Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Instruction Sheet Is Jf1719: - Style Number Jf1719Hd:: Package Contents

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

INSTRUCTION SHEET : IS - JF1719

STYLE NUMBER : JF1719HD


6 CORPORATE PARKWAY
GOOSE CREEK , SC . 29445
www . quoizel . com

PACKAGE CONTENTS ISSUED 09-2009 Revised 2009-10-23

Part Description Quantity


A Crossbar 1pc
B Green Ground Screw 1pc
C Mounting Screws (#8-32 UNC) 2pcs A

D Lock Washer (#8-32 UNC) 2pcs


E Hex Nut ( # 8-32 UNC) 2pcs J
F Mounting Ball 2pcs B
G Lock Screw 3pcs
H Finial 1pc K
Center Stem Assembly 1pc C
I
J Gig Ring 1pc
L
K Small Ring 3pcs
D
L Cap 1pc
M Side Arm 3pcs E
N Hex Nut (1/8IP) 1pc
F M
O Fixture Assembly 1pc
P Flat Washer 1pc G
Q Shade 1pc
N
H
O

! WARNINGS AND CAUTIONS


WARNING:
● Before beginning the installation, turn off electricity at the circuit breaker box or the main fuse box by
switching off the circuit breaker or removing the fuse.
CAUTION:
● These instructions are provided for your safety. It is very important that they are read completely before
the installation of your fixture. We strongly recommend that a professional electrician install the fixture.
● Disconnect fixture from the power source before replacing the bulb(s), making sure the bulb(s) had
sufficient time to cool down. DO NOT subject the lamp to any shock while lit as shattering of lamp may
result.

PREPARATION
● Before beginning installation of product, make sure all parts are present. Compare parts with package
contents list and diagram above. If any part is missing or damaged, do not attempt to assemble, install or
operate the product. Contact customer service for replacement part.
● Estimated Assembly Time : 20 - 30 minutes
● Tools Required for Assembly (not included) : Flathead Screwdriver , Phillips Screwdriver, Pliers,
Electrical Tape, Wire Cutters, Safety Glasses & 3, 100 Watt, Type - A Medium Base Bulbs.
● Helpful Tools (not included) : Wire Strippers.

1 OF 3
INSTALLATION INSTRUCTIONS STYLE NUMBER : JF1719HD

STEP 1 :
a. Place Small Rings over the Scrolls on the side of the Fixture
Assembly.
Small Ring Scroll
b. Attach the Hook end of the Side Rods onto the Small Rings
and then line up the end of the Side Rod onto the holes on
the Side Arms. Secure by threading Lock Screws into the Side Arm
ends of Side Rods. Hand tighten until snug. Side Rod

Lock Screw
Fixture Assembly

STEP 2: Mounting Screw


a . Screw the Mounting Screws into the Crossbar , place the Crossbar
Lock Washers over the Mounting Screws and thread the Hex Nut
Hex Nuts onto the Mounting Screws as shown . Secure the
position of the Mounting Screws by tightening the Hex Nuts
against the Crossbar .
b . Secure the Crossbar to the Outlet Box with Outlet Box
Screws . Lock Washer

Outlet Box
Outlet Box Screw

STEP 3 :
* Use Wire Connectors ( not supplied ) to connect the
WHITE OR RIBBED WHITE OR RIBBED
wires .
a . Connect the House Ground Wire to the Fixture Ground FROM HOUSE FROM FIXTURE
Wire.
b . Connect the House White ( or Ribbed ) Wire to the
BLACK ( OR RED ) WIRE BLACK OR SMOOTH
Fixture Supply Wire ( White or Ribbed Side ) .
c . Connect the House Black ( or Red ) Wire to the Fixture FROM HOUSE FROM FIXTURE
Supply Wire ( Black or Smooth Side ).
d . Wrap each connection with approved electrical tape and
carefully stuff all of the connected wires into the Outlet GROUND WIRE GROUND WIRE
Box . FROM HOUSE FROM FIXTURE

STEP 4 :
a . Place the Ceiling Canopy onto Outlet Box aligning 2 Outlet Box
holes in the Ceiling Canopy with 2 Mounting screws
threaded on the Crossbar and secure it against wall Mounting
Screw
with Mounting Balls . Ceiling
Canopy

Mounting Ball

2 OF 3
INSTALLATION INSTRUCTIONS STYLE NUMBER : JF1719HD

STEP 5 :
a . Screw the top end of the Center Stem Assembly into the hex
coupling underside of the Socket Cluster. Hand tighten
until snug.
b. Place the Big Ring onto the top of the Shade.
c. Pass the Shade with the Big Ring and the Flat Washer over
the end of the Center Stem. Secure by threading the Hex
Nut (1/8 IP) onto the stem. Hand tighten until snug. Socket Cluster
d. Place the Cap over the end of the Center Stem and secure
with the Finial. Hand tighten until snug.
Center Stem
Assembly

Big
Ring

Shade

Flat Washer
Hex Nut (1/8IP)

Cap

Finial

STEP 6 :
a . Install correct bulbs referring to fixture markings and / or labels for maximum wattage .

Your installation is completed now . Restore electricity . Retain this sheet for future reference .