Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Aqms Pro

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

AQMS PRO

Air Quality monitoring system

REAL TIME AIR QUALITY SYSTEM


AQMS PRO
FITURE
Display 7”, touch screen
Comunication Internet 4G/EDGE/GPRS Wifi, LAN

Pengolahan data laporan harian, mingguan dan tahunan


Pengolahan data ISPU harian, mingguan dan tahunan
Menampilkan data di Indoor dan Outdoor display.
Laporan data per parameter kritis, Harian, mingguan dan tahunan
Dilengkapi dengan Casset Filter untuk menganalisa jenis debu lewat laboratorium.

PARTICULATE SENSOR
SPESIFIKASI
PM 10, PM 2.5 and TSP
Working principle : Laser Mie-Scattering Principle
Measurement range : 105.900 ug/m3
Working temperature Range : 0~50° C
Flowrate Measurement : 2.83 L/m
4 Channel particle size monitoring
SPESIFIKASI
SENSOR SULFUR DIOXIDE SO2
Operation Principle : 3-Electroda Electrochemical
Nominal Range : 0 – 1 ppm
Maximum Overload : 10 ppm
Resolution : < 0.01 ppm
Response Time : < 20 sec

SENSOR CARBON MONOXIDE (CO)


Operation Principle : 3-Electroda Electrochemical
Nominal Range : 0 – 300 ppm
Maximum Overload : 400 ppm
Resolution : 0.1 ppm
Response Time : < 45 sec

SENSOR NITROGEN DIOXIDE (NO2)


Operation Principle : 3-Electroda Electrochemical
Nominal Range : 0 – 1 ppm
Maximum Overload : 10 ppm
Resolution : < 0.05 ppm
Response Time : < 60 sec
AQMS PRO
Spesifikasi
Sensor Ozone (O3)
Operation Principle : 3-Electroda Electrochemical
Nominal Range : 0 – 5 ppm
Maximum Overload : 50 ppm
Resolution : < 0.02 ppm
Response Time : < 60 sec

Sensor Hydrocarbon (HC)


Operation Principle : Infrared
Nominal Range : 0-100% lel
Maximum Overload : -
Resolution : 1% of measuring range
Response Time : < 30 sec

Metrologi Sensor
Spesifikasi
Radiation WIND SPEED
Unit : W/m2 PRINCIPLE : ULTRASONIC
Accuracy : 5% MEASURING RANGE : 0 – 75 M/S
Respon time (95%) : < 1 Sec UNIT : M/S
Range : 1400 W/m2 ACCURACY : ± 0.3 M/S
RESULUTION : 0.1 M/S
Temperature
Principle : NTC
Measuring range : -500 – 600C
Unit : oC
Accuracy : ± 0.20C

Relative humidity
Principle : Capacitive
Measuring range : 0 – 100% RH
Unit : % RH
Accuracy : ± 2% RH

Air pressure
Principle : MEMS capacitive
Measuring range : 300 – 1200 hPa
Unit : hPa
Accuracy : ± 0.5 hPa
AQMS PRO
More Information

CONTACT US
Official Address Official Website
Ruko Suja Plaza, totalenviro.co.id
Jl. Raya Hankam No.08
Jatirahayu, Pondok Melati
Bekasi - 17414
E-mail Address
Call Center
sales02@totalenviro.co.id
+62 821 4486 1199