INSTRUCTION: Select the correct answer for each of the following questions.
Mark only one answer for each item by shading the box corresponding to the
letter of your choice on the answer sheet provided. STRICTLY NO ERASURES
ALLOWED.
MULTIPLE CHOICE
2. What is the minimum number of LAV for 200 males? (Assembly Places -
Theatres, Auditoriums, Convention Halls, etc. - for permanent employee
use)
a. 2 c. 4
b. 3 d. 5
3. The invert of the inlet pipe shall be at a level not less than ____ above
the invert of the outlet pipe.
a. 32 mm c. 40.8 mm
b. 38 mm d. 50.8 mm
4. The pipe or tubing that connects the outlet of a plumbing fixture to the
trap.
a. trap c. tailpiece
b. trap arm d. outlet
8. All sections of a plumbing drainage and vent system must be tested with
a. water c. air or water
b. any liquid d. air
11. What is the minimum number of WC for 100 males? (Assembly Places -
Theatres, Auditoriums, Convention Halls, etc. - for public use)
a. 1 b. 2
c. 3 d. 4
12. Inlet and outlet pipe fittings or baffles, and compartment partitions
shall have a free vent area _______ of the house sewer or private sewer
discharging therein to provide free ventilation above the water surface
from the disposal field or seepage pit through the septic tank, house
sewer, and stack to the outer air.
a. equal to the required cross-sectional area
b. 1.5 times the required cross-sectional area
c. twice the required cross-sectional area
d. 2 ½ times the required cross-sectional area
13. A branch vent that performs its functions for two (2) or more traps.
a. vent system c. individual vent
b. relief vent d. group vent
14. What is the minimum pressure required to test water supply system?
a. 100% of used water pressure c. 200% of used water pressure
b. 150% of used water pressure d. 250% of used water pressure
16. That part of plumbing system extending from point 0.6-m of the inner
face of the foundation wall of building to the junction with another
sewer.
a. house sewer c. sanitary sewer
b. storm sewer d. building drain
17. The air test for a plumbing drainage and vent system shall be made by
attaching the air compressor or other test apparatus to
a. The lowest fixture outlet c. Any suitable opening
available d. A dishwasher waste opening
b. The highest vent opening
21. The side walls shall extend at least ___ above the liquid depth.
a. 304.8 mm c. 228.6 mm
b. 50.8 mm d. 104.6 mm
22. Any joint or seam obtained by the joining of metal parts in a plastic
molten state.
a. welded joint c. both a & b
b. seam d. none of the above
23. What do you call to the combination of two elements, hydrogen and
oxygen?
a. ice c. liquid
b. water d. fluid
24. What is the maximum distance allowed for the trap of the floor drain to
be placed below the finished floor line to facilitate cleaning in case of
line trouble?
a. 300 mm c. 500 mm
b. 400 mm d. 600 mm
25. Equipment which includes all valves and controls used in the plumbing
system which are required to be accessible or readily accessible.
a. Machine c. Regulating Equipment
b. Controls d. Pipes
27. When floor drainage is required for a cold storage room used for storing
or holding food or drink, the drain must be connected to the sanitary
drainage system through a
a. direct waste c. trap with trap primer
b. floor drain with strainer d. indirect waste
28. Who shall appoint the Board of Examiners for Master Plumber?
a. Commissioner of Civil Service c. President of the Philippines
b. PRC Commissioner d. BOMP
29. When provided with water outlets for such space, a 610 mm width of wash
sink or 457 mm diameter of a circular basin, shall be _____.
a. considered equivalent to one lavatory
b. considered equivalent to one water closet
c. considered equivalent to one kitchen sink
d. considered equivalent to one floor drain
30. The cover of the septic tank shall be at least ____ above the back-vent
openings.
a. 304.8 mm c. 228.6 mm
b. 50.8 mm d. 106.6 mm
31. The vertical distance from the “Grade Line” to the highest point of the
coping of a flat roof or to the top line of a mansard roof or to the
average height of the highest gable of a pitch or hip-roof.
a. Branch interval c. Storey
b. Height of building d. None of the above
36. The maximum height above the trap for a clothes washer standpipe
receptor is ____.
a. 0.45 m c. 0.75 m
b. 0.60 m d. 0.80 m
37. Who is authorized to issue rules and regulations to carry into effect
the objectives of RA 1378?
a. Commissioner of Civil Service c. President of the Philippines
b. PRC Commissioner d. BOMP
38. Where food is consumed indoors, water stations may be substituted for
drinking fountains. Offices, or public buildings for use by more than six
persons shall have one drinking fountain for the first 75 persons and one
additional fountain __________.
a. for each 100 persons thereafter
b. for each 120 persons thereafter
c. for each 150 persons thereafter
d. for each 200 persons thereafter
44. A horizontal waste and vent pipe which is sized to provide free
circulation of air above the flow line of the drain pipe.
a. Combination waste and vent system
b. Continuous wet vent system
c. Nonsolvent waste and vent system
d. Ventilating piping system
45. The minimum height above the trap for a domestic clothes washer
standpipe receptor is _____ inches.
a. 16 c. 20
b. 18 d. 22
46. Section 6 of RA 1378 states that each member of the Board shall, at the
time of his appointment:
a. be a citizen and resident of the Philippines
b. be at least thirty years of age and of good moral character
c. has been actively engaged in the trade of master plumber for at least
five years.
d. All of the above
49. Any branch in a building drain other than the primary branch.
a. Horizontal branch c. Secondary branch
b. Lateral branch d. Branch interval
50. What do you call to this device that is used to measure the amount of
water that passes through the water service?
a. multimeter c. water counter
b. water tank d. water meter
51. What is the minimum size of the drain pipe for the water closet to
discharge into?
a. 2 inches c. 4 inches
b. 3 inches d. 2-1/2 inches
52. The maximum fixture unit loading allowed on 2-inch waste stack is:
a. Four c. Sixteen
b. Six d. Eight
54. The trap for a clothes washer must be roughed-in less than _____ inches
above the floor.
a. 4 c. 8
b. 6 d. 10
55. Under Section 9 of RA 1378 who shall be the executive officer of the
Board, and shall conduct the examinations given by the board and shall
designate any subordinate officer of the Bureau of Civil Service to act
as secretary of the Board?
a. Commissioner of Civil Service c. President of the Philippines
b. PRC Commissioner d. BOMP
a. equal c. 3 times as
b. 2 times as d. 4 times as
58. It is a cast iron soil pipe with plain ends connected together with
bolted stainless-steel bands and neoprene gaskets.
a. IPS c. single hub
b. double hub d. hubless
59. This is a valve used for controlling two or more outlets in a cold water
supply line.
a. heavy duty gate valve c. foot valve
b. full way gate valve d. globe valve
60. According to NPCP, at least _____ of the vertical stacks in the plumbing
system must be extended full size through the roof.
a. 4 c. 2
b. 3 d. 1
61. What valve is required a head of each water supplied appliance, each
slip joints or nonmetallic connection?
a. Flow valve c. Control valve
b. Check valve d. Butterfly valve
64. Every building having plumbing fixtures installed and intended for human
habitation, occupancy or use on premises abutting on a street, alley or
easement where there is a public sewer, shall be connected to the sewer
system.
a. Principle No. 4 c. Principle No. 6
b. Principle No. 5 d. Principle No. 7
65. ______ shall be connected to the hot and cold water distribution
supplies so that the hot water supply is located at left side of the
combination fittings.
a. Faucets and diverters c. AAV
b. Vacuum breaker d. HWT
66. The minimum wall thickness of any steel septic tank shall be _____.
a. No. 12 U.S. gauge c. No. 16 U.S. gauge
b. No. 14 U.S. gauge d. No. 24 U.S. gauge
67. That part of the horizontal piping of sanitary drainage system which
measures 0.6 meter downstream from the last mobile home site and conveys
sewage to a public sewer, private sewer, individual sewage disposal system
or other points of disposal.
a. building sewer b. mobile home park sewer
68. What is the material not listed in the code for use in water piping?
a. plastic c. aluminum
b. cast iron d. asbestos cement
70. When pipe makes an angle of not more than 45 degrees with the vertical,
it is considered as a __________.
a. vertical pipe c. crooked pipe
b. diagonal pipe d. horizontal pipe
77. It is the lowest piping system that receives the discharge from soil,
waste and other drainage pipes.
a. building sewer c. soil pipe
b. building drain d. asbestos pipe
81. The receptors receiving the discharge of indirect waste pipes must be
of a shape and capacity that will _______.
a. prevent splashing
b. serve the intended use
c. avoid collecting solids
d. intercept ingredients harmful to the building drainage system
85. It is inserted into the water main and it serves as the control of the
water service.
a. curb stop c. water stop
b. corporation stop d. meter stop
87. A joint made by firmly packing with oakum and filled with molten lead
to a depth of not less than one inch.
a. steel pipe
b. cast iron no hub pipe
c. plastic pipe
d. cast iron bell and spigot soil pipe
88. Every passageway to an attic water heater shall have a solid continuous
flooring not less than ___________.
a. 36 inches wide c. 60 inches wide
b. 48 inches wide d. 24 inches wide
89. Every building in which plumbing fixtures are installed shall have
connection to a __________.
a. drywall c. storm sewer
b. cesspool d. public or private sewer
92. Assume you are installing a waste pipe for a culinary sink. The pipe is
a 1 ½-inch copper pipe. The code requires that the sink be protected from
backflow. In order to pass inspection, you must provide _______.
a. A check valve c. A backwater valve
b. An air gap d. A vacuum breaker
93. The drain pipe from a refrigerator must drain into an ________.
a. Approved dry well c. Open floor sink
b. Catch basin d. Service sink
97. Consists of a loaded air inlet valve, an internally loaded check valve,
two properly located test cocks and two isolation gate valves.
a. DC c. RP
b. PVB d. AVB
98. Clean stone, gravel, slag, or similar filter material acceptable to the
Administrative Authority, varying in size from ______ shall be placed in
the trench to the depth and grade required by this section.
a. 38 mm to 102 mm c. 12.5 mm to 51 mm
b. 32 mm to 76 mm d. 19.1 mm to 64 mm
99. When seepage pits are used in combination with disposal fields, the
filter material in the trenches shall terminate at least ______ from the
pit excavation and the line extending from such points to the seepage pit
shall be approved pipe with watertight joints.
a. 1.2 m c. 2.0 m
b. 1.5m d. 3.0 m
100. A combination of elbows or bends that brings one section of the pipe
out of line but into a line parallel with the other section.
a. Offset c. Both a & b
b. Set d. Neither
END