Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Bab Iv Spesifikasi Bangunan Pengolahan Air Buangan IV Neraca Massa IV.1 Karakteristik Limbah Industri Kayu Lapis

Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 5

BAB IV

SPESIFIKASI BANGUNAN PENGOLAHAN AIR BUANGAN

IV Neraca Massa
IV.1 Karakteristik Limbah Industri Kayu Lapis
Q = 1250 m3/hari= 0,015 m3/detik
BOD = 400 mg/l
COD = 530 mg/l
TSS = 350 mg/l
NH3-N = 17 mg/l
Phenol = 11 mg/l
pH = 6,8
IV.2 Standart Baku Mutu Limbah Cair
BOD = 75 mg / l
COD = 125 mg/l
TSS = 50 mg/l
NH3-N = 4 mg/l
Phenol = 0,25 mg/l
pH =6–9

IV.3 Penurunan per bangunan (% removal)


a) Saluran Pembawa
% Removal = < 10 % BOD
< 10 % COD
( Sumber : Hand Out PBPAB, Ir. Yayok Suryo P., MS & Firra R., ST.,
MT)
Influent Screen
Saluran Pembawa
Input Output 2
Output 1
BOD & COD

91
Input % Output 1 Output 2 Baku Mutu
No Parameter
(mg/L) Removal (mg/L) (mg/L) (mg/L)
1 BOD 400 1 4 396 75
2 COD 530 1 5,3 524,7 125
3 TSS 350 - - 350 50
4 NH3-N 17 - - 17 4
5 Phenol 11 - - 11 0,5
6 Ph 6,8 - - 6,8 6-9

b) Screen
% Removal = 20 - 35 % TSS
20 - 35 % BOD
` 20 - 35 % COD
(Sumber : Metcalf & Eddy, WWET Disposal, and Reuse 4 nd edition
1979, page 327)
Saluran Pembawa Grit Chamber
Screen
Input Output 2
Output 1
BOD, COD, TSS

Input % Output 1 Output 2 Baku Mutu


No Parameter
(mg/L) Removal (mg/L) (mg/L) (mg/L)
1 BOD 396 20 79,2 316,8 75
2 COD 524,7 30 157,41 367,29 125
3 TSS 350 35 122,5 227,5 50
4 NH3-N 17 - - 17 4
5 Phenol 11 - - 11 0,5
6 Ph 6,8 - - 6,8 6-9

92
c) Koagulasi - Flokulasi
% Removal = 58% BOD
63% COD
33% TSS
(Sumber : Elkenfelder, page 156 )

Screen Activated Sludge


Koa-Floka
Input Output 2
Output 1
TSS BOD COD

Input % Output 1 Output 2 Baku Mutu


No Parameter
(mg/L) Removal (mg/L) (mg/L) (mg/L)
1 BOD 316,8 58 183,74 133,06 75
2 COD 367,29 63 231,39 135,9 125
3 TSS 227,5 33 75,07 152,43 50
4 NH3-N 17 - - 17 4
5 Phenol 11 - - 11 0,5
6 Ph 6,8 - - 6,8 6-9

d) Activated Sludge
% Removal = 85 - 95 % BOD
80 - 85 % COD
95 - 99 % PHENOL
33 - 99 % NH3-N
(Sumber : Metcalf & Eddy, WWET Disposal, and Reuse 4 nd edition,
page 484, 337 & 396 dan Cavaseno, Industrial Wastewater and Solid
Waste Engineering, page 15)

93
Koa - Floka Bak Pengendap II
Activated Sludge
Input Output 2
BOD,COD , PHENOL, NH3-N
Output 1

Input % Output 1 Output 2 Baku Mutu


No Parameter
(mg/L) Removal (mg/L) (mg/L) (mg/L)
1 BOD 133,06 85 113,10 19,96 75
2 COD 135,9 80 108,72 27,18 125
3 TSS 152,43 - - 152,43 50
4 NH3-N 17 90 15,3 1,7 4
5 Phenol 11 99 10,89 0,11 0,5
6 Ph 6,8 - - 6,8 6-9

e) Bak Pengendap II (Secondary Clarifier)


% Removal = 50 - 70 % TSS
25 - 40 % BOD
25 - 40 % COD
(Sumber : Syed R. Qasyim, WWTP, Planing, design and operation,
page 66)

Activated Sludge Bak Pengendap II Badan Air Penerima

Input Effluent
Output 1

94
COD, BOD & TSS

Input % Output 1 Output 2 Baku Mutu


No Parameter
(mg/L) Removal (mg/L) (mg/L) (mg/L)
1 BOD 19,96 - - 19,96 75
2 COD 27,18 - - 27,18 125
3 TSS 152,43 70 106,70 45,73 50
4 NH3-N 17 - 15,3 1,7 4
5 Phenol 11 - 10,89 0,11 0,5
6 Ph 6,8 - - 6,8 6-9

95