Techtrol Level Controller
Techtrol Level Controller
Techtrol Level Controller
Private Limited
It is available in three types TLC-F or TLC-M or TLC-N. The controller TLC-F is used with the
float switches and TLC-M with magnetic switches of Magnetic Level Gauges, having reed type
switching contacts. It amplifies the power ratings of reed switches to 5A @250 VAC through its
relay output. The controller TLC-N is used alongwith the probe in conductivity switch.
7272 68 68
N N
TLC-TLC-
LEVEL
LEVEL CONTROLLER
CONTROLLER L N EL CN 1E 2C 3 1 4 2 3 4
To probeTo probe
Supply Supply
7272 68 68
SUPPLY
SUPPLY R1 R1
R2 R2
R3 R3
R4 R4
RL1 RL1
RL2 RL2
RL3 RL3
RL4 RL4
NO
NO P NC P PNCNC
NO NONO
P PNC
NCNO
NOP PNCNC
NO P NC
www.punetechtrol.com
www.punetechtrol.com
FRONT
FRONT VIEW
VIEW REAR
REARVIEW
VIEW (CUTOUT)
(CUTOUT)
Panel Mounted Front view Rear view (Cutout)
CC 164
132
TLC- F
LEVEL CONTROLLER
www.punetechtrol.com 25
147
Ø7x2 nos
Mtg. Hole
PG11 Gland
150 CC 135
150 CC 135
FLAMEPROOF ENCLOSURE
CC 135
150
FLAMEPROOF ENCLOSURE
CC 135
150
215
215
Ø9.5 X 4 NOS
Ø9.5 X 4 NOS
Mtg holes
1/2" NPT Mtg holes
1/2" NPT
DC Gland
DC Gland
FRONT VIEW REAR VIEW
Wall Mounted (Ex-proof) Front viewVIEW
FRONT Rear view
REAR VIEW
Relay Outputs 2 x SPDT or 4 x SPDT or 2 x DPDT (Potential free relay contacts rated for 5A, 250 VAC )
4 x DPDT with two controller units
Relay Latching Field settable through DIP switch between L1 & L2 ; L3 & L4
Fail Safe Operation NA FSH or FSL through DIP switch setting
LED Indications Green‐ Supply, Red– Alarm (Relay On status)
Delay Time 2 sec
Power Consumption < 3 VA (90 - 270 VAC), 8 VA (24 VDC) < 10 VA
Terminals Suitable for 1.5 mm2 conductor size
Ambient Temperature 0 to 55 0 C
Humidity 90 % Rh (Non condensing)
Note : Control Panels with Customized Logic for Pump Automation with Auto/ Manual Facility and Hooter with Reset
Function are available on demand.
TERMINATION
Potential Free Relay O/P Contacts
L N E C 1 2 3 4 NO P NC NO P NC NO P NC NO P NC
Supply Lamp
To switch or Hooter
Conductivity Probe
L
Contactor (Motor)
TLC -
1. Product Series
FGS/MFGS/MFPS F
MLG M
CNS N
2. Enclosure x Cable Entry
ABS Panel Mtd. IP41 P
Cast Al. Exd Gr. IIB, Wall Mtd. x 1/2" NPT DC Cable Gland E
Others O
3. Power Supply
90 to 270 VAC 1
24 VDC 2
4. No. of Set Point x Relay Output
Two x SPDT 2
Four x SPDT 4
Two x DPDT 6
Four x DPDT (with 2 controller unit) 8
Other O
5. Relay Latching
No N
Yes Y
Regd. & Sales: S-18, MIDC Bhosari, Pune - 411026, India Works: J-52/7, MIDC Bhosari, Pune - 411026, India
+91-20-66342900 | ho@punetechtrol.com +91-20-67313600 | www.punetechtrol.com