DK HPN Series

High Pressure Compressed Air Dryers

This design achieves a hyper-efficient 100 %


contact between the air and refrigerant circuits,
delivering state-of-the-art performance and
great cooling efficiency.

The state-of-the-art 3-in-1 design features very


low differential pressure delivering significant
energy savings. The 3-in-1 Heat-Exchanger is
compactand allows the dryer to be smaller
and reduces the space required for the dryer.
Dalgakıran offers a variety of 3-in-1 dryers
equipped with the 3-in-1 Heat-Exchanger
to meet a full range of capacity and power
requirements.
THE SEPARATOR EFFICIENCY
Double centrifugation due to the bottom fin
Reserved direction for the compressed air
Gravity effect to the condensed water
Special anti-return system
Integrated separator

REFRIGERANT CIRCUIT
Two valve regulation system (thermal and by-
pass), allowing to fill properly the exchanger and
giving a max. temperature to the exchanger
High quality security test of potential leakage
Use of hermetic compressor as standard
High quality, long lasting components
Dalgakıran DK HPN range High Pressure Air Quick start and reaction time
Dryer Series have stainless steel brazed plate
heat exchanger. It is designed for high pressure
air dryers. The heat exchanger has the following
sections in one module;

Air/Air heat exchanger (Economizer)


Air/Refrigerant heat exchanger (Evaporator)
Water separator

SCROLL COMPRESSOR
With reliable stainless steel and optimized
Better coefficient of power
design, Dalgakıran DK HPN heat exchangers
Less energy consumption
supply size reduction, anti corrosion and great
Higher resistance to liquid shocks
heat transfer.

www.dalgakiran.com
DK HPN Series
High Pressure Compressed Air Dryers

TECHNICAL DATA
Maximum Maximum Maximum
Capacity* Connection Working Ambient Inlet Dimensions (mm) Weight
Model Voltage Pressure Temperature Temperature
Size
m3/min cfm bar 0
C 0
C Length Width Height Kg

DK 50 HPN 0,83 29 G ¾” 230V/1/50 Hz 45 45 50 454 361 553 36

DK 90 HPN 1,50 53 G ¾” 230V/1/50 Hz 45 45 50 454 361 553 38

DK 150 HP 2,50 88 G ¾” 230V/1/50 Hz 45 45 50 453 401 623 45

DK 220 HPN 3,67 130 G ¾” 230V/1/50 Hz 45 45 50 453 401 623 45

DK 300 HPN 5,00 177 G 1 /4”


1 230V/1/50 Hz 45 45 50 505 451 761 70

DK 400 HPN 6,67 236 G 1 /4”


1 230V/1/50 Hz 45 45 50 505 451 761 72

DK 500 HPN 8,33 294 G 1 1/4” 230V/1/50 Hz 45 45 50 505 451 812 78

DK 575 HPN 9,58 338 G 1 /4”


1 230V/1/50 Hz 45 45 50 505 451 812 80

DK 775 HPN 12,9 456 G 1 /4”


1 230V/1/50 Hz 45 45 50 675 501 984 115

DK 910 HPN 15,2 537 G 1 1/4” 230V/1/50 Hz 45 45 50 675 501 984 120

DK 1000 HPN 16,7 590 G 2” 230V/1/50 Hz 45 45 50 947 727 1170 218

DK 1160 HPN 19,4 685 G 2” 230V/1/50 Hz 45 45 50 947 727 1170 220

DK 1500 HPN 25,0 883 G 2” 230V/1/50 Hz 45 45 50 947 727 1170 225

DK 1600 HPN 26,7 943 G 2” 400V/3/50Hz 45 45 50 947 797 1460 263

DK 1800 HPN 30,0 1059 G 2” 400V/3/50Hz 45 45 50 947 797 1460 265

DK 2200 HPN 36,7 1296 G 2 1/2” 400V/3/50Hz 45 45 50 1162 797 1495 352

DK 2500 HPN 41,7 1473 G 2 /2”


1
400V/3/50Hz 45 45 50 1162 797 1495 353

DK 2700 HPN 45,0 1589 G 2 /2”


1
400V/3/50Hz 45 45 50 1162 797 1495 355

DK 3000 HPN 50,0 1766 G 2 1/2” 400V/3/50Hz 45 45 50 1162 797 1495 422

DK 3300 HPN 55,0 1942 G 2 1/2” 400V/3/50Hz 45 45 50 1162 797 1495 423

DK 3600 HPN 60,0 2119 G 2 /2”


1
400V/3/50Hz 45 45 50 1162 797 1495 425

- DALGAKIRAN reserves its rights to change the specifications without any prior nitice.

* Nominal flow is calculated at the following conditions: Inlet Pressure: 40 bar, Inlet Temperature: 35°C Ambient Temperature 25°C for other conditions please refer to the

correction factor table.

PRE FILTER (X) FINE FILTER (Y) ACTIVATED CARBON


PARTICLE FILTER (P) FILTER (A)
Efficiency rating:
Efficiency rating: Efficiency rating: Efficiency rating:
5 Micron particle
1 Micron particle 0.01 Micron particle 0.01 Micron particle
removal
removal & 0.5mg/m3 removal & 0.01mg/m3 removal & 0.003 mg/m3
(removes desiccant
oil removal oil removal oil removal
particles after the dryer)

CORRECTION FACTORS FOR DK-HPN SERIES


DK HPN Dryer Sizing Example;
Pressure (bar) 20 25 30 35 40 45 - - - If a compressor delivers 20 m3/min at 35 bar,
the dryer inlet temperature is 40OC and the
DOWNSTREAM BROCHURE EN REV.01

F1 0,84 0,91 0,93 0,96 1 1,02 - - - ambient temperature is 30OC, please choose
Ambient Temperature (OC) - - - - 25 30 35 40 45 your dryer as follows;
F2 - - - - 1 0,93 0,87 0,82 0,79
Dryer Capacity = 20 / 0,96 / 0,82 / 0,63 = 40,3 m3/min
Inlet Temperature ( C)O
- - - - 35 40 45 50 -
The correct dryer model for this application is
F3 - - - - 1 0,85 0,72 0,63 -
DK 2500 HPN.