Lithium Ion: Rechargeable Batteries
Lithium Ion: Rechargeable Batteries
Lithium Ion: Rechargeable Batteries
HONG KONG
Battery Handling and Precautions GPI INTERNATIONAL LIMITED
Gold Peak Building, 8/F., 30 Kwai Wing Road,
Kwai Chung, N.T., Hong Kong
Tel: (852) 2484 3333 Fax: (852) 2480 5912
Safety E-mail address: gpii@goldpeak.com
Website: http://www.gpbatteries.com.hk
Don't Dismantle Do not disassemble or modify the battery pack. The battery
SALES & MARKETING BRANCH OFFICES
pack is equipped with built-in safety/protection features. ASEAN
Should these features be disabled, the battery pack can leak, GP BATTERY MARKETING (SINGAPORE) PTE. LIMITED
97 Pioneer Road, Singapore 639579
emitting corrosive liquid, or it would overheat, burst or ignite. Tel: (65) 6559 9760 Fax: (65) 6559 9761
All rights reserved. No parts of this catalogue written or pictorial may be reproduced without the permission of GPI International Ltd.
MALAYSIA
Don't Short Circuit Do not connect the positive (+) and negative (-) terminals with a GP BATTERY MARKETING (MALAYSIA) SDN. BHD.
Lot 8, Jalan Pemberita U1/49,
metal object such as wire. Do not transport or store the battery Temasya Industrial Park,
40150 Shah Alam, Selangor Darul Ehsan, Malaysia
pack together with metal objects such as necklaces, hair pins, Tel: (60) 3 5569 3499 Fax: (60) 3 5569 3498
TAIWAN
Don't Put Into Fire Do not discard the battery pack into fire or heat it. Otherwise, GOLD PEAK INDUSTRIES (TAIWAN) LIMITED – TAIPEI OFFICE
8/F, No. 205 Sec. 1,Fu Xing South Road,
its insulation can melt down. Its gas release vent or safety Taipei 10666, Taiwan, R.O.C.
Tel: (886) 2 2772 9998 Fax: (886) 2 2731 4868/2741 0192
features will be damaged and/or its electrolyte can ignite,
CHINA
possibly leading to acid leakage, overheating, smoke emission, HUIZHOU CHAO BA BATTERY TECHNOLOGY CO., LTD
Lithium Ion
2/F., South of Hongye Industrial Building,
bursting and/or ignition on it. Tianluo Mountain, 14th Industrial District,
Huizhou City, Guangdong, China
(Postal Code: 516003)
Don't Put Into Water Do not immerse the battery pack in water or seawater, and do Tel: (86) 752 282 8428 Fax: (86) 752 280 2872
not allow it to get wet. Otherwise, the protective features in it
can be damaged. It can be charged with extremely high current
HONG KONG
GP BATTERY MARKETING (H.K.) LIMITED
Rechargeable
Gold Peak Building, 8/F., 30 Kwai Wing Road,
and voltage, abnormal chemical reactions may occur in it,
possibly leading to acid leakage, overheating, smoke emission,
Kwai Chung, N.T., Hong Kong
Tel: (852) 2420 0281 Fax: (852) 2494 9349 Batteries
KOREA
bursting and/or ignition. GP BATTERY MARKETING (KOREA) LIMITED
Kunsul Hoekwan Building, 9/F., 71-2 Non Hyun-Dong,
Kang Nam-Gu, Seoul, South Korea
Don't Pierce Do not pierce the battery pack with a nail or other sharp objects, Tel: (82) 2 549 7188/9, 2 516 3936/7
Fax: (82) 2 514 0623, 2 516 0621
strike it with a hammer, or step on it. Otherwise, the battery
pack will become damaged and deformed, internal short- U.S.A.
GOLD PEAK INDUSTRIES (NORTH AMERICA) INC.
circuiting can occur, possibly leading to acid leakage, 11235 West Bernardo Court, San Diego,
CA 92127-1638, U.S.A.
overheating, smoke emission, bursting and/or ignition. Tel: (1) 858 674 6099 Fax: (1) 858 674 6496/674 5883
CANADA
Don't Strike Or Do not strike or throw the battery pack. Otherwise, the protective GP BATTERY MARKETING INC.
Unit 7, 7780 Woodbine Avenue, Markham,
Throw feature in it may become damaged, it can be charged with Ontario, Canada L3R 2N7
Tel: (1) 905 474 9507 Fax: (1) 905 474 9452
extremely high current and voltage, abnormal chemical reactions
can occur in it, possibly leading to acid leakage, overheating, LATIN AMERICA
GP BATTERY MARKETING (LATIN AMERICA) INC.
smoke emission, bursting and/or ignition. 8370 NW, 66th Street, Miami, Florida 33166, U.S.A.
Tel: (1) 305 471 7717 Fax: (1) 305 471 7718
GPPA4RBL-A 05/06
Don't Direct Do not solder directly onto batteries. Always solder onto solder EUROPE
GP BATTERIES EUROPE B.V.
Soldering tag for connection. Otherwise, heat can melt down its insulation, Kortijzer 4, 5721 VE Asten,
The Netherlands
damage its gas release vent or safety features possibly leading Tel: (31) 493 681030 Fax: (31) 493 681039
POLAND
Distributed by: GP BATTERY (POLAND) SP. Z.O.O.
ul. Slowicza 19, PL-02170 Warsaw, Poland
Tel: (48) 22 868 0490 Fax: (48) 22 846 7535
U.K.
GP BATTERIES (U.K.) LIMITED
Summerfield Avenue,
Chelston Business Park, Wellington,
Somerset, TA21 9JF, United Kingdom
Tel: (44) 1 823 660 044 Fax: (44) 1 823 665 595
ITALY
GP BATTERY MARKETING ITALY S.R.L.
Via. Alessandro Volta 3,
20094 Assago (Mi), Italy
Tel: (39) 02 488 2512 Fax: (39) 02 488 2865
SCANDINAVIA
GPBM NORDIC AB
Grimboasen 5, SE-417 49, Goteborg, Sweden
Tel: (46) 31 558 600 Fax: (46) 31 556 813
Lithium Ion
Rechargeable Major Applications
Notebook Computers, Cellular Phones, Digital Cameras,
Batteries
Camcorders, Video CD/DVD Players, MD Players,
PDAs/Webpad, POS Terminals, Electronic Instruments,
Communication Devices, etc.
GP1022L14* 3.7 145 130 10.5 22.0 4.2 290 4.2 145
GP1029L20* 3.7 205 190 10.5 29.0 6.0 410 4.2 205
GP1051L35 * 3.7 355 340 10.5 51.0 10.3 710 4.2 355
1S1P 3.7
GP0836L15 * 3.7 155 140 8.3 36.0 4.5 310 4.2 155
GP0838L15 3.7 155 140 8.3 38.0 4.5 310 4.2 155
GP0840L18 3.7 180 165 8.3 40.0 4.8 360 4.2 180
GP1443L68* 3.7 680 630 14.2 43.0 16.0 1360 4.2 680
1S2P 3.7
GP1450L85 3.7 850 800 14.2 50.0 19.0 1700 4.2 850
GP1465L115 3.7 1150 1100 14.2 65.0 26.0 1725 4.2 1150
GP1750L125 3.7 1250 1200 17.0 50.0 26.0 1875 4.2 1250
GP1767L185* 3.7 1850 1800 17.0 67.0 37.0 1850 4.2 1850
GP1850L140 * 3.7 1400 1350 18.5 50.0 31.0 2100 4.2 1400 2S1P 7.4
GP1865L200S* 3.7 2050 2000 18.5 65.5 43.0 2050 4.2 2050
GP1865L220* 3.7 2200 2150 18.5 65.5 44.0 2200 4.2 2200
Typical Ambient Temperature : Charge : 0ºC to 45ºC / Discharge : -30ºC to 60ºC / Storage : -20ºC to 45ºC
* UL recognized model
2S2P 7.4
Performance Characteristics
3S1P 11.1
3S2P 11.1
3S3P 11.1
4S2P 14.8
* Apart from the standard items shown above, customised configurations are also available upon request.
Lithium Ion Rechargeable Batteries
Prismatic Models
GP503040L54* 3.7 540 510 5.0(T) x 30.1(W) x 40.0(H) 13 1080 4.2 540
Discharge
GP503048L78 3.7 780 750 5.0(T) x 30.1(W) x 48.0(H) 17 1560 4.2 780
GP503436L60R* 3.7 600 570 5.0(T) x 34.0(W) x 36.1(H) 14 1200 4.2 600 Discharge Current Size the discharge over-current protection elements
to be able to take the maximum current.
GP503449L98R* 3.7 980 950 5.0(T) x 34.0(W) x 49.4(H) 19 1960 4.2 980
GP582231L37* 3.7 370 340 5.8(T) x 22.0(W) x 31.0(H) 9 740 4.2 370 Discharge Temperature Discharge in the range of -20 to 60˚C. For prismatic
models, the lowest discharge temperature is -30˚C.
GP582237L43* 3.7 430 400 5.8(T) x 22.0(W) x 37.1(H) 11 860 4.2 430
GP582248L57* 3.7 570 540 5.8(T) x 22.0(W) x 48.0(H) 16 1140 4.2 570 Overdischarge Do not discharge below 2.8V/cell under significant
loads. Small leakage current may discharge the
GP603450L114R* 3.7 1140 1110 6.0(T) x 34.1(W) x 50.0(H) 24 2280 4.2 1140
cell further in some devices even after shut down.
GP603465L144 3.7 1440 1410 6.0(T) x 34.0(W) x 65.0(H) 32 2880 4.2 1440
GP623040L74* 3.7 740 710 6.2(T) x 30.0(W) x 40.0(H) 17 1480 4.2 740
Storage
GP623048L104* 3.7 1040 1000 6.2(T) x 30.0(W) x 48.0(H) 21 2080 4.2 1040
GP743442L118R* 3.7 1180 1150 7.4(T) x 34.0(W) x 42.0(H) 23 2360 4.2 1180 Storage Temperature Store at -20 to 45˚C. Significant permanent loss
can occur when storing at 60˚C for prolonged
GP813433L75* 3.7 750 720 8.1(T) x 34.0(W) x 33.0(H) 21 1500 4.2 750
period. Keep the battery away from fire.
GP813448L130* 3.7 1300 1270 8.1(T) x 34.0(W) x 48.0(H) 30 2600 4.2 1300
For prismatic models, the lowest storage
GP843042L105* 3.7 1050 1020 8.4(T) x 30.0(W) x 42.0(H) 23 2080 4.2 1040 temperature is -30˚C.
GP863734L120R* 3.7 1200 1170 8.6(T) x 37.0(W) x 34.0(H) 24 2400 4.2 1200 Long Term Storage Deterioration of cell capacity is slower at lower state
GP901940L63R* 3.7 630 600 9.2(T) x 19.1(W) x 40.0(H) 15 1260 4.2 630 of charge. Store at below 50% state of charge or
GP901942L70R* 3.7 700 670 9.2(T) x 19.1(W) x 42.0(H) 16 1400 4.2 700 about 3.7V. For extended storage period over one
year, recharge the battery to 3.7V to prevent
GP901948L80R* 3.7 800 770 9.2(T) x 19.1(W) x 48.0(H) 17 1600 4.2 800
overdischarge of the battery.
GP103450L180R* 3.7 1850 1800 10.0(T) x 34.0(W) x 50.0(H) 38 2775 4.2 1850
Typical Ambient Temperature : Charge : 0ºC to 45ºC / Discharge : -30ºC to 60ºC / Storage : -30ºC to 45ºC
* UL recognized model Equipment Design
# Dimension of bare cell before charging and cycling.
Reverse Polarity Provide mechanical stop so that the battery pack
Prevention cannot be inserted in a reverse manner. The
electrical contacts should be designed so that they
are difficult to short.
Damage Prevention The wiring and cells should be protected inside the
Due to Drop battery pack by designing so that they are difficult
to short.