Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

University of Salerno Department of Civil Engineering: Design of Steel Structures

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

DETAIL A

Plane view Lateral view Front view


1. Column base joint
Gusset plate

Base column
HE 450 M
S275

Bracing member
Stiffeners S275
139,7X12,5

Column base plate


thickness 65 mm Anchor bolts
S275 Grouting diameter 33 mm
thickness 35 mm
953
75

Concrete 30/37
154

Washer

612
154
154

Shear lug
HE 120 B
S275
75

75 170 288 170 170 80

2. Gusset plate Front view

Base column
S275
HE 450 B UNIVERSITY OF SALERNO
Hinge zone Bracing member
Department of Civil Engineering
thickness 2t S275 Master Programme in Civil Engineering
139,7x12,5

Design of Steel Structures


Gusset plate A.A. 2019/2020
thickness 34 mm

Design and verification of a steel building


A=510

Stiffener
=4
91
.5

70 1 Concentrically braced frame


=2
Lb
2 Detail A: Column base joint and gusset plate
Lgph=40
3 Floor plan and cross section of the slab
Concrete 30/37
4 Detail B: Secondary to primary beam joint
B=305

STUDENT: PROFESSORS:
de la Pena, Amparo
matr. 0622101154
Prof. Ing. Vincenzo Piluso
Prof. Ing. Massimo Latour
2