FB500 Training
FB500 Training
FB500 Training
JUE-500 training course
Ver.2.0 (Apr,2010)
Contents
FleetBroadband
FB 250 FB 500
Mobile Earth Station
Standard IP communication
Up to 284kbps Up to 432kbps
Best effort type
Streaming IP communication
8, 16, 32, 64, or 128kbps 8,16, 32, 64, 128 or 256kbps
Guaranteed data rates
64kbps (UDI)
ISDN communication
56kbps (RDI)
Fax G3 Fax:3.1 KHz Audio (Time charged) G3 Fax 9.6 kbps : (Time charged)
Voice Email
(3) The Captain (1) Execute Standard
receives a IP connection using
telephone call
from HQ on the
WEB browsing FB
4kbps voice
service (2) You can do Browsing or Email or
Interactive access sharing this connection.
1 FBB system
1.7 Features (Provides an ID to each service)
ID3; 760123452
ID; 770543210
ID; 770543210
1 FBB system
1.8 Features (SIM card is essential)
For the communication, SIM card provided from your Distribution
Partner (DP) is required.
DP; Stratos, Vizada, KDDI, MVS, etc.
1.9 Features (LaunchPad)
Simple operation is available by dedicated operating software
”LaunchPad”
Main Unit
LAN cable
(straight)
PC
1 FBB system
1.10 Emergency call (505 call)
Inmarsat has introduced 505 emergency call for FBB.
This is NOT GMDSS comliant.
x 3 pcs
x 1 pc
2. Equipment overview
PC
(user supply)
Main Unit
Telephone
(option) Coaxial cable
AC power source
(option)
FAX
(option)
3. FB500 basic configuration (standard)
PC
(User supply)
Main Unit
JRC NQA-2217
Coaxial cable
Telephone OIU
ON
(Option) Ethernet 1 2 3
4
POWER
OFF
OIU
AC power supply
FAX
(Option)
4. Equipment specification
LNA RFU
Transmitter
Duplexer
Cable
Antenna Low Noise Amp. Receiver
I/F
Tracking Power
Receiver supply
Sensor circuit
Rotary Joint
GPS Antenna
GPS module
ACU
4. Equipment specification
ADE
Interface part ADE
Core module (CM)
(Manufactured by HNS)
OIU
OIU
Interface part
DC+24V
4. Equipment specification
4.6 Environmental condition
Inmarsat specification
IEC60945
4.7 Primary power
DC +24V (-20% to +30%)
4.8 Consumption
Less than 4.0A at DC24V, including OIU.
4. Equipment specification
4.9 External Interface
4.9.1 Main Unit connector
Connection port Connector type Max. cable length Remarks
4.9 External interface
4.9.2 OIU connector (terminal block)
Connection port Connector type position Max. cable length Remarks
GPS input Terminal block Back Using when inner GPS is failure
4.10 Interface restrictions
1) Telephone connection: 2 phones max (minimum configuration)
without Handset
Handset
TEL1/TEL2
ON
Ethernet 1 2 3 4 POWER OFF
Handset
TEL1/TEL2
4. Equipment specification
4.10 Interface restrictions
3) FAX connection: Same as telephone.
・ ・
JRC NQA-2217 OIU
・
ON
Ethernet 1 2 3 4 POWER OFF
Handset 1 1 No
Analogue telephone port Analogue 2- wire telephone port 6(Max.) *1 2 (Max.) 6 (Max.)
LAN port 4(Max.) *1 1 1
USB port 1 1 No
ISDN port 1 1 1
External buzzer Buzzer for informing a call arriving 4(Max.) *1 No 10(Max.)
Sending distress call via Not Not
Voice distress button 6(Max.)
telephone line available available
External call button 【TBD】 2(Max) *1 No No
Wideband RF 1 1 1
GYRO input GYRO connection Yes*2 Yes *3 Required
Inputting position data from
External GPS input Yes*1 No Standard
external GPS
Outputting position data to an
GPS external output Yes*1 No No
external device
4. Equipment specification
Card reader Reading a credit card Not available Not available 6(Max.)
Display Simple operation terminal 1 Handset 1 Handset 1 Panel LCD
Memorizing the dial numbers of Standard Standard Standard
Speed Dialing
telephone or FAX (99 dials) (99 dials) (99 dials)
Memorizing the last dialed
Re-dialing Standard Standard Standard
number
Specifying the phone to make Specifying the telephone which is
Standard No Standard
a call (Call request) able to originating a call
Call reception setting Set the ringing timing. Standard - -
Specifying the phone to Specifying the telephone which is Included
No Standard
receive a call (Call reception) able to receiving a call above
Ringing the other phone when
Absentee transfer the specified phone is not taken No No Standard
for the defined time.
Memorize the call logging history
Call logging Standard Standard Standard
and display.
Prohibit the originating call by a
Request lock Standard Standard Standard
secret code
Automatic
Standard Standard Standard
disconnection
Not Not
Alarm output Alarm information output to VDR (Via LAN) Yes *1
available available
Handset screen
Data comm.
Setting
LaunchPad screen
5. Installation
5.1 Parts List [Option]
Telephone; NQW-132B
Minimum configration
ADE; GSC-501
FAX; FAX-2820
External buzzer;
Co-ax cable;
Standard configration
CFQ-3922A15,A2,A25
Co-ax cable;
CFQ-3922A3,A35,A40,A45
CFQ-3922A5 (50m) CFQ-3923A7,CFQ-3923A1
Name;Hoisting rope
Type;MPXP34646
Code;MPXP34646
Relay cable;
H-7ZCSC0212
(50cm)
BDE;
TNC connector
5. Installation
5.3 BDE(minimum configuration)
ISDN devices
24V DC
Main Unit
ADE
~
~
Handset
PC
Analogue telephone
FAX
5. Installation
5.4 BDE(Standard configuration)
5. Installation
5.4 BDE(standard configuration)
a) Coax relay
cable
b)Signal cable
c)LAN cable
d)Power
cable
a),b),c)
Attached to OIU
d) Standard
component
5. Installation
5.4 BDE(standard configuration)
ISDN devices
Analogue telephone
(Max4)
Handset
Buzzer (Max4)
ADE
Main Unit
~
~
PCs
FAX Analogue telephone
5. Installation
5.5 Handset extension cable
5m
5. Installation
5.6 GYRO connection
OIU OIU
6.3 OIU
The units for replacement (repair parts) are:
OIB (Option Interface Board) CDJ-2410
TB (Terminal Board) CQD-2181
(Ref.) Comparison of F33 and FB250
Data 9.6 kbps : Spot beam area Data 3.1 KHz Audio higher than EL20
Data
(Time Charged) degrees area (Time Charged)
Voice x 3, Fax x 2, Data x 1,
ID Voice x 1, 3.1 KHz Audio x 1
MPDS x1
SMS No Support Max 160 characters
(Ref.) Fleet system coverage area