Allowing sufficient residence or contact time between the phases.
4. Ensuring a high degree of solubility of the contaminant in the absorbent [1].

MECHANISM OF ABSORPTION
The gaseous contaminant are removed in absorption process by passing (contacting) a
contaminated laden gas through a liquid. The following three steps occur during this process:
Step1: The pollutant diffuses from bulk area of the gas phases to the gas liquid interface.
Step2: gaseous pollutant transfer across the interface to the liquid phase. This second step
is extremely rapid.
Step3: The pollutant diffuses bulk area of the liquid, making room for additional gas
molecule to absorb.
The rate of mass transfer (absorption) is dependent on the diffusion rate in either the gas phase or
liquid phase. The diffusion rate of gaseous pollutant molecule through a gas is always faster than
its diffusion rate through the liquid because molecules in the gas are further apart than are


 
Course: Environmental Engineering Module 2: Air Pollution Control

 
molecules in the liquid. However the mass transfer rate depends primarily upon the solubility of
the pollutant in the liquid [1].

SOLUBILITY
Solubility of contaminant affects the amount of contaminant that can be adsorbed. It is a function
of both the temperature and, to a lesser extent pressure of a system. As we increase the
temperature of the system the amount of gas that can be absorbed by liquid decreases, while as
with increasing the pressure generally absorption increases. The solubility data are analyzed by
equilibrium diagram [2].
Under certain conditions, Henry’s law may also be used to express equilibrium solubility of gas
liquid system, henry’s is expresses as
p*  Hx (2.8.1)
Where:
p*=partial pressure of solute at equilibrium
x=mole fraction of solute in the liquid
H=Henry’s law constant, pressure/mole fraction
Henry’s law can be rearranged as
y*  mx

Where:
y*=mole fraction in gas phase in equilibrium with liquid.
H=Henry’s law constant, mole fraction in vapour phase/mole fraction in liquid phase
Restriction on Henry’s law:
1. Henry’s law can be used to predict solubility only when the equilibrium line is straight.
2. Henry’s law does not hold good for gases that react or dissociate upon dissolution.

ABSORPTION UNIT
SPRAY TOWER
Spray towers are useful for large volume handling with relatively low pressure drop and
high efficiency. In general smaller the droplet size the greater the turbulence, the more chance
for absorption of the gas. Absorbing liquid usually water is sprayed through the contaminated
gas and the absorbent contaminant solution falls downwards for removal while clean gas exits


 
Course: Environmental Engineering Module 2: Air Pollution Control

 
through an outlet valve in the top of unit. Moisture eliminator reduces the amount of moisture in
the gases being released. Spray tower has less gas liquid interfacial area so they are less effective
in removal of gaseous contaminant.

Figure 2.8.1. Spray Tower


PLATE OR TRAY TOWER
This type of tray contains horizontal trays or plate that provides large gas liquid
interfacial areas. The polluted air is introduced from one side of the bottom of the column, rise
up through the opening in each tray, and the rising gas prevents the liquid from draining through
the opening. Due to repeated contact of gas and liquid the contaminant are removed and the
clean air emerges from the top.
In bubble cap tray column, the contaminated gas moves upward until they strike the cap,
at which point they are diverted downward and discharged as small bubbles from slots at the
bottom of the caps [3]. Since gas continues flow in upward direction so repeated interaction takes
place and contaminated gas is removed and clean gas emerged from the top. The contaminant-
laden liquid flows to the bottom and is drawn off.


 
Course: Environmental Engineering Module 2: Air Pollution Control

Figure 2.8.2. Schematic diagram of bubble cap tray tower


 
Course: Environmental Engineering Module 2: Air Pollution Control

 
PACKED TOWER: In packed tower the contact time between vapour and liquid is increased
by introducing packing. The packing material has a large surface to volume ratio and a large void
ratio that offers minimum resistance to gas flow.
Generally packed tower are operated counter currently, with gas entering at the bottom of
tower and liquid entering from the top. Liquid flows over the surface of the packing in a thin film
causing continuous contact with the gases [4, 5].
Packed towers are highly efficient but they become easily clogged when gas with high
particulate loads are introduced.

Figure 2.8.3. Counter current flow packed tower


REFERENCES
[1] http://www.scribd.com/doc/37001353/81836-03b
[2] http://www.buc.edu.in/sde_book/msc_air.pdf
[3] http://yosemite.epa.gov/oaqps/EOGtrain.nsf/fabbfcfe2fc93dac85256afe00483cc4/f74ae7
4c6531c97d85256b6c006d9c99/$FILE/si412c_lesson11.pdf


 
Course: Environmental Engineering Module 2: Air Pollution Control

 
[4] Spellman, F. R. "Gaseous Emission Control", Environmental Engineer’s Mathematics
Handbook, Taylor & Francis, Inc., 2004.
[5] Mycock, J. C., McKenna, J. D., Theodore, L. “Air pollution control engineering and
technology”, Lewis publishers, Boca Raton, Fla, USA, 1995.


 