Rociador TY3131
Rociador TY3131
Rociador TY3131
00-381-9312 | +1-401-781-8220
www.tyco-fire.com
5
7/16"
(11,1 mm) 2-1/4"
4
NOMINAL (57,2 mm)
2 MAKE-IN
3 2-3/16" 1-9/16"
(55,6 mm) WRENCH (39,7 mm)
1 FLATS
7
1/2" NPT SSP DEFLECTOR * 2-7/8" (73,0 mm) DIA.
CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT
FIGURE 1
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS
2.8 K-FACTOR, 1/2 INCH NPT
5 7/16"
(11,1 mm) 2-3/16"
4 NOMINAL (55,6 mm)
MAKE-IN
2 1-1/2"
2-3/16"
(55,6 mm) WRENCH (38,1 mm)
3 FLATS
1
1/2" NPT SSP DEFLECTOR * 2-7/8" (73,0 mm) DIA.
CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT
FIGURE 2
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS
4.2 K-FACTOR, 1/2 INCH NPT
TFP171
Page 3 of 10
5 7/16"
(11,1 mm) 2-3/16"
4 NOMINAL (55,6 mm)
MAKE-IN
2 1-1/2"
2-3/16"
(55,6 mm) WRENCH (38,1 mm)
3 FLATS
1
1/2" NPT SSP DEFLECTOR * 2-7/8" (73,0 mm) DIA.
CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT
FIGURE 3
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS
5.6 K-FACTOR, 1/2 INCH NPT
6*
5 1/2"
(12,7 mm) 2-5/16"
4 NOMINAL (58,7 mm)
MAKE-IN
2
2-1/4" 1-9/16"
(57,2 mm) (39,7 mm)
3
1
3/4" NPT SSP DEFLECTOR * 2-7/8" (73,0 mm) DIA.
CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT
FIGURE 4
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS
8.0 K-FACTOR, 3/4 INCH NPT
TFP171
Page 4 of 10
5 7/16"
(11,1 mm) 2-1/4"
4 NOMINAL (57,2 mm)
MAKE-IN
2 1-9/16"
2-3/16"
(55,6 mm) WRENCH (39,7 mm)
3 FLATS
1
SSP *
1/2" NPT DEFLECTOR
CROSS
SECTION UPRIGHT PENDENT
FIGURE 5
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS
8.0 K-FACTOR, 1/2 INCH NPT
TABLE A
LABORATORY LISTINGS AND APPROVALS FOR
2.8 AND 4.2 K-FACTOR SPRINKLERS
TFP171
Page 6 of 10
TABLE B
LABORATORY LISTINGS AND APPROVALS FOR
5.6 AND 8.0 K-FACTOR SPRINKLERS
TFP171
Page 7 of 10
SPRINKLER FINISH
K NATURAL CHROME WHITE LEAD
TYPE
FACTOR BRASS PLATED POLYESTER COATED
PENDENT (TY1231)
and
2.8 UPRIGHT (TY1131)
75 PSI (12,1 BAR) N/A
1/2” NPT
RECESSED
PENDENT (TY1231)
PENDENT (TY2231)
and
4.2 UPRIGHT (TY2131)
175 PSI (12,1 BAR) N/A
1/2” NPT
RECESSED
PENDENT (TY2231)
PENDENT (TY4931)
8.0 175 PSI
and 175 PSI (12,1 BAR)
1/2” NPT (12,1 BAR)
UPRIGHT (TY4831)
NOTES:
1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the
Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York.
TABLE C
MAXIMUM WORKING PRESSURE
MOUNTING
MOUNTING SURFACE
SURFACE
FIGURE 6 FIGURE 7
SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON
2.8 K-FACTOR, 1/2 INCH NPT 2.8 K-FACTOR, 1/2 INCH NPT
MOUNTING
MOUNTING SURFACE
SURFACE
SERIES 1-1/4" (31,8 mm) SERIES 1-1/4" (31,8 mm)
CLOSURE CLOSURE
TY-FRB 3/4" (19,1 mm) TY-FRB 1" (25,4 mm)
FIGURE 8 FIGURE 9
SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON
4.2 K-FACTOR, 1/2 INCH NPT 4.2 K-FACTOR, 1/2 INCH NPT
Initial and frequent visual inspections of Responsibility lies with the owner for Care must be exercised to avoid dam-
random samples are recommended for the inspection, testing, and mainte- age to the sprinklers -before, during,
corrosion-resistant sprinklers to verify nance of their fire protection system and after installation. Sprinklers dam-
the integrity of the corrosion-resistant and devices in compliance with this aged by dropping, striking, wrench
material of construction. Thereafter, document, as well as with the appli- twist/slippage, or the like, must be
annual inspections per NFPA 25 should cable standards of the National Fire replaced. Also, replace any sprinkler
suffice. Protection Association (for example, that has a cracked bulb or that has lost
NFPA 25), in addition to the standards liquid from its bulb. (Ref. Installation
Inspections of corrosion-resistant
of any other authorities having jurisdic- Section).
sprinklers are recommended at close
range, instead of from the floor level tion. Contact the installing contractor or Initial and frequent visual inspections of
per NFPA. Inspection at close range sprinkler manufacturer regarding any random samples are recommended for
can better determine the exact sprin- questions. corrosion-resistant sprinklers to verify
kler condition and the long-term integ- Automatic sprinkler systems are rec- the integrity of the corrosion-resistant
rity of the corrosion-resistant material, ommended to be inspected, tested, material of construction. Thereafter,
which can be affected by the corrosive and maintained by a qualified Inspec- annual inspections per NFPA 25 should
conditions present. tion Service in accordance with local suffice.
requirements and/or national codes.
TFP171
Page 9 of 10
MOUNTING
MOUNTING SURFACE
SURFACE
SERIES 1-1/4" (31,8 mm) SERIES 1-1/4" (31,8 mm)
CLOSURE CLOSURE
TY-FRB 3/4" (19,1 mm) TY-FRB 1" (25,4 mm)
FIGURE 10 FIGURE 11
SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON
5.6 K-FACTOR, 1/2 INCH NPT 5.6 K-FACTOR, 1/2 INCH NPT
MOUNTING
MOUNTING SURFACE
SURFACE
CLOSURE SERIES 1-5/16" (33,3 mm) CLOSURE SERIES 1-5/16" (33,3 mm)
TY-FRB 13/16" (20,6 mm) TY-FRB 1-1/16" (27,0 mm)
FIGURE 12 FIGURE 13
SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON
8.0 K-FACTOR, 3/4 INCH NPT 8.0 K-FACTOR, 3/4 INCH NPT
Inspections of corrosion-resistant
sprinklers are recommended at close WRENCH
range, instead of from the floor level RECESS
per NFPA. Inspection at close range WRENCH RECESS
can better determine the exact sprin- (END "A" USED FOR
kler condition and the long-term integ- 1/2" NPT MODELS)
rity of the corrosion-resistant material,
which can be affected by the corrosive
conditions present.
WRENCH RECESS
(END "B" USED FOR
3/4" NPT MODELS) PUSH WRENCH IN TO
ENSURE ENGAGEMENT WITH
SPRINKLER WRENCHING AREA
FIGURE 14
W-TYPE 6 SPRINKLER FIGURE 15
WRENCH W-TYPE 7 RECESSED
SPRINKLER WRENCH
TFP171
Page 10 of 10
TEMPERATURE
MODEL/SIN SPRINKLER
RATINGS
FINISH
TABLE D
PART NUMBER SELECTION
SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS
Copyright © 2007-2010 Tyco Fire Suppression & Building Products. All rights reserved.