Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

RSCF Method Statement Terrace Waterproofing

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

PAVAMANA NILAYA

No.1, 1 Cross, Shiridi Sai Nagar


st

K Narayanprua, Dr SRK Nagar (PO)


Bangalore – 560 077, Karnataka
Ph:080 8884118200/9980037411
E-Mail: prudential.sol@gmail.com
Website: www.prudentialsol.com

TERRACE WATERPROOFING WITH BRICK BAT COBA

Materials

1. Dr. Fixit Pidicrete URP: SBR latex for waterproofing,


2. Dr. Fixit Pidicrete AM: Expansive plasticizing admixture
3. Dr. Fixit Pidiproof LW+: Integral Waterproofing Compound.
4. Cement, sand and aggregates etc.…

Tools and Machineries


1. Grouting pump
2. Drilling machine
3. Chisel and hammer.
4. Wire brush, cleaning brush, Nylon brushes, gloves, bucket, metal rods, PVC nipples etc.

Surface preparation (Civil Contractor’s Scope)


1. Initial cleaning the surface
2. The area water proofing should be protected with proper barricades.
3. The entire area shall be taken up for thorough surface preparation and mechanical removal of
debris, laitance, protrusions, etc.
4. Honey combs and surface undulation shall be rectified as per standard procedure.
5. All concrete surface to be completely cured and surface to be given to receive waterproofing
system as per Consultant’s approval.

Method of Application
1. Cleaning the surface with coir/wire brush to remove the residue.
2. Any pipes or openings/protrusions shall be provided prior to taking up the surface preparation.

All bore packing:


a. Pipes to be placed/inserted in the core cut areas, shall be aligned properly prior to bore
packing.
b. Cleaning/Roughening the inside surface of the bore hole.
c. Pipes to be inserted in the core cut areas with effective leak-free shuttering system.
d. The pipe to be inserted, appropriately roughening with hacksaw-blade, applying a coat of Dr.
Fixit Pidicrete URP and over this, sprinkling sand to receive non-shrink grout.
e. Filling the gap between PVC pipe and core cut with Dr. Fixit Pidigrout 10M including
shuttering the gap bottom with backer rod or with suitable material.

Prudential Constructive Solutions Page 1


3. Construction joints shall be chased into ‘V’ groove and filled with polymer modified cementious
mortar 1:4 (1 litres Dr.Fixit SBR Latex/URP per 50kg cement bag)
4. Laying of angle fillets (50mm x 50mm) with necessary initial slurry bond coat at the junction of
slab & vertical walls prepared with cement sand mortar 1:4 admixed with Dr. Fixit Pidiproof
LW+ @ 200 ml per 50 kg bag of cement.
5. Pond/Flood test shall be conducted for 24 hours for a depth of 50mm.
6. Leaking points found if any, to be pressure grouted after fixing the PVC nipples and 40PSI grout
pump using cement slurry mixed with non-shrink admixture Dr. Fixit Pidicrete AM @225gms
per bag of cement.
7. Pre-wet the surface.
8. Applying a coat of acrylic cementitious slurry Dr. Fixit Pidicrete URP ratio of 1:1.5
(URP:Cement in 1:1.5 ratio) Coverage 2 Sqm.
9. Above the coating for horizontal surface providing and laying brickbat coba in slope with
minimum thickness of 55mm (min. 40mm at lower end and 70mm at higher end) including
filling the gaps and 15mm thick top finish admixed with Dr. Fixit Pidiproof LW+ integral
waterproofing compound as per manufacturer's recommendation.
10. Laying of angle fillets (50mm x 50mm) with necessary initial slurry bond coat at the junction of
brickbat coba & parapet wall.

For Prudential Constructive Solutions

Authorised Signatory

Prudential Constructive Solutions Page 2