LF-4000 Series: Conventional Fire Alarm Control Unit

Download as pdf or txt
Download as pdf or txt
You are on page 1of 43

LF-4000 Series

Conventional Fire Alarm Control Unit

Features:
• 1 to 36 Zone Control Panels
• Control Key Switch
• Easy Push Button Control Switches
• Zone Circuit Monitoring for Open and Short
• Sounder Circuit Monitoring for Open and Short
• Multiple Indicator LED’s for Quick Identification
• Up to 30 Detectors per Zone
• 2 Wire System
• Individual Zone Relays
• No Polarity for Zone Inputs
• Polarized for Sounder Circuits
• Auxiliary 24VDC Power
• Fuse Protection for AC Main, Battery and Aux Power
• Circuit Protection for Zone and Sounder Circuits
• Top and Bottom Knockouts for Easy Installation
• Rigid Enclosure

Description:
The LF-4000 Series Conventional Fire Alarm Control common alarm relay, configurable zone relays, and a
Panels are manufactured based on advanced technology 24VDC auxiliary output. All of which ensures the system
while maintaining high quality during assembly. It is of can be easily configured to meet the requirements of the
solid state circuitry and is designed and tested to meet end-user.
the requirements of industrial or commercial
applications. With its multi-zone architecture (see It also has the provision to connect repeater panels. The
ordering information), the system can be installed repeaters are integrated into the system utilizing a serial
ranging from small buildings to large constructions. data line and a 24VDC power source. Up to 8 repeaters
can be connected to a single system.
Up to 30 devices, combination of smoke, heat and
manual call points, can be connected to a single zone. For security purposes, the Control Panel is fitted with a
Zone wiring are non-polarized which makes installation control key switch which locks all the push-button
easier and fault free. Any alarm coming from a zone functions so only authorized personnel would be
would activate the sounder circuits, common alarm relay, allowed to operate the system. The provided push-
zone relay and the panel audible circuit. Once the panel button keys allows the operator to Silence the local panel
has been silenced and a subsequent alarm occurs in and alarm indicators during a fire or trouble condition, to
another zone, the internal speaker and sounder circuits Evacuate by operating all sounders and to perform a
would then re-activate with its associated zone relay. The local lamp test and Reset the control unit.
system incorporates 2 built-in sounder circuits, a

Lichfield Fire & Safety Equipment Co. Ltd Tel: +44 (0) 870 066 44 01
Saturn Centre, 2nd floor, Suite 4, Spring Road, Fax: +44 (0) 870 066 44 02
Ettingshall, Wolverhampton WV4 6JX, United Kingdom. email: info@lifeco-uk.com
Wiring and Terminal Details:

Lichfield Fire & Safety Equipment Co. Ltd Tel: +44 (0) 870 066 44 01
Saturn Centre, 2nd floor, Suite 4, Spring Road, Fax: +44 (0) 870 066 44 02
Ettingshall, Wolverhampton WV4 6JX, United Kingdom. email: info@lifeco-uk.com
LF-4000 Series Conventional Fire Alarm Control Unit

Flat Ribbon Cable Connection:

Repeater Panel Termination:

Lichfield Fire & Safety Equipment Co. Ltd Tel: +44 (0) 870 066 44 01
Saturn Centre, 2nd floor, Suite 4, Spring Road, Fax: +44 (0) 870 066 44 02
Ettingshall, Wolverhampton WV4 6JX, United Kingdom. email: info@lifeco-uk.com
Installation and Dimentional Details:
1, 2, & 4 ZONE 24 & 28 ZONE
300 90 214 308 120 214
30 50 30 3010 50 30

20
20

R3
R3
SYSTEM COMMON ZONE 1 ZONE 2 ZONE 3 ZONE 4

R5
SYSTEM COMMON ZONE 1 ZONE 2 ZONE 3 ZONE 4

8
R5
FIRE FIRE FIRE FIRE FIRE FIRE

8
FIRE ALARM

20
FIRE ALARM FIRE FIRE FIRE FIRE FIRE FIRE
20

CONTROL PANEL
90

CHARGER FAULT SOUNDER O/C O/C FAULT O/C FAULT O/C FAULT O/C FAULT
CONTROL PANEL CHARGER FAULT SOUNDER O/C O/C FAULT O /C FAULT O/C FAULT O/C FAULT

BATTERY FAULT SOUNDER S/C S/C FAULT S/C FAULT S/C FAULT S/C FAULT
BATTERY FAULT SOUNDER S/C S/C FAULT S/C FAULT S/C FAULT S/C FAULT
230

WITH
WITH REPEATER PROVISION
REPEATER PROVISION RESET SILENCE EVACUATE ON
RESET SILENCE EVACUATE ON

235
WARNING! OFF
WARNING! OFF LIVE PARTS INSIDE
LIVE PARTS INSIDE
PRESS TO PRESS TO SILENCE PRESS TO CONTROL
PRESS TO PRESS TO SILENCE PRESS TO TEST LEDS ALARMS/TONE SOUND ALARMS
CONTROL
TEST LEDS ALARMS/TONE SOUND ALARMS

ZONE 5 ZONE 6 ZONE 7 ZONE 8 ZONE 9 ZONE 10 ZONE 11 ZONE 12


FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE
O/C FAULT O/C FAULT O/C F AULT O/C FAULT O/C FAULT O/C FAULT O/C FAULT O/C FAULT

S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT

520
40
22

ZONE 13 ZONE 14 ZONE 15 ZONE 16 ZONE 17 ZONE 18 ZONE 19 ZONE 20


6

FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE


45

50

O/C FAULT O/C FAULT O/C F AULT O/C FAULT O/C FAULT O/C FAULT O/C FAULT O/C FAULT

S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT

2-
Ø2
2
260 ZONE 21 ZONE 22 ZONE 23 ZONE 24 ZONE 25 ZONE 26 ZONE 27 ZONE 28
FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE
O/C FAULT O/C FAULT O/C F AULT O/C FAULT O/C FAULT O/C FAULT O/C FAULT O/C FAULT

S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT

8 & 12 ZONE 40

22
300 100 214 -Ø Ø2
2
60

6 2-
3010 50 30
20

R3

60
20

SYSTEM COMMON ZONE 1 ZONE 2 ZONE 3 ZONE 4


R5
8

FIRE ALARM FIRE FIRE FIRE FIRE FIRE FIRE


CONTROL PANEL CHARGER FAULT SOUNDER O/C O/C FAULT O /C FAULT O/C FAULT O/C FAULT

BATTERY FAULT SOUNDER S/C S/C FAULT S/C FAULT S/C FAULT S/C FAULT
260
130

WITH
REPEATER PROVISION
RESET SILENCE EVACUATE ON

WARNING! OFF
LIVE PARTS INSIDE
310

PRESS TO PRESS TO SILENCE PRESS TO CONTROL


TEST LEDS ALARMS/TONE SOUND ALARMS

ZONE 5 ZONE 6 ZONE 7 ZONE 8 ZONE 9 ZONE 10 ZONE 11 ZONE 12


FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE
O/C FAULT O/C FAULT O/C FAULT O/C FAULT O/C FAULT O /C FAULT O/C FAULT O/C FAULT

S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT

32 & 36 ZONE
40 214
6- 308 120
Ø2 3010 50 30
20

2
R3
45

50
100

2-
Ø2
SYSTEM COMMON ZONE 1 ZONE 2 ZONE 3 ZONE 4

R5
8
FIRE ALARM FIRE FIRE FIRE FIRE FIRE FIRE

2
20

CONTROL PANEL CHARGER FAULT SOUNDER O/C O/C FAULT O/C FAULT O/C FAULT O/C FAULT

BATTERY FAULT SOUNDER S/C S/C FAULT S/C FAULT S/C FAULT S/C FAULT

260 WITH
REPEATER PROVISION
RESET SILENCE EVACUATE ON

WARNING! OFF
LIVE PARTS INSIDE

PRESS TO PRESS TO SILENCE PRESS TO CONTROL


TEST LEDS ALARMS/TONE SOUND ALARMS
285

ZONE 5 ZONE 6 ZONE 7 ZONE 8 ZONE 9 ZONE 10 ZONE 11 ZONE 12


FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE
O/C FAULT O/C FAULT O/C F AULT O/C FAULT O/C FAULT O/C FAULT O/C FAULT O/C FAULT

S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT

16 & 20 ZONE
ZONE 13 ZONE 14 ZONE 15 ZONE 16 ZONE 17 ZONE 18 ZONE 19 ZONE 20
620

FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE

300 110 214 O/C FAULT

S/C FAULT
O/C FAULT

S/C FAULT
O/C F AULT

S/C FAULT
O/C FAULT

S/C FAULT
O/C FAULT

S/C FAULT
O/C FAULT

S/C FAULT
O/C FAULT

S/C FAULT
O/C FAULT

S/C FAULT

3010 50 30
20

R3

ZONE 21 ZONE 22 ZONE 23 ZONE 24 ZONE 25 ZONE 26 ZONE 27 ZONE 28


SYSTEM COMMON ZONE 1 ZONE 2 ZONE 3 ZONE 4
R5

FIRE
8

FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE
FIRE ALARM
20

O/C FAULT O/C FAULT O/C F AULT O/C FAULT O/C FAULT O/C FAULT O/C FAULT O/C FAULT
CONTROL PANEL CHARGER FAULT SOUNDER O/C O/C FAULT O /C FAULT O/C FAULT O/C FAULT

S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT
BATTERY FAULT SOUNDER S/C S/C FAULT S/C FAULT S/C FAULT S/C FAULT
182.5

WITH
REPEATER PROVISION
RESET SILENCE EVACUATE ON

WARNING! OFF
LIVE PARTS INSIDE

PRESS TO PRESS TO SILENCE PRESS TO CONTROL


TEST LEDS ALARMS/TONE SOUND ALARMS

ZONE 29 ZONE 30 ZONE 31 ZONE 32 ZONE 33 ZONE 34 ZONE 35 ZONE 36


FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE
O/C FAULT O/C FAULT O/C F AULT O/C FAULT O/C FAULT O/C FAULT O/C FAULT O/C FAULT

S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT

ZONE 5 ZONE 6 ZONE 7 ZONE 8 ZONE 9 ZONE 10 ZONE 11 ZONE 12


415

FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE


O/C FAULT O/C FAULT O/C FAULT O/C FAULT O/C FAULT O /C FAULT O/C FAULT O/C FAULT

S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT

ZONE 13 ZONE 14 ZONE 15 ZONE 16 ZONE 17 ZONE 18 ZONE 19 ZONE 20 40


FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE

22
O/C FAULT O/C FAULT O/C FAULT O/C FAULT O/C FAULT O /C FAULT O/C FAULT O/C FAULT

S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT S/C FAULT

-Ø Ø2
2
60

6 2-
60

40
22 260

6
45

50

2-
Ø2
2

260

Note: All dimensions are in millimeters

Lichfield Fire & Safety Equipment Co. Ltd Tel: +44 (0) 870 066 44 01
Saturn Centre, 2nd floor, Suite 4, Spring Road, Fax: +44 (0) 870 066 44 02
Ettingshall, Wolverhampton WV4 6JX, United Kingdom. email: info@lifeco-uk.com
LF-4000 Series Conventional Fire Alarm Control Unit

Fusing Rating:
Mains Fuse 0.5A (5X20mm)
Zone 1 to Zone 4 Control Panel Battery Fuse 3.0A (5X20mm)
Output Fuse 3.0A (5X20mm)
Mains Fuse 0.75A (5X20mm)
Zone 5 to Zone 8 Control Panel Battery Fuse 4.0A (5X20mm)
Output Fuse 4.0A (5X20mm)
Mains Fuse 0.75A (5X20mm)
Zone 9 to Zone 12 Control Panel Battery Fuse 4.0A (5X20mm)
Output Fuse 4.0A (5X20mm)
Mains Fuse 0.75A (5X20mm)
Zone 13 to Zone 16 Control Panel Battery Fuse 7.0A (5X20mm)
Output Fuse 7.0A (5X20mm)
Mains Fuse 0.75A (5X20mm)
Zone 17 to Zone 20 Control Panel Battery Fuse 7.0A (5X20mm)
Output Fuse 7.0A (5X20mm)
Mains Fuse 1.0A (5X20mm)
Zone 21 to Zone 36 Control Panel Battery Fuse 10.0A (5X20mm)
Output Fuse 10.0A (5X20mm)

ORDERING INFORMATION
Model No. Description Dimensions (mm)
LF-4000/1 1 Zone Fire Alarm Control Panel 230 x 300 x 90
LF-4000/2 2 Zone Fire Alarm Control Panel 230 x 300 x 90
LF-4000/4 4 Zone Fire Alarm Control Panel 230 x 300 x 90
LF-4000/8 8 Zone Fire Alarm Control Panel 310 x 300 x 100
LF-4000/12 12 Zone Fire Alarm Control Panel 310 x 300 x 100
LF-4000/16 16 Zone Fire Alarm Control Panel 415 x 300 x 110
LF-4000/20 20 Zone Fire Alarm Control Panel 415 x 300 x 110
LF-4000/24 24 Zone Fire Alarm Control Panel 520 x 308 x 120
LF-4000/28 28 Zone Fire Alarm Control Panel 520 x 308 x 120
LF-4000/32 32 Zone Fire Alarm Control Panel 620 x 308 x 120
LF-4000/36 36 Zone Fire Alarm Control Panel 620 x 308 x 120

LF-4050/16 1 to 16 Zone Repeater Panel 120 x 160 x 32.5


LF-4050/36 20 to 36 Zone Repeater Panel 180 x 160 x 32.5

Lichfield Fire & Safety Equipment Co. Ltd Tel: +44 (0) 870 066 44 01
Saturn Centre, 2nd floor, Suite 4, Spring Road, Fax: +44 (0) 870 066 44 02
Ettingshall, Wolverhampton WV4 6JX, United Kingdom. email: info@lifeco-uk.com
TECHNICAL SPECIFICATION:
Power Requirement 220 VAC 50/60 Hz ± 10%
Sounder Circuit
Output Voltage 24 VDC
Alarm Current 1, 2, 4, 8 Zone 700 mA,
12, 16 Zone 1A
20, 24 Zone 1.5A
28, 32, 36 Zone 2A
EOL 5.6K
Zone Circuit
Voltage 24 VDC
Supervisory Current 4 mA
EOL 5.6K
Loop & Sounder Circuit Protection Thermal Circuit Cut-off
Auxiliary Relays
Contact Rating 125 VDC, 12A
250 VAC, 7A
28 VDC, 7A
Auxiliary Power 24 VDC, 1A
Repeater Up to 8 panel

Distributor:

Lichfield Fire & Safety Equipment Co. Ltd


Saturn Centre, 2nd floor, Suite 4, Spring Road,
Ettingshall, Wolverhampton WV4 6JX, United Kingdom.
Tel: +44 (0) 870 066 44 01, Fax: +44 (0) 870 066 44 02
email: info@lifeco-uk.com, Website: www.lifeco-uk.com
LF PE HD/2000
Combined Smoke and Heat Detector

Features:

• Low Profile Design


• Low Power Consumption
• High Precision and Stability
• Quick Fire Alarm Transfer Speed
• High Accuracy of Fire Detection
• Special Chamber Design
• Polarized Wiring
• Ease of Maintenance
• Base options for Supplementary Relay and/or
Remote Indicator
• 2-Wire, 3-Wire and 4-Wire Applications
• LED indicator

Description:

The LF PE HD 2000 Combined Smoke and Heat Before the fire break out, internal
Detector was designed on theory in which the temperature would become higher than the
light emits diffusively to various directions when usual standard. When it reaches the
reflecting onto the smoke chamber. programmed temperature level, the sensor
will transfer signal to the control panel to
It uses specialized smoked chamber design, convert the L-C into short signal. At this
which could sense the presence of smoke moment, the highly reliable LED indicator will
particles produced by fast combustion or slow light up for notification.
smoldering fire. Combining fire algorithms
stored in its memory with the special three part The detector’s design widely applies to all
design of the smoke chamber and given the kinds of industrial and commercial
photo-sensor’s viewing angle, the detector can constructions with its high resistance to
effectively sense both white smoke and black humidity, wide operating temperature
smoke with virtually no false alarms. range, high reliability and ease of installation
and configuration.
Dimension and Installation Details:

106mm 4x4 Box

L2
S1

L1 Base

C1
S2

C2
Screws

65mm

85mm

106mm
52mm
36mm

16mm

Wiring:

(+)
ZONE

L2 L1 V+ L2 L1 V+
TO THE
S2
S2
S1

S1

CONTROL EOL RESISTOR


PANEL C1 C2 LED C1 C2 LED

-R -R

GND
(-)
TECHNICAL SPECIFICATION:
Effective Warning Area Height above the ground Below 4m 4 ~ 8m 8 ~ 15m
(Smoke) Building 100 m2 50 m2 30 m2
Effective Warning Area Height above the ground Below 4m 4 ~ 8m
(Heat) Building 20 m2 15 m2
Input Voltage Range 16V ~ 32VDC (DC 24V)
Alarm Current 10 ~ 100mA (MAX)
Standby Current 60µA/24VDC
Set Temperature 57˚C
Relative Humidity 0 ~ 95%RH
Weight 187g
Diameter 106mm
Height 52mm
Material ABS Plastic
Color White
LF-AV-4125
Conventional Audible and Visual Alarm Indicator

Features:
• Quick Response Time
• Piezoelectric Horn
• High Intensity Strobe
• Integrated Electronics
• High Performance at Low Cost
• 3 User Selectable Tones via jumpers
• Wall Mount Type
• Two Wire Operation

Description:
The LF-AV-4125 Conventional Audible and Visual Alarm Selector jumpers are also provided at the back of the unit
Indicator adopts a built-in integrated circuit, a for a variety of tone outputs. Depending on the
piezoelectric sounder and a high intensity strobe which requirement of the authority having jurisdiction, the
when combined, produces a high energy conversion device can be set to have an audible output of Hi-Lo,
efficiency for effective output of light and sound while Wailor Siren.
utilizing a minimum amount of power.
The indicator’s design widely applies to all kinds of
The LF-AV-4125 can be mounted by opening the front industrial and commercial constructions with its high
cover and installing the body of the device to a standard resistance to humidity, wide operating temperature
3 inch square box. The mounting holes are hidden when range, high reliability and ease of installation and
the cover is replaced. Together with the modern style of configuration.
the strobe unit and the contour of the device, makes it
appealing with any building wall design.

Lichfield Fire & Safety Equipment Co. Ltd Tel: +44 (0) 870 066 44 01
Saturn Centre, 2nd floor, Suite 4, Spring Road, Fax: +44 (0) 870 066 44 02
Ettingshall, Wolverhampton WV4 6JX, United Kingdom. email: info@lifeco-uk.com
Physical Dimensions:

Installation:

Note: All dimensions are in millimeters

Lichfield Fire & Safety Equipment Co. Ltd Tel: +44 (0) 870 066 44 01
Saturn Centre, 2nd floor, Suite 4, Spring Road, Fax: +44 (0) 870 066 44 02
Ettingshall, Wolverhampton WV4 6JX, United Kingdom. email: info@lifeco-uk.com
LF-AV-4125 Conventional Audible and Visual Alarm Indicator

TECHNICAL SPECIFICATION:
Operating Temperature -10ºC ~ 55ºC
Relative Humidity 95% non-condensing
Wiring System Polarized
Flash Intensity 1.2 Watts
Flash Cycle Every 1.5 seconds
Sound Output 105 dB
Device Operating Voltage 22 ~ 26 VDC
Auxiliary Power Consumption 120 mA
Weight 260g
Dimensions (mm) 160 x 127 x 53mm

Wiring and Terminal Details:


• Observe proper polarity when connecting
tosounder circuit
• User Selectable Tones:

(a) (b) (c) (d)

Wail Hi-Lo Siren Close

(a) (b) (c) (d)


(a) (b) (c) (d)

Wail Hi-Lo Siren Close

Wail Hi-Lo Siren Close

Lichfield Fire & Safety Equipment Co. Ltd Tel: +44 (0) 870 066 44 01
Saturn Centre, 2nd floor, Suite 4, Spring Road, Fax: +44 (0) 870 066 44 02
Ettingshall, Wolverhampton WV4 6JX, United Kingdom. email: info@lifeco-uk.com
Distributor:

Lichfield Fire & Safety Equipment Co. Ltd


Saturn Centre, 2nd floor, Suite 4, Spring Road,
Ettingshall, Wolverhampton WV4 6JX, United Kingdom.
Tel: +44 (0) 870 066 44 01, Fax: +44 (0) 870 066 44 02
email: info@lifeco-uk.com, Website: www.lifeco-uk.com
LFB6/8 & LFBW6/8
Fire Alarm Bell

Features:

• UL Approved
• Quick and Easy Installation
• Vibrating Type
• High Sound Level
• High Reliability
• Low Power Consumption
• Available in 6”, 8” Housing
• Mounts to Standard 4” Square Electrical Box
• Cast Alloy Housing
• Indoor or Outdoor* Use

Description:

LIFECO LFB series bells are intended for fire detection control panels and requires a
alarm application only. The gong is of cast voltage of 24VDC in order to operate.
alloy metal suitable to produce loud and
standard alarm bell sound. Two gong sizes This design of exceptional structure is sturdy
are available to suit high or low noise level and durable. It is also weather proof that can
applications. be used as an indoor or outdoor fire alarm
bell. When used outdoors, weather proof
It produces a characteristic sound with a back box is also required. Each bell is
96dBA @ 10Ft. for 6” bell and 98dBA @ 10Ft. supplied with a mounting plate to fix it on a
for 8” bell sound level. The external casing is standard utility box or to install directly on the
painted red. It can be connected to all fire wall.
Wiring Diagram:

Red (IN) Red (OUT)

From Control Panel or To Next Bell or


Preceding Bell End-of-Line Resistor

Black (IN) Black (OUT)

Installation Details:

4" SQUARE OUTLET BOX


(SUPPLIED BY OTHERS)

ADAPTOR PLATE
STRIKER (27-401)

HEX BOLT GONG


ORDERING INFORMATION:
MODEL SIZE VOLTAGE DC CURRENT dBA @ 10 Ft. APPLICATION
LFB 6 6" 24 V DC 100mA 96 Indoor
LFB 8 8" 24 V DC 100mA 98 Indoor
LFB 6W 6" 24 V DC 100mA 96 Outdoor*
LFB 8W 8" 24 V DC 100mA 98 Outdoor*

* Weather proof back box available on request.


LF/B 10
Call Point Series

Features:

• Arabic and English Label


• Quick Fire Alarm Transfer
• Easy Operation – Push to Activate
• No Polarity
• Ergonometric Construction
• Durable Design
• High Performance at Low Cost
• Easy to install
• Semi flush or Surface Mounting
• With protective cover
• Suitable for indoor use

cover

Description:

The LF-B 10 Call Point Series satisfies the of the glass. When the glass is broken, the
requirements for a manual fire alarm switch is released and causes an alarm signal
initiating device. With its sleek and durable to be sent to the fire alarm control panel
design, it is easily observed yet does not through the initiating device circuit.
hinder with building design and can be fitted
along corridors, hallways and exits for easy The detector’s design widely applies to all
access to operate in cases where there is a kinds of industrial and commercial
requirement for activating an alarm signal. constructions with its high resistance to
humidity, wide operating temperature
The switch inside is kept pressed by the edge range, high reliability and ease of installation.
Wiring Diagram:

470 470

1 2 3 1 2 3

Installation Details:

Mounting Base

Screw

Glass
Cover

Key
Testing:

When the key is inserted, the glass drops


and tests the switch. Do not leave the key
with the Call Point after commissioning.

Dimensional Details:

87mm 52mm

FIRE

87mm 87mm

TECHNICAL SPECIFICATION:
Terminals Screw type to suit 0.28mm2 to 2.5mm2 Cables
Contact Rating Resistive 1A @ 50 VAC/VDC
Maximum Contact Resistance 150 mΩ
Minimum Contact Voltage 12V AC/DC
Operating Temperature -40˚C ~+85˚C
Material ABS Plastic
Dimensions 87 x 87 x 52 mm
Color Red
LF/EX
Fire Alarm & Gas Extinguishing Control Panel

Features:

• Rigid Steel Powder Coated Cabinet


• Built-in Battery and Internal Charger
• System Status Indication
• Indicators for Charge Fault & Battery Fault
• Monitored Alarm Circuits for Both Open and
Short Circuit
• Manual Operating Switch on Front Fascia
• 2 Monitored Detection on Zones
• Monitored Gas Release
• Knockouts on top and bottom sides for Easy
Installation
• Relay Contacts
• Control Key Switch
• Release Timer
• Silence/tone and/or First Tone Alarm
• Automatic or Manual Operation
• Reset/LED Test Button

Description:

The LF/EX Fire Alarm and Gas extinguishing The LF/EX is interfaced with two detection zones
Control Panel is manufactured based on of a conventional fire alarm panel which are
advanced technology while maintaining utilized to provide double knock (coincidence)
high quality during assembly. It is of solid detection throughout the gas protected area.
state circuitry and is designed and tested to
meet the requirements of industrial or A callpoint situated on the front of the unit can
commercial applications. be operated to manually release the
extinguishant. It has multi-colored LED indicators
It provides operator interactive control of the for easy reference of fault isolation.
fire alarm and gas extinguishing system.
For security purposes, the Control Panel is fitted
Push buttons are provided on the front fascia with a control key switch which locks all the
for manual/automatic modes of extinguisher push-button functions so only authorized
operation, first stage alarm, silence and personnel would be allowed to operate the
reset. system.
Control Panel Connection Diagram:

SOUNDER 1 FUSE
RIBBON
CONNECTOR TO
DISPLAY BOARD
SOUNDER 2 FUSE

BOTTLE O/P FUSE

BATTERY &
CHARGER FUSE
CIRCUIT FUSE

Dimensions of Box and Installation Holes:


TECHNICAL SPECIFICATION:
Mains Voltage 230VAC @ 50/60 Hz +15%, -10%
Charger Voltage 25~30VDC (Set Internally to 27.6V)
Battery Voltage 24 V SLA (2x12V)
Battery Space 7.0 AH Maximum
Mains Supply Protection 1.5 AF 20x5mm Glass Fuse
Battery and Charger Voltage Protection 1.5 AF 20x5mm Glass Fuse
Reverse Battery Protection Battery Fuse
Sounder Output (1st and 2nd Stage) 24 VDC Nominal
Sounder Output Protection 500mAF 20x5mm Glass Fuse
Auxiliary Supply Output 24 VDC Nominal
Auxiliary Supply Protection 500mAF 20x5mm Glass Fuse
Auxiliary Relay Contacts (1st and 2nd
30V AC/DC 1.0 A Each
Stage)
Bottle Output 24 VDC Nominal
Bottle Output Protection 500mAF 20x5mm Glass Fuse
Zone Voltage 24 VDC
Quiescent Zone Current 8mA per Circuit
Max Zone Circuit Resistance 50 Ω
Max Sounder Circuit Resistance 25 Ω
Max Resistance - Other Circuits 50 Ω
Quiescent Battery Current (Tone Muted) 100mA Nominal
Quiescent Battery Current (Tone Not
125mA Nominal
Muted)
Max Total Load Current (Snd, Bottle and
1.5A (Although each maybe to fuse rating)
Aux+VE)
Bottle Output, 1st and 2nd Stage Snd
Circuits Monitored for O/C and S/C
Outputs, Zones 1 and 2
Hold/Abort, Auto/Manual, Gas Fired, and
Manual Release. (S/C gives active condition
Circuits Monitored for O/C only
although a resistance of up to 500 Ω will still
give an active condition.
Maximum Loading 2mA per Zone
No. of Gas Area One
Release Time for Digital Extinguishant 4 sec. to 5 min.
LF / GD
High Performance Gas Detector

Features:

• Gas Level Indicators


• Power On, Gas Alarm and Warm-up
LED Indicators
• Reset Button
• Built-in Buzzer
• Gas Sensitive Sensor
• Auto Analysis
• Detects Combustible Gases
• Quick Response Time
• Relay Output
• Rigid steel Powder Coated Cabinet
• 220V AC Operation
• Wall Mount

Description:

The LF/GD High Performance Gas Detector is lower (for propane, butane) then at the
used to detect various types of combustible probable gas leak point. The horizontal
gas. It is used mainly where there are distance should not be more than 3 meters
possibilities of gas leakage like in chemical and the detectors must not be placed in
plants, gasoline stations, pharmaceutical humid or drafty areas. It is suggested that
factories, etc. the detector is tested for good operation
every 6 months or if it changed position.
When the detector is activated, the red LED
(Alarm LED) lights and the internal buzzer will It contains a gas leakage density rate
give an alarm sound. The green LED shows indicator equipped with 9 different levels.
the presence of the mains power supply.
When first installed, the yellow LED (Warm-up The detector’s design widely applies to all
LED) will light for 10 seconds until the sensor kinds of industrial and commercial
compensates to its surrounding. constructions with its high resistance to
humidity, high reliability and ease of
Depending on the monitored gas, the unit installation.
must be placed higher (for methane) or
Wiring Diagram:

Mains Fuse
1.5AF 1"

Trans. 12V RES R ALARM


SEC. + - NA NC CM + -

F
N
NA
NC
CM

Relay 12V

+ -
12 V
Battery
220 V AC

Dimensional Details:

20mm

61mm

122mm 122mm

30mm 61mm

15mm 15mm

20mm 76mm 76mm 20mm


70mm

70mm

192mm
TECHNICAL SPECIFICATION:
Mains Voltage 220 VAC 50/60 Hz
Battery Voltage 12 VDC
Standby Current 80 mA
Alarm Current 130~250 mA
Heater Voltage 2.225 VDC
Auxiliary Nominal Voltage 12 VDC @ 1.5 A
Auxiliary Relay Contacts 24 VDC/5A
Sensitivity Range 1000 to 40000 ppm
Sensitivity Gas/Air 75
Response Time 2 sec.
Gas Concentration 2000 ppm CS 1110
Mains Supply Protection 1.5AF 1" Glass Fuse
Circuits Protection 2.0 AF 20 x 5 mm Glass Fuse
Dimension 192 x122 x 70 mm
LF-HD-4112
Heat Detector

Features:

• Microprocessor Based Design


• High Accuracy of Fire Detection
• Rate of Rise and Fixed Temperature
• Quick Fire Alarm Transfer Speed
• Polarized Wiring
• Provision for Remote LED Indicator
• Ease of Maintenance
• Multiple Sensitivity Settings
• Up to 30 devices per zone
• 2 LED’s for 360deg. Viewing Angle

Description:
The LF-HD-4112 Conventional Type Heat The LF-HD-4112 Conventional Heat Detector
Detector identifies fire with both rapidly rising and also has the provision of connecting a remote
gradually increasing temperature. It has three LED indicator.
levels of fixed temperature settings to adapt itself
to the local temperature of the area being The detector’s design widely applies to all kinds
protected. of industrial and commercial constructions with its
high resistance to humidity, wide operating
The detector utilizes a modern, accurate, state of temperature range, high reliability and ease of
the art Negative Temperature Coefficient (NTC) installation.
thermistor that senses thermal changes in the
protected area. And combined with the data
stored in its non-volatile memory, the detector
sends out alarm information to the Fire Alarm
Control Unit during a rapid rise of heat or upon
reaching its pre-set temperature rating.
Wiring Diagram:

+24 VDC +24 VDC +24 VDC

3 3 3
To Initiating
Circuit of LIFECO 4 4 4 EOL
Optional Optional Resistor
Conventional Panel 2 Remote 24VDC 2 Remote 24VDC 2 (5.6K)
LF-4000 Series LED Indicator LED Indicator
1 1 1
+ +
- -

GND GND GND

Dimensions and Installation Details:

Note: All dimensions are in millimeters

Sensitivity Adjustment:

DETECTOR OPERATING CHART


Alarm
Normal Sensitivity - 66°C / 150°F 66

Alarm
55
Temperature
( °C )

PCB High Sensitivity - 58°C / 136°F


25

Low Sensitivity - 74°C / 165°F 0 60


Time (sec.)
TECHNICAL SPECIFICATION:
Sensitivity Settings I (high) 58℃
II (normal) 66℃
III (low) 74℃
Maximum Allowable Spacing 15m
Approx Weight 112g (with base)
Temperature Rating -10℃ ~ 55℃
Input Voltage 16 ~ 32 VDC
Standby Current 30μA
Alarm Current 40mA
Peak Current 4mA
Relative Humidity 0-95% non condensing
Led Indication (Red) Pulsing Standby
Steady Alarm
Material ABS Plastic
Color Off-White
LF-MCP-4103
Conventional Manual Fire Alarm Call Point

Features:
• Quick Fire Alarm Transfer Speed
• 2 LED’s Alarm Indicator
• Easy Operation – Push to Activate
• Resettable Type using Glass Return Unit
• Firefighter’s Telephone Extension Jack Input
• No Polarity
• Ergonometric Construction
• Durable Design
• High Performance at Low Cost

Description:
The LF-MCP-4103 Conventional Manual Call Point An optional telephone jack is also fitted on the unit. In
satisfies the requirements for a manual fire alarm cases where a Fire Host Telephone is installed, plug-in a
initiating device. With it’s sleek and durable design, it is firefighters telephone extension on the bottom of the
easily observed yet does not hinder with building design call point and it would immediately connect to the Host
and can be fitted along corridors, hallways and exits for Telephone Controller.
easy access to operate in cases where there is a
requirement for activating an alarm signal. The detector’s design widely applies to all kinds of
industrial and commercial constructions with its high
It contains a normally open switch which activates upon resistance to humidity, wide operating temperature
pressing on the glass window. Since there is no range, high reliability and ease of installation.
requirement of breaking to initiate the alarm, the device
is safe for use by any personnel who requires to manually
initiate a fire alarm. The Glass Return Unit is used to reset
the device.

Lichfield Fire & Safety Equipment Co. Ltd Tel: +44 (0) 870 066 44 01
Saturn Centre, 2nd floor, Suite 4, Spring Road, Fax: +44 (0) 870 066 44 02
Ettingshall, Wolverhampton WV4 6JX, United Kingdom. email: info@lifeco-uk.com
Wiring:

Installation:

Note: The optional telephone extension would only


operate together with a Host Fire Telephone Controller Glass Return Unit

Lichfield Fire & Safety Equipment Co. Ltd Tel: +44 (0) 870 066 44 01
Saturn Centre, 2nd floor, Suite 4, Spring Road, Fax: +44 (0) 870 066 44 02
Ettingshall, Wolverhampton WV4 6JX, United Kingdom. email: info@lifeco-uk.com
LF-MCP-4103 Conventional Manual Call Point

TECHNICAL SPECIFICATION:
Operating Voltage 16~32VDC
Alarm Current 40mA
Standby Current 0
Operating Temp -10 ~ 55ºC
Relative Humidity 0 ~ 95% RH
Color Red
Weight 116g
Dimensions 120 x 93.5 x 45.3mm

Dimensional Details:

Lichfield Fire & Safety Equipment Co. Ltd Tel: +44 (0) 870 066 44 01
Saturn Centre, 2nd floor, Suite 4, Spring Road, Fax: +44 (0) 870 066 44 02
Ettingshall, Wolverhampton WV4 6JX, United Kingdom. email: info@lifeco-uk.com
Distributor:

Lichfield Fire & Safety Equipment Co. Ltd


Saturn Centre, 2nd floor, Suite 4, Spring Road,
Ettingshall, Wolverhampton WV4 6JX, United Kingdom.
Tel: +44 (0) 870 066 44 01, Fax: +44 (0) 870 066 44 02
email: info@lifeco-uk.com, Website: www.lifeco-uk.com
LF-PE-4111
Optical Smoke Detector

Features:

• Microprocessor Based Design


• High Accuracy of Fire Detection
• Quick Fire Alarm Transfer Speed
• Special Chamber Design
• Polarized Wiring
• Provision for Remote LED Indicator
• Ease of Maintenance
• Multiple Sensitivity Settings
• Up to 30 devices per zone
• 2 LED’s for 360deg. Viewing Angle

Description:
The LF-PE-4111 Conventional Type Three levels of sensitivity is also provided with
Photoelectric Smoke Detector uses a specialized the detector using jumper selections. Depending
smoke chamber design, which could sense the on the application, the sensitivity is set by
presence of smoke particles produced by fast removing the PCB mounting plate and shorting
combustion or slow smoldering fire. Combining the terminals to achieve the desired setting.
fire algorithms stored on its memory with the
special three part design of the smoke chamber The LF-PE-4111 Conventional Type
and given the photo-sensor’s viewing angle, the Photoelectric Smoke Detector also has the
detector can effectively sense both white smoke provision of connecting a remote LED indicator.
and black smoke with virtually no false alarms. A
maximum of thirty smoke detectors can be The detector’s design widely applies to all kinds
installed on a single zone. of industrial and commercial constructions with its
high resistance to humidity, wide operating
Accurate analysis of fire is achieved using it’s temperature range, high reliability and ease of
built in microprocessor and fire data stored in its installation and configuration.
non-volatile memory. With the detectors
automatic environmental compensation settings,
it would adjust itself according to its environment
or application thus improving the veracity of fire
judgment.
Wiring Diagram:

+24 VDC +24 VDC +24 VDC

3 3 3
To Initiating
Circuit of LIFECO 4 4 4 EOL
Optional Optional Resistor
Conventional Panel 2 Remote 24VDC 2 Remote 24VDC 2 (5.6K)
LF-4000 Series LED Indicator LED Indicator
1 1 1
+ +
- -

GND GND GND

Dimensions and Installation Details:

Note: All dimensions are in millimeters

Sensitivity Adjustment:

DETECTOR OPERATING CHART

Normal Sensitivity
Alarm % Set Smoke
Concentration
Smoke Coefficient

PCB High Sensitivity

e
ok
Sm Environmental
Low Sensitivity Threshold

8 sec verification
TECHNICAL SPECIFICATION:
Maximum Detector Area of Coverage Area ≤ 80㎡ Height ≤ 12m
Area > 80㎡ 6m < Height ≤ 12m
Height ≤ 6m
Air Velocity Range 0—4000 ft/min
Maximum Allowable Spacing 9m
Approx Weight 116g (with base)
Temperature Rating -10 °C ~ 55 °C
Operating voltage 16~32 VDC
Standby Current 30μA
Alarm Current 40mA
Peak Current 4mA
Relative Humidity 0-95% non-condensing
Led Indication (Red) Pulsing Standby
Steady Alarm
Material ABS Plastic
Color Off-White
LFR-100
LED Remote Indicator

Features:

• Easy Installation
• Wide Viewing Angle
• Low Profile Design
• Low Power Consumption
• High Precision and Stability
• Quick Fire Alarm Transfer Speed
• High Accuracy of Fire Detection
• 2 LED Indicators

Description:

The LFR-100 LED Remote Indicator is an The indicator’s design widely applies to all
attractive device used in installations where a kinds of industrial and commercial
detector going to alarm is likely to occur behind constructions requiring a local visual
a locked door, inaccessible rooms, or in a indicator such as process control, security
ceiling void to provide indication of the and shut down operations, with its high
activation of a fire detector. reliability and ease of installation.
Dimensional Details:

85mm
33mm

85mm 85mm

Wiring:

(+) (+) (+)


ZONE

3 3 3
4 4 4 EOL
CONTROL
LED LED RESISTOR
PANEL 2 2 2 (5.6K)
1 1 1

(-) (-)
(-) (-) (-)
GND

TECHNICAL SPECIFICATION:
Operating Voltage 24 VDC (5~28V)
3.3 VDC (2~5V)
Operating Current 0.6~20mA
Alarm Red LED Flash
Dimension 85 x 85 x 33mm
Weight 50 g
Color White
Material PC Polycarbonate
LF - RP
Fire Alarm Repeater Panel

Features:

• 1 to 36 Zone Control Panels


• Built-in Buzzer
• Rigid Steel Powder Coated Cabinet
• 24 VDC Operation
• Used with LF-CP Series Fire Control Units
• Wall Mounting
• LED Status Indicators

Description:

The LF-RP Fire Alarm Repeater Panel is The LF-RP Repeater Panel is designed to act
manufactured based on advanced as a low cost repeater connected to a LF-CP
technology while maintaining high quality Series Fire System.
during assembly. It is of solid state circuitry
and is designed and tested to meet the The Repeater Panel would be used wherever
requirements of industrial or commercial there is a need to relay status information to
applications. multiple points to inform key personnel.
Repeater Panel Termination:
ALL AREA DETECTOR
SOUNDER (ZONE)

MAINS FUSE
1AF 1"

MAINS FUSE BLOCK


1AF 1"
Main Panel CERAMIC

NOTE

GND
AC 220V
BATTERY

Repeater Panel

Dimensional Details:

Note: All dimensions are in millimeters


LF-SD-40
Battery Operated Smoke Detector

Features:

• Photo-electric Type
• Battery Operated (9V battery included)
• High Accuracy of Fire Detection
• Special Chamber Design
• Ease of Maintenance
• Easy to Install with Mounting Hardware
Included
• Ideal for Business and Homes
• Test Button for Easy Recommended Monthly
Testing
• Loud 85dB Alarm Signal
• Low Battery Warning
• 220V AC Optional*

Description:

The LF-SD-40 Battery Operated Smoke cost. This detector monitors the air. When it
Detector uses a specialized smoke chamber senses smoke, it sounds its built-in alarm horn.
design, which could sense the presence of It can provide precious time for you and your
smoke particles produced by fast family to escape before a fire spreads.
combustion or slow smoldering fire. The
detector can effectively sense both white Its battery life can last over a year and it also
smoke and black smoke with virtually no false has a low battery warning wherein the unit
alarms. beeps every 50 seconds for a minimum of 7
days indicating that the battery needs to be
The smoke detector is designed to give early replaced.
warning of developing fires at a reasonable
Detector Operating Chart:

Consistence
(%)

Consistence be set

Time
30 (sec.)
0
The LED will flash and
Sensor operating Delay time for buzzer on in the
alarm (in 15 sec.) event of an alarm

Initial of fire & The smoke arise to


smoke arising consistence be set,
the detector shall
be activated in 30
sec.

TECHNICAL SPECIFICATION:
Effective Warning Area Height above the ground: Below 4M 4 ~ 8M 8 ~ 15M
Building: 100 M2 50 M2 30 M2
Operating Light Monitoring: Every 50 sec.
Alarm Active: Flash
Operating Voltage 9V DC
Operating Temperature 0˚C to 60˚C
Nominal Sens 2.3±1.2% FT Obscuration
Sound Loud 85dB Alarm Signal
Test Function Press testing button
Relative Humidity 0 ~ 95%RH
Weight 145g
Diameter 126mm
Height 35mm
Color Ivory
Material ABS Polycarbonate
Aux. Relay rating 1A @ 30V DC / 0.5A @ 125V AC

ORDERING INFORMATION
Model Number Operating Voltage
LF-SD-40 9V DC
LF-SD-40AC 9V DC and 220 V AC (50/60 Hz)
LF-SI and LF-SS
Siren, Siren with Strobe

Features:

• Quick Response Time


• 100+5dB (@24v DC)
• Piezoelectric Horn
• High Performance at Low Cost
• Integrated Electronics
• High Intensity Strobe*
• With Reverse Polarity Protection
• Ease of Maintenance
• Easy to Install
• 2-wire Operation
• Ceiling or Sidewall Mount

Fire Alarm Siren (LF-SI) and Siren with Strobe (LF-SS)

*Applicable to LF-SS

Description:

The LF-SI/SS Audible Strobes and Sirens are The mounting holes are hidden when the
designed for maximum performance, reliability cover is placed. Together with the modern
and cost-effectiveness. It adopts a built-in style of the strobe unit and the contour of the
integrated circuit, a piezoelectric sounder and device, makes it appealing with any building
high intensity strobe which when combined, wall design.
produces high energy conversion efficiency for
effective output of light and sound while The indicator’s design widely applies to all
utilizing a minimum amount of power. kinds of industrial and commercial
constructions with its high resistance to
The LF-SI/SS can be mounted by opening the humidity, wide operating temperature
front cover and installing the body of the range, high reliability and ease of installation
device to a standard 3” square box. and configuration.
Dimensional Details:

81.5 81.5

24 AWG 24 AWG
Black Black
Red Red
81.5 81.5
5±2 5±2

300±20 300±20

22

32 30

LF-SI (SWEEP SIREN) LF-SS (ALARM SIREN)

TECHNICAL SPECIFICATION:
Input Voltage Range 24VDC 12~30VDC
Sound Output 100 ±5dB
Operating Temperature -10˚C ~ + 60˚C
Continue Operation Test OVER 72 Hours
Life Test "ON" 1 minute, "OFF" 30 seconds
Strobe* Over 8000mcd. (6pcs. Super bright LED)
Duty Cycle at 24 VDC Continuously over 500 Hours period
Material ABS/polycarbonate
Color Red

LF-SI Siren *LF-SS Siren w/ Strobe


Operating Current 22 ~ 28mA 50 ~ 65mA
Tone Type Sweep Siren Alarm Siren
Dimensions (mm) 81.5 x 81.5 x 32 81.5 x 81.5 x 52