Soyal AR716EV2/Ei hardware operation manual


Revision: V1

Date released: 1 Nov 2006

UM_SoyalAR716EV1
Table of Contents
1. Introduction ---------------------------------------------------------------------------------- 2

2. Installation ----------------------------------------------------------------------------------- 3

3. Software Setting --------------------------------------------------------------------------- 4

3.1 701 Server software setting of external weigand reader -------------- 4

3.2 Door number setting of 701E Parameter --------------------------------- 4

3.3 DI Input V.S. Relay Output Connection Setting of 701E Parameter---- 5

3.4 Weigand reader LED and Buzzer indicators ---------------------------- 5

4. AR-716E-IO Software Setting --------------------------------------------------------- 6

4.1 Set relay time ------------------------------------------------------------------- 6

4.2 AR-716E-IO hardware installation ------------------------------------ 6

4.3 Push Button & Lock installation --------------------------------------------- 7

5. AR-727i Configuration ------------------------------------------------------------- 8

5.1 Reset to Factory Default of the AR-727i --------------------------------- 8

5.2 DIP Switch Settings ----------------------------------------------------------- 8

5.3 AR-727i’s contains three LED indicators,

as described in the following table ------------------------------------ 8

5.4 How to set IP address on the AR-716Ei --------------------------------- 9

5.4.1 Get IP address by using Net727i software --------------------------------- 9

5.4.2 Get IP address by DHCP Server --------------------------------- 13

5.4.3 Get IP address by AR-801CM (COM Port) connects to PC ------------16

6. Installation diagram--------------------------------------------------------------------------- 19

6.1 AR-716Ei and AR-721H networking installation ------------------------19

6.2 AR-716EV2 and AR-721H networking installation ------------------------20

6.3 Points for attation------------------------------------------------------------------- 21

1
1. Introduction

 Card capacity is 15,000 Users.

 11,000-Event history transaction.

 Built-in watchdog to prevent the system from halting.

 Support scheduled door release time zone.

 Support scheduled arming time zone.

 Built-in power and RS-485 transmission LED indicator for signal state.

 It is a 16-doors networking controller and can be linked up to 254 units.

 Support alarm status output when reader off-line.

 Multi-door Anti-pass-back and support auto reset function for violating


Anti-pass-back.

 Support opens all doors function in an emergency.

 Two RS–485 Reader ports, each port supports 8 readers.

 Two Wiegand ports for External readers.

 Data retain over 60 days when power failure.

 Everyone can assign different time zone for each door.

 Support 4 sets “Force ON/OFF code” for remote control from RS-485 channel
readers.

 Built-in 10 BaseT interface for Ethernet networking. (AR-716Ei)

2
2. Installation

1. Select a location for the AR-716Ei unit that is secure and sheltered from weather and
extreme humidity. Choose a location that facilitates access to power and is
reasonably close to the doors that are to be controlled.
2. Using the unit as a template, mark on the mounting surface the location of the two
mounting holes.
3. Install appropriate mounting hardware (anchors, retainers, etc.) to the mounting
surface if necessary.
4. Screw mounting screws into the top 2 mounting holes of the mounting surface,
leaving about 0.4 cm clearance. Place panel top key-way mounting holes over
installed mounting screws and slide panel down.
5. Route cables into the enclosure through knockouts in sides, top or bottom of box,
being careful not to nick or scrape insulation on any rough edges.

CAUTION SHOULD BE TAKEN NOT TO TOUCH CIRCUIT BOARD OR


ELECTRONIC COMPONENTS PRIOR TO AND DURING INSTALLATION TO AVOID
ELECTRO-STATIC DISCHARGE (ESD) DAMAGE.

Wall Surface

Use Appropriate Fasteners

3
3. Software Setting

3.1 701 Server software setting of external weigand reader


How to enter?
Step1: Click the 701 Server Icon twice to access the Server on the down right corner
of the windows.

Step2: Click Tool Bar Icon (701E parameter) for the windows.

Step3: Enter networking controller node ID, then click “Read”.


Step4: Click the page of Door Number.

Power Must higher than 13.8VDC


CN2
Ethernet
Power

Reset
DC15V
Vin CN1 Channel 2 RX
Battery Vin
BV+
~~

Channel 2 TX
BV-
AR-727i JP5
Node: 009 Channel 1 RX
To CH2 CN3 2
Node: 016
AR-721H4 1 Channel 1 TX
AR-721H4
Node: 001 CH1
To Host RX
Node: 008 JP1 JP2
~~

HOST Battery
Host TX 3
1
~~

K1 3
1 2 3 4 5 6 7 8
1 4 16 64
CN4 K2 RELAY RELAY
ON
AR-801CM K3 K1 K2
K4 Node 1 2 3 4 5 6 7 8
ON

~~
Next
COM
To PC
2 8 32 128
Controller
COM RELAY RELAY Busy ON
DI.4 K3 K4 AR-716Ei 001 1
DI.3
D12 JP3
DI.2 JP4 ON
DI.1 D11
D10 002 2
V12 D9
DC12V CN5 PORT1 PORT2
ON
1 2 003 1+2
CN4
~

JP5 ON
Brown / Brown LED

Brown / Brown LED


Black / Black GND

Black / Black GND

K1 3 2-3 On:Clear
Green / Green D0

Green / Green D0

033 1+32
Red / Red 12V

Red / Red 12V


Purple / Gray BZ

Pink / Gray BZ
Blue / Blue D1

Blue / Blue D1

2 Reset to default value


K2 1 (Must Power OFF)
K3 Node:
JP5
K4 3 1-2 On:RUN
2
COM 1
Normal mode
AR-721U
or AR-721K

3.2 Door number setting of 701E Parameter


1. Reader 1-8 is the door number of the CH1 RS-485 readers.
(The CH1 can connect to on-line reader ID node 1-8).
2. Reader 9-16 is the door number of the CH2 RS-485 readers.
(The CH2 can connect to on-line reader ID node 9-16).
3. ID Node of WG reader port 1 is fixed to no.17 on the 716EV2/Ei PCB.
If enable anti-pass-back, ID Node 17 is fixed to be in door.
4. ID Node of WG reader port 2 is fixed to no.18 on the 716EV2/Ei PCB.
If enable anti-pass-back, ID Node 18 is fixed to be out door.
Note: The above Door number can be both changeable.

4
Step5: Click the page of DI Input V.S. Relay Output Connection.

CN4

K1
K2
CN4
K3 K1
K4 K2 RELAY RELAY
K3 K1 K2
COM K4
COM

COM RELAY RELAY


DI.4 K3 K4
DI.3
D12
DI.2 JP4
DI.1 D11
V12 D10
D9
CN5

3.3 DI Input V.S. Relay Output Connection setting of 701E Parameter


1. The DI.1 is exit button input of WG port 1 and the K1 is open door relay.
(1) Choose “DI 1” under the menu item.
(2) Click “K1”.
2. The DI.2 is exit button input of WG port 2 and the K2 is open door relay.
(1) Choose “DI 2” under the menu item.
(2) Click “K2”.
Note: Active second can be set only when the window is DI 1.
If DI1 is used for exit button input of WG port 1, DI1 to Active Release All Doors
function will be disable.
3.4 Weigand reader LED and Buzzer indicators
1. LED light green and one beep sound mean acknowledge, LED light green twice and
two beep sounds mean not acknowledge.
2. In anti-pass-back access mode, LED light green five times and five beep
sounds mean violates access function.
3. When access modes have entering user code, after flash card, LED light green four
times and four beep sounds mean that reader wait for being entered the 4-digit user
code.

5
4. AR-716E-IO Software Setting (Optional)
4.1 Set relay time

Step1: Click the page of Reader Relay V.S. 701E Relays


Step2: Enter relay time in the blank column. Range from 0 to 60,000. (Default 7 sec.)
Step3: Press [ Write ].

4.2 AR-716E-IO hardware installation

Step1: Take away each screw on the top left and on the down left of AR-716EV2 \ 716Ei
PCB board.
Step2: Screw copper column to fix AR-716E-IO PCB board.
Step3: Then, screw tightly copper column by using screw before take away.
Step4: Connect plug DB1 of AR-716E-IO to socket DB1 of AR-716EV2 \ 716Ei PCB
board.
Connect plug DB2 of AR-716E-IO to socket DB2 of AR-716EV2 \ 716Ei PCB
board.

6
4.3 Push Button & Lock installation

IO-EXPEND
CN 1 K1 K2

COM 1 2
NO NO
COM RELAY RELAY
K 1 NC
K 1 NC
K 2
NO NO
K 2 RELAY RELAY
K 3 K 3 K 4

3 4 COM 5 6
NC NC
K 4 K3 K4
CN 2 NO
K5 K6
NO
COM RELAY RELAY
K 5 NC
K 5 NC
K 6
K 6 NO
RELAY
NO
RELAY
K 7

7 8
K 7 K 8
K 8 NC
K7
NC
K8

CN 3

V+ GND 8 7 6
DB2

Node 12
Node 11
Node 10
Node 9

5 4 3 2 1 CN 4
Node 4
Node 3
Node 2
Node 1
DB1

Push Button Door Exit


ECL-ACC1010

CN1

COM

K1
Lock (-GND)
-GND

K2

K3
+12VDC

Power Supply
Magnetic Lock K4
+12VDC 2A Lock (+12VDC)
CN2

COM

K5
-GND

Lock (-GND)

K6

K7
+12VDC

Power Supply Magnetic Lock K8


+12VDC 2A Lock (+12VDC)

7
5. AR-727i Configuration

5.1 Reset to Factory Default of the AR-727i

Press RESET button more than 5 seconds,


then AR-727i will restore to Factory Default value.
IP Address : 192.168.001.127
Gateway IP : 192.168.001.254
Subnet Mask : 255.255.255.000
Serail Port : 9600,N,8,1
TCP Port : 1621
Password : none

5.2 DIP Switch Settings

Description
Switch 1 DHCP Function
AR-727i support Auto Configuration of the IP and
gateway addresses and subnet mask function, but
must make sure the DHCP Server is active.
Switch 2 Serial Setup Mode

5.3 AR-727i’s contains three LED indicators, as described in the following table

LED Name LED Color LED Function


Link Yellow Media is connected.
Off Media is not connected.
ACT Green 10 Mbps Ethernet connection.
Off Ethernet cable is disconnected,
or has a short.
ACT
BUSY Red Configuration Setup.
BUSY
AR-727i Off No.
LINK

8
5.4 How to set IP address on the AR-716Ei
5.4.1 Get IP address by using Net727i software
Usually, the network of some company don’t built-in the DHCP Server. Therefore, we
can use the following method to get default IP address and modify it. The steps as
follows:
Step 1: Press RESET button more than 5 seconds, The BUSY LED will flash 5 times,
then AR-727i will restore to Factory Default value.
Step 2: Open explorer, click “My Network Places” and press right key to open operties.

Step 3: Click “Local Area Connection” and press right key to open Properties.
Then double click Internet Protocol (TCP/IP) to open Properties.

9
Step 4: Click ”Use the following IP address” and enter IP address 192.168.001.64,
Subnet mask 255.255.255.0

Step 5: Click “ok” to exit.


Step 6: Install Net727i.exe into your PC and run Net727i.exe
(Start → Programs → soyal software → Net727i )

10
Step 7: Click “Get” to get default Local IP Address, Gateway, Netmask and TCP Port.
Step 8: Change new address and parameters then click “write”.
Step 9: switch DIP SW-1 and SW-2 to “OFF” position.

Remark:
(1) How to know PC’s IP Address? (Win98)
Start → execute → enter “winipcfg”.

(2) How to know PC’s IP Address? (Win2000)


Start → Programs → Accessories → Command Prompt → C:\> ipconfig

(3) Please see detailed parameter in next page:

11
Setting Value Notes Necessity
Local IP Address 192.168.001.127 Defines own IP Address of the Required
AR-727CM
Local Gateway IP 192.168.001.254 Defines the IP Address of the Required
Address default gateway
Local Subnet Mask 255.255.255.000 Defines the IP Address range for Required
the local network segment
TCP Port 1621 The TCP port that other devices Required
must use to contact this device. To
avoid conflicts with standard TCP
ports.
MAC Address 00.E0.4C.00.00.50 The MAC (Media Access Control) -
address is a unique identifier set
at the factory.
Force Transmit time 5 Forces AR-727CM device’s Optional
TCP/IP protocol software to try to
pack serial data received during
the specified time into the same
data frame.
Force Transmit 32 Defines the amount of data in the Optional
Bytes serial, Ethernet buffer at which the
break condition will be generated
and the contents of buffer will be
sent out via the Ethernet port.
Lock Remote IP - Allows contact with only the Optional
Address specified remote IP address.
Lock Serial Port - To avoid the hacker use this IP to Optional
(Free Run or intercept data when Remote IP
Freeze Over) Address doesn’t receive data.
Setup Password none Console password Optional
Serial Port Speed 9600 Changes current baud rate of the Required
AR-727CM’s serial port (from
2400bps to 57600bps).
TCP Auto 60 This device automatically closes Optional
Disconnect Time TCP connection if there is no TCP
(Second) activity for the given time.
Serial Port - An exchange of signal over Optional
Hardware specific wires which each device
Handshaking indicates its readiness to send or
(RTS/CTS) receive data.
DHCP - Selecting the enable option allows Optional
DHCP to automatically assign the
AR-727CM’s IP address.

12
5.5.2 Get IP address by DHCP Server:
AR-727i support Auto Configuration of the IP and gateway addresses and subnet
mask function, but must make sure the DHCP Server is active. The steps as follows:
Step 1: Power off.
Step 2: PCB diagram as follows by using DHCP Function.

Switch DIP SW-1 to “ON” position.


Switch DIP SW-2 to “OFF” position.
Switch Jumper j2,J3, J4 and J5 to Net position.
No IC Chip in the U3 position.
Step 3: Power on. In begging state the ACT LED will flashing, after IP has got ACT
LED will off and auto save the new IP address to EEPROM.
Step 4: Power off.
Step 5: Change communication IC Chip from the “U2” position to the “U3” position.
Step 6: Then, Switch DIP SW-1 to “OFF” position and Switch DIP SW-2 to “ON”
position. ( return to Serial Setup Mode)
Step 7: Connect AR-801CM to the HOST of the PCB.
Step 8: Power on.
Step 9: To modify parameter on the AR-727i through the Hyper-Terminal function of
the Window.
(Start → Programs → Accessories → Communication → Hyper Terminal)

13
Step 10: Click “Hyper-Terminal”. Step 11: key-in any temporary name.
Shown as follows: It is not important matter.

Step 12: Choose which COM port that


AR-701CM connect and click OK to exit.
Step 13: Set Port Settings to 9600, 8,None, 1, and click “OK” to save.

14
Step 14: AR-727i already gets IP address now shown as follows:
Note that save it after set all parameters.

Step 15: Power off. Then switch DIP SW-2 to “OFF” position, take away communication
IC Chip
on the U3 position of the PCB and AR-801CM.

15
5.5.3 Get IP address by AR-801CM (COM Port) connects to PC
At first, PCB diagram as follows and Connect AR-801CM to the HOST of the PCB:

Switch DIP SW-1 to “OFF” position.


Switch DIP SW-2 to “ON” position. (Serial Setup Mode)
Switch Jumper J3, J4 and J5 to RS-485 position.
Make sure that have communication IC Chip in the U3 position.

16
Step 1: To modify parameter on the AR-727i through the Hyper-Terminal function of the
Window.
(Start → Programs → Accessories → Communication → Hyper Terminal)

Step 2: Click “Hyper-Terminal”. Step 3: key-in any temporary name.


Shown as follows: It is not important matter.

Step 4: Choose which COM port that Step 5: Set Port Settings to 9600, 8, None, 1,
AR-801CM connect and click OK to exit. None and click “OK” to save.

17
Step 6: AR-727i already gets IP address now shown as follows:

Step 7: Please refer above item and enter item on the so that set all
parameters.
Step 8: Note that enter item 6 on the to save parameter after finishing to set
parameter.
Step 9: Then switch DIP SW-1 and SW-2 to “OFF” position.

18
6.1 AR-716Ei and AR-721H networking installation

6. Installation diagram
Power Must higher than 13.8VDC
CN2
Ethernet
Power

Reset
DC15V
Vin CN1 Channel 2 RX
Battery Vin
BV+
~~

Channel 2 TX
BV-
AR-727i JP5
Node: 009 Channel 1 RX
To CH2 CN3 2
Node: 016
AR-721H4 1 Channel 1 TX
AR-721H4
Node: 001 CH1
To Host RX
Node: 008 JP1 JP2
~~

HOST Battery
Host TX 3
1
~~

K1 3

1 2 3 4 5 6 7 8
1 4 16 64
CN4 K2 RELAY RELAY
ON
AR-801CM K3 K1 K2
K4 Node 1 2 3 4 5 6 7 8

ON
~~
19

COM
To PC Next 2 8 32 128
Controller
COM RELAY RELAY Busy ON
DI.4 K3 K4 AR-716Ei 001 1
DI.3 JP3
D12
DI.2 JP4 ON
DI.1 D11
D10 002 2
V12 D9
DC12V CN5 PORT1 PORT2
ON
1 2 003 1+2
CN4

~
JP5 ON

Brown / Brown LED

Brown / Brown LED


Black / Black GND

Black / Black GND


K1 3 2-3 On:Clear

Green / Green D0

Green / Green D0
033 1+32
Red / Red 12V

Red / Red 12V

Pink / Gray BZ
Purple / Gray BZ
Blue / Blue D1

Blue / Blue D1
2 Reset to default value
K2 1 (Must Power OFF)
K3 Node:
JP5
K4 3 1-2 On:RUN
2
COM 1
Normal mode
AR-721U
or AR-721K
6.2 AR-716EV2 and AR-721H networking installation
Power Must higher than 13.8VDC
CN2
Ethernet
Power

Reset
DC15V
Vin CN1 Channel 2 RX
Battery Vin
BV+

~~
Channel 2 TX
BV-
727i JP5
Node: 009 Channel 1 RX
To CH2 CN3 2
Node: 016
AR-721H4 1 Channel 1 TX
AR-721H4
Node: 001 CH1
To Host RX
Node: 008 JP1 JP2
~~

HOST Battery
Host TX 3
1
~~
K1 3

1 2 3 4 5 6 7 8
1 4 16 64
CN4 K2 RELAY RELAY
ON
AR-801CM K3 K1 K2
K4 Node
20

1 2 3 4 5 6 7 8

ON
~~ COM
To PC Next 2 8 32 128
Controller
COM RELAY RELAY Busy ON
DI.4 K3 K4 AR-716EV2 001 1
DI.3 JP3
D12
DI.2 JP4 ON
DI.1 D11
D10 002 2
V12 D9
DC12V CN5 PORT1 PORT2
ON
1 2 003 1+2
CN4

~
JP5 ON

Brown / Brown LED

Brown / Brown LED


Black / Black GND

Black / Black GND


K1 3 2-3 On:Clear

Green / Green D0

Green / Green D0
033 1+32

Red / Red 12V

Red / Red 12V

Pink / Gray BZ
Purple / Gray BZ
Blue / Blue D1

Blue / Blue D1
2 Reset to default value
K2 1 (Must Power OFF)
K3 Node:
JP5
K4 3 1-2 On:RUN
2
COM 1
Normal mode
AR-721U
or AR-721K

Note that the connecting distance between AR-801CM and the PC cannot be more than 2 meter.
6.3 Points for attention
1. Please use the following installation method, it is correct.

801CM
OR
Controller

Controller
OR
Reader
2. Don’t use the following installation method, it will cause communication error.

801CM
OR
Controller

Controller
OR
Reader

3. We suggest using the following cable in RS-485 communication

Please screw snake


net on the controller.

21
Specification

User Capacity 15,000


Event Log 11,000
Power Requirement 15-24VDC
Power Consumption < 2.5W
Communication Interface Reader Channel:RS485*2
Host Channel:RS485 / Ethernet
Baud Rate RS-485 9600 bps (N, 8, 1)
Ethernet 10M
Environment -20 to +75
DI Input 4+8 (AR-716E-IO)
Relay Output 4+8 (AR-716E-IO)
Max. RS-485 Reader Supported 16
Max. WG Reader Supported 2
Anti-pass Back Yes
Door Group 255
Time Zone 63
Editing Mode PC Software
Dimension (mm) 180(H)*231(W)*62(D)
Weight (g) 1,840 ± 50
Housing Material Metal
Others UPS Function
(No battery included)