Parasite Zapper: Index Terms
Parasite Zapper: Index Terms
Parasite Zapper: Index Terms
org (ISSN-2349-5162)
Parasite zapper
[1]
Gita Reshmi, [2]Rahul C H, [3]Shankara Murthi, [4]Abdul Saleem, [5]Rishab Solanki
[1]
Assistant Professor, Department of Electronics and Communication engineering, PDIT Hospete,
[2],[3],[4],[5]
BE Students, Department of Electronics and Communication engineering, PDIT Hospete,
Abstract— The basic problem that humans are facing is the health problems, humans are Sensitive that even if they migrate from
one place to another place there will be chance of health effect such as cold, fever, due to change in water and atmosphere. Even
though the humans have immunity power to defense against these health problems, sometimes they may fail to fight against some health
problems caused by some parasites or bacteria. In this case we need to activate the immunity power so that they can defeat against
parasites and this can be done by the boosting the immune cells. The purpose of zapper is focused on health issues of human body as
well as contaminated vegetables and fruits. The zapper kit is designed to fight against those problems on human body, vegetables and
fruits. Parasites and bacteria can be kill when the electricity reaches But as it may be, a few areas that are not reachable, for example,
tooth hole and within tumors. The current isn't uniform through the body. To overcome these problems we use zapper. It will beat these
issues by giving frequency through the body.
JETIRCJ06046 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 210
© 2019 JETIR May 2019, Volume 6, Issue 5 www.jetir.org (ISSN-2349-5162)
ARDUINO:
Initially the codes are filled on Arduino for which frequency • Among 22 pins, 14 are digital pins.
range has to be produced among different frequency ranges.
There are different frequency ranges in which the respective • 8 analog pins are available in Arduino Nano.
bacteria and parasites cannot be survive. Code is dumped
using software Arduino IDE that uses embedded C
• Among the digital pins, it has 6 PWM pins.
language. We have designed an application that can be used • It has a crystal oscillator about 16MHz.
through smart mobile in which we need to select particular
disease for treatment of the patient. After selecting, the • Its operating voltage ranges from 5V to 12V.
mobile application will send response to Arduino to produce
respective frequency to cure. The communication between • There are different ways of communication, which
the mobile application and Arduino will be takes place are:
through Bluetooth. Once the Arduino receives the response, o Serial Protocol.
it make use of AD9833 to generate the required frequency
range. The copper plates are designed by which frequency o I2C Protocol.
can pass through our body. This is working procedure of
o SPI Protocol.
zapping. The detailed description of main component used
in zapper circuit is as follows • To upload code, it has a mini USB Pin.
JETIRCJ06046 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 211
© 2019 JETIR May 2019, Volume 6, Issue 5 www.jetir.org (ISSN-2349-5162)
• AD9833
CONCLUSION
The “Zapper” is one of the most innovative new treatment
options. Having identified that everything emits its own
unique frequency that exposing an harm organism present on
human body to its own quality frequency can effectively
destroy it. Our trademark frequencies are far from those of
the pathogens that make us sick, so we can execute them
electrically without unfavorably influencing ourselves. This
should be possible by utilizing a recurrence generator that
specifically devastates specific pathogens, parasites,
infections or by utilizing a critic. A critic is an electronic
gadget that keeps running on a 9 – volt battery and produces
a positive balance recurrence it kills all parasites, microscopic
organisms that it comes to all the while in 7 minutes. So that
parasites or bacteria which can cause illness, can kill by using
zapper.
Fig: 1.5 ANALOG DEVICE 9833
The AD9833 is a low power, programmable waveform
REFERENCES
generator equipped for delivering sine, triangular, and
square wave yields. Waveform range is required in [1] Dr. Hulda Regehr Clark (18 October 1928–2003 September
different sorts of detecting, incitation, and time space 2009), and was a Canadian naturopath, author, and practitioner
reflectometry (TDR) applications. The yield frequency of alternative medicine, “zapping” ,Canada in 1993.
and stage are programming programmable, permitting
simple tuning. No outside segments are required. The
recurrence registers are 28 bits wide: with a 25 MHz
clock rate, goals of 0.1 Hz can be accomplished; with a
1 MHz clock rate, the AD9833 can be tuned to 0.004
Hz goals. The AD9833 is composed to by means of a 3-
wire sequential interface. This sequential interface
works at clock rates up to 40 MHz and is good with
DSP and microcontroller norms. The gadget works with
a power supply from 2.3 V to 5.5 V. The AD9833 has a
shutdown capacity (SLEEP). This capacity permits
segments of the gadget that are not being utilized to be
shut down, along these lines limiting the present
utilization of the part. For instance, the DAC can be
shut down when a clock yield is being created.
JETIRCJ06046 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 212