Cat 3516B
Cat 3516B
Cat 3516B
3516B
POWER PACKAGE
(Walk-In Sound
Attenuated Enclosure)
FEATURES
The Caterpillar Power Package is bundled with ● Caterpillar dealers fill 99.7% of parts orders
the 3516B 60 Hz, 1800 rpm, 3-phase, 480/227 Volt, within 24 hours
diesel package generator set ● Caterpillar dealers have over 1844 dealer
ENCLOSURE branch stores operating in 166 countries
● The Cat Scheduled Oil Sampling (S•O•SSM )
● Application-engineered airflow to meet cooling
and sound requirements. program cost effectively detects internal engine
component condition, even the presence of
● Roof pitch prevents moisture accumulation
unwanted fluids and combustion by-products
● 43°C (110°F) ambient capability
● Wind load rated to 150 mph
● Roof load rated to 40 psf CAT 3516B TA DIESEL ENGINE
● Reliable, rugged, durable design
● Sound attenuated to provide a four point
● Field-proven in thousands of applications
logarithmic average of 72 dB(A) @ 50 feet
● Built in accordance with UL2200 rainproof worldwide
● Four-stroke-cycle diesel engine combines
designation
● Integrally insulated exhaust silencing system consistent performance and excellent fuel
economy with minimum weight and low
housed within the enclosure for operator safety,
emissions
maximum product life, and additional sound
attenuation
● 5000 gallon double wall, UL 142 Listed, CAT SR4B GENERATOR
closed-top diked, generator base tank with ● Matched to the performance and output
integral lift provisions characteristics of Caterpillar engines
● Compatible with Cat® generator set control ● Optimum winding pitch for minimum total
panel attachments harmonic distortion and maximum efficiency
FULL RANGE OF ATTACHMENTS ● Single point access to accessory connections
● Wide range of bolt-on system expansion ● UL 1446 recognized Class H insulation
attachments, factory designed and tested
SINGLE-SOURCE SUPPLIER CAT CONTROL PANELS
● Fully prototype tested with certified torsional ● Controls designed to meet individual
vibration analysis available customer needs:
EMCP II+ offers full-featured power metering
WORLDWIDE PRODUCT SUPPORT
and protective relaying
● Caterpillar dealers provide extensive post sale
● UL 508A Listed
support including maintenance and repair
agreements
LEHE2482
W H E R E T H E W O R L D T U R N S F O R P O W E R
3 5 1 6 B
P O W E R P A C K A G E
LEHE2482
2
3 5 1 6 B
P O W E R P A C K A G E
SPECIFICATIONS
CAT CONTROL PANELS
CAT SR4B GENERATOR
EMCP II+
Excitation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Permanent Magnet 24 Volt DC Control
Pitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.6666 NEMA 1, IP23 dust proof enclosure
Number of poles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Electronically dead front
Number of bearings . . . . . . . . . . . . . . . . . . . . . . . . . Single Bearing Lockable hinged door
Insulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL 1446 Recognized Generator instruments meet ANSI C-39-1
Class H with tropicalization and antiabrasion Generator terminal box mounted
IP rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Drip Proof IP22 Single location for customer connection
Alignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pilot Shaft UL508A Listed
Overspeed capability — % of rated . . . . . . . . . . . . . . . . . . . . . . 150 Panel illuminating lights
Wave form. . . . . . . . . . . . . . . . . . . . . . . . . . Less than 5% deviation Auto start/stop control
Paralleling kit/Droop transformer . . . . . . . . . . . . . . . . . . Standard Voltage adjustment potentiometer
Voltage regulator . . . 3 Phase sensing with selectable volts/Hz True RMS AC metering, 3-phase
Voltage regulation . . . . . . . . . . . Less than ± 1/2% (steady state) Digital indications for:
Less than ± 1% (no load to full load)
RPM
Telephone Influence Factor. . . . . . . . . . . . . . . . . . . . . Less than 50
Operating hours
Harmonic Distortion . . . . . . . . . . . . . . . . . . . . . . . . . . Less than 5%
Oil pressure
Coolant temperature
CAT DIESEL ENGINE System DC volts
L-L volts, L-N volts, Phase amps, Hz
3516B TA, V-16, 4-stroke-cycle water-cooled diesel
ekW, kVA, kVAR, kWhr, %kW, PF
Bore – mm (in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170 (6.7)
Shutdowns with indicating lights for:
Stroke – mm (in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190 (7.5)
Low oil pressure
Displacement – L (cu in) . . . . . . . . . . . . . . . . . . . . . . 69.06 (4214.3)
High coolant temperature
Compression ratio. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14:1
Low coolant level
Aspiration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TA
Overspeed
Fuel system . . . . . . . . . . . . . . . . . . . . . . . . . . . . Direct unit injection
Emergency stop
Failure to start (overcrank)
Programmable protective relaying functions:
Under and over voltage
Under and over frequency
Reverse power
Overcurrent (phase and total)
Programmable kW level relay
3 Indicator LED’s (programmable for fuel high, low and rupture)
4 spare alarm/shutdown inputs
LEHE2482
3
3 5 1 6 B
P O W E R P A C K A G E
LEHE2482
4
3 5 1 6 B
P O W E R P A C K A G E
TOP VIEW
3302.0 (130.00)
SIDE VIEW/CUTAWAY
Rear Face of Cylinder Block
Top of Radiators
2451.7 (96.52)
Centerline of
Crankshaft
110.9 (4.37)
Floor Standing Brakes
2087.8
(82.20)
SIDE VIEW
13 440.0 (529.13)
5112.7 (201.29)
3425.2 (134.85)
794.1 (31.26)
LEHE2482