Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Sprint 210: Modular Two Way Communicate and Optional Load Control

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Sprint 210

Three-phase smart meter - Open protocol Remote


disconnect
Modular
communication
Power outage
notification

Modular two way communicate and optional load control

Sprint 210 is a three-phase meter with flexible, modular


communications capability, including DLMS/COSEM. The
communications module can be fitted at manufacture, or
installed and replaced in the field. This simplifies inventory
management and maximizes operational flexibility, by enabling
the best technologies to be used, now and in the future.

Sprint 210 paves the way for easy and convenient data transfer
from the meter to the utility's back office, and is the ideal
solution for AMI applications. Provision for a range of
communication technologies, including mesh radio and 3G/4G
devices, ensures that Sprint 210 will meet your current and
future needs.

Application Features
Ÿ Domestic three-phase metering Ÿ Four-quadrant metering with import/export registration
Ÿ Small commercial premises Ÿ Integrated mains supply contactor (AMI-ready) and
Ÿ Advanced metering infrastructure (AMI) and AMI-ready auxiliary load terminals (build options)
Ÿ Co-generation metering Ÿ Remote and local de-energisation and energisation
Ÿ Support for AMI features: TOU-based switching, boost and
Benefits supply capacity control (variant specific)
Ÿ Easy integration with AMI system through modular Ÿ Remote firmware upgrades
communications Ÿ Large capacity power supply to support high
Ÿ Front-mounted communications module for easy fitment and communications demands
replacement in the field Ÿ Communications 'front belly' module, supporting a range
Ÿ Helps consumers to reduce energy usage, through detailed of devices
and timely information Ÿ Enhanced profile storage, with primary load profile for
Ÿ Enhanced operational flexibility and simplified inventory energy data and secondary profile for supply quality
management through pre-loaded configurations Ÿ Logging and remote notification (alarm) of events
Ÿ Quality of supply (QoS) monitoring
Options and Accessories Ÿ Provision for tamper detection

Ÿ Integrated mains supply contactor Ÿ DLMS/COSEM open protocol compliant

Ÿ Auxiliary load control terminals Ÿ Meets the minimum services specifications (Australian

Ÿ Customer supply monitoring National Electricity Rules)


Ÿ Various terminal cover sizes
Ÿ ZigBee compliant in-home display Software
Ÿ Optical communications probe Ÿ M-Cubed 100 software suite for meter configuration and
reading
Sprint 210
Technical specifications
Electrical
Connection type 3 phase, 4 wire, direct connected
Rated voltage 230 V AC, -20% tp +15%
Maximum voltage 460 V (L-N)
Impulse withstand 10 kV, 0.5J (as per IEC)
12 kV, 9J (as per NMI M6)
Frequency 50 Hz ± 5%
Current range 10 A Lb, 100A Imax
Accuracy Class 1.0 (active energy), class 2.0(reactive energy)

Compliance
Standards* AS 62052.11, AS 62052.21, AS 62053.21, AS 62053.23, NMI M6-1
IEC 62052.11, IEC 62052.21, IEC 62053.21, IEC 62053.23, IEC62056 series
(DLMS/COSEM)
Exceeds minimum services specification, as per the Australian National
Electricity Amendment (expanding competition in metering and related
services)

Mechanical
Dimensions (WxHxD) 180 mm x 221 mm x 118 mm (standard terminal block cover)
180 mm x 252 mm x 118 mm (extended terminal block cover)
Enclosure material Flame-retardant polycarbonate
Sealing Terminal cover, meter main cover, config button, communications module
Weight 2.4 kg (approx.)
Display 8-character alphanumeric LCD with backlight and icons for status

Environmental
Temperature Operating: -10°C to +60°C | Storage: -25°C to +70°C
Humidity 95%, non-condensing
Ingress protection IP 53
Insulation class Protective class II

Data storage capacity


Energy/demand load profile 1680 days (single channel) @ 30 minute interval (configurable)
QoS parameters >3000 days (single parameter) @ 30 minute interval (configurable), depending
on variant

Switches/outputs
Mains supply contactor 100 A (build option)
Auxiliary load control 31.5 A and/or 2 A (build options)

Time clock
RTC type Crystal or mains-synchronised
Power source Mains supply
Backup Lithium battery, 15-year life
Compliance AS 62054.21, IEC/BSEN 62054.21
Specifications are subject to change without prior notice

Measurement
Energy type Active, reactive

Communication
Local ANSI or IEC optical port
Remote LAN/HAN/WAN, with support for most communications topologies
Hot-swappable interchangeable modules, sealable separately
Security AES128 encryption, cover-open detection
Outage notification Reserve power supply (build option)

*For detailed specification, please refer to technical specification guide