ECN/EQN/ERN 400 Series

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

ECN/EQN/ERN 400 series

Absolute and incremental rotary encoders


• Stator coupling for plane surface
• Blind hollow shaft or hollow through shaft

Blind hollow shaft

Connector coding
Hollow through shaft A = axial, R = radial
Flange socket

Cable radial, also usable axially


 = Bearing of mating shaft
 = Measuring point for operating temperature
1 = Clamping screw with X8 hexalobular socket
2 = Compensation of mounting tolerances and thermal expansion; no dynamic motion permitted
3 = Ensure protection against contact (EN 60 529)
4 = Direction of shaft rotation for output signals as per the interface description
1) = Clamping ring on housing side (condition upon delivery)
2) = Clamping ring on coupling side (optionally mountable)
36
Incremental

ERN 420 ERN 460 ERN 430 ERN 480


1)
Interface TTL HTL 1VPP

Line counts* 250 500 –

1000 1024 1250 2000 2048 2500 3600 4096 5000

Reference mark One

Cutoff frequency –3 dB – 180kHz


Output frequency  300 kHz –
Edge separation a  0.39 µs –

System accuracy 1/20 of grating period

Electrical connection* • M23 flange socket, radial and axial (with blind hollow shaft)
• Cable 1 m, without connecting element

Voltage supply DC 5 V ±0.5 V DC 10 V to 30 V DC 10 V to 30 V DC 5 V ±0.5 V

Current consumption 120mA 100mA 150mA 120mA


without load

Shaft* Blind hollow shaft or hollow through shaft; D = 8 mm or D = 12 mm

Mech. permissible speed n2) 6000rpm/12000 rpm3)

Starting At 20 °C Blind hollow shaft:  0.01 Nm


torque Hollow through shaft:  0.025 Nm (for IP66:  0.075 Nm)
Below –20 °C  1 Nm
–6 2
Moment of inertia of rotor 4.3x10 kgm

Permissible axial motion of ±1 mm


measured shaft

Vibration 55 Hz to 2000 Hz  300m/s2;flange socket version:150 m/s2 (EN 60 068-2-6); higher values upon request
Shock 6 ms  2000 m/s2 (EN 60 068-2-27)

Max. operating 100 °C 70 °C 100 °C4)


2)
temperature

Min. operating temp. Flange socket or fixed cable: –40 °C; moving cable: –10 °C

Protection EN 60 529 At housing: IP67 (IP66 with hollow through shaft)


At shaft inlet: IP64 (when D = 12 mm IP66 upon request)

Mass  0.3 kg

Valid for ID 385420-xx 385460-xx 385430-xx 385480-xx5)

Bold: This preferred version is available on short notice.


* Please select when ordering
1)
Restricted tolerances: signal amplitude 0.8 VPP to 1.2 VPP
1)
For the correlation between the operating temperature and the shaft speed or supply voltage, see General mechanical information
3)
With two shaft clamps (only for hollow through shaft)
4)
80 °C for ERN 480 with 4096 or 5000 lines
5)
Mechanical fault exclusion available; for restrictions on specifications and for special mounting information, see the Fault exclusion
customer information document.