Manual Tong Cat. IV
Manual Tong Cat. IV
CUSTOMER Advance Energy Systems REPORT NO. 5010051899-MT-001 DATE 01-Mar-2022 PAGE 1
DESCRIPTION OF ITEM BV-100 Manual Tong Assembly IDENTIFICATION NUMBER Asset No: 266046
MEASURED ACCEPT.LIMIT
PART / SECTION RESULT/ COMMENT
VALUE MIN/MAX
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PLAY BETWEEN LEVER & JAW (B) N/A MAX 1.12 mm N/A
Manufacturer: B+V(Forum) Size & Model : BV-100 Capacity: N/A INSPECTION RESULT/ COMMENTS
Photo of item section with ID No. Manual tong rejected, Field welding found on the Jaw parts and Found parts from
F.1461
Rev.0
05.06.2017
ALMANSOORI INSPECTION SERVICES
RIG EQUIPMENT INSPECTION CHECKLIST
EQUIPMENT NAME Manual Tong
COMPLIANCE TO THE
SR# INSPECTION CHECK POINTS STANDARDS/PROCEDURE VALUES / DESCRIPTION
YES NO N/A OBS
Documentation Review
1 Have you verified the Records of previous CAT III and CAT IV inspection? YES
2 Have you checked for significant defects recorded in the drawing or the previous inspection? YES
3 Have you checked for any actions recommended in the previous report? YES
4 Have you checked the location and extent of the repairs given in the previous report? YES
5 Have you checked for NDT inspection performed and the results of the inspection? YES
6 Have you checked for the records if there is any Primary load-carrying components replaced or manufactured? YES
1 Have you identified the Identification number and OEM Identification on the equipment? YES
2 Have you identified the Size, Capacity & Model using COC or marking on the Equipment? YES
3 Have you identified the category of inspection to be carried out based on previous inspection? YES
4 Have you checked the Adequate dismantling to access all critical areas for CAT III as per OEM Manual? YES
5 Have you checked the Adequate dismantling to access all critical areas for CAT IV as per OEM Manual? YES
6 Have you checked for any Visual Cracks, loose fits or connections & elongation? YES
7 Have you checked for any Signs of wear, corrosion, over loading & evidence of unauthorized field welding? YES
8 Have you checked for any Potential dropped objects or damaged missing retention devices? YES
9 Have you checked for the Missing components, deterioration & Lubrication? YES
1 Have you verified the surface to confirm adequate paint and foreign material removal? YES
2 Have you taken the photo as evidence of proper surface preparation? YES
Dimensional inspection
1 Did you notify the customer when the equipment rejected? YES
2 Have you received the client acknowledgement particularly for the rejected equipment? YES
COMMENTS :
Manual tong rejected, Field welding found on the Jaw parts and Found parts from other OEMs (NOV & Rutong)
NEAR MISS OBSERVATION ,IF ANY:
CUSTOMER Advance Energy Systems REPORT NO. 5010051899-MT-002 DATE 01-Mar-2022 PAGE 1
DESCRIPTION OF ITEM BV-100 Manual Tong Assembly IDENTIFICATION NUMBER Asset No: 266045
MEASURED ACCEPT.LIMIT
PART / SECTION RESULT/ COMMENT
VALUE MIN/MAX
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PLAY BETWEEN LEVER & JAW (B) N/A MAX 1.12 mm N/A
Manufacturer: B+V(Forum) Size & Model : BV-100 Capacity: N/A INSPECTION RESULT/ COMMENTS
Photo of item section with ID No. Manual tong rejected, Field welding found on the Jaw parts and Found parts from
F.1461
Rev.0
05.06.2017
ALMANSOORI INSPECTION SERVICES
RIG EQUIPMENT INSPECTION CHECKLIST
EQUIPMENT NAME Manual Tong
COMPLIANCE TO THE
SR# INSPECTION CHECK POINTS STANDARDS/PROCEDURE VALUES / DESCRIPTION
YES NO N/A OBS
Documentation Review
1 Have you verified the Records of previous CAT III and CAT IV inspection? YES
2 Have you checked for significant defects recorded in the drawing or the previous inspection? YES
3 Have you checked for any actions recommended in the previous report? YES
4 Have you checked the location and extent of the repairs given in the previous report? YES
5 Have you checked for NDT inspection performed and the results of the inspection? YES
6 Have you checked for the records if there is any Primary load-carrying components replaced or manufactured? YES
1 Have you identified the Identification number and OEM Identification on the equipment? YES
2 Have you identified the Size, Capacity & Model using COC or marking on the Equipment? YES
3 Have you identified the category of inspection to be carried out based on previous inspection? YES
4 Have you checked the Adequate dismantling to access all critical areas for CAT III as per OEM Manual? YES
5 Have you checked the Adequate dismantling to access all critical areas for CAT IV as per OEM Manual? YES
6 Have you checked for any Visual Cracks, loose fits or connections & elongation? YES
7 Have you checked for any Signs of wear, corrosion, over loading & evidence of unauthorized field welding? YES
8 Have you checked for any Potential dropped objects or damaged missing retention devices? YES
9 Have you checked for the Missing components, deterioration & Lubrication? YES
1 Have you verified the surface to confirm adequate paint and foreign material removal? YES
2 Have you taken the photo as evidence of proper surface preparation? YES
Dimensional inspection
1 Did you notify the customer when the equipment rejected? YES
2 Have you received the client acknowledgement particularly for the rejected equipment? YES
COMMENTS :
Manual tong rejected, Field welding found on the Jaw parts and Found parts from other OEMs (NOV & Rutong)
NEAR MISS OBSERVATION ,IF ANY:
CUSTOMER Advance Energy Systems REPORT NO. 5010051899-MT-003 DATE 01-Mar-2022 PAGE 1
DESCRIPTION OF ITEM BV-100 Manual Tong Assembly IDENTIFICATION NUMBER Asset No: 282638
MEASURED ACCEPT.LIMIT
PART / SECTION RESULT/ COMMENT
VALUE MIN/MAX
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PLAY BETWEEN LEVER & JAW (B) N/A MAX 1.12 mm N/A
Manufacturer: B+V(Forum) Size & Model : BV-100 Capacity: N/A INSPECTION RESULT/ COMMENTS
Photo of item section with ID No. Manual tong rejected, Field welding found on the Jaw parts and Found parts from
F.1461
Rev.0
05.06.2017
ALMANSOORI INSPECTION SERVICES
RIG EQUIPMENT INSPECTION CHECKLIST
EQUIPMENT NAME Manual Tong
COMPLIANCE TO THE
SR# INSPECTION CHECK POINTS STANDARDS/PROCEDURE VALUES / DESCRIPTION
YES NO N/A OBS
Documentation Review
1 Have you verified the Records of previous CAT III and CAT IV inspection? YES
2 Have you checked for significant defects recorded in the drawing or the previous inspection? YES
3 Have you checked for any actions recommended in the previous report? YES
4 Have you checked the location and extent of the repairs given in the previous report? YES
5 Have you checked for NDT inspection performed and the results of the inspection? YES
6 Have you checked for the records if there is any Primary load-carrying components replaced or manufactured? YES
1 Have you identified the Identification number and OEM Identification on the equipment? YES
2 Have you identified the Size, Capacity & Model using COC or marking on the Equipment? YES
3 Have you identified the category of inspection to be carried out based on previous inspection? YES
4 Have you checked the Adequate dismantling to access all critical areas for CAT III as per OEM Manual? YES
5 Have you checked the Adequate dismantling to access all critical areas for CAT IV as per OEM Manual? YES
6 Have you checked for any Visual Cracks, loose fits or connections & elongation? YES
7 Have you checked for any Signs of wear, corrosion, over loading & evidence of unauthorized field welding? YES
8 Have you checked for any Potential dropped objects or damaged missing retention devices? YES
9 Have you checked for the Missing components, deterioration & Lubrication? YES
1 Have you verified the surface to confirm adequate paint and foreign material removal? YES
2 Have you taken the photo as evidence of proper surface preparation? YES
Dimensional inspection
1 Did you notify the customer when the equipment rejected? YES
2 Have you received the client acknowledgement particularly for the rejected equipment? YES
COMMENTS :
Manual tong rejected, Field welding found on the Jaw parts and Found parts from other OEMs (NOV)
NEAR MISS OBSERVATION ,IF ANY:
CUSTOMER Advance Energy Systems REPORT NO. 5010051899-MT-004 DATE 01-Mar-2022 PAGE 1
DESCRIPTION OF ITEM BV-100 Manual Tong Assembly IDENTIFICATION NUMBER Asset No: 167007
MEASURED ACCEPT.LIMIT
PART / SECTION RESULT/ COMMENT
VALUE MIN/MAX
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PLAY BETWEEN LEVER & JAW (B) N/A MAX 1.12 mm N/A
Manufacturer: B+V(Forum) Size & Model : BV-100 Capacity: N/A INSPECTION RESULT/ COMMENTS
F.1461
Rev.0
05.06.2017
ALMANSOORI INSPECTION SERVICES
RIG EQUIPMENT INSPECTION CHECKLIST
EQUIPMENT NAME Manual Tong
COMPLIANCE TO THE
SR# INSPECTION CHECK POINTS STANDARDS/PROCEDURE VALUES / DESCRIPTION
YES NO N/A OBS
Documentation Review
1 Have you verified the Records of previous CAT III and CAT IV inspection? YES
2 Have you checked for significant defects recorded in the drawing or the previous inspection? YES
3 Have you checked for any actions recommended in the previous report? YES
4 Have you checked the location and extent of the repairs given in the previous report? YES
5 Have you checked for NDT inspection performed and the results of the inspection? YES
6 Have you checked for the records if there is any Primary load-carrying components replaced or manufactured? YES
1 Have you identified the Identification number and OEM Identification on the equipment? YES
2 Have you identified the Size, Capacity & Model using COC or marking on the Equipment? YES
3 Have you identified the category of inspection to be carried out based on previous inspection? YES
4 Have you checked the Adequate dismantling to access all critical areas for CAT III as per OEM Manual? YES
5 Have you checked the Adequate dismantling to access all critical areas for CAT IV as per OEM Manual? YES
6 Have you checked for any Visual Cracks, loose fits or connections & elongation? YES
7 Have you checked for any Signs of wear, corrosion, over loading & evidence of unauthorized field welding? YES
8 Have you checked for any Potential dropped objects or damaged missing retention devices? YES
9 Have you checked for the Missing components, deterioration & Lubrication? YES
1 Have you verified the surface to confirm adequate paint and foreign material removal? YES
2 Have you taken the photo as evidence of proper surface preparation? YES
Dimensional inspection
1 Did you notify the customer when the equipment rejected? YES
2 Have you received the client acknowledgement particularly for the rejected equipment? YES
COMMENTS :