EM6400 Series Multi-Function Meters

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

EM6400 series

Multi-Function meters
1 Digital display & Analog load bar indicators
2 Bright Red LED display

3 Global: CE, UL marks

4 Universal

Demand Quick and easy Turbo Key


Monitoring installation
EM6400 series
Multi-Function meters
Features
EM6400 series meters are ideal replacements for analog meters. Use for standalone
metering in custom panels, switch boards, switch gear, gensets, motor control centers and
Auto Scaling K, UPS systems.
M and G
Brilliant 3 line, Easy to use
8 segment LED display
n Fast setup via display or software
Color coded analog
load bar Measurements
n True RMS electrical parameters: per phase voltage, current, demand, W, VA, VAr
n Integrated parameters: kWh, kVARh, kVAh
n Neutral current, frequency, Power Factor, % Load, % Unbalance (V&I), Phase angle
n Onhours, Runhours & Interrupts.
EM6400 n 4 Quadrant energy : bi-directional, absolute & net
n Demand: sliding & fixed block
n Options for Class 1.0, 0.5, 0.5S & Cl 0.2 meters as per IEC 62052-11, IEC 62053-21,
IEC 62053-22 & ANSI Cl12.20
n Total Harmonic Distortion (THD) measurement for both Voltage and Current circuit, per
phase

Communications
n RS-485 port, Modbus RTU for integration with energy management systems

Certifications
n UL listed (US & Canada), CE, C-Tick certified

Front panel display


EM6459
n Alpha numeric bright display
n Brilliant 3 line, 4 digit per line, (digit height 14 mm)
n LED display with auto-scaling capability for kilo, Mega, Giga
n View 3 parameters together
n Password protection for setup parameters
n User selectable default display page through keypad lock

Benefits
EM 6459
n Displays Volts, Amps, Frequency, PF simultaneously
n Monitors generator speed (RPM)
n Monitors generator loading efficiency
EM6433 n ON hours & number of power interruptions

Applications EM 6434
n Displays all power and energy parameters, Run hours,
n Control Panels
ON hours & number of power interruptions
n Motor Control Centers
n Monitors loading characteristics of motors
n Power Distribution Panels
n Connection to Plant Monitoring & Control Systems
EM 6433
n Genset Panels
n Monitors active/apparent power & energy consumption,
n Original Equipment Manufactures (OEMs)
load current, Run hours, ON hours in a single meter
n Building Management System
n Displays Amps, Power simultaneously
User Programmable
EM 6436
n Delta / Star (Wye) / 2 Phase / 1 Phase
All benefits of EM 6433 and more
n PT, CT Ratios Primary & Secondary
n Displays Volts, Amps, Frequency/PF simultaneously
n User selectable VAh/Wh (EM6436, EM6433)

Rugged Construction EM 6400


All benefits of the above models and more
Conforms to
n Monitors all instantaneous, integrated and demand parameters
Emission : CISPR22 n Helps energy balancing
Fast Transient : 4 kV IEC 61000-4-4
Surge withstand : 4 kV IEC 61000-4-5
ESD : 15 kV Air discharge, 8 kV
Contact discharge IEC 61000-4-2
Impulse voltage : 6kV, 1.2/50μSec, IEC 60060
Safety Construction : Self extinguishable V0 plastic
Protection against : Front IP 51
Rear IP 30
Technical Specification Overload

Sensing/ : True RMS, 1 sec update time 4 Quadrant


Measurement Power & Energy

Accuracy : Class 1.0 as per IEC 62052-1 1 and


IEC 62053-21
Class 0.5 & 0.5S (optional) as per IEC
62052-1 1, 62053-22 and ANSIC12. 20
Class Cl 0.2 (optional) as per IEC 62052-11
and IEC 62053-22

Aux Supply : 44 to 300 Vac/dc


(Control Power)

Input voltage : 4 Voltage inputs (V1, V2, V3, VN) 110 or


415 Vac LL nominal(Range 80 to 600 Vac LL)
Models v3.03

Input current : Current inputs (A1, A2, A3)


Parameter EM EM EM EM EM
(Energy 5 A Class 1.0|0. 5: 5 mA (Starting) to 6 A* 6459 6433 6434 6436 6400
Measurement) 5 A Class 0.5S|0.2: 5 mA (Starting) to 6 A
V V1 V2 V3 V12 V23 V31
1 A Class 0.5S|0.2: 1 mA (Starting) to 1.2 A
A A1 A2 A3
Overload : 5 A meter : 10 A max continuous An Neutral Current C C
1 A meter : 2 A max continuous F
%Load
Burden : 0.2 VA max for each phase input voltage
and current, 3 VA max on Aux Supply %A Unbal %V UnbaU
RMS PF PF1 PF2 PF3
Frequency : 45 to 65 Hz %AFS Analog load bar
RPM
Resolution : RMS 4 digit, INTG 8 digit
A Phase Angle A°1 A°2 A°3
Communication : RS 485 serial channel connection Industry W W1 W2 W3
standard Modbus RTU protocol VA VA1 VA2 VA3
VAR VAR1 VAR2 VAR3
Isolation : 2 kVac isolation for one min between all
nd VA/ W/ A
isolated circuits including communication port
Rising demand
DM
DM

Safety : Measurement category III, Pollution Time remaining



Degree 2, Protection against shock by MD Maximum demand
double insulation at user accessible area
Hr MD occurred

Environmental : Operating Temperature Wh


-10 °C to 60 °C (40 °F to 140 °F) VAh
Storage Temperature VARh
INTG Fwd

-25 °C to + 70 °C (-13 °F to 158 °F) -VARh


Humidity 5% to 95% non condensing
Run hours
Weight : 400 gms approx. Unpacked ON hours
500 gms approx. Shipping INTR
R.Wh
Note: * For 5 A universal meter additional error of 0.05% of full scale,
R.VAh
INTG Rev

for meter input current below 100 mA


IE
For Class 0.5S and Class 0.2 meters, current inputs of 5A or 1A R.VARh

are factory set -R.VARh
Accuracy Run hours
Wh
Accuracy % of Reading
VAh
OLD Fwd

Measurement Cl 5.5
Cl 1.0 Cl 0.2
/0.5S VARh
Volts LN per .phase & Avg 1.0 0.5 0.2 -VARh
Volts LL per phase & Avg 1.0 0.5 0.2 Run hours
Amps per phase & Avg 1.0 0.5 0.2 R.Wh
Amps phase angle per phase 2° 1° 1° R.VAh
OLD Rev

Frequency 0.1 0.1 0.1 IE


R.VARh

Active Power per phase & total 1.0 0.5 0.2
-R.VARh
Reactive Power per phase & total 2.0 1.0 0.5
Run hours
Apparent Power per phase & total 1.0 0.5 0.2
V THD, per phase
THD

Active Energy Import/Export 1.0 0.5 0.2


Amps THD, per phase
Reactive Energy (Inductive/Capacitive) 2.0 1.0 0.5
Apparent Energy 1.0 0.5 0.2 Note: = Standard = Option specified while ordering
C = Only through communication
RPM 1.0 0.5 0.2
= User selectable VAH/Wh through setup mode
Note: PF error limit is same as W error limit in % (EM 6436, EM 6433)
Communication Interface RS 485 Single Point
RS 485 standard, communication capability using open Modbus Communication Modbus
RTU protocol. The meters can be multi-dropped using RS 485
twisted pair. The baud rate can be set from 1200 bps to 19200
bps. (Preferred settings is 9600 bps.)
RS 485 Half duplex isolated serial channel connection.
BMS Compatible
Access of either single (individual) parameter or block of
parameters through RS 485 communication port. Integrates
with BMS packages. RS 485
EM6400 meters are configurable with EGX gateway servers
(EGX100, EGX300 etc.,)
EM6400 series meters can be directly configured with
Schneider’s Power Monitoring Expert (PME) or SPM or ION
Enterprise Energy monitoring system softwares.

EM6400 meters can be interfaced through Modbus RTU protocol over RS-485 or TC/IP Ethernet network. Following schematic is for illustration only

RS 485

Wiring Diagram

3 Phase 4 Wire Star (wye) 3 Phase 3 Wire Delta

L1 L2 L3 N LINE L1 L2 L3
LINE

PT if VAC LL 601 V
PT if VAC LL 601 V CT
S1 CT S1
80 to 600 Vac LL
80 to 600 Vac LL

0.25 A
N998
N998

0.25 A
* *
S2
S2
CT
S1
Acc Cl: X.X
Acc Cl: X.X

*
50mA to 6A
50mA to 6A

44 to 300 V 50/60 Hz <5 VA


44 to 300 V 50/60 Hz <5 VA

S2 CT
CT Other Meters
S1 Other Meters S1
44 to 300 VAC/DC 44 to 300 VAC/DC
* * Aux Supply
Aux Supply
(Control power) (Control power)
S2
S2
D1 D0
D1 D0
LOAD RS 485
LOAD RS 485
Communication
Communication
*Other Meters (In Series)
* Other Meters (In Series)

2 Phase 3 Wire Single Phase

L1 N

LINE

CT * Other meters (in series)


* Other meters (in series) AC
S1 0.25 A
80 to 600 Vac LL
N998
80 to 600 Vac LL

*
N998

S2
Acc Cl: X.X
Acc Cl: X.X

50mA to 6A
50mA to 6A

44 to 300 V 50/60 Hz <5 VA


44 to 300 V 50/60 Hz <5 VA

Other Meters

44 to 300 VAC/DC 44 to 300 VAC/DC


Aux Supply
(Control power)

D1 D0 D1 D0
RS 485 LOAD RS 485

Communication
“3d” VA measurement Integrated Parameters
n EM 6400, EM 6433, EM 6436 is equipped with “3d VA Measurement” capability. This n Import / Export is optional. Factory selectable on
accurately include Distortion power (D) per IEEE 100, into the VA Calcution order (For EM 6400 only)
n Energy Parameter (kWh, kVAh, kVARh inductive and
kVARh Capacitive) (Total, Import & Export)
n However Arithmetic VA=VA1 +VA2+VA3 is also available as a set-up option n Separate Run hrs for Import, Export and Total
n Run hrs, ON hrs, No of interruptions

Demand Parameters Optional


(for EM 6400 only) Terminals Description

n Monitors Demand - Present, Rising & Maximum, Time remaining

D1
n VA or W or A demand is selectable through setup table 50mA to 6A
n User selectable demand interval through set up in steps of 5 minutes Acc Cl: X.X

RS 485
(5,10,15, 20, 25 & 30)
N998
n Demand may be Sliding window (auto) or Fixed window (User), selectable through setup
mode 44 to 300 V 50/60 Hz <5 VA 80 to 600 Vac LL

n The time of occurrence for the Maximum Demand is based on “ ON hrs” of the system

D0
n Maximum Demand can be cleared independently or along with the integrators through
the CLR function

Ordering Information Dimensions


Specify
Bezel : 96 x 96 mm
Depth : 80 mm behind Bezel
Model No. RS485 COM Port Panel cutout : 92+0.5x92+0.5 mm

EM 6459

EM 6433
Built-in

EM 6434
Built-in

EM 6436

Demand
EM 6400
Import/
Export 9mm additional
space on both
side of the meter
inside the Panel

Input Current Accuacy


Cl 1.0
5A Universal
Cl 0.5
Cl 0.5S
5A ION set up Software for Configuration
Cl 0. 2
Cl 0. 5S n A GUI based software tool for programing meters
1A
Cl 0.2 n Downloadable from website

Schneider Electric strives for continuous product innovation. Product


specifications are therefore subject to change without notice.
Make the most of your energySM

Schneider Electric India Pvt. Ltd.


Corporate office