Fault Code Fault Name: NCD Inducement Fault Level1 (Group4 - DEF Quality)

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 2

DOOSAN G2 Stage5 (De-tier) Trouble shooting guide

Revision v.1.64
PAGE 657 / 933

Fault Code Fault Name


P12F2 NCD inducement Fault Level1 (Group4 – DEF Quality)
1) Overview

“E” SPN-FMI REASON EFFECT


Torque reduction
E520736-12 1. NCD inducement Fault Level1 (Group4 – DEF Quality) according to NCD
inducement strategy

2) Component Location
The NCD inducement strategy is dependent on machine variant. (Below table is base strategy.)

3) Condition for Running Diagnostic


Key on or engine running or Key off(ECU on)

4) Condition for Setting the Fault Code


The inducement Level 1 is activated by DEF quality group fault and the fault is currently present.
This fault is only intended to inform about the NCD inducement status.
Check the other faults that have occurred together to determine why the NCD inducement was active.

5) Condition for Clearing the Fault Code


The root cause of NCD inducement group fault is healed.

6) Check List
Standard
Step Inspection YES NO
Value

1 P12F2 is detected on service tool? Step2

2 Let the machine be in safety area, and key OFF Step 3


Check and fix faults related NCD inducement group Problem Contact
3
(DEF quality) Solved Helpdesk

Copyright by Doosan Infracore Co., Ltd. Rights Reserved.


DOOSAN G2 Stage5 (De-tier) Trouble shooting guide
Revision v.1.64
PAGE 658 / 933

Erase the fault & re-check fault state after fixing related
faults.
Fault is cleared?

Copyright by Doosan Infracore Co., Ltd. Rights Reserved.