Hardness Tester
SHOCK-
NOVOTEST T-UD2
PROOF
СOVER

High-precision, easy in
operation and reliable with the
most affordable price in the
world among the analogues!

UCI probe Leeb probe

The advantages of Hardness Tester NOVOTEST T-UD2:


✓ hardness measurement of any mass products ✓ convenience and ease of measurement
with a thickness of 1 mm – inaccessible to ✓ optimized number of buttons
the dynamic (Leeb) hardness testers (small ✓ contrast display with bright back-lighting
parts, thin-walled structures, pipes, tanks, ✓ automatic recognition of probe
steel sheets, articles of complex shape, hard- ✓ indication of the type of connected probe
ness control of metal coatings, etc.) ✓ calibrations stored in memory of probe
✓ small imprint after measuring (mirror surfaces of ✓ very easy in operation and calibration
shafts necks, blades, gear teeth, etc.) ✓ internal memory and communication
✓ measuring the hardness of the surface with PC
hardened layer ✓ new, intuitive menu with tips on the buttons
✓ wide range of hardness ✓ extended temperature range
✓ only basic function, nothing extra (frost, down to - 40°C)
✓ possibility to use in field conditions with high ✓ water resistant case
humidity and dust ✓ rubber bumper protected case
The device works with both ultrasonic contact impedance (UCI)
and dynamic (Leeb) probes. User get the benefits of two methods
of measurement – it is the maximum that can be obtained from
a portable hardness tester.

Dynamic (Leeb) probe is used for measuring


the hardness of non-ferrous metals, cast iron,
coarse-grained materials, massive products etc.

The ultrasonic contact


impedance (UCI) probe
is used for measuring the
hardness of small items,
objects with a thin wall, complex form, and to measure the
hardness of surface hardened layers.

Can be equipped with three types of UCI probes:


Load Advantage or benefit Typical applications

Small forged products, cast materials,


98N Leaves relatively large dent. Suitable for heat-treated materials, etc.
low finished surfaces. Surface finish equiv-
(22.0 lbf) Turbine blades, inside tubes
alent to 30 grind or better. with ø> 90mm.
Considered to be the Universal type for Induction or carburized machined parts,
50N most general applications. e.g.. camshafts, turbines, weld inspec-
50N of downward hand pressure is re- tion, HAZ. Measurement in grooves,
(11.2 lbf) quired to activate the probe. Surface finish gear tooth flanks and roots Turbine
equivalent to 80 grind or better. blades, inside tubes with ø> 90mm.
Load is easy to apply; provides control to
test on a sharp radius. Only 10N of down- Ion-nitrided stamping dies and molds,
10N ward hand pressure is required to activate forms, presses, thin-walled parts
(2.2 lbf) the probe. Bearings, tooth flanks Turbine blades,
Surface finish equivalent to 150 grind or inside tubes with ø> 90 mm.
better.

Portable hardness tester T-UD2 has modes of measurement:

Normal mode Statistics mode Smart mode Signal mode


Sealed housing with rubber protective strips - Hardness testers is ideal for use in workshop
and field conditions with high humidity, dust, etc. Hardness tester has frost-resistant display
that allows user to use the device at any season and in any climatic zone of the Earth.

Combined Hardness Tester NOVOTEST T-UD2 specifications:


UCI probe types 1kgf (10N) 2.2 lbf, 5kgf (50N) 11lbf, 10kgf (98N)
Leeb probe types D, DC, DL, C, D+15, E, G
Indenter Diamond Indenter (UCI), Hardened ball (Leeb)
Measuring direction Any direction 360°

Data storage Limited only by the memory card

Measurement hardness range:


- Rockwell, HRC 20 - 70
- Brinell, HB 90 - 450
- Vickers, HV 230 - 940
- temporary resistance (tensile strength), MPa 370 - 1740
Measuring accuracy HV+ / - 3%; HRC+ / - 1,5%; HB+ / - 3%;
Hardness scale HRC, HB, HV, MPa
- UCI probe - pre-calibrated for steel.
- Leeb probe - pre-calibrated for steel, alloy
Materials steel, cast iron, stainless steel, aluminum,
bronze, brass, copper.
- Additional custom materials for calibration.
Operating temperature range, °C -20 to +50
Power supply 2 AA batteries
Instrument dimensions 120x60x25 mm
Weight of electronic unit with batteries 0.2 kg (without probes)
Battery life Not less 20 hours.

The device has PC software with


a comfortable and intuitive interface
 Standard set
of Hardness Tester NOVOTEST T-UD2
✓ Electronic unit ✓ 2 batteries AA ✓ Operating manual
✓ UCI probe ✓ Charger ✓ Software for PC
✓ Leeb probe ✓ USB cable ✓ Case

Available options for ordering


of Hardness Tester NOVOTEST T-UD2

✓ UCI probe ✓ USB-cable


✓ Leeb probe ✓ Set of measures
✓ Batteries of hardness
✓ Charger ✓ Case

Application of Hardness Tester


NOVOTEST T-UD2