SPRD Writeimei Tool User Guide
SPRD Writeimei Tool User Guide
SPRD Writeimei Tool User Guide
Catalog
1. Interface Description.............................................................................3
1
2
The items and its function of main user interface are shown in Table 1-1.
From data file is chosen to get the IMEI from an excel file in which there must be
a table called IMEI and the IMEI numbers are listed in the first column.
If Custom number is chosen, you have to input the initial IMEI in the initial
number and designate the position to be generated automatically in the mask.
Attention: Initial number and mask must match and * represents the position to be
generated automatically. Max limited number is used for “From data file” and
“Custom number”. It means that you can’t add any IMEI when it has imputed that
number of IMEI.
The max limited number is used to limit the number of IMEI written to the phone
in from data file mode and custom mode.
Default IMEI is used in default mode.
Note:
Except for the manual input mode, the other generation modes support continuous plug operation,
that is, after the completion of the write, the phone will be pulled down, the program will
automatically detect whether there is a new device connected to the port.
Note:
Except for the manual input mode, the other generation modes support continuous plug operation,
that is, after the completion of the write, the phone will be pulled down, the program will
automatically detect whether there is a new device connected to the port.
Manual input is chosen to input the SN with the keyboard or a scanner. The input
BT number must be composed of legitimate numbers or letters, if it is invalid,
there will be a corresponding prompt.
Automatic mode: automatically generate BT number according to the time or the
address.
Note:
Except for the manual input mode, the other generation modes support continuous plug operation,
that is, after the completion of the write, the phone will be pulled down, the program will
automatically detect whether there is a new device connected to the port.
2. Operation Guide
2.1 Quick Start Guide
1. Running
Run WriteImei.exe. The main interface is shown as Figure 1-1.
2. Select port/device
The port name will automatically display on the port button after the mobile
phone successfully connected. If connection failed, it will display “port (none)”, as
shown in Figure 2-1.
3. Parameter setting
Click setup button on the main interface to open setup dialog. Set the phase
check and other parameter, as shown in Figure 1-2.
4. Begin to write
Click the start button on the main interface.
Version Check description
1) Check operation
Version input box cannot be empty;
If version check failed, the check operation cannot be carried out.
2) Read operation
If the version input box is not empty, then the version check will be
carried out. The read operation cannot be carried out if the version check
is failed.
If the version input box is empty, then version read will be carried out
and the result will be shown in the version box.
5. Writing complete
The information box output information and the status box will also show
unmount, idle, writing, finished or error during the writing process.
Figure 2-2 Different status during writing