SLN

DESCRIPTION UNIT QTY RATE AMOUNT


O

A SUBSTATION'S

4 way RMU (20D + 2 VL) with DAS fabricate , supply erection of ring main
unit made out of 1.6/2mm sheet steel encloser with powder coated paint
shade of 0481 with two tier system and outdoor type. Consisting of 02 No's
load break switch of 630 Amps incomes and two No's of SF6 insulated VCB
as outgoing of 630 Amps outdoor motorized with DAS, single side
extensible with E/F, O/C protection with FPI without RTU cable size
240Sqmm as incomer and outgoing as per BESCOM specification. set 2

5 way RMU (20D + 2 VL) with DAS fabricate , supply erection of ring main
unit made out of 1.6/2mm sheet steel encloser with powder coated paint
shade of 0481 with two tier system and outdoor type. Consisting of 02 No's
load break switch of 630 Amps incomes and two No's of SF6 insulated VCB
as outgoing of 630 Amps outdoor motorized with DAS, single side
extensible with E/F, O/C protection with FPI without RTU cable size
240Sqmm as incomer and outgoing as per BESCOM specification. set 1

3 Double pole structure for power tapping supply installation


11KV outdoor type 2 sets 400 Amps group operating switch's
with angle iron frame supporting system bot ruts fastener's
etc along with 9mts long RCC pole of BESCOM specification. set 1
1
B MEDIUM VOLTAGE CABLE

1 Supply and laying testing and commissioning of 1100V grade


XLPE insulated PVC sheeted steel wire armoured aluminium
conductor cables, the cable laid in hume pipe underground

a) 3.5 core 240sqmm UG cable mtrs 4850


4850

b) 4Core 10sqmm UG cable mtrs 5180


5180

2 Supply and install cable termination for the cable including


compression type chrome plated brass gland and lugs crimping
complete.

2.1 3.5 core 240sqmm cable No's 84


2.2 4 core 10sqmm cable No's 220

C OUTDOOR TYPE FEEDER PILLAR BOX DISTRIBUTION BOARD

3 Supply installation testing and commissioning of distribution


boards suitable for 415V 3phase 4 wire distributing system the
panel floor mounting with angular frame with sheet enclosing with
waterproof outdoor type consisting of 2 no's of 250 Amps switch
as incoming and outgoing loop in loop out system with alumunium
bus bar wit two tier system with rewirable fuse cutouts connected
through solid busbars. Busbars provided with heat shrinkable
insulated sleeves the panel have two separate cable entry box
either side of the box for incoming and ougoing cables and earthing
bolt provided the panel fabricated out of 14 SWG sheet steel enclosure
with epoxy powder coated paint finish complete
a) outdoor type feeder pillar box for individual plot connection No's 34
34

b) Outdoor type low tension feeder pillar box with consisting of 6 No's
250 Amps moulded case circuit breaker with 300 Amps aluminium
solid bus bar with PVC insulation with heat shrinkable separate
cable alloy for outgoing and incoming cable's fabriated with 14 SGW
CRCA sheet steel enclosure with EPOXY powder coated paint colour
shade siemens grey finish complete. set 1
1

C) Outdoor type low tension feeder pillar box with consisting of 4 No's
250 Amps moulded case circuit breaker with 300 Amps aluminium
solid bus bar with PVC insulation with heat shrinkable separate
cable alloy for outgoing and incoming cable's fabriated with 14 SGW
CRCA sheet steel enclosure with EPOXY powder coated paint colour
shade siemens grey finish complete. set 2
2

D TRANSFORMER

1 Supply testing and commissioning 433 V 250 KVA capacity step


down oil cooked alluminium wood floor mounted transformer
with cable outing box for LT and HT side mounted on KMC channel
bold nut hardware etc., complete set sets 7
7

E H.T CABLE
1 Supplying laying of testing and commission of 3 core 240 sqmm 11KV
(XLPE) aluminium conductor galvanized steel round wire armoured and
over all extruded pvc ST - 2 sheathed cable confirming to IS 7098 9part ll)
2011 with the latest Amendmnets. mtrs 1350
1350

2 Supplying eretion of 240Sqmm HT cable straight through joint kit. No's 4


4

F H.T CABLE TERMINATION

6.1 Supply and making of termination joints for 11KV 3 core 240 sqmm
for XLPE insulated aluminium conductor cable sealing epoxy
compound complete set No's 14
14

6.2 Supply and making of termination outdoor pot head heat shrinkable
to connect to GOS at tapping point. No's 2
2

H STREET LIGHT POLE/ FIXTURE

1 Supply and erection of street light pole with 70 mtrss long size of
125mm and 100mm swaged type with floor grouted with 1:2:4 pcc and
short bracket suitable for 70 watts LED outdoor type fixture with
control gear box as per BESCOM specification. No's 107
107

1.1 Supply and fixing of 40watts LED street light weather proof fixture No's 107
107
1.1 Supply and fixing of control gear box for fixture. No's 107
107

Excavation and back filling of cable trench in all kind soil. cum 2110

1.2 50mm jelly spreading for the transformer substation as per BESCOM
requirements Sqm 200
200

G EARTHINGS

1 Supplying and making of earthing pit including excavation back filling of


50mm dia GI pipe of 2mtrs long with alternate layer of salt and charcoal
etc GI bold ruts etc. No's 68
68

1.2 Supply and making of earth pit using 600 X 600 X 3mm copper plate
including excavation back filling etc. No's 7
7

1.4 Earthing strips of various size of copper / GI L/S

H MISCELLANEOUS

1 Supply and laying of 200mm DWCpipe for road crossing for cable Rmt 750
750
1.1 Construction of 450mm X 450mm X 450mm depth chamber with cover
as EB requitement. No's 34
34

1.2 Supply and laying of 50mm dia uPVC pipe of 6kg pressure for individual
plots for service main, incliusive of fittings and erection. Rmt 13300

1.3 Supply and fabricate chain link fencing all round the transformers
substation using steel vertical angle support of 2 mtrs height and get for
each substation Rmt 95
95

I INCIDENTAL CHARGES

1 professional charges to obtain 2250KVA power sanction from chief


engineer's office's / KPTCL L/S

1.1 Incidental charges to obtain transformer approval from 100 KVA to


250KVA from technical (Director) offices. L/S

Incidental charges to obtain approval for transformer, cable and feeder


1.2 pillar box Technical advises and quality control offices L/S

1.3 Electrical inspectorate chargesto obtain entire layout transformer


feeder pillar box cable etc from chief electrical inspector of karnataka L/S