Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Parasite Zapper: Index Terms

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3
At a glance
Powered by AI
The key takeaways are that a zapper is a device that uses electrical frequencies to kill parasites, bacteria, and other pathogens in order to boost the immune system and treat diseases.

The main components of a zapper kit are a frequency generator, hand and foot plates to transmit the electrical signals to the body, and batteries to power it.

A zapper works by generating specific electrical frequencies that target and kill parasites and pathogens wherever the current reaches in the body through veins and lymphatic system, boosting the immune system's ability to fight diseases.

© 2019 JETIR May 2019, Volume 6, Issue 5 www.jetir.

org (ISSN-2349-5162)

Parasite zapper
[1]
Gita Reshmi, [2]Rahul C H, [3]Shankara Murthi, [4]Abdul Saleem, [5]Rishab Solanki
[1]
Assistant Professor, Department of Electronics and Communication engineering, PDIT Hospete,
[2],[3],[4],[5]
BE Students, Department of Electronics and Communication engineering, PDIT Hospete,

Abstract— The basic problem that humans are facing is the health problems, humans are Sensitive that even if they migrate from
one place to another place there will be chance of health effect such as cold, fever, due to change in water and atmosphere. Even
though the humans have immunity power to defense against these health problems, sometimes they may fail to fight against some health
problems caused by some parasites or bacteria. In this case we need to activate the immunity power so that they can defeat against
parasites and this can be done by the boosting the immune cells. The purpose of zapper is focused on health issues of human body as
well as contaminated vegetables and fruits. The zapper kit is designed to fight against those problems on human body, vegetables and
fruits. Parasites and bacteria can be kill when the electricity reaches But as it may be, a few areas that are not reachable, for example,
tooth hole and within tumors. The current isn't uniform through the body. To overcome these problems we use zapper. It will beat these
issues by giving frequency through the body.

Index Terms— ARDUINO, AD9833, DIGITAL POT, DC CONVERTORS.


preselected programs that are viable for explicit medical
issues like herpes, Lyme sickne
I. INTRODUCTION
ss, influenza, chicken pox, and some more. Zapper is
Generally humans have parasites and bacteria that
particularly planned such that it produces recognizable
cause various difficulties. There are natural and electronic
outcomes in a brief span. The gadget makes modest
strategies to remove them, one of those method is zapper.
electrical heartbeats, with a positive DC voltage
This concept can be implemented by the simple circuit
counterbalance that is connected to the body. The
(Zapper) which can produce frequency of specified range that
association with the body is kept up by means of hand and
boost the immune system which can fight against respective
foot plate anodes. Inside the body these modest current
parasites. All diseases are brought about by remote life forms
heartbeats go through pretty much every kind of tissues,
and contaminations that harm the insusceptible framework.
including organs, muscles and particularly veins and
By disposing of parasites, microorganisms and infections
lymphatic framework. The particular frequencies slaughter
from the body by applying frequency, these diseases can be
parasites and microscopic organisms wherever the present
cured. One such implementation is implemented in this
contacts them. Despite the fact that the current does not
concept.
achieve the locales like eyes, the informative supplement,
the testicles and the internal ear bones.
METHODOLOGY
Zapper is a small battery powered electronic device. Its main
role was to enable the body to battle against parasites,
infections, microscopic organisms and so on by applying little
electrical flows utilizing a particular waveform and
recurrence. Zapper is an extremely straightforward kit with
just a single all inclusive recurrence that should be utilized
commonly to get strong outcomes, yet isn't so powerful for
explicit medical issues.
\

Fig: 1.2 Zapper Circuit

The fig: 1.2 shows a circuit of a zapper used to kill the


bacteria, parasites etc. which are present on the fruits,
vegetables etc. The circuit produces different types of
Fig: 1.1 Zapper kit frequencies which are suitable for different types of fruits
and vegetables. Which makes the fruits clean and healthy to
eat.
It is a completely programmable computerized frequency
generator with the most recent highlights of the solid and
programmable structure. It contains more than 2000

JETIRCJ06046 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 210
© 2019 JETIR May 2019, Volume 6, Issue 5 www.jetir.org (ISSN-2349-5162)

ARDUINO:

Fig:1.4 Arduino nano

The Arduino Nano is a little, total, and


breadboard-accommodating board dependent on
ATmega328P (Arduino Nano 3.x). It has pretty
much a similar usefulness of the Arduino
Duemilanove, yet in an alternate bundle. It needs
just a DC control jack, and works with a Mini-B
USB link rather than a standard one. Here are not
many of its fundamental highlights which you
should know whether you are thinking to deal
Fig: 1.3 Zapper block diagram
with this incredible microcontroller board:
The fig: 1.3 shows the flow diagram of the zapper, which
consist of two main components Arduino and AD9833. • Totally it has 22 I/O pins.

Initially the codes are filled on Arduino for which frequency • Among 22 pins, 14 are digital pins.
range has to be produced among different frequency ranges.
There are different frequency ranges in which the respective • 8 analog pins are available in Arduino Nano.
bacteria and parasites cannot be survive. Code is dumped
using software Arduino IDE that uses embedded C
• Among the digital pins, it has 6 PWM pins.
language. We have designed an application that can be used • It has a crystal oscillator about 16MHz.
through smart mobile in which we need to select particular
disease for treatment of the patient. After selecting, the • Its operating voltage ranges from 5V to 12V.
mobile application will send response to Arduino to produce
respective frequency to cure. The communication between • There are different ways of communication, which
the mobile application and Arduino will be takes place are:
through Bluetooth. Once the Arduino receives the response, o Serial Protocol.
it make use of AD9833 to generate the required frequency
range. The copper plates are designed by which frequency o I2C Protocol.
can pass through our body. This is working procedure of
o SPI Protocol.
zapping. The detailed description of main component used
in zapper circuit is as follows • To upload code, it has a mini USB Pin.

JETIRCJ06046 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 211
© 2019 JETIR May 2019, Volume 6, Issue 5 www.jetir.org (ISSN-2349-5162)
• AD9833

CONCLUSION
The “Zapper” is one of the most innovative new treatment
options. Having identified that everything emits its own
unique frequency that exposing an harm organism present on
human body to its own quality frequency can effectively
destroy it. Our trademark frequencies are far from those of
the pathogens that make us sick, so we can execute them
electrically without unfavorably influencing ourselves. This
should be possible by utilizing a recurrence generator that
specifically devastates specific pathogens, parasites,
infections or by utilizing a critic. A critic is an electronic
gadget that keeps running on a 9 – volt battery and produces
a positive balance recurrence it kills all parasites, microscopic
organisms that it comes to all the while in 7 minutes. So that
parasites or bacteria which can cause illness, can kill by using
zapper.
Fig: 1.5 ANALOG DEVICE 9833
The AD9833 is a low power, programmable waveform
REFERENCES
generator equipped for delivering sine, triangular, and
square wave yields. Waveform range is required in [1] Dr. Hulda Regehr Clark (18 October 1928–2003 September
different sorts of detecting, incitation, and time space 2009), and was a Canadian naturopath, author, and practitioner
reflectometry (TDR) applications. The yield frequency of alternative medicine, “zapping” ,Canada in 1993.
and stage are programming programmable, permitting
simple tuning. No outside segments are required. The
recurrence registers are 28 bits wide: with a 25 MHz
clock rate, goals of 0.1 Hz can be accomplished; with a
1 MHz clock rate, the AD9833 can be tuned to 0.004
Hz goals. The AD9833 is composed to by means of a 3-
wire sequential interface. This sequential interface
works at clock rates up to 40 MHz and is good with
DSP and microcontroller norms. The gadget works with
a power supply from 2.3 V to 5.5 V. The AD9833 has a
shutdown capacity (SLEEP). This capacity permits
segments of the gadget that are not being utilized to be
shut down, along these lines limiting the present
utilization of the part. For instance, the DAC can be
shut down when a clock yield is being created.

ADVANTAGES OF PARASITE ZAPPER:

• With stabilized voltage as well as regulated


process, Parasite Zapper provide a wide range of
health benefits.
• It can successfully treat issues like Flu, Herpes,
Diabetes, Asthma, Cancer, Heart diseases,
Hemorrhoids, Pediatric diseases as well as a
variety of other conditions.
• Parasitic Zapper is cheap and best solution for
health problem.
• This kit does not have any side-effect when
compared to today’s medicine.
• Even healthy persons can have benefit from
regularly use of zapper, as the process detects
toxins throughout the body to get new level of
immune system.

JETIRCJ06046 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 212

You might also like