Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Description Value: Printed From Grundfos CAPS

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Description Value H TP 50-430/2

Product name: TP 50-430/2 A-F-B BQQE (m) Q = 36 m³/h


Product No: 96087225 H = 33.4 m
EAN number: 5700395311914 40
Pumped liquid = Water
Price: On request Liquid temperature = 20 °C
36
Density = 1000 kg/m³
Technical:
Speed for pump data: 2920 rpm 32
Actual calculated flow: 37.5 m³/h
Resulting head of the pump: 32.5 m 28
Head max: 430 dm
Actual impeller diameter: 177 mm 24
Shaft seal: BQQE
Curve tolerance: ISO 9906 Annex A 20
Pump version: A
16
Materials:
Pump housing: Cast iron 12
EN-JL1040
ASTM A48-40 B 8
Impeller: Bronze
DIN W.-Nr. 2.1096.01 4
ASTM B584-C83600 Eta pump = 66.5 %
Material code: B Eta pump+motor = 59.5 %
0
0 5 10 15 20 25 30 35 40 Q(m³/h)
Installation: P
Maximum ambient temperature: 60 °C (kW)
Maximum operating pressure: 16 bar P1
Flange standard: DIN P2
5
Connect code: F
Pipe connection: DN 50 4
Pressure stage: PN 16
Port-to-port length: 340 mm 3
Flange size for motor: FF265
2
Liquid:
Liquid temperature range: 0 .. 90 °C 1 P2 = 4.93 kW
Liquid temp: 20 °C 0 P1 = 5.51 kW
Density: 998.2 kg/m³

Electrical data:
Motor type: 132SC
Efficiency class: 1
Number of poles: 2
Rated power - P2: 5.5 kW
Power (P2) required by pump: 5.5 kW
Mains frequency: 50 Hz
Rated voltage: 3 x 380-415 D V
Rated current: 11.2 A
Starting current: 1070-1170 %
Cos phi - power factor: 0,88-0,84
Rated speed: 2910-2930 rpm
Motor efficiency at full load: 90 %
Motor efficiency at 3/4 load: 90-89,5 %
Motor efficiency at 1/2 load: 88-87 %
Enclosure class (IEC 34-5): 55
Insulation class (IEC 85): F
Motor protec: PTC
Motor No: 87312229

Others:
Net weight: 86.4 kg
Gross weight: 102 kg
Shipping volume: 0.236 m3

Printed from Grundfos CAPS 1/5


96087225 TP 50-430/2 50 Hz

H TP 50-430/2
(m) Q = 36 m³/h
H = 33.4 m
Pumped liquid = Water
Liquid temperature = 20 °C
40
Density = 1000 kg/m³

36

32

28

24

20

16

12

4
Eta pump = 66.5 %
Eta pump+motor = 59.5 %
0
0 5 10 15 20 25 30 35 40 Q(m³/h)
P
(kW)

6 P1

P2
5

1
P2 = 4.93 kW
0 P1 = 5.51 kW

Printed from Grundfos CAPS 2/5


96087225 TP 50-430/2 50 Hz

cos phi TP 50-430/2 + 132SC 5.5 kW 3* 400 V, 50 Hz I


eta (A)

1 20

cos phi
eta

0.8 16

0.6 12

0.4 8

0.2 4

P2 = 4.93 kW
cos phi = 0.83
eta = 89.5 %
I = 9.6 A
0 0
0 1 2 3 4 5 6 7 P2(kW)
n P1
(rpm) (kW)
n
2800 12

2600 10

2400 P1 8

2200 6

2000 4

1800 2
P1 = 5.51 kW
n = 2940 rpm 0

Printed from Grundfos CAPS 3/5


96087225 TP 50-430/2 50 Hz

150 150
300
134 220

734
RP 1/4

228
115
50
133 119 340

M16
144

170

Note! All units are in [mm] unless others are stated.


Disclaimer: This simplified dimensional drawing does not show all details.

Printed from Grundfos CAPS 4/5


96087225 TP 50-430/2 50 Hz

+T +T +T

CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY


IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE
TO AMPLIFIER
RELAY
L1 L2 L3

THERMISTORS PTC ACCORDING TO DIN 44082


+T +T +T

TO AMPLIFIER
RELAY
L1 L2 L3

Note! All units are in [mm] unless others are stated.

Printed from Grundfos CAPS 5/5

You might also like