The basic function of a VSC is to
VOLTAGE SOURCE CONVERTERS convert the DC voltage of the capacitor into
FOR HVDC AC voltages. Fig 2 illustrates the basic
The world of converters may be operating principle. The polarity of the DC
divided in to two groups that are to be voltage of the converter is defined by the
distinguished by their operational principle. polarity of the diode rectifier. The IGBT can
One group needs an AC system to be switched on at any time by appropriate
operate and called as line commutated gate voltages. However if one IGBT of a
coverters.Conventional HVDC systems branch is switched on, the other IGBT must
employ line commutated converters. have been switched off before to prevent a
The second group of converters does short circuit of storage capacitor. Reliable
not need an AC system to operate and is storage converter inter lock function will
therefore called as self commutated preclude unwanted switching IGBT.
converters. Depending on the design of the Alternating switching the IGBT’s of one
DC circuits this group can be further divided phase module as shown successively
in to current source converters and connects the AC terminals of the VSC to the
voltage source converters. A current source positive tapping and negative tapping of the
converter operates with a smooth DC current DC capacitor. This results in a stair stepped
provided by a reactor, while a VSC operates AC voltage comprising two voltage levels
with a smooth DC voltage provided by +Vdc/2 and -Vdc/2. A VSC as shown is
storage capacitor. Among the self there fore called a 2 level converter.
commutated converters it is especially the The VSC based HVDC transmission system
VSC that has big history in the lower power mainly consists of two converter stations
range for industrial drive applications. connected by a dc cable. Usually the
Diagrammatic Representation of VSC-HVDC magnitude of AC output voltage of
BASIC WORKING PRINCIPLE converter is controlled by Pulse width
modulation (PWM) without changing the
magnitude of DC voltage.
2
being coupled to a respective power
generator station. The converter, having
an AC side and a DC side, includes a
bridge of semiconductor switches with
gate turn-off capability coupled to a
control system to produce a bridge
voltage waveform having a fundamental
Fourier component at the frequency of
the electric network coupled to the AC
side of the converter. The control system
includes three inputs for receiving reference
Due to switching frequency, that is
signals allowing to control the frequency,
considerably higher than the AC system
the amplitude and the phase angle of the
power frequency the wave shape of the
fundamental Fourier component with respect
converter AC current will be controlled to
to the alternating voltage of the network
vary sinusoidal. This is achieved by special
coupled to the AC side of the converter.
Pulse Width Modulation. Besides the 2
Through appropriate feedback loops, the
level converters, so called 3 level converters
converter may be used to maintain at a
have been used for high power applications.
predetermined level the power flowing there
A three level VSC provides
through or to keep at a preset value the
significant better performance regarding the
voltage across the DC terminals of the
total harmonic voltage distortion
converter and, in both cases, to maintain the
(THD).However, the more complex
frequency synchronism between the
converter layout resulting in the larger
fundamental Fourier component and the
footprint and higher investment costs makes
alternating voltage of the network coupled to
2 level technology the preferred solution for
the DC side of the converter.
HVDC from today’s point of view
PULSE WIDTH MODULATION
A converter for interconnecting two electric
networks to transmit electric power from
one network to the other, each network
3
with an angle of 80 degrees at fundamental
frequency (50 Hz) and at the third harmonic.
The VSC converters are three-level bridge
blocks using close to ideal switching device
model of IGBT/diodes. The relative ease
with which the IGBT can be controlled and
its suitability for high-frequency switching
has made this device the better choice over
The principal characteristic of VSC- Station 2 subsystems to see how they are
polarity of the DC link voltage remains the connected. In a simplified manner, from the
same with the DC current being reversed to AC system, a VSC can be considered a
4
on AC and DC side. Characteristic AC side Possibility to use robust and
harmonics will have the ordinal numbers economically extruded cables for
Vac =12n+1; n=1, 2……… both land and sea.
Characteristic DC harmonics will have Small converters that reduce the
the ordinal numbers requirement for space.
Vdc=12n; n=1, 2………..
All harmonics will be cancelled out VSC based HVDC does not add
under ideal conditions. short circuit power, so there is a
Due to its inherent harmonic elimination great freedom in choice of topology
capability, the harmonic interface of VSC and interconnection points.
converter is rather small in comparison to A substantial reduction in system
the conventional line commutated losses, mainly due to the elimination
converters.However, harmonic filters might of the transformer and related
be necessary on the AC and DC sides equipment. Losses could be reduced
depending on the harmonic performance by up to 25%.
requirements both for AC and DC sides, AC Other environmental benefit, e.g. the
system harmonic impedance, DC line/cable new motor is epoxy-free and
impedance and loss evaluation therefore easy to recycle.
VSC HVDC has the following advantages APPLICATION’S OF HVDC
No need for short circuit power for TRANSMISSION USING VSC
commutation. Can even operate HVDC Light is a recent technology
against black Networks. that utilizes Voltage Source Converters
Can operate without communication (VSC) rather than line commutated
between stations. converters. HVDC Light offers advantages
Can operate to control the power due to the possibility to independently
continuously in one direction. control both active and reactive power
No change of Voltage polarity when HVDC Light employs Insulated Gate
the power direction is changed. This Bipolar transistors (IGBTs), plus other
makes easier to make multi-terminal important technological developments:
schemes.
5
High voltage valves with series-
connected IGBTs
Compact, dry, high-voltage dc
capacitors
High capacity control system
Solid dielectric DC cable
In the HVDC Light transmission
schemes, the switching of the IGBT valves
follows a pulse width modulation (PWM)
pattern. This switching control allows
simultaneous adjustment of the amplitude
and phase angle of the converter AC output
voltage with constant dc, PWM pattern and
the fundamental frequency voltage in a
Voltage Source Converter. With these two
independent control variables, separate
active and reactive power control loops can
be used for regulation. With these two
independent control variables, separate
active and reactive power control loops can
be used for regulation.
MAIN DIFFERENCES BETWEEN
HVDC LIGHT AND CONVENTIONAL
6
7