Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Kingspan Europanel Jumbo KS100 ERO Datasheet MEATCA en

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Insulated Panels

Middle East, Africa, Turkey


& Central Asia

Flat Roof Panel


KS100 ERO Europanel Jumbo
Product Data Sheet
Flat Roof Panel KS100 ERO Europanel Jumbo
Product Data Sheet

KS100 ERO Europanel Jumbo


Technical Data

KS100 ERO Europanel Jumbo is an insulated flat roof Application


system combining a structural deck, QuadCore™ insulation
and a metal top sheet into one product. Europanel Jumbo is suitable for flat roof applications with
minimum roof slope of 1% (0.5°).
Designed to support a choice of site applied standing seam
or membrane finishes, Europanel Jumbo provides a clear
span capability of up to 7 metres, and is faster to install than
alternative built-up roof deck systems. The internal face of
the deck is pre-finished with a clean white color, providing a
smooth clean interior appearance.

Standard Dimensions
& Joint Detail QuadCore™ t

40 40

275 mm 275 mm 275 mm


825 mm cover width

Special fixing washer Special fixing washer


Membrane Membrane

Profiled Intermediate
sealing filler support

200 mm

Dimensions, Weight and Thermal Features and Benefits


Performance  Up to 7 metre spanning capability.
 Rapid, single component, single-fix installation.
t - Core Thickness (mm) 100
 Available as complete watertight solution with PVC
D - Overall Dimension (mm) 200 membrane.
U-value (W/m2K) 0,17
 Requires no / limited secondary steelwork.
R-value (m2K/ W) 5,88
 Lengths available up to 12 metres (subject to transport
R-value (hr.ft2.°F/BTU) 33 limitations).
External: 0,7 mm Steel  Provides a clean internal pre-finished interior surface.
Weight (kg/m2) 19,00
Internal: 0,9 mm Steel
 Can contribute significantly to the airtightness of the roof
U-value have been calculated using Finite Element Analysis in accordance with
EN14509:2013 taking into account the profile geometry of the panel and the solution due to lack of cavities between steel deck and
thermal influence of the longitudinal joint. insulation.
 Covered under the Kingspan Warranty with a guarantee of
up to 20 years for thermal and structural performance.

2
Flat Roof Panel KS100 ERO Europanel Jumbo
Product Data Sheet

Available Lengths Acoustic Performance


Europanel Jumbo panels are available in standard lengths For sound transmission reduction, Kingspan panels typically
from 2 metres to 12 metres, subject to transport limitations have a single figure weighted sound reduction index (SRI)
and restrictions. Available lengths may change for export of Rw = 24dB.
(outside of Turkey).
Frequentie (Hz) 125 250 500 1000 2000 4000 Rw

Product Tolerances SRI (dB) 17 21 26 26 26 42 24

Length ≤ 3 m ± 5 mm
Length > 3 m ± 10 mm
Width ± 4 mm
Guarantee
Thickness > 100 mm ± 2 mm Kingspan will provide product guarantees on an individual
project basis. Guarantees are typically up to 5 years in a
Squareness of Panel Cut End ≤ 0,6%
non-marine / geothermal environment. All guarantees are
subject to maintenance regime.
Specialist coatings are available for marine and other more
Insulation Core corrosive areas.
QuadCore™ hybrid insulation foam is a thermosetting material.
It does not melt, flow or drip when exposed to fire. It forms
a strong char that helps protect the foam core and prevent Environmental Rating
flame spread within the panels. λ =0.018 W/m.K.
Europanel Jumbo panels are zero ODP (Ozone Depleting
Potential) and have a low GWP (Global Warming Potential.
Panels are CFC, HCFC and HFC-free, free from halogenated
flame retardants and 100% recyclable.

Materials & Coatings Quality and Durability


Europanel Jumbo panels are manufactured to
Internal Metal Sheet
ISO 9001 and TS EN 14509 standards from the highest
 Hot-dipped zinc coated steel according to EN 10346:2011. quality materials, using state-of-the-art production
Grade S350GD+Z275. equipment to rigorous quality control standards, ensuring
 Thickness: 0,9 mm long term reliability and service life.
 Coating: Kingspan PVDF 25μ.
External Metal Sheet Delivery and Packing
 Hot-dipped zinc coated steel according to EN 10346:2011.
Grade S250GD+Z275. Standard Packing
Protective film is applied to the external and internal face.
 Thickness: 0,7 mm Kingspan panels are stacked horizontally. The number of
 Profile: Box panels in each pack depends on panel thickness.
 Coating: Kingspan PES 25μ.
Core Thickness (mm) 100
External Membrane Options
Number of Panels in Pack 6
 Single-ply waterproof PVC membrane: 1,2 mm
 Single-ply waterproof TPO membrane: 1,5 mm Delivery
All deliveries (unless indicated otherwise) are by road
transport to project site by flat bed truck for off-loading by
crane or fork hoist. Off-loading is the responsibility of the
installer. Handling guidelines are available from Kingspan
Technical Services.

3
Flat Roof Panel KS100 ERO Europanel Jumbo
Product Data Sheet

KS100 ERO Europanel Jumbo


Load / Span Table

KS100 ERO Europanel Jumbo (100/825)


External sheet 0,7mm (steel), Internal sheet 0,9mm (steel).

Core Span Length (m)


Load Type
Span Thickness
(kN/m2)
(mm) 3,0 3,5 4,0 4,5 5,0 5,5 6,0 6,5 7,0

Pressure 6,74 5,17 4,13 3,29 2,55 1,97 1,55 1,25 1,02
Single 100
Suction -6,97 -5,52 -4,54 -3,66 -2,95 -2,43 -2,04 -1,74 -1,50
Pressure 6,74 5,17 4,13 3,29 2,55 1,97 1,55 1,25* 1,02*
Double 100
Suction -6,97 -5,52 -4,54 -3,83 -3,29 -2,86 -2,52 -2,25* -2,01*
Pressure 6,74 5,17 4,13 3,29* 2,55* 1,97* 1,55* 1,25* 1,02*
Triple 100
Suction -6,97 -5,52 -4,54 -3,83* -3,29* -2,86* -2,52* -2,25* -2,01*

1 Values have been calculated using the method described in BS EN 14509, for color group 1.
2 The following deflection limits have been used:
– Pressure loading L /200.
– Suction loading L /200.
3 The above-mentioned calculations apply to panels with standard steel skin strength specification:
– fy=350 MPa (S350GD) for the INTERNAL trapezoidal skin
– fy=250 MPa (S250GD) for the EXTERNAL skin with Box linear.
4 All panel thicknesses have been calculated with a minimum support width of 200 mm. Larger support widths are possible.
5 The actual wind suction resisted by the panel is dependent upon the number of fasteners.
6 The fastener calculation should be carried out in accordance with the appropriate standards. Kingspan recommends WKRET-MET KLIMAS
screws that have tight screw thread pitch. The actual span resisted by the panel is dependent on the number of fasteners. Each project must
be checked by Kingspan Technical Department Structural Engineer.
7 For intermediate values linear interpolation may be used.
8 The allowable steelwork tolerance between bearing planes of adjacent supports is ± 5mm.

* The mentioned spans are possible but the maximum length a single panel can be manufactured is defined by logistical limitations e.g. 11,95m
for containers. Contact Kingspan Customer Service for special length requirements.

4
Contact Details

TR
Kingspan Yapı Elemanları A.Ş.
Çırağan Cad. No: 97
Ortaköy 34347 Beşiktaş
Istanbul | Turkey

T: +90 (212) 236 60 32 (pbx)


E: info.turkey@kingspan.com
www.kingspanpanels.com

UAE
Kingspan Insulated Panels
Manufacturing LLC
P.O. Box 60493,
Dubai Investments Park,
Jebel Ali, Dubai, UAE

T: +971 (0) 4-8854 232


E: info@kingspanpanels.ae
www.kingspanpanels.ae

For the product offering in other markets please contact your


local sales representative or visit www.kingspanpanels.com
Care has been taken to ensure that the contents of this publication are accurate, but
Kingspan Limited and its subsidiary companies do not accept responsibility for errors
or for information that is found to be misleading. Suggestions for, or description of, the
end use or application of products or methods of working are for information only and
Kingspan Insulated Panels and its subsidiaries accept no liability in respect thereof.
® Kingspan is a Registered Trademark of the Kingspan Group plc in the UK, Ireland and
other countries. All rights reserved.

01/2021

You might also like