APD165P
APD165P
APD165P
165kVA / 132 kW
POWERED by PERKINS
MODEL APD165P
kVA 165
Standby
Power kW 132
Pf. 0.8 kVA 150
Prime
kW 120
Standby: Continuous running at variable load for duration of an emergency. No overload is permitted on these ratings. In accordance with ISO 3046 .
Prime: Continuous running at variable load for unlimited periods with 10% overload available for 1 hour in any 12 hour period. In accordance with ISO 8528,ISO 3046.
Manufacturer reserves the right to make changes in model, technical specifications, color, equipment and accessories without prior notice.
www.aksapowergen.com
ENGINE
PERKINS
Model 1106A-70TAG2
Engine Power Output kWm 153.6
at rated rpm HP 206
Aspiration and Cooling Turbocharged and air charge cooled
Total Displacement Litre 7.01
No. of Cylinders and Build 6 ; In-line
Engine Speed rpm 1500
Bore and Stroke mmxmm 105×135
Compression Ratio 16:1
Governor Mechanical
Fuel Consumption at full load L/hr 33.4
Fuel Tank Capacity Litre 340
Oil Capacity Litre 18
Coolant Capacity Litre 21
Radiator Cooling Air m³/min 252
Air Intake – Engine m³/min 10.67
Exhaust Gas Flow m³/min 25.53
Heavy duty Perkins diesel engine Cooling radiator and fan
Four stroke, water cooled, turbocharged & air charge cooled Starter battery (with lead acid) including Rack and Cables
Direct injection fuel system Flexible fuel connection hoses and manual oil sump drain valve
Mechanical Governor system Industrial capacity exhaust silencer and steel bellows
12/24 V D.C. starter and charge alternator Jacket water heater(at automatic models)
Replaceable fuel filter, oil filter and dry element air filter Operation manuals and circuit diagram documents
ALTERNATOR
Design Brushless single bearing, revolving field
Stator 2/3 pitch
Rotor Single bearing, flexible disc
Insulation System Class H
Standard Temperature Rise 125 - 163°C Continuous
Exciter Type Self Excited
Phase Rotation A (U), B (V), C (W)
Alternator Cooling Direct drive centrifugal blower fan
AC Waveform Total Harmonic Distortion No load < 1.5%. Non distorting balanced linear load < 5%
Telephone Influence Factor (TIF) <50 per NEMA MG1-22.43
Telephone Harmonic Factor (THF) <2%
Brushless, single bearing system, flexible disc, 4 poles Impregnation with tropicalised epoxy varnish
Insulation class H Solid state Automatic Voltage Regulator
Standard degree of protection IP21 (*IP22/IP23 is available.) Stator winding with 2/3 pitch for improved harmonics
Self-exciting and self-regulating
www.aksapowergen.com
CONTROL SYSTEM
Control supervision and protection panel is mounted on the genset base frame.
The control panel is equipped as follows:
OPTIONAL EQUIPMENTS
www.aksapowergen.com
CHASSIS
The complete gen-set is mounted as whole on a heavy-duty fabricated, steel base frame
Anti-vibration pads are fixed between the engine/ alternator feet and the base frame
Base frame design incorporates an integral fuel tank (Up to 750 kVA)
The generating set can be lifted or carefully pushed / pulled by the base frame
Dial type fuel gauge and drain plug on the fuel tank
Forklift pockets within base frame (up to 500kVA)
DIMENSIONS
OPEN TYPE
DIMENSIONS (LxWxH) mm 2300x1080x1667
DRY WEIGHT kg 1510
CANOPY
All canopy parts are designed with modular principles Exhaust silencer is protected against environment influences
Without welding assembly Thermally insulated engine exhaust system
Doors on each side Emergency stop push button is installed outside of the canopy
All metal canopy parts are painted by electrostatic Easy lifting and moving
polyester powder paint Easy maintenance and operation