XIAL FLOW FAN - Direct Driven: Tda - M
XIAL FLOW FAN - Direct Driven: Tda - M
XIAL FLOW FAN - Direct Driven: Tda - M
TDA - M
CASED
Construction
Cheaper construction with shorter double flanged casing,
is produced in mild steel or galvanised steel, the impeller
having manually adjustable pitch blades is made of PPG,
PAG or Aluminium.
Finish
Painting or galvanised after manufacture are normal finishes
on all parts.
Operating Temperature
-20°C to +55°C
Motors
Totally enclosed Class ‘F’ motor, to a min. IP54 protection are
are fitted as standard. Standard motor up to 2.2kW are usually
supplied on DOL starting, motor 3.0kW and above are star/
delta starting.
Airflow Direction
Air flowing from impeller to motor are fitted as standard. Air
flowing from motor to impeller can be supplied on request.
Option
Spark resistance construction in accordance to AMCA
standard 99-0401-86 type C construction can be supplied
upon request.
D
N° x Ø
ØC
ØA
ØB
315 315 355 395 200 8 10 6 D71 710 710 755 810 406 18 12 30 D112M
355 355 395 435 200 8 10 7 D80 800 800 845 900 406 18 12 40 D132M
400 400 440 480 235 12 10 7.5 D90S 900 900 945 1000 495 18 12 51 D160M
450 450 490 530 255 12 10 8 D90L 1000 1000 1050 1100 550 24 12 57 D160M
500 500 540 580 285 12 10 11 D90L 1120 1120 1185 1250 650 24 12 96 D225M
560 560 605 660 346 12 10 16 D112M 1250 1250 1315 1380 700 24 12 147 D250M
630 630 675 730 346 12 10 18 D112M 1400 1400 1465 1530 770 32 14 171 D250M
* Motor frame size beyond this range, please consult KRUGER for details --- Weight without motor and impeller. LEA006.E1-03/06
QUICK SELECTION GUIDE – 50 Hz
2 POLES - 2800 RPM
Hst (Pa)
1400
1200
1000
800 630
560
600
500
450
400
400
355
200 315
0 1 2 3 4 5 6 7 8
Air Flow (M3/S)
Hst (Pa)
320
280
240
630
200
560
160
500
120
450
80 400
40 355
315
Hst (Pa)
1200
1000
800
1250
1120
600
1000
400
900
800
200 710
0 3 6 9 12 15 18 21 24 27 30
Air Flow (M3/S)
*** Shaded portion is the recommended operating range based on the duct velocity consideration (friction loss of 1 Pa/m)
QUICK SELECTION GUIDE – 50 Hz
6 POLES - 900 RPM
Hst (Pa)
210
180
150
120
800
90
710
60 630
560
30 500
450
0 1 2 3 4 5 6 7 8
Air Flow (M3/S)
500
1400
400
1250
300
1120
200
1000
100 900
0 5 10 15 20 25 30 35
Air Flow (M3/S)
Hst (Pa)
400
350
300
1400
250
1250
200
150 1120
100
4 POLES - 1750 RPM1000
900
50 800
0 3 6 9 12 15 18 21 24 27 30
Air Flow (M3/S)
*** Shaded portion is the recommended operating range based on the duct velocity consideration (friction loss of 1 Pa/m)
QUICK SELECTION GUIDE – 60 Hz
4 POLES - 1750 RPM
Hst (Pa)
1200
1000
1000
800
900
600
800
400 710
560
630
500
200 450
400
355
0 2 4 6 8 10 12 14 16 18
Air Flow (M3/S)
Hst (Pa)
350
300
250
800
200
710
150
630
100 560
500
450
50
0 1 2 3 4 5 6 7 8
Air Flow (M3/S)
Hst (Pa)
1000
900
800
1400
700
600 1250
500 1120
400
300 1000
200 900
100
0 5 10 15 20 25 30 35 40
Air Flow (M3/S)
*** Shaded portion is the recommended operating range based on the duct velocity consideration (friction loss of 1 Pa/m)