IP Rating Reference Chart: IP Number First Digit - SOLIDS Second Digit - LIQUIDS

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

IP Rating Reference Chart

IP Number First Digit - SOLIDS Second Digit - LIQUIDS


IP00 Not protected from solids. Not protected from liquids.

IP01 Not protected from solids. Protected from condensation.

Protected from water spray less than 15 degrees


IP02 Not protected from solids.
from vertical.
Protected from water spray less than 60 degrees
IP03 Not protected from solids.
from vertical.

IP04 Not protected from solids. Protected from water spray from any direction.

Protected from low pressure water jets from any


IP05 Not protected from solids.
direction.
Protected from high pressure water jets from any
IP06 Not protected from solids.
direction.
Protected from immersion between 15
IP07 Not protected from solids.
centimeters and 1 meter in depth.
Protected from long term immersion up to a
IP08 Not protected from solids.
specified pressure.
Protected from touch by hands greater
IP10 Not protected from liquids.
than 50 millimeters.
Protected from touch by hands greater
IP11 Protected from condensation.
than 50 millimeters.
Protected from touch by hands greater Protected from water spray less than 15 degrees
IP12
than 50 millimeters. from vertical.
Protected from touch by hands greater Protected from water spray less than 60 degrees
IP13
than 50 millimeters. from vertical.
Protected from touch by hands greater
IP14 Protected from water spray from any direction.
than 50 millimeters.
Protected from touch by hands greater Protected from low pressure water jets from any
IP15
than 50 millimeters. direction.
Protected from touch by hands greater Protected from high pressure water jets from any
IP16
than 50 millimeters. direction.
Protected from touch by hands greater Protected from immersion between 15
IP17
than 50 millimeters. centimeters and 1 meter in depth.
Protected from touch by hands greater Protected from long term immersion up to a
IP18
than 50 millimeters. specified pressure.
Protected from touch by fingers and
IP20 Not protected from liquids.
objects greater than 12 millimeters.
Protected from touch by fingers and
IP21 Protected from condensation.
objects greater than 12 millimeters.
Protected from touch by fingers and Protected from water spray less than 15 degrees
IP22
objects greater than 12 millimeters. from vertical.
Protected from touch by fingers and Protected from water spray less than 60 degrees
IP23
objects greater than 12 millimeters. from vertical.
Protected from touch by fingers and
IP24 Protected from water spray from any direction.
objects greater than 12 millimeters.
Protected from touch by fingers and Protected from low pressure water jets from any
IP25
objects greater than 12 millimeters. direction.
Protected from touch by fingers and Protected from high pressure water jets from any
IP26
objects greater than 12 millimeters. direction.
Protected from touch by fingers and Protected from immersion between 15
IP27
objects greater than 12 millimeters. centimeters and 1 meter in depth.
Protected from touch by fingers and Protected from long term immersion up to a
IP28
objects greater than 12 millimeters. specified pressure.
Protected from tools and wires greater
IP30 Not protected from liquids.
than 2.5 millimeters.
Protected from tools and wires greater
IP31 Protected from condensation.
than 2.5 millimeters.
Protected from tools and wires greater Protected from water spray less than 15 degrees
IP32
than 2.5 millimeters. from vertical.
Protected from tools and wires greater Protected from water spray less than 60 degrees
IP33
than 2.5 millimeters. from vertical.
Protected from tools and wires greater
IP34 Protected from water spray from any direction.
than 2.5 millimeters.
Protected from tools and wires greater Protected from low pressure water jets from any
IP35
than 2.5 millimeters. direction.
Protected from tools and wires greater Protected from high pressure water jets from any
IP36
than 2.5 millimeters. direction.
Protected from tools and wires greater Protected from immersion between 15
IP37
than 2.5 millimeters. centimeters and 1 meter in depth.
Protected from tools and wires greater Protected from long term immersion up to a
IP38
than 2.5 millimeters. specified pressure.
Protected from tools and small wires
IP40 Not protected from liquids.
greater than 1 millimeter.
Protected from tools and small wires
IP41 Protected from condensation.
greater than 1 millimeter.
Protected from tools and small wires Protected from water spray less than 15 degrees
IP42
greater than 1 millimeter. from vertical.
Protected from tools and small wires Protected from water spray less than 60 degrees
IP43
greater than 1 millimeter. from vertical.
Protected from tools and small wires
IP44 Protected from water spray from any direction.
greater than 1 millimeter.
Protected from tools and small wires Protected from low pressure water jets from any
IP45
greater than 1 millimeter. direction.
Protected from tools and small wires Protected from high pressure water jets from any
IP46
greater than 1 millimeter. direction.
Protected from tools and small wires Protected from immersion between 15
IP47
greater than 1 millimeter. centimeters and 1 meter in depth.
Protected from tools and small wires Protected from long term immersion up to a
IP48
greater than 1 millimeter. specified pressure.

IP50 Protected from limited dust ingress. Not protected from liquids.
IP51 Protected from limited dust ingress. Protected from condensation.

Protected from water spray less than 15 degrees


IP52 Protected from limited dust ingress.
from vertical.
Protected from water spray less than 60 degrees
IP53 Protected from limited dust ingress.
from vertical.

IP54 Protected from limited dust ingress. Protected from water spray from any direction.

Protected from low pressure water jets from any


IP55 Protected from limited dust ingress.
direction.
Protected from high pressure water jets from any
IP56 Protected from limited dust ingress.
direction.
Protected from immersion between 15
IP57 Protected from limited dust ingress.
centimeters and 1 meter in depth.
Protected from long term immersion up to a
IP58 Protected from limited dust ingress.
specified pressure.

IP60 Protected from total dust ingress. Not protected from liquids.

IP61 Protected from total dust ingress. Protected from condensation.

Protected from water spray less than 15 degrees


IP62 Protected from total dust ingress.
from vertical.
Protected from water spray less than 60 degrees
IP63 Protected from total dust ingress.
from vertical.

IP64 Protected from total dust ingress. Protected from water spray from any direction.

Protected from low pressure water jets from any


IP65 Protected from total dust ingress.
direction.
Protected from high pressure water jets from any
IP66 Protected from total dust ingress.
direction.
Protected from immersion between 15
IP67 Protected from total dust ingress.
centimeters and 1 meter in depth.
Protected from long term immersion up to a
IP68 Protected from total dust ingress.
specified pressure.

IP69K Protected from total dust ingress. Protected from steam-jet cleaning.