Delta Vector Control Drive C2000 Series: Automation For A Changing World
Delta Vector Control Drive C2000 Series: Automation For A Changing World
Delta Vector Control Drive C2000 Series: Automation For A Changing World
w w w. d e l t a w w. c o m
Powerful Features.
High Efficiency.
The C2000 Series AC motor drive provides the most efficient solution for all
types of drive applications. It features precise speed, torque and position
control functions that are suitable for both sensor and sensorless types
of synchronous and asynchronous motors. The C2000 Series is also equipped
with built-in PLC functions and supports the CANopen Master/Slave extension
for the ultimate in system flexibility and fast data exchange.
1
Table of Contents
Standard Models 3
Modular Design 5
Certifications 6
LCD Keypad 7
Specifications 13
Wiring
Dimensions
Option cards
Ordering information
2
Standard Models (IP20/NEMA1)
Power range:230 V 0.75 ~ 90 kW
230 V (kW) 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90
230 V (HP) 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125
Frame Size A B C D E F
▪▪ Environmental Adaptability
1. 50℃ operating temperature
2. Built-in DC reactor
3. Coated circuit boards
4. Built-in EMC filter
5. International safety standard
(CE/UL/cUL)
*Note: Please refer to the Product Specification
3
90 110 132 160 185 220 280 315 355 450
125 150 175 215 250 300 375 425 475 600
E F G H
560 630
745 840
▪▪ Modular Design
1. Hot pluggable LCD keypad
2. I/O extension cards
3. Various PG (encoder) feedback cards
4. Network cards for fieldbus modules
5. Removable fan
4
Modular Design
Various accessories options, such as I/O extension cards, encoder feedback cards, communication cards,
hot pluggable LCD keypad, removable terminals and removable fans.
►► I/O extension cards
EMC-D611A EMC-D42A
►► PG (Encoder) cards
EMC-PG01O / EMC-PG02O
EMC-A22A
EMC-PG01U / EMC-PG02U
►► 24V Power
Shift Card
EMC-BPS01
►► Relay Extension
Card
EMC-PG01L / EMC-PG02L
EMC-R6AA
EMC-PG01R
►► Communication cards
CMC-PD01 CMC-DN01
■■ Removable fan
CMC-MOD01 / CMC-EIP01 EMC-COP01
To ensure personal safety,
do not begin wiring before *NOTE: "u" are optional accessories.
the indicator light is off.
■■ Power indicator
To prevent personal injury, please do not
perform wiring before power indicator is off.
CMC-EC01
■■ Removable terminals
Convenient wiring and safety equipment.
Dual RJ45
Analog I/O switch Termination resistor communication ports
5
The modular design fulfills the needs of system applications and equipment maintenance.
Certifications
UL, cUL CE
Low Voltage: EN61800-5-1
C-Tick EMC: EN61000-3-12, EN61800-3, IEC61000-6-2, IEC61000-6-4, IEC61000-4-2,
IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8
ROHS
6
Quick and Easy Parameters Setting via the
LCD Keypad
■■ Multi-column display for the drive status
■■ Simple and intuitive operation
■■ User-defined parameter groups
■■ Real Time Clock and calendar function
F1 to F4: User-defined
■■ Language selection for display function keys
■■ Copy function saves parameters and PLC
programs to the keypad memory for later
Selection keys
transfer to another drive
■■ IP66 protection level
LED displays the
current drive status
7
High-Speed Network
►► Provides optional MODBUS RTU and various ►► Advanced network functions
fieldbus cards for flexible applications ►► Built-in MODBUS communication
■■
■■ CANopen (DS402)
Ability to control up to 8 Slave drives via the CANopen Master function
• Supports all Delta industrial automation products
(Built-in EDS files for all Delta industrial automation products) • TAP-CN03 distribution
• I/O data configurations for each device on the CANopen network
box for long distances
• Motion control planning function
• WPL Soft
CANopen CANopen
• RJ45 cable
1 Mbps 25 m
500 kbps 100 m
■■ DeviceNet ■■ EtherNet/IP
Through the Delta specially designed DeviceNet ■■ MODBUS TCP
Builder software, users can easily establish
Delta provides communication integrator software
a standard DeviceNet control network by the
that offers graphic module settings and a user friendly
parameter pre-assignment function for each
interface to support all Ethernet products settings and
equipment and remote I/O.
online monitoring.
• Supports all Delta industrial automation products
• Delta software for Ethernet/MODBUS TCP products
(Built-in EDS files for all Delta industrial automation
products) • Graphic module settings and a user friendly interface
• I/O data configurations • Auto search function
for each device on the
• Supports Virtual
DeviceNet network
COM settings
• DeviceNet layout software
Start-up display
Displays horsepower, rated voltage and current of the drive in use.
Parameter management
Provides parameter setting/save/copy/comparison for
convenient parameter management.
Trend records
Monitors the drive operation form via network and
displays I/O terminal status. Useful for tasks such as
"trial run monitoring".
Quick setup
Guides the user step-by-step through the drive
settings according to quick setup wizard.
*NOTE: These software programs are available for download on Delta's website
8
High-Performance Field Oriented Control
The FOC+PG mode of C2000 Series can output 150% Precise position and speed control ideal for printing
of starting torque at extremely low speeds for precise machine applications.
and stable speed control.
0.1Hz
250
0.5Hz
200
1Hz
Torque(%)
150 2Hz
3Hz
100
5Hz
50
10Hz
0 -1 1 3 5 7 9 11
Frequency(Hz)
0
-20
-40
Output Current
-60
-80 Current < Rated Current * 0.35
-100
100 150 200 250 300 350 400 450 500
Time 5sec
DEB DEB
Decelerate to Stop DEB Return Time Decelerate to Stop DEB Return Time
Time Time
9
A Drive for Permanent Magnet
(PM) Motors
The C2000 is a dual mode drive to control
Encoder
both an induction motor and permanent
Counter
magnet motor. The dynamic response
of a PM motor provides precise
control of position, speed
and torque.
Permanent magnet motor
Mains
Power M
AC Voltage
DC Voltage
Mains
Power M
AC Voltage
DC Voltage
10
Delta Active Front End AFE2000 Series
Features
■■ Replaces traditional brake resistor to reduce heat generation.
■■ Clear energy savings: more than 95% of the
regenerative energy is converted into electricity
and supplied back to the mains.
■■ Full-load operation: input-side current THD lower than
5% and improves power factor up to 99%.
■■ AC motor drives with AFE2000:
supports 4-quadrant operation with variable
frequencies and adjustable system.
■■ Constant DC bus voltage: unaffected
by mains voltage fluctuations.
60%
Applications
■■ Large-inertia loads, such as centrifuge equipment, dewatering machines and roving machines
■■ 4-quadrant loads including elevators, cranes and pumpjacks (oil extraction machines)
■■ Quick braking, such as machine tools, bag making machines, auto storage and retrieval systems, and lathes
■■ Long-term energy feedback, such as wind power, water power, steel printing and paper making machinery (winding
equipment)
■■ Improves power quality for industries such as semiconductor and panel industries
11
Operation Temperature and Protection Level
Model Frame Top Cover Conduit Box Protection Level OperationTemperature
VFDxxxCxxA IP00
VFDxxxCxxS IP20 / UL Open Type
Frame D ~ H
230 V: > 22 kW N/A No conduit box -10 ºC ~ 50 ºC
460 V: > 30 kW
Frame D ~ H
VFDxxxC63B-21 N/A Standard conduit box IP20 / UL Type1 / NEMA1 -10 ºC ~ 40 ºC
> 45 kW
IP00
IP20 / UL Open Type
Frame D ~ H
VFDxxxC63B-00 N/A No conduit box -10 ºC ~ 50 ºC
> 45 kW
Protection degree for
the circled area is IP00,
other areas are IP20
12
Environment for Operation, Storage and
Transportation
DO NOT expose the AC motor drive to harsh environments, such as dust, direct sunlight, corrosive / flammable gasses, humidity, liquid or vibrations.
The salts in the air must be less than 0.01 mg / cm2 per year.
Installation Location IEC60364-1 / IEC60664-1 Pollution degree 2, indoor use only
Transportation 70 ~ 106
IEC60721-3-3
Operation Class 3C3; Class 3S2
Storage Class 1C2; Class 1S2
Pollution Level
Transportation Class 2C2; Class 2S2
If the AC motor drive is to be used under harsh environment with high level of contamination (e.g. dew, water, dust), make
sure it is installed in an environment qualified for IP54 such as in a cabinet.
If the AC motor drive is installed at an altitude 0 ~ 1000 m, follow normal operation
restriction. If it is installed at altitude 1000 ~ 2000 m, decrease 1% of rated current or lower 0.5 °C
Altitude Operation
of temperature for every 100 m increase in altitude. Maximum altitude for Corner Grounded TN
system is 2000m, for application over 2000m please contact Delta for more details.
Package Drop Storage / Transportation ISTA procedure 1 A (according to weight) IEC60068-2-31
1.0 mm, peak to peak value range from 2 Hz to 13.2 Hz; 0.7 G ~ 1.0 G range from 13.2 Hz to 55 Hz;
Vibration 1.0 G range from 55 Hz to 512 Hz. Comply with IEC 60068-2-6.
Impact IEC / EN 60068-2-27
Specifications
230 V
Frame Size A B C D E F
Model VFD- ���C�� 007 015 022 037 055 075 110 150 185 220 300 370 450 550 750 900
Rated Output Capacity (kVA) 2.0 3.2 4.4 6.8 10 13 20 26 30 36 48 58 72 86 102 138
Rated Output Current (A) 5 8 11 17 25 33 49 65 75 90 120 146 180 215 255 346
NORMAL DUTY
Applicable Motor Output (kW) 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90
Applicable Motor Output (HP) 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 120
Output Rating *
Overload Capacity 120% of rated current: 1 minute for every 5 minutes; 160% of rated current: 3 seconds for every 30 seconds
Max. Output Frequency (Hz) 0.00 ~ 599.00
Carrier Frequency (kHz) 2 ~ 15 (default setting 8) 2 ~ 10 (default setting 6) 2 ~ 9 (default setting 4)
Rated Output Capacity (kVA) 1.9 2.8 4.0 6.4 9.6 12 19 25 28 34 45 55 68 81 96 131
Rated Output Current (A) 4.8 7.1 10 16 24 31 47 62 71 86 114 139 171 204 242 329
HEAVY DUTY
Applicable Motor Output (kW) 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 19 22 30 37 45 55 75
Applicable Motor Output (HP) 0.5 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100
Overload Capacity 150% of rated current: 1 minute for every 5 minutes; 180% of rated current: 3 seconds for every 30 seconds
Max. Output Frequency (Hz) 0.00 ~ 300.00
Carrier Frequency (kHz) 2 ~ 6 (default setting 2)
Normal Duty 6.4 12 16 20 28 36 52 72 83 99 124 143 171 206 245 331
Input Rating
13
460 V
Frame Size A B C
Model VFD-���C�� 007 015 022 037 040 055 075 110 150 185 220 300
Rated Output Capacity (kVA) 2.4 3.2 4.8 7.2 8.4 10 14 19 25 30 36 48
Rated Output Current (A) 3.0 4.0 6.0 9.0 10.5 12 18 24 32 38 45 60
NORMAL DUTY
Applicable Motor Output (kW) 0.75 1.5 2.2 3.7 4.0 5.5 7.5 11 15 18.5 22 30
Applicable Motor Output (HP) 1 2 3 5 5 7.5 10 15 20 25 30 40
Output Rating *
Overload Capacity 120% of rated current: 1 minute for every 5 minutes; 160% of rated current: 3 seconds for every 30 seconds
Max. Output Frequency (Hz) 0.00 ~ 599.00
Carrier Frequency (kHz) 2 ~ 15 (default setting 8) 2 ~ 10 (default setting 6)
Rated Output Capacity (kVA) 2.3 3.0 4.5 6.5 7.6 9.6 14 18 24 29 34 45
Rated Output Current (A) 2.9 3.8 5.7 8.1 9.5 11 17 23 30 36 43 57
HEAVY DUTY
Applicable Motor Output (kW) 0.4 0.75 1.5 2.2 3.7 4.0 5.5 7.5 11 15 18.5 22
Applicable Motor Output (HP) 0.5 1 2 3 5 5 7.5 10 15 20 25 30
Overload Capacity 150% of rated current: 1 minute for every 5 minutes; 180% of rated current: 3 seconds for every 30 seconds
Max. Output Frequency (Hz) 0.00 ~ 300.00
Carrier Frequency (kHz) 2 ~ 6 (default setting 2)
Normal Duty 4.3 5.9 8.7 14 15.5 17 20 26 35 40 47 63
Input Rating
460 V
Frame Size D0 D E F G H
Model VFD-���C�� 370 450 550 750 900 1100 1320 1600 1850 2200 2800 3150 3550 4500
Rated Output Capacity (kVA) 58 73 88 120 143 175 207 247 295 367 438 491 544 720
Rated Output Current (A) 73 91 110 150 180 220 260 310 370 460 550 616 683 866
NORMAL DUTY
Applicable Motor Output (kW) 37 45 55 75 90 110 132 160 185 220 280 315 355 450
Applicable Motor Output (HP) 50 60 75 100 125 150 175 215 250 300 375 420 475 600
Overload Capacity 120% of rated current: 1 minute for every 5 minutes; 160% of rated current: 3 seconds for every 30 seconds
Output Rating *
Applicable Motor Output (kW) 30 37 45 55 75 90 110 132 160 185 220 280 315 355
Applicable Motor Output (HP) 40 53 60 75 100 125 150 175 215 250 300 375 425 475
Overload Capacity 150% of rated current: 1 minute for every 5 minutes; 180% of rated current: 3 seconds for every 30 seconds
Max. Output Frequency (Hz) 0.00 ~ 300.00
Carrier Frequency (kHz) 2 ~ 6 (default setting 2)
Normal Duty 74 101 114 157 167 207 240 300 380 400 494 555 625 866
Input Rating
NOTES
1) The carrier frequency is default. Increasing the carrier frequency requires a reduction in current. please refer to Pr. 06-55 Derating Protection drawing.
2) The AC motor drive should operate in derating current when its control method is set to FOC Sensorless, TQC+PG, TQC sensorless. PM+PG, PM sensorless. Please refer to Pr. 06-55 for more information.
3) Select the AC motor drive with capacity one grade larger for the impact load application.
4) The rated input current will be affected not only by Power Transformer and the connection of the reactors on input side, but also fluctuates with the impedance of power side.
5) For Frame A, B and C, Model VFDXXXC43A is under IP20 / NEMA1 / UL TYPE1 protection level.
6) For Frame D and above, if the last character of the model is A then it is under IP20 protection level but the wiring terminal is under IP00 protection level;
7) if the last character of the model is E, it is under IP20 / NEMA1 / UL TYPE1 protection level.
14
575 V
Frame Size A B
Model VFD-���C53A-21 015 022 037 055 075 110 150
Rated Output Capacity (kVA) 3 4.3 6.7 9.9 12.1 18.7 24.1
Heavy Duty Normal Duty Light Duty
Rated Output Current (A) 3 4.3 6.7 9.9 12.1 18.7 24.2
Applicable Motor Output (kW) 1.5 2.2 3.7 5.5 7.5 11 15
Applicable Motor Output (HP) 2 3 5 7.5 10 15 20
Rated Output Capacity (kVA) 2.5 3.6 5.5 8.2 10 15.4 19.9
Rated Output Current (A) 2.5 3.6 5.5 8.2 10 15.5 20
Output *
Applicable Motor Output (kW) 0.75 1.5 2.2 3.7 5.5 7.5 11
Applicable Motor Output (HP) 1 2 3 5 7.5 10 15
Rated Output Capacity (kVA) 2.1 3 4.6 6.9 8.3 12.9 16.7
Rated Output Current (A) 2.1 3 4.6 6.9 8.3 13 16.8
Applicable Motor Output (kW) 0.75 1.5 2.2 3.7 3.7 7.5 7.5
Applicable Motor Output (HP) 1 2 3 5 5 10 10
Carrier Frequency (kHz) 2 ~15 (default setting 4)
Light Duty 3.8 5.4 10.4 14.9 16.9 21.3 26.3
Input Current (A) Normal Duty 3.1 4.5 7.2 12.3 15 18 22.8
Input
690 V
Frame Size C D E
Model VFD-���C63B-00 / -21 185 220 300 370 450 550 750 900 1100 1320
Rated Output Capacity (kVA) 29 36 43 54 65 80 103 124 149 179
Light Duty
15
690 V
Frame Size F G H
Model VFD-���C63B-00 / -21 1600 2000 2500 3150 4000 4500 5600 6300
Rated Output Capacity (kVA) 215 263 347 418 494.5 534.7 678.5 776
Light Duty
Applicable Motor Output ( 690V, kW) 160 200 250 315 400 450 560 630
Applicable Motor Output ( 690V, HP) 215 270 335 425 530 600 745 850
Applicable Motor Output (575V, HP) 175 200 250 350 400 450 500 745
Rated Output Current (A) 180 220 290 350 430 465 590 675
Rated Output Capacity (kVA) 179 215 239 347 402.5 442.7 534.7 776
Normal Duty
Applicable Motor Output ( 690V, kW) 132 160 200 250 315 355 450 630
Output *
Applicable Motor Output ( 690V, HP) 175 215 270 335 425 475 600 850
Applicable Motor Output (575V, HP) 150 175 200 250 350 400 450 745
Rated Output Current (A) 150 180 220 290 350 385 465 675
Rated Output Capacity (kVA) 149 179 215 263 333.5 356.5 483 776
Heavy Duty
Applicable Motor Output ( 690V, kW) 110 132 160 200 250 280 400 630
Applicable Motor Output ( 690V, HP) 150 175 215 270 335 375 530 850
Applicable Motor Output (575V, HP) 125 150 175 200 250 335 450 745
Rated Output Current (A) 125 150 180 220 290 310 420 675
Carrier Frequency (kHz) 2 ~ 9 (default setting 4) 2 ~ 9 (default setting 3)
Light Duty 178 217 292 353 454 469 595 681
Input Current (A)
Normal Duty 148 178 222 292 353 388 504 681
Input
Heavy Duty 123 148 181 222 292 313 423 681
Rated Voltage / Frequency 3-Phase 525 VAC ~ 690 VAC ( -15% ~ +10%), 50 / 60 Hz
Operating Voltage Range 446 ~ 759 VAC
Frequency Tolerance 47 ~ 63 Hz
Efficiency (%) 97 98
Power Factor > 0.98
AC Drive Weight (Kg) 88 ± 1.5 135 ± 4 243 ± 5
Cooling Method Fan cooling
Braking Chopper Frame D and above (optional)
DC Choke Frame D and above (built-in)
EMC Filter Optional
* Parameter 00-16; available load modes: Light Duty (LD), Normal Duty (ND) and Heavy Duty (HD); default setting is LD mode
16
General Specifications
Control Method Pulse Width Modulated (PWM)
230 V / 460 V model:
1: V / F,2: SVC,3: VF+PG,4: FOC+PG,5: TQC+PG,6: PM+PG,7: FOC sensorless,8: TQC sensorless,
Control Mode 9: PM sensorless
575 V / 690 V model:
1: V / F,2: V / F+PG,3: SVC
Starting Torque Reach up to 150% or above at 0.5 Hz. Under FOC+PG mode, starting torque can reach 150% at 0 Hz
V / F Curve 4-point adjustable V / F curve and square curve
Speed Response Ability 5 Hz (vector control can reach up to 40 Hz)
230 V / 460 V model: Normal duty 160%, heavy duty 180% of torque current;
Torque Limit
575 V / 690 V model: Maximum 200% of torque current
TQC + PG:±5%
Torque Accuracy at TQC Mode
TQC Sensorless:±15%
Max. Output Frequency (Hz) Light Duty / Normal duty: 0.01 ~ 599.00 Hz; Heavy duty: 0.00 ~ 300.00 Hz
Frequency Output Accuracy Digital command: ±0.01%, -10 ° C ~ +40 ° C, Analog command: ±0.1%, 25 ±10 ° C
Output Frequency Resolution Digital command: 0.01 Hz, Analog command: 0.03 * max. output frequency / 60 Hz (±11 bit)
Control Characteristics
230 V / 460 V model: Over-current protection for 240% of rated current (Normal duty)
Current clamp (Normal duty: around 170 ~ 175%); (Heavy duty: around 180 ~ 185%)
Over-current Protection
575 V / 690 V model: Over-current protection for 225% rated current (Normal duty)
Protection Characteristics
Current clamp (Light duty: around 128 ~ 141%); (Normal duty: around 170 ~ 175%);
(Heavy duty: around 202% ~ 210%)
The C2000 Series will shut down under below conditions:
Over-Voltage Protection
230 V: DC bus over 410 V; 460 V: DC bus over 820 V; 575 V / 690 V: DC bus over 1189 V
Over-Temperature Protection Built-in temperature sensor
Stall Prevention Stall prevention during acceleration, deceleration and running independently
Restart after Instantaneous
Parameter setting up to 20 seconds
Power Failure
Grounding Leakage Current
Leakage current is higher than 50% of rated current of the AC motor drive
Protection
Per UL508C, the drive is suitable for use on a circuit capable of delivering not more than 100kA symmetrical
Short-circuit Current Rating (SCCR)
amperes (rms) when protected by fuses given in the fuse table
International Certifications
17
Wiring
Wiring Diagram for Frame A ~ C
*Input: 3-phase power
NOTE
It is not recommended to use a power capacitor or automatic power factor regulator (APFR) at the power input side. If the system requires such a device, please
make sure a reactor is installed between the drive and the power capacitor or APFR.
18
Wiring Diagram for Frame D ~ F
*Input: 3-phase power
19
Wiring Diagram for Frame G ~ H
*Input: 3-phase power
NOTE
It is not recommended to use a power capacitor or automatic power factor regulator (APFR) at the power input side. If the system requires such a device, please
make sure a reactor is installed between the drive and the power capacitor or APFR.
20
Dimensions
Digital Keypad Unit: mm [inch]
標準LCD操作面板 選購品LCD操作面板
Frame A
MODEL
FRAME_A
VFD007C23A
VFD015C23A
VFD022C23A
VFD037C23A
VFD007C43A / 43E
VFD015C43A / 43E
VFD022C43A / 43E
VFD037C43A / 43E
VFD040C43A / 43E
VFD055C43A / 43E
VFD015C53A-21
VFD022C53A-21
VFD037C53A-21
Frame W H D W1 H1 D1* Ø Ø1 Ø2 Ø3
mm 130.0 250.0 170.0 116.0 236.0 45.8 6.2 22.2 34.0 28.0
A1
inch 5.12 9.84 6.69 4.57 9.29 1.80 0.24 0.87 1.34 1.10
*D1: Flange mount.
21
Frame B
See Detail A
MODEL
VFD075C23A
VFD110C23A
VFD075C43A / 43E
VFD110C43A / 43E
VFD150C43A / 43E Detail A (Mounting Hole)
VFD055C53A-21
VFD075C53A-21
VFD110C53A-21
VFD150C53A-21
Detail B (Mounting Hole)
Frame W H D W1 H1 D1* S1 Ø1 Ø2 Ø3
mm 190.0 320.0 190.0 173.0 303.0 77.9 8.5 22.2 34.0 28.0
B1
inch 7.48 12.60 7.48 6.81 11.93 3.07 0.33 0.87 1.34 1.10
*D1: Flange mount.
MODEL
VFD185C23A
VFD220C23A
VFD185C43A / 43E
VFD220C43A / 43E
VFD300C43A / 43E Detail A (Mounting Hole)
VFD185C63B-21
VFD220C63B-21
VFD300C63B-21
VFD370C63B-21
Detail B (Mounting Hole)
Frame W H D W1 H1 D1* S1 Ø1 Ø2 Ø3
mm 250.0 400.0 210.0 231.0 381.0 92.9 8.5 22.2 34.0 50.0
C1
inch 9.84 15.75 8.27 9.09 15.00 3.66 0.33 0.87 1.34 1.97
*D1: Flange mount.
22
Frame D
D
W SEE DETAIL A D1
W1 D2
SEE DETAIL B S2
S1 S1
DETAIL A DETAIL B
(MOUNTING HOLE) (MOUNTING HOLE)
MODEL
FRAME_D1 FRAME_D0-1
VFD300C23A VFD370C43S
VFD370C23A VFD450C43S
VFD550C43A
VFD750C43A
VFD450C63B-00
VFD550C63B-00
Frame W H D W1 H1 H2 H3 D1* D2 S1 S2 Ø1 Ø2 Ø3
mm 330.0 - 275.0 285.0 550.0 525.0 492.0 107.2 16.0 11.0 18.0 - - -
D1
inch 12.99 - 10.83 11.22 21.65 20.67 19.37 4.22 0.63 0.43 0.71 - - -
Frame W H D W1 H1 H2 H3 D1* D2 S1 S2
mm 280.0 - 255.0 235.0 500.0 475.0 442.0 94.2 16.0 11.0 18.0
D0-1
inch 11.02 - 10.04 9.25 19.69 18.70 17.40 3.71 0.63 0.43 0.71
*D1: Flange mount.
23
Frame D
D
W SEE DETAIL A D1
W1 D2
S2
SEE DETAIL B
1 1
3 3
2 2
S1 S1
DETAIL A DETAIL B
(MOUNTING HOLE) (MOUNTING HOLE)
MODEL
FRAME_D2 FRAME_D0-2
VFD300C23E VFD370C43U
VFD370C23E VFD450C43U
VFD550C43E
VFD750C43E
VFD450C63B-21
VFD550C63B-21
Frame W H D W1 H1 H2 H3 D1* D2 S1 S2 Ø1 Ø2 Ø3
mm 330.0 688.3 275.0 285.0 550.0 525.0 492.0 107.2 16.0 11.0 18.0 76.2 34.0 22.0
D2
inch 12.99 27.10 10.83 11.22 21.65 20.67 19.37 4.22 0.63 0.43 0.71 3.00 1.34 0.87
Frame W H D W1 H1 H2 H3 D1* D2 S1 S2 Ø1 Ø2 Ø3
mm 280.0 614.4 255.0 235.0 500.0 475.0 442.0 94.2 16.0 11.0 18.0 62.7 34.0 22.0
D0-2
inch 11.02 21.19 10.04 9.25 19.69 18.70 17.40 3.71 0.63 0.43 0.71 2.47 1.34 0.87
*D1: Flange mount.
24
Frame E
W D
W1 SEE DETAIL A D1
SEE DETAIL B S3 D2
MODEL
FRAME_E1
VFD450C23A VFD750C63B-00
VFD550C23A VFD900C63B-00
VFD750C23A VFD1100C63B-00
VFD900C43A VFD1320C63B-00
VFD1100C43A
25
Frame E
W D
W1 SEE DETAIL A D1
SEE DETAIL B S3 D2
MODEL
FRAME_E2
VFD450C23E VFD750C63B-21
VFD550C23E VFD900C63B-21
VFD750C23E VFD1100C63B-21
VFD900C43E VFD1320C63B-21
VFD1100C43E
Frame W H D W1 H1 H2 H3 D1* D2 S1 S2 S3 Ø1 Ø2 Ø3
mm 370.0 715.8 300.0 335.0 589.0 560.0 528.0 143.0 18.0 13.0 13.0 18.0 22.0 34.0 92.0
E2
inch 14.57 28.18 11.81 13.19 23.19 22.05 20.80 5.63 0.71 0.51 0.51 0.71 0.87 1.34 3.62
*D1: Flange mount.
26
Frame F
W D
W1 D1
See Detail A
See Detail B S3 D2
S1
S2
Detail A (Mounting Hole)
S1
MODEL
FRAME_F1
VFD900C23A
VFD1320C43A
VFD1600C43A
VFD1600C63B-00
VFD2000C63B-00
Frame W H D W1 H1 H2 H3 D1* D2 S1 S2 S3 Ø1 Ø2 Ø3
mm 420.0 - 300.0 380.0 800.0 770.0 717.0 124.0 18.0 13.0 25.0 18.0 92.0 35.0 22.0
F1
inch 16.54 - 11.81 14.96 31.50 30.32 28.23 4.88 0.71 0.51 0.98 0.71 3.62 1.38 0.87
*D1: Flange mount.
27
Frame F
W D
W1 D1
See Detail A
See Detail B S3 D2
S1
S2
Detail A (Mounting Hole)
S1
MODEL
FRAME_F2
VFD900C23E
VFD1320C43E
VFD1600C43E
VFD1600C63B-21
VFD2000C63B-21
Frame W H D W1 H1 H2 H3 D1* D2 S1 S2 S3 Ø1 Ø2 Ø3
mm 420.0 940.0 300.0 380.0 800.0 770.0 717.0 124.0 18.0 13.0 25.0 18.0 92.0 35.0 22.0
F2
inch 16.54 37.00 11.81 14.96 31.50 30.32 28.23 4.88 0.71 0.51 0.98 0.71 3.62 1.38 0.87
*D1: Flange mount.
28
Frame G
W D
W1
S3
MODEL
FRAME_G1
VFD1850C43A
VFD2200C43A
VFD2500C63B-00
VFD3150C63B-00
Frame W H D W1 H1 H2 H3 S1 S2 S3 Ø1 Ø2 Ø3
mm 500.0 - 397.0 440.0 1000.0 963.0 913.6 13.0 26.5 27.0 - - -
G1
inch 19.69 - 15.63 217.32 39.37 37.91 35.97 0.51 1.04 1.06 - - -
29
Frame G
W D
W1
S3
MODEL
FRAME_G2
VFD1850C43E
VFD2200C43E
VFD2500C63B-21
VFD3150C63B-21
Frame W H D W1 H1 H2 H3 S1 S2 S3 Ø1 Ø2 Ø3
mm 500.0 1240.2 397.0 440.0 1000.0 963.0 913.6 13.0 26.5 27.0 22.0 34.0 117.5
G2
inch 19.69 48.83 15.63 217.32 39.37 37.91 35.97 0.51 1.04 1.06 0.87 1.34 4.63
30
Frame H1
MODEL
FRAME_H1
VFD2800C43A
VFD3150C43A
VFD3550C43A
VFD4500C43A
Frame W H D W1 W2 W3 W4 W5 W6 H1 H2 H3 H4
mm 700.0 1435.0 398.0 630.0 290.0 - - - - 1403.0 1346.6 - -
H1
inch 27.56 56.50 15.67 24.80 11.42 - - - - 55.24 53.02 - -
Frame H5 D1 D2 D3 D4 D5 D6 S1 S2 S3 Ø1 Ø2 Ø3
mm - 45.0 - - - - - 13.0 26.5 25.0 - - -
H1
inch - 1.77 - - - - - 0.51 1.04 0.98 - - -
31
Frame H2
MODEL
FRAME_H2
VFD2800C43E-1
VFD3150C43E-1
VFD3550C43E-1
VFD4500C43E-1
Frame W H D W1 W2 W3 W4 W5 W6 H1 H2 H3 H4
mm 700.0 1745.0 404.0 630.0 500.0 630.0 760.0 800.0 - 1729.0 1701.6 - -
H2
inch 27.56 68.70 15.9 24.80 19.69 24.80 29.92 31.50 - 68.07 66.99 - -
Frame H5 D1 D2 D3 D4 D5 D6 S1 S2 S3 Ø1 Ø2 Ø3
mm - 51.0 38.0 65.0 204.0 68.0 137.0 13.0 26.5 25.0 - - -
H2
inch - 2.0 1.50 2.56 8.03 2.68 5.4 0.51 1.04 0.98 - - -
32
Frame H3
MODEL
FRAME_H3
VFD2800C43E
VFD3150C43E
VFD3550C43E
VFD4500C43E
Frame W H D W1 W2 W3 W4 W5 W6 H1 H2 H3 H4
mm 700.0 1745.0 404.0 630.0 500.0 630.0 760.0 800.0 - 1729.0 1701.6 - -
H3
inch 27.56 68.70 15.9 24.80 19.69 24.80 29.92 31.50 - 68.07 66.99 - -
Frame H5 D1 D2 D3 D4 D5 D6 S1 S2 S3 Ø1 Ø2 Ø3
mm - 51.0 38.0 65.0 204.0 68.0 137.0 13.0 26.5 25.0 22.0 34.0 117.5
H3
inch - 2.0 1.50 2.56 8.03 2.68 5.4 0.51 1.04 0.98 0.87 1.34 4.63
33
690 V Frame H1
MODEL
690V FRAME_H1
VFD4000C63B-00
VFD4500C63B-00
VFD5600C63B-00
VFD6300C63B-00
Frame W H D W1 W2 W3 W4 W5 W6 H1 H2 H3 H4
mm 700.0 - 398.0 - 630.0 290.0 - - - - 1435.0 1403.0 -
H1
inch 27.56 - 15.67 - 24.80 11.42 - - - - 56.50 55.24 -
Frame H5 D1 D2 D3 D4 D5 D6 S1 S2 S3 Ø1 Ø2 Ø3
mm 1346.6 45.0 - - - - - 13.0 26.5 25.0 - - -
H1
inch 53.02 1.77 - - - - - 0.51 1.04 0.98 - - -
34
690 V Frame H2
Side Fasteners
MODEL
690V FRAME_H2
VFD4000C63B-21
VFD4500C63B-21
VFD5600C63B-21
VFD6300C63B-21
Frame W H D W1 W2 W3 W4 W5 W6 H1 H2 H3 H4
mm 700.0 1745.0 404.0 800.0 630.0 - 500.0 630.0 760.0 1729.0 - - 1701.6
H2
inch 27.56 68.70 15.91 31.50 24.80 - 19.69 24.80 29.92 68.07 - - 66.99
Frame H5 D1 D2 D3 D4 D5 D6 S1 S2 S3 Ø1 Ø2 Ø3
mm 1346.6 51.0 38.0 65.0 204.0 68.0 137.0 13.0 26.5 25.0 22.0 34.0 117.5
H2
inch 53.02 2.01 1.50 2.56 8.03 2.68 5.39 0.51 1.04 0.98 0.87 1.34 4.63
35
Accessories
▪▪ EMC-PG01L / EMC-PG02L
Terminals Description
Output voltage for power: +5 V / +12 V ± 5% (use FSW3 to switch +5 V / +12 V)
VP
Max. output current: 200 mA
DCM Common for power and signal
PG1
Encoder input signal (Line Driver)
A1, / A1, Open collector input: +5 V / +24 V (Note1)
B1, / B1, Z1, / Z1 1-phase or 2-phase input
Max. input frequency: EMC-PG01L: 300KHz; EMC-PG02L: 30KHz
Pulse input signal (Line Driver or Open Collector)
A2, / A2, Open collector input: +5 V / +24 V (Note1)
PG2
B2, / B2 1-phase or 2-phase input
Set by
Max. input frequency: EMC-PG01L: 300KHz; EMC-PG02L: 30KHz
Pr.10-00 ~ 10-02
PG card output signals. Division frequency function: 1 ~ 255 times
Max. output voltage for Line driver: 5 VDC
AO, / AO,
Max. output current: 50 mA
PG OUT BO, / BO,
Max. output frequency: EMC-PG01L: 300KHz; EMC-PG02L: 30KHz
ZO, / ZO, SG
SG: The GND of PG card is the same as the host controller or PLC, so a common
output signal is attained.
▪▪ EMC-PG01O / EMC-PG02O
Terminals Description
Output voltage for power: +5 V / +12 V ± 5% (use FSW3 to switch +5 V / +12 V)
VP
Max. output current: 200 mA
DCM Common for power and signal
PG1
Encoder input signal (Line Driver or Open Collector)
A1, / A1 ,B1, / B1, Open collector input: +5 V / +24 V (Note1)
Z1, / Z1 1-phase or 2-phase input
Max. input frequency: EMC-PG01O: 300KHz; EMC-PG02O: 30KHz
Pulse input signal (Line Driver or Open Collector)
A2, / A2, Open collector input: +5 V / +24 V (Note1)
PG2
B2, / B2 1-phase or 2-phase input
Max. input frequency: EMC-PG01O: 300KHz; EMC-PG02O: 30KHz
Set by Needs external power source for PG OUT circuit.
V+, / V-
Pr.10-00 ~ 10-02 Input voltage of power:+12 V ~ +24 V
V- Negative power supply input
▪▪ EMC-PG01R
Terminals Description
R1- R2 Resolver output power 7 Vrms, 10 kHz
PG1
S1,S2, S3, S4 Resolver input signal 3.5 ± 0.175 Vrms, 10 kHz
Pulse input signal (Line Driver or Open Collector)
PG2 A2, / A2, B2, / B2 Open collector input: +5 V / +24 V (Note1)
1-phase or 2-phase input; Max. input frequency: 300 KHz
PG card output signals. Division frequency function: 1 ~ 255 times
Max. output voltage for Line driver: 5 VDC
Set by AO, / AO,
Max. output current: 50 mA
Pr.10-00 ~ 10-02 PG OUT BO, / BO,
Max. output frequency: 300 KHz
ZO, / ZO, SG
SG: The GND of PG card is the same as the host controller or PLC, so a common
output signal is attained.
36
▪▪ EMC-PG01U / EMC-PG02U
▪▪ EMC-D42A
Terminals Description
Common for multi-function input terminals
COM
Select SINK (NPN) / SOURCE (PNP) in J1 jumper / external power supply
Refer to Pr. 02-26 ~ Pr. 02-29 to program the multi-function inputs MI10 ~ MI13.
Internal power is applied from terminal E24: +24 VDC ± 5% 200 mA, 5 W
MI10 ~ MI13
External power +24 VDC: max. voltage 30 VDC, min. voltage 19 VDC, 30 W
ON: the activation current is 6.5 mA; OFF: leakage current tolerance is 10 μA
Multi-function output terminals (photocoupler)
I/O Extension Card MO10 ~ MO11 Duty-cycle: 50%; Max. output frequency: 100 Hz
Max. current: 50 mA; Max. voltage: 48 VDC
Common for multi-function output terminals MO10, MO11 (photocoupler)
MXM
Max 48 VDC 50 mA
▪▪ EMC-D611A
Terminals Description
AC AC power common for multi-function input terminal (Neutral)
37
▪▪ EMC-R6AA
Terminals Description
▪▪ EMC-A22A
Terminals Description
Refer to Pr. 14-00 ~ Pr. 14-01 for function selection (input), and Pr. 14-18 ~ Pr. 14-19 for mode selection.
AVI10 There are two sets of AVI port, SSW3(AVI10) and SSW4(AVI11), which can be switched to AVI or ACI.
AVI11 AVI: Input 0 ~ 10V
ACI: Input 0 ~ 20mA / 4 ~ 20mA
Refer to Pr. 14-12 ~ Pr. 14-13 for function selection (output), and Pr. 14-36 ~ Pr. 14-37 for mode selection.
AFM10 There are two sets of AFM port, SSW1(AFM10) and SSW2(AFM11), which can be switched to AVO or ACO.
Analog I/O AFM11
extension card AVO: Output 0 ~ 10.00V
ACO: Output 0 ~ 20.0mA / 4.0 ~ 20.0mA
▪▪ EMC-BPS01
Terminals Description
When the AC motor drive power is off, the external power supply card provides external power to the network
system, PLC function, and other functions to allow continued operations.
Input power: 24 VDC ±5%
24 V GND Maximum input current: 0.5 A
Note:
24V Power Do not connect the control terminal +24 V (Digital control signal common: SOURCE) directly to the EMC-BPS01 input terminal 24 V.
Do not connect control terminal GND directly to the EMC-BPS01 input terminal GND.
Shift Card
38
▪▪ CMC-EIP01
Features
►► Support EtherNet/IP and MODBUS TCP protocol
►► User-defined parameter mapping
►► IP Filter, basic firewall function
Network Interface
Network Interface
Interface RJ-45 with Auto MDI / MDIX Transmission speed 10 / 100 Mbps Auto-Detect
Number of ports 1 Port ICMP, IP, TCP, UDP, DHCP, BOOTP, SMTP,
Network protocol
EtherNet/IP, Modbus TCP
Transmission method IEEE 802.3, IEEE 802.3u
Transmission cable Category 5e shielding 100 M
▪▪ CMC-EC01
Features
►► Supports Ethernet CAT protocol
►► Supports standard CiA402 speed mode
►► Supports SDO (Service Data Objects) function:
- To write motor drive parameters
- To read motor drive information
►► Auto shutdown function for interruptions during data transmission
Network Interface
Interface RJ-45 Transmission speed 100 Mbps
Number of ports 2 Ports Network protocol EtherCAT
Transmission method IEEE 802.3, IEEE 802.3u
Transmission cable Category 5e shielding 100 M
▪▪ CMC-PD01
Features
►► Supports PROFIBUS DP protocol
►► Supports PZD control data exchange
►► Supports PKW polling AC motor drive parameters
►► Supports user diagnosis function
►► Auto-detects baud rates; supports Max. 12 Mbps
39
▪▪ CMC-DN01
CMC-DN01 Features
►► Supports all baud rates on DeviceNet bus: 125 kbps, 250 kbps, 500 kbps and extendable
serial transmission speed mode
►► Basedon the high-speed communication interface of Delta HSSP protocol, able to
conduct immediate control of an AC motor drive
►► Supports Group 2 only connection and polling I/O data exchange
►► For I/O mapping, supports Max. 32 words of input and 32 words of output
►► Supports EDS file configuration in DeviceNet configuration software
►► Node address and serial transmission speed can be set up on AC motor drive
►► Power supplied from AC motor drive
▪▪ EMC-COP01
Built-in EMC-COP01 card are available for VFDXXXC23E and VFDXXXC43E
RJ-45 Pin definition
Pin Pin name Definition
1 CAN_H CAN_H bus line (dominant high)
2 CAN_L CAN_L bus line (dominant low)
8~1 3 CAN_GND Ground / 0 V / V-
8~1
Male Female
6 CAN_GND Ground / 0 V / V-
40
Accessories
▪▪ Delta Standard Fieldbus Cables
Delta Cables Part Number Description Length
UC-CMC003-01A CANopen cable, RJ45 connector 0.3 m
UC-CMC005-01A CANopen cable, RJ45 connector 0.5 m
UC-CMC010-01A CANopen cable, RJ45 connector 1 m
UC-CMC015-01A CANopen cable, RJ45 connector 1.5 m
CANopen Cable UC-CMC020-01A CANopen cable, RJ45 connector 2 m
UC-CMC030-01A CANopen cable, RJ45 connector 3 m
UC-CMC050-01A CANopen cable, RJ45 connector 5 m
UC-CMC100-01A CANopen cable, RJ45 connector 10 m
UC-CMC200-01A CANopen cable, RJ45 connector 20 m
UC-DN01Z-01A DeviceNet cable 305 m
DeviceNet Cable
UC-DN01Z-02A DeviceNet cable 305 m
UC-EMC003-02A EtherNet / EtherCAT cable, Shielding 0.3 m
UC-EMC005-02A EtherNet / EtherCAT cable, Shielding 0.5 m
UC-EMC010-02A EtherNet / EtherCAT cable, Shielding 1 m
EtherNet Cable UC-EMC020-02A EtherNet / EtherCAT cable, Shielding 2 m
UC-EMC050-02A EtherNet / EtherCAT cable, Shielding 5 m
UC-EMC100-02A EtherNet / EtherCAT cable, Shielding 10 m
UC-EMC200-02A EtherNet / EtherCAT cable, Shielding 20 m
TAP-CN01 1 in 2 out, built-in 121Ω terminal resistor 1 in 2 out
CANopen / DeviceNet TAP TAP-CN02 1 in 4 out, built-in 121Ω terminal resistor 1 in 4 out
TAP-CN03 1 in 4 out, RJ45 connector, built-in 121Ω terminal resistor 1 in 4 out
PROFIBUS Cable UC-PF01Z-01A PROFIBUS DP cable 305 m
Unit: mm
L ± 10
Model: TAP-CN03
Unit: mm [inch]
41
Model Name
▪ 230 V / 460 V:
VFD 007 C 43 A
Version
A Wall mount
S Smaller size
Input voltage U Smaller size with junction box
23 230 V 3-Phase Built-in EMC filter (Frame A~C),
E
43 460 V 3-Phase Built-in conduit box (Frame D and above)
Product Series
C C2000
Series Name
Variable Frequency Drive
▪ 575 V / 690 V:
VFD 007 C 43 A - 2 1
NEMA Protection Level
0 UL Open Type
1 NEMA 1
IP Protection Level
Version
0 IP00 2 IP20
A Wall mount
B Wall mount with 690V rated current
Input Voltage
53 575 V 3-Phase
63 690 V 3-Phase
Product Series
C C2000
Series Name
Variable Frequency Drive
42
Ordering Information
Frame Size Power Range Models
Frame A
230 V: VFD007C23A VFD007C43A VFD007C43E VFD015C53A-21
0.75 ~ 3.7 kW VFD015C23A VFD015C43A VFD015C43E VFD022C53A-21
VFD022C23A VFD022C43A VFD022C43E VFD037C53A-21
460 V: VFD037C23A VFD037C43A VFD037C43E
0.75 ~ 5.5 kW VFD040C43A VFD040C43E
VFD055C43A VFD055C43E
575 V:
1.5 ~ 3.7 kW
Frame B
230 V: VFD055C23A VFD075C43A VFD075C43E VFD055C53A-21
5.5 ~ 11 kW VFD075C23A VFD110C43A VFD110C43E VFD075C53A-21
VFD110C23A VFD150C43A VFD150C43E VFD110C53A-21
460 V: VFD150C53A-21
7.5 ~ 15 kW
575 V:
5.5 ~ 15 kW
Frame C
230 V: VFD150C23A VFD185C43A VFD185C43E VFD185C63B-21
15 ~ 22 kW VFD185C23A VFD220C43A VFD220C43E VFD220C63B-21
VFD220C23A VFD300C43A VFD300C43E VFD300C63B-21
460 V: VFD370C63B-21
18.5 ~ 30 kW
690 V:
18.5 ~ 37 kW
Frame D
230 V: Frame_D1 Frame_D0-1 Frame_D2 Frame_D0-2
30 ~ 37 kW VFD300C23A VFD370C43S VFD300C23E VFD370C43U
VFD370C23A VFD450C43S VFD370C23E VFD450C43U
460 V: VFD550C43A VFD550C43E
37 ~ 75 kW VFD750C43A VFD750C43E
VFD450C63B-00 VFD450C63B-21
690 V: VFD550C63B-00 VFD550C63B-21
55 ~ 75 kW
Frame E
230 V: Frame_E1 Frame_E2
45 ~ 75 kW VFD450C23A VFD450C23E
VFD550C23A VFD550C23E
460 V: VFD750C23A VFD750C23E
90 ~ 110 kW VFD900C43A VFD900C43E
VFD1100C43A VFD1100C43E
690 V: VFD750C63B-00 VFD750C63B-21
75 ~ 132 kW VFD900C63B-00 VFD900C63B-21
VFD1100C63B-00 VFD1100C63B-21
VFD1320C63B-00 VFD1320C63B-21
Frame F
230 V: Frame_F1 Frame_F2
90 kW VFD900C 23A VFD900C 23E
VFD1320C 43A VFD1320C 43E
460 V: VFD1600C 43A VFD1600C 43E
132 ~ 160 kW VFD1600C63B-00 VFD1600C63B-21
VFD2000C63B-00 VFD2000C63B-21
690 V:
160 ~ 200 kW
43
Frame Size Power Range Models
Frame G
460 V: Frame_G1 Frame_G2
185 ~ 220 kW VFD1850C43A VFD1850C43E
VFD2200C43A VFD2200C43E
690 V: VFD2500C63B-00 VFD2500C63B-21
250 ~ 315 kW VFD3150C63B-00 VFD3150C63B-21
Frame H
460 V: Frame_H1 Frame_H2 Frame_H3
280 ~ 450 kW VFD2800C43A VFD2800C43E-1 VFD2800C43E
VFD3150C43A VFD3150C43E-1 VFD3150C43E
VFD3550C43A VFD3550C43E-1 VFD3550C43E
VFD4500C43A VFD4500C43E-1 VFD4500C43E
Frame H
690 V: Frame_H1 Frame_H2
(690 V Model) VFD4000C63B-00 VFD4000C63B-21
400 ~ 630 kW
VFD4500C63B-00 VFD4500C63B-21
VFD5600C63B-00 VFD5600C63B-21
VFD6300C63B-00 VFD6300C63B-21
44
Global Operations
Northern Europe
A Finland
B Estonia
C Latvia
D Lithuania
Netherlands Germany E Sweden
Canada Amsterdam Sust F Denmark
Vancouver Eindhoven G A
G Iceland
E
France F
B
C Russ
Paris Ireland
Sacramento USA United
Kingdom N
D Belarus
Ukraine
Moscow
Fremont Kitchener H I
Spain
O
Chicago Moldavia
City of Industry France J L
Boston Barcelona K M Romania
Madrid Spain
Italy Bulgaria Turkey
Dallas
Houston Raleigh Portugal Istanbul A
Mexico City
R. Dominicana
Puerto Rico
H Netherlands Egypt Qatar
Columbia Kenya
Ecuador
Tanzania
Peru Brasil
Bolivia
Uruguay
Argentina
45
Factories 5 Branch Offices 102 R&D Centers 6 D i s t r i b u t o r s 824
Korea
Seoul
sia Daegu
w Japan
Tokyo
Osaka
1
Kyrgyzstan
Uzbekistan
2 Japan
Azerbaijan
nia 4
3
Korea Shanghai
7
5
6 8 Wujiang
19 9
20
Pakistan 21
11
10
12
Taoyuan
(Technology Center & Plant 1)
UAE 18 23
22 14 13
Dubai
Bangladesh 17 16 15 Zhong Li
Oman
Myanmar Thailand Taichung
India
Chandigarh Vietnam Tainan
Gurgaon Philippines
Kolkata
Sri Lanka
Malaysia China
Ahmedabad Singapore Heilongjiang Jiangsu 1 9 13 Fujian 19 Shaanxi
Mumbai
Pune
Indonesia Harbin Yangzhou
Nanjing
Xiamen Xian
2 Jilin 14 Jiangxi 20 Henan
Hyderabad Nantong
Changchun Nanchang Zhengzhou
Bangalore Changzhou
Chennai 3 Liaoning Wuxi 15 Guangdong 21 Hubei
Shenyang Suzhou Shantou Wuhan
Coimbatore
Dalian Zhangjiagang Dongguan
Visakhapatnam 22 Hunan
Shenzhen
Jamshedpur 4 Shanxi Shanghai Changsha
10 Guangzhou
Taiyuan Foshan 23 Chongqing
11 Anhui
5 Beijing Hefei 16 Guangxi
Tianjin Nanning
Australia Zhejiang
6 12
New Zealand
46
Industrial Automation Headquarters
Delta Electronics, Inc.
Taoyuan Technology Center
No.18, Xinglong Rd., Taoyuan District,
Taoyuan City 33068, Taiwan
TEL: 886-3-362-6301 / FAX: 886-3-371-6301
Asia EMEA
Delta Electronics (Shanghai) Co., Ltd. Headquarters: Delta Electronics (Netherlands) B.V.
No.182 Minyu Rd., Pudong Shanghai, P.R.C. Sales: Sales.IA.EMEA@deltaww.com
Post code : 201209 Marketing: Marketing.IA.EMEA@deltaww.com
TEL: 86-21-6872-3988 / FAX: 86-21-6872-3996 Technical Support: iatechnicalsupport@deltaww.com
Customer Service: 400-820-9595 Customer Support: Customer-Support@deltaww.com
Service: Service.IA.emea@deltaww.com
Delta Electronics (Japan), Inc. TEL: +31(0)40 800 3800
Tokyo Office
Industrial Automation Sales Department BENELUX: Delta Electronics (Netherlands) B.V.
2-1-14 Shibadaimon, Minato-ku De Witbogt 20, 5652 AG Eindhoven, The Netherlands
Tokyo, Japan 105-0012 Mail: Sales.IA.Benelux@deltaww.com
TEL: 81-3-5733-1155 / FAX: 81-3-5733-1255 TEL: +31(0)40 800 3800
*We reserve the right to change the information in this catalogue without prior notice.
DELTA_IA-MDS_C2000_C_EN_20190517