High Wall Unit: 42KHF / 42QHF
High Wall Unit: 42KHF / 42QHF
High Wall Unit: 42KHF / 42QHF
PRODUCT SPECIFICATIONS
Fan Coil Unit (Indoor) UNIT COOL ONLY HEAT PUMP
Model Number 42KHF012H 42KHF018H 42KHF024H 42KHF030H 42QHF012H 42QHF018H 42QHF024H 42QHF030H
Unit Size 1.0 1.5 2.0 2.5 1.5 2.0 2.5 3.0
Rating Capacity Cooling BTU/h 11500 17500 24000 29000 11500 17500 24000 29000
at T1 Condition Heating kW - - - - 3300 5300 7500 8400
Total Power Input Cooling Watts 950 1,460 2,000 2,480 940 1,470 2,000 2,370
(Indoor + Outdoor) AIR CONDITIONING SOLUTIONS
Heating Watts - - - - 1000 1500 2240 2300
EER Btu/W-h 12.105 11.986 12.000 11.694 12.234 11.905 12.000 12.236
Total Current Draw Cooling A 4.2 6.5 8.7 10.8 4.2 6.4 8.8 10.4
(Indoor + Outdoor) Heating A - - - - 4.5 6.7 9.8 10.2
Liquid inch 1/4" 1/4" 3/8" 3/8" 1/4" 1/4" 3/8" 3/8"
Pipe
Suction inch 1/2" 1/2" 3/4" 3/4" 1/2" 1/2" 3/4" 3/4"
Connection Size
Drain inch 5/8'' 5/8'' 5/8'' 5/8'' 5/8'' 5/8'' 5/8'' 5/8''
Model Number 38KHF012H 38KHF018H 38KHF024H 38KHF030H 38QHF012H 38QHF018H 38QHF024H 38QHF030H
Compressor Type ROTARY ROTARY ROTARY ROTARY ROTARY ROTARY ROTARY ROTARY
Pipe Liquid inch 1/4" 1/4" 3/8" 3/8" 1/4" 1/4" 3/8" 3/8"
Connection Size Suction inch 1/2" 1/2" 3/4" 3/4" 1/2" 1/2" 3/4" 3/4"
Recommended Wire Size/
No. of Wires for Power mm²/qty 1.5/3 2.5/3 2.5/3 2.5/3 1.5/3 2.5/3 2.5/3 2.5/3
Supply to Condensing Unit
Recommended Wire Size/
No. of Wires for Control from mm²/qty 1.5/3 2.5/3 2.5/4 2.5/4 1.5/5 2.5/5 2.5/4 2.5/4
FCU to Condensing Unit
Dimensions (W x D x H) mm 780x250x540 845x320x700 945x395x810 945x395x810 780x250x540 845x320x700 945x395x810 945x395x810
Cooling capacity is based on following condition: indoor air temperatures 27°C (DB) / 19°C (WB) and outdoor air temperatures 35°C (DB) / 24°C (WB).
We reserve the right to change features and/or specifications without notice and without incurring any liability.
ﻳﻘــﻮم ﻣﻜﻴــﻒ اﻟﻬــﻮاء،ﻋﻨــﺪ ﺗﻤﻜﻴــﻦ ﻫــﺬه اﻟﻮﻇﻴﻔــﺔ ﻳﻤﻜــﻦ ﺿﺒــﻂ اﻟﺸــﻔﺮات ﻋــﻦ ﻃﺮﻳــﻖ ﺟﻬــﺎز اﻟﺘﺤﻜــﻢ ﻋــﻦ
ﺑﺮﻓــﻊ اﻟﺤــﺪ اﻷﻗﺼــﻰ ﻟﻨﺎﺗــﺞ اﻟﺘﺒﺮﻳــﺪ أو اﻟﻘــﺪرة ﻋﻠــﻰ ﺑﻌــﺪ )اﻟﺮﻳﻤــﻮت ﻛﻨﺘــﺮول( أو ﻳﺪوﻳــﺎ ﺑﺤﻴــﺚ ﻳﺘــﻢ ﺗﻮزﻳــﻊ Compound filter Self-diagnosis function
اﻟﺘﺪﻓﺌــﺔ ﻣﻤــﺎ ﻳــﺆدي إﻟــﻰ ﺗﺒﺮﻳــﺪ اﻟﻐﺮﻓــﺔ وﺗﺪﻓﺌﺘﻬــﺎ .اﻟﻬــﻮاء ﺑﺸــﻜﻞ اﻓﻀــﻞ ﻓــﻲ أرﺑــﻊ اﺗﺠﺎﻫــﺎت ﻣﺠﻤﻮﻋﺔ اﻟﻔﻼﺗﺮ وﻇﻴﻔﺔ اﻟﺘﺸﺨﻴﺺ اﻟﺬاﺗﻲ
ﺑﺸــﻜﻞ ﺳــﺮﻳﻊ وﺑﻠــﻮغ درﺟــﺔ اﻟﺤــﺮارة اﻟﻤﻄﻠﻮﺑــﺔ ﻓــﻲ
.أﻗﺼــﺮ وﻗــﺖ ﻣﻤﻜــﻦ Combines three filters from eight different In the event of any abnormal operation or
types including cold catalyst filter, vitamin C parts failure, the unit will shut off automatically
filter, multifunction filter to meet various needs to protect the system. Meanwhile it will
Sleep mode Follow me function simultaneously and improve internal air quality indicate a protection or error code indicating