ADAM-6521 Series: User Manual
ADAM-6521 Series: User Manual
ADAM-6521 Series: User Manual
User Manual
Copyright
The documentation and the software included with this product are copy-
righted 2006 by Advantech Co., Ltd. All rights are reserved. Advantech
Co., Ltd. reserves the right to make improvements in the products
described in this manual at any time without notice. No part of this man-
ual may be reproduced, copied, translated or transmitted in any form or
by any means without the prior written permission of Advantech Co., Ltd.
Information provided in this manual is intended to be accurate and reli-
able. However, Advantech Co., Ltd. assumes no responsibility for its use,
nor for any infringements of the rights of third parties, which may result
from its use.
Acknowledgements
Intel and Pentium are trademarks of Intel Corporation.
Microsoft Windows and MS-DOS are registered trademarks of
Microsoft Corp.
All other product names or trademarks are properties of their respective
owners.
iii
CE
This product has passed the CE test for environmental specifications
when shielded cables are used for external wiring. We recommend the
use of shielded cables. This kind of cable is available from Advantech.
Please contact your local supplier for ordering information.
FCC Class A
Note: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environ-
ment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Opera-
tion of this equipment in a residential area is likely to cause harmful inter-
ference in which case the user will be required to correct the interference
at his own expense.
Document Feedback
To assist us in making improvements to this manual, we would welcome
comments and constructive criticism. Please send all such - in writing to:
support@advantech.com
v
ADAM-6521 Series User Manual vi
1
CHAPTER
2
Overview
This chapter gives an overview of
ADAM-6521 modules.
Sections include:
• Introduction
• Features
• Specifications
• Ordering Information
Chapter 1 Overview
1.1 Introduction
High-Speed Transmission
ADAM-6521 modules have a switch controller that can automatically
sense transmission speeds (10/100 Mbps). The RJ-45 interface can also
be auto-detected, so MDI or MDI-X is automatically selected and a cross-
over cable is not required. All ports have memory buffers that support the
store-and-forward mechanism. This assures that data is properly transmit-
ted.
Flexible Mounting
Due to its versatility and innovative design, ADAM-6521 modules can be
fixed in three ways: DIN rail, panel and piggyback mounting.
1.2 Features
3 Chapter 1
1.3 Specifications
Communications
Standard IEEE 802.3, IEEE 802.3u, 802.3x
LAN 10/100Base-T, 100Base-FX
Transmission Distance Ethernet: 100 m
Fiber: ADAM-6521: 2 km
ADAM-6521/ST: 2km
ADAM-6521S: 15 km
Transmission Speed Ethernet: up to 100 Mbps
Fiber: 100 Mbps
Interface
Connectors 4 x RJ-45, 1 x SC type fiber connector
(ADAM-6521, ADAM-6521S) or 1 x ST
type fiber connector (ADAM-6521/ST)
LED Indicators Power, Link (100Base-FX),
100/10M (Ethernet)
Power
Power Connectors 2-pin removable screw terminal
Power Consumption ADAM-6521: Max. 3 W
ADAM-6521/ST: Max. 3 W
ADAM-6521S: Max. 4 W
Power Input Unregulated 10 ~ 30 VDC
Mechanism
Dimensions (W x H x D) 70 x 112 x 27 mm
Enclosure IP30, ABS+PC with solid mounting kits
Mounting DIN 35 rail, stack, wall
Protection
ESD Protection 4,000 VDC (Ethernet)
Surge Protection (EFT) 3000 VDC (Power)
Certifications
Safety UL 60950-1, CAN/CSA-C22.2 No.60950
EMC U.S.A.: FCC Part 15 CISPR 22
EU: EN55011, EN55022 Class A,
EN61000-3-2/3, EN55024
IEC61000-4-2/3/4/5/6/8/11
• ADAM-6521
Industrial Switch with 4 10/100 Mbps Ethernet Ports & 1 Multi-mode
SC Type Fiber Optic Port
• ADAM-6521/ST
Industrial Switch with 4 10/100 Mbps Ethernet Ports & 1 Multi-mode
ST Type Fiber Optic Port
• ADAM-6521S
Industrial Switch with 4 10/100 Mbps Ethernet Ports & 1 Single-mode
SC Type Fiber Optic Port
5 Chapter 1
ADAM-6521 Series User Manual 6
2
CHAPTER
2
Installation
In this chapter, you will be given an
overview of the ADAM-6521 series
hardware installation procedure.
Sections include:
• LED Indicators
• Dimensions
• Mounting the Module
• Connections
Chapter 2 Installation
2.1 LED Indicators
There are six network status LEDs located on the top panel of the
ADAM-6521 modules. Their meaning is displayed in Table 2.1
below.
Panel Mounting
ADAM-6521 modules can be attached to a wall using the included brack-
ets. Each bracket comes with four screws; first attach the bracket to the
bottom of the ADAM-6521 module. Next, screw the bracket to the wall.
Piggyback Stack
Several ADAM-6521modules can be stacked as seen in the figure below.
13 Chapter 2
ADAM-6521 Series User Manual 14