Footmotion Plating System en
Footmotion Plating System en
Footmotion Plating System en
FOOTMOTION
PL ATING SYSTEM
Precontoured implants
A complete range of plates for foot
and ankle surgeons
Transfixation screw technology
Reliable compressive technology
FO OT M OT I O N P L AT IN G S Y ST EM
Indications: The Footmotion Plating System is intended for arthrodeses, fractures and osteotomies fixation and revision surgeries of the foot in adults.
Contraindications:
• Serious vascular deterioration, bone devitalization.
• Pregnancy.
• Acute or chronic local or systemic infections.
• Lack of musculo-cutaneous cover, severe vascular deficiency affecting the concerned area.
• Insufficient bone quality preventing a good fixation of the implants into the bone,
• Muscular deficit, neurological deficiency or behavioral disorders, which could submit the implant to abnormal mechanical strains.
• Allergy to one of the materials used or sensitivity to foreign bodies.
• Serious problems of non-compliance, mental or neurological disorders, failure to follow post-operative care recommendations.
• Unstable physical and/or mental condition.
I N N O VA T I O N M E A N S M OT I O N
FO OT M OT I O N P L AT IN G S Y ST EM
Plantar
Features:
(a) - The screw head is stopped in the hole by its cap,
ensuring the locking,
Screw head
cap - The screw head is buried in the plate (a),
- Plate and screws are all made of titanium.
The threads under the screw Coaptation of both profiles during locking, limi-
head and inside the hole have ting the cold welding risk and improving the re-
strictly the same geometrical moval properties.
characteristics.
I N N O VA T I O N M E A N S M OT I O N
A C O MP R EHEN S I V E R A N G E O F P L AT E S
Hole for the transfixation screw: The transfixation screw goes through the 1st MTP joint providing stability to the
assembly.
Transfixation screw
1st MTP joint
CLINICAL CASE:
Example of surgery using a plate for 1st Metatarsophalangeal arthrodesis with transfixation screw.
Left foot showing a 1st MTP The solution: 2 months post operative X-ray.
osteoarthritis. • Plate for 1st MTP arthrodesis
(with transfixation screw),
• Plate reference : FMTGD1
A C O MP R EHEN S I V E R A N G E O F P L AT E S
Technical features:
Technical features:
Technical features:
2 types of
transfixation
screws
I N N O VA T I O N M E A N S M OT I O N
A C O MP R EHEN S I V E R A N G E O F P L AT E S
Technical features:
The transfixation screw is inserted through the joint providing stability to the
assembly.
4 types of plates and 2 types of surgical approaches in order to address
different surgical philosophies.
Precontoured implants.
Plantar positioning of the plate:
• Offers stable assembly and generate dynamic compression, the
transfixation screw is inserted through the joint.
Anatomical implant:
• The narrow plates for plantar lapidus are made of Grade 2 Titanium for an
easier adaptation to first tarsometatarsal (TMT1) joint anatomies when using guide gauges for bending.
Hallux valgus
and ligamentous
hyperlaxity.
A C O MP R EHEN S I V E R A N G E O F P L AT E S
Technical features:
Thickness of 1.6mm,
Transfixation screw,
Precontoured implant.
Technical features:
I N N O VA T I O N M E A N S M OT I O N
A C O MP R EHEN S I V E R A N G E O F P L AT E S
PL ATE FOR TA LO-NAV ICULA R ARTHRODESIS
(Examples of application: osteoarthritis, high-arched foot, equinovarus, flatfoot and traumatic after-
effects)
Technical features:
PLATE
PL ATE FOR OPENING BA
BASE
SE WEDGE
W ED GE METATAR
METATARSS AL OSTEOTOM Y
Technical features:
A wedge is integrated into the plate: the wedge size depends on the correction
angle. 3 sizes are available: 3, 4 and 5 mm + 1 neutral plate.
Low profile plate: 1.4 mm thick.
Converging proximal screws offering stable fixation.
3-in-1 dedicated instrument: Distraction, compression and osteotomies.
ANC642
A C O MP R EHEN S I V E R A N G E O F P L AT E S
PLATE FOR CALCA NE AL DISPLACEMENT OSTEOTOM Y
Technical features:
Technical features:
2 types of plates :
Precontoured plates respecting
• Plates with wedge for osteotomies
• The calcaneal anatomy,
• Plate without wedge for graft addition and cc joint fusion.
• The calcaneo-cuboid joint.
3-in-1 dedicated instruments: Distraction, compression and
Converging screws: allowing a stable fixation of the system.
osteotomies.
ANC642
I N N O VA T I O N M E A N S M OT I O N
A C O MP R EHEN S I V E R A N G E O F P L AT E S
PL ATE FOR COTTON OSTEOTOM Y
Technical features:
Precontoured plates:
respecting the 1st cuneiform anatomy.
Converging screws allowing a stable fixation of the
system.
2 types of plates:
- Plates with wedge for osteotomy,
- Plates without wedge for graft addition.
FMTDDN4 1 st
MTP Arthrodesis plate - Right - Narrow - Size 4 60.5 mm
FMTDD4 1 st
MTP Arthrodesis plate - Right - Size 4 60.4 mm
I N N O VA T I O N M E A N S M OT I O N
IM P L A N TS R EFE R EN CE S
FLTDMV1 Medio plantar Lapidus Arthrodesis plate - Right - Narrow - Size 1 41.8 mm
FLTGMV1 Medio plantar Lapidus Arthrodesis plate - Left - Narrow - Size 1 41.8 mm
STRAIGHT PLATES
I N N O VA T I O N M E A N S M OT I O N
IMP L A N TS R EFE R EN CE S
Ø2.8 MM SCREWS
Ø3.5 MM SCREWS
* Not anodized
IN ST R U M EN TS R EFE R EN CE S
Non-contractual pictures
FOOTMOTION PLATING SYSTEM INSTRUMENTS FOOTMOTION PLATING SYSTEM INSTRUMENTS
ANC568 Ø16 mm concave reamer 1 ANC586 Ø2.0 mm non threaded bent guide gauge for Ø2.8 mm screws 1
ANC569 Ø18 mm convex reamer 1 ANC589 Length gauge for Ø2.8 and Ø3.5 mm screws 1
ANC570 Ø18 mm concave reamer 1 ANC590 Ø2.0 mm quick coupling drill bit - L 125 mm 2
ANC571 Ø20 mm convex reamer 1 ANC591 Ø2.7 mm quick coupling drill bit - L 125 mm 2
ANC572 Ø20 mm concave reamer 1 ANC611 Ø3.0 mm quick coupling drill bit - L 125 mm 1
ANC576 Ø2.0 mm threaded guide gauge for Ø2.8 mm screws 2 33.0216.150 Pin - Ø1.6 L150 mm 5
Brochure EN - Footmotion Plating System - Ed7 - 10/2018 - Medical device EC : class IIb - CE0120 SGS UK - US Class: II - Read labeling and instructions before use.
RACK
(ANC588/R)
BASE (ANC588/B)
ANC588/M2
ANC588/M2 ANC588/M6
ANC588/M1
ANC588/M7
ANC588/M4 ANC588/M8
REMOVAL SET
If you have to remove FOOTMOTION PLATING SYSTEM implants, make sure to order the Newclip Technics removal set which includes the following
instruments:
- ANC350: Ø4.5 mm AO quick coupling handle - Size 1.
- ANC575: T8 quick coupling screwdriver
The information presented in this brochure is intended to demonstrate a NEWCLIP TECHNICS product. Always refer to the package insert, product label and/or user instructions
before using any NEWCLIP TECHNICS product. Surgeons must always rely on their own clinical judgment when deciding which products and techniques to use with their patients.
Products may not be available in all markets. Product availability is subject to the regulatory or medical practices that govern individual markets. Please contact your NEWCLIP
TECHNICS representative if you have questions about the availability of NEWCLIP TECHNICS products in your area.
NEWCLIP TECHNICS NEWCLIP USA NEWCLIP TECHNICS GmbH NEWCLIP TECHNICS Australia
PA de la Lande Saint Martin - 45 rue des Garottières 642 Larkfield Center , Pröllstraß 11, Forest Central Business Park
44115 Haute Goulaine (France) Santa Rosa CA 95403, USA D-86157 Augsburg, Deutschland Building 10 Level 1, 49 Frenchs Forest
Tél. : +33 (0)2 28 21 23 25 - Fax : +33 (0)2 40 63 68 37 Phone : + 1 707 230 5078 Phone : +49 (0)821 650 749 40 Rd, Frenchs Forest 2086, Australia
orders@newcliptechnics.com customerservice@newclipusa.com info@newclipgmbh.com Phone: +61 (0)2 81 886 110
www.newcliptechnics.com www.newclipusa.com www.newclipgmbh.de solutions@newclipaustralia.com
www.newcliptechnics.com