Mid 039 - Cid - FMI 05: Troubleshooting
Mid 039 - Cid - FMI 05: Troubleshooting
Mid 039 - Cid - FMI 05: Troubleshooting
Page 1 of 3
Previous Screen
Welcome: nait1
Product: EXCAVATOR
Model: 319D EXCAVATOR BZH
Configuration: 319D Excavators BZH00001-UP (MACHINE) POWERED BY C4.2 Engine
Troubleshooting
311D, 312D, 312D2, 313D, 313D2, 314D, 315D, 318D, 318D2 and 319D Excavators
Machine Electronic Control System
Media Number -KENR5924-14 Publication Date -01/03/2015 Date Updated -16/01/2019
i05429126
Illustration 1 g02027340
Schematic of the Squeeze Pressure Sensor
This diagnostic code is recorded when the ECM reads the signal voltage of the pressure sensor as
being too low.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 03/11/2020
319D Excavators BZH00001-UP (MACHINE) POWERED BY C4.2 Engine(SEBP48... Page 2 of 3
A. Turn the disconnect switch and the key start switch to the ON position.
C. Observe the status of the diagnostic code. Disconnect the machine harness from the sensor.
Expected Result:
The diagnostic code will remain active if the sensor is not the cause of the problem. The sensor is
the cause of the problem if the diagnostic code is NO longer active.
Results:
• OK - The diagnostic code remains active. The sensor has not failed. The machine harness
may have failed or the ECM may have failed. Proceed to test step 2.
Repair: The machine harness and the ECM are operating properly. The sensor has failed.
Replace the sensor.
STOP
B. Turn the key start switch and the disconnect switch to the OFF position.
D. At the J1 machine harness connector, measure the resistance from contact J1-16 (M906-BU
(Blue)) to all source of ground.
Expected Result:
Results:
• OK - The resistance is greater than 5 ohms. The machine harness is correct. Proceed to test
step 3.
Repair: There is a short in the machine harness. The short is between the signal circuit
(wire M906-BU(Blue)) and the circuit with the low resistance measurement. Repair the
machine harness or replace the machine harness.
STOP
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 03/11/2020
319D Excavators BZH00001-UP (MACHINE) POWERED BY C4.2 Engine(SEBP48... Page 3 of 3
Expected Result:
Results:
• YES - The diagnostic code is NO longer active. The diagnostic code does not exist at this
time. The initial diagnostic code was probably caused by a poor electrical connection and/or
a short at one of the disconnected and reconnected harness connectors . Resume normal
machine operation.
STOP
• NO - The diagnostic code has not been corrected. The ECM has failed.
Repair: A failure of the ECM is unlikely. Exit this procedure and perform this diagnostic
code procedure again. Replace the ECM if the cause of the diagnostic code is not found. See
Testing and Adjusting, "Electronic Control Module (ECM) - Replace".
STOP