Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Cat 3516B

Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

APPENDIX A

CATERPILLAR GENERATOR SPECIFICATIONS AND DRAWINGS


P O W E R
P A C K A G E

3516B
POWER PACKAGE
(Walk-In Sound
Attenuated Enclosure)

Shown with Caterpillar is leading the power generation


Optional Equipment marketplace with Power Solutions engineered
to deliver unmatched flexibility, expandability,
reliability, and cost-effectiveness.

FEATURES
The Caterpillar Power Package is bundled with ● Caterpillar dealers fill 99.7% of parts orders
the 3516B 60 Hz, 1800 rpm, 3-phase, 480/227 Volt, within 24 hours
diesel package generator set ● Caterpillar dealers have over 1844 dealer
ENCLOSURE branch stores operating in 166 countries
● The Cat Scheduled Oil Sampling (S•O•SSM )
● Application-engineered airflow to meet cooling
and sound requirements. program cost effectively detects internal engine
component condition, even the presence of
● Roof pitch prevents moisture accumulation
unwanted fluids and combustion by-products
● 43°C (110°F) ambient capability
● Wind load rated to 150 mph
● Roof load rated to 40 psf CAT 3516B TA DIESEL ENGINE
● Reliable, rugged, durable design
● Sound attenuated to provide a four point
● Field-proven in thousands of applications
logarithmic average of 72 dB(A) @ 50 feet
● Built in accordance with UL2200 rainproof worldwide
● Four-stroke-cycle diesel engine combines
designation
● Integrally insulated exhaust silencing system consistent performance and excellent fuel
economy with minimum weight and low
housed within the enclosure for operator safety,
emissions
maximum product life, and additional sound
attenuation
● 5000 gallon double wall, UL 142 Listed, CAT SR4B GENERATOR
closed-top diked, generator base tank with ● Matched to the performance and output
integral lift provisions characteristics of Caterpillar engines
● Compatible with Cat® generator set control ● Optimum winding pitch for minimum total
panel attachments harmonic distortion and maximum efficiency
FULL RANGE OF ATTACHMENTS ● Single point access to accessory connections
● Wide range of bolt-on system expansion ● UL 1446 recognized Class H insulation
attachments, factory designed and tested
SINGLE-SOURCE SUPPLIER CAT CONTROL PANELS
● Fully prototype tested with certified torsional ● Controls designed to meet individual
vibration analysis available customer needs:
EMCP II+ offers full-featured power metering
WORLDWIDE PRODUCT SUPPORT
and protective relaying
● Caterpillar dealers provide extensive post sale
● UL 508A Listed
support including maintenance and repair
agreements

LEHE2482

W H E R E T H E W O R L D T U R N S F O R P O W E R
3 5 1 6 B
P O W E R P A C K A G E

FACTORY INSTALLED STANDARD & OPTIONAL EQUIPMENT


System Standard Optional
Air Inlet Single element canister type air cleaner
Service indicator
Cooling Vertical Stacked Core Radiator sized for 43° C/110° F
Coolant drain line with valve
Fan and belt guards
Coolant level sensors
SCAC (3500B only)
Low coolant level alarm and shutdown
Caterpillar Extended Life Coolant
Exhaust Dry exhaust manifold
Flanged faced outlets
Muffler; pancake style, self-insulated, and internally mounted from
ceiling of enclosure
Attenuates specific PGS exhaust noise to a level consistent with
overall noise requirement
Fuel 5000 gallon double wall, UL 142 Listed, closed-top diked generator 3500 USG double wall UL142 listed,
base tank with integral lift provisions closed-top diked generator
Vent and emergency vents in accordance with NFPA30 base tank
Annunciator panel indicating rupture/overflow basin, low fuel level 2000 USG double wall UL142 listed,
and 90% full closed-top diked generator
Water separator installed, with fuel filter before engine base tank
Secondary fuel filters Base frame with optional 250 USG
Fuel cooler radiator mounted double wall UL142 secondary
Fuel priming pump containment listed day tank
Flexible fuel lines piped to tank Fuel transfer system
Fuel tank heaters
Generator 3-phase brushless, salient pole
Permanent magnet excited
6 lead (>1250 ekW @ 60 Hz)
Digital Voltage Regulator, 3-phase sensing
Class H insulation
Class F temperature rise (105° C prime/130° C standby)
Reactive droop
Bus bar connections
Winding temperature detectors
Anti-condensation space heaters, 820 Frames: 220-240 VAC, 1200 W
Circuit Breaker Floor standing circuit breaker enclosure:
Enclosure and • 3200 amp magnum DS Circuit breaker fixed mounted in
Distribution Panel NEMA 1 enclosure
• Manually operated
• 65 kA interrupt current @ 480 V
• 24 VDC shunt trip
• 4A-4B auxiliary switch
• Digitrip 220 trip unit with LI trip function and 3000A rating plug
• Secondary terminal kit
AC Distribution panel:
• Integrated into the floor standing breaker NEMA 1 enclosure
• 120/240V 3-wire distribution
• Breaker
• Provides power for lights and receptacles
• Provides power for battery charger, jacket water heaters,
and generator space heaters
• Includes fault protection and relays to de-energize jacket water
heaters and generator space heater when engine is running
Governing ADEMII
Control Panel EMCP II+ (Generator terminal box mounted) Load share module
Customer Control Module
Local alarm modules
Remote annunciator modules
Customer Interface Module
Synchronizing module
Auto starting aid: Switch
Engine failure relay
Lube Lubricating oil and filter
Oil drain line with valves
Gear type lube oil pump
Mounting 330 mm (13 in) structural steel rails
Spring-type, anti-vibration mounts (Seismic Zone 4) installed
between generator set and fuel tank base (or enclosure floor
if day tank is used)

LEHE2482

2
3 5 1 6 B
P O W E R P A C K A G E

FACTORY INSTALLED STANDARD & OPTIONAL EQUIPMENT


System Standard Optional
Starting/Charging 24 VDC/20 amp battery charger with float /equalize modes NiCad batteries and charger
and charging Battery heating pads
Jacket water heater, 6 kW total Jacket water heater, 12 kW total
45 amp charging alternator
Batteries with rack and cables
Battery disconnect switch
Enclosure Powder coated 14-gauge (minimum) galvanealed steel panels Powder coated exterior paint
Bolted panel construction using Caterpillar grade 8 fasteners colors — white, green,
Steel deck plate on floor ANSI61 gray, or Cat yellow
Three (3) lockable, gasketed personnel doors
Steps, OSHA rated, one (1) for each personnel door, three (3) total.
Two (2) access panels provided for bus bars and discharge
plenum access
Eight (8) 100 Watt incandescent lights with globes and guards.
Switches at each door (3 total)
Three (3) duplex GFI receptacles, one by each personnel door.
Removable lift provisions
General Right hand service
SAE standard rotation
Flywheel and flywheel housing — SAE No. 00

SPECIFICATIONS
CAT CONTROL PANELS
CAT SR4B GENERATOR
EMCP II+
Excitation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Permanent Magnet 24 Volt DC Control
Pitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.6666 NEMA 1, IP23 dust proof enclosure
Number of poles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Electronically dead front
Number of bearings . . . . . . . . . . . . . . . . . . . . . . . . . Single Bearing Lockable hinged door
Insulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL 1446 Recognized Generator instruments meet ANSI C-39-1
Class H with tropicalization and antiabrasion Generator terminal box mounted
IP rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Drip Proof IP22 Single location for customer connection
Alignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pilot Shaft UL508A Listed
Overspeed capability — % of rated . . . . . . . . . . . . . . . . . . . . . . 150 Panel illuminating lights
Wave form. . . . . . . . . . . . . . . . . . . . . . . . . . Less than 5% deviation Auto start/stop control
Paralleling kit/Droop transformer . . . . . . . . . . . . . . . . . . Standard Voltage adjustment potentiometer
Voltage regulator . . . 3 Phase sensing with selectable volts/Hz True RMS AC metering, 3-phase
Voltage regulation . . . . . . . . . . . Less than ± 1/2% (steady state) Digital indications for:
Less than ± 1% (no load to full load)
RPM
Telephone Influence Factor. . . . . . . . . . . . . . . . . . . . . Less than 50
Operating hours
Harmonic Distortion . . . . . . . . . . . . . . . . . . . . . . . . . . Less than 5%
Oil pressure
Coolant temperature
CAT DIESEL ENGINE System DC volts
L-L volts, L-N volts, Phase amps, Hz
3516B TA, V-16, 4-stroke-cycle water-cooled diesel
ekW, kVA, kVAR, kWhr, %kW, PF
Bore – mm (in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170 (6.7)
Shutdowns with indicating lights for:
Stroke – mm (in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190 (7.5)
Low oil pressure
Displacement – L (cu in) . . . . . . . . . . . . . . . . . . . . . . 69.06 (4214.3)
High coolant temperature
Compression ratio. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14:1
Low coolant level
Aspiration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TA
Overspeed
Fuel system . . . . . . . . . . . . . . . . . . . . . . . . . . . . Direct unit injection
Emergency stop
Failure to start (overcrank)
Programmable protective relaying functions:
Under and over voltage
Under and over frequency
Reverse power
Overcurrent (phase and total)
Programmable kW level relay
3 Indicator LED’s (programmable for fuel high, low and rupture)
4 spare alarm/shutdown inputs

LEHE2482

3
3 5 1 6 B
P O W E R P A C K A G E

ENCLOSURE OPERATING CHARACTERISTICS


3516B Power Package
60 Hz (1800 rpm)
Generator Set
Rating dBA @ Full Load Ambient Capability * °C (°F)
60 Hz/480 Volts
1m 7m 15 m SB PP
1640-2000 ekW 79.7 75 72 43° C (110° F) 43° C (110° F)
*Ambient measured with Caterpillar Extended Life Coolant

RATING DEFINITIONS AND CONDITIONS


Meets or Exceeds International Specifications: Ratings are based on SAE J1349 standard conditions.
● ABGSM TM3, AS1359, AS2789, BS4999, BS5000, BS5514, These ratings also apply at ISO3046/1, DIN6271, and BS5514
DIN6271, DIN6280, EGSA101P, IEC34/1, ISO3046/1, ISO8528, standard conditions.
JEM1359, NEMA MG1-22, VDE0530, 89/392/EEC, 89/336/EEC
Fuel rates are based on fuel oil of 35° API [@16° C (60° F)]
Standby — Output available with varying load for the gravity having an LHV of 42 780 kJ/kg (18,390 Btu/lb) when used
duration of the interruption of the normal source power. at 29° C (85° F) and weighing 838.9 g/liter (7.001 lbs/U.S. gal.).
Standby power in accordance with ISO8528. Fuel stop power
in accordance with ISO3046/1, AS2789, DIN6271, and BS5514. Additional ratings may be available for specific customer
Standby ambients shown indicate ambient temperature requirements. Consult your Caterpillar representative
at 100 percent load which results in a coolant top tank for details.
temperature just below the shutdown temperature.

Prime — Output available with varying load for an unlimited


time. Prime power in accordance with ISO8528. 10% overload
power in accordance with ISO3046/1, AS2789, DIN6271, and
BS5514 available on request. Prime power ambients shown
indicate ambient at 100 percent load which results in a
coolant top tank temperature just below the alarm temperature.

LEHE2482

4
3 5 1 6 B
P O W E R P A C K A G E

TOP VIEW

4647.7 (182.98) 3571.5 (140.61)

3302.0 (130.00)

SIDE VIEW/CUTAWAY
Rear Face of Cylinder Block

1793.9 (70.62) ø2438.4 (ø96.00)


1385.4 (54.54)
Generator

Top of Radiators

2451.7 (96.52)
Centerline of
Crankshaft

110.9 (4.37)
Floor Standing Brakes

2087.8
(82.20)

SIDE VIEW
13 440.0 (529.13)

5112.7 (201.29)

3425.2 (134.85)

794.1 (31.26)

Power Package Dimensions


Length 13 440.0 mm 529.13 in Note: Do not use for installation design. See general dimension
Width 4647.7 mm 182.98 in drawings for detail (Drawing # 220-3466).
Height* 5112.7 mm 201.29 in For shipping, steps and exhaust rain cap are not installed.
Approx. weight w/genset 36 363 kg 80,000 lbs
*Height reflects the empty 5000 gallon fuel tank.