Features

 High quality, reliable and complete generating sets.


 4; generating set carries a comprehensive test program
Every
which includes 25%, 50%, 75%, 100% , 110% loading test and
series protecting function (example: Low oil pressure , High
coolant temperature, over current/load etc.) check.
 Easy for operation and maintenance.
 Compact structure &high-strength chassis.
 Base frame design incorporates an intergrade fuel tank for at
least 8 hours running (up to 650KVA).
 The canopy body painting adopts the HenKel pretreatment
process and the base frame painting adopts sandblasting
+AkzoNobel powder, the paint warranty period can be 3 years.
 High-performance free-maintenance batteries with isolation
switch.
 Anti- vibration pads are mounted between the engine/alternator
feet and the base frame.
 Top lifting point and steel base frame with forklift holes, easy for
transportation.
 Compliance with international electrical safety standards.
 Complete protection functions and safety labels.
 A large number of matching optional to meet the needs of
various customers.

SPECIFICATION OPEN TYPE SILENT TYPE


Engine Specifications
Model Genset PL – 70 L PL – 70 L
Engine model & manufacturer 1004TG
Power Output 70 Kva / 56 Kw 70 kva / 56 Kw
Number Of Cylinder 4 Vertical In – Line
Phase 3 ( Three) 3 ( Three)
Bore And Stroke 100.0 x 127.0 mm
Frequency 50 Hz @1500RPM 50 Hz @1500RPM Displacement 3.99 Litres

Voltage 220 / 380 V 220 / 380 V Aspiration Turbocharged


Fuel Tank, Residential
Fuel Tank, Residential Cycle 4 Stroke
Accessories Muffler, Batteries, Tools
Muffler, Batteries, Tools Kit
Kit
Cumbustion System Direct Injection
Dimension LxWxT 2000 x 900 x 1900 mm 2600 x 950 x 1600 mm
Compression Ratio 17.5 : 1
Weight 1136 Kg 1300 Kg
Rotation Anti – Clockwise, viewed on Flywheel
Fuel tank 140 98
Total Lubricating Capacity 8.5 Liter

Also available in the following voltages: Cooling System Water Cooled


415/240V, 380/220V, 220/127V, 200/115V (According to customer requirements).
Total Coolant Capacity 20.6 Litres
Rated Power/prime Power(PRP) :
Continuous running at variable load for unlimited periods with 10% overload available Fuel Consumption (L/H) 12.30(75% Load) / 16.40(100% Load)
for 1 hour in any 12 hour period, in accordance with ISO8528.
Standby Power/Emergency Standby Power (ESP):
The maximum power available during a variable electrical power sequence, no overload  Heavy duty Lovol diesel engine
on these ratings, in accordance with ISO 8528.  Four stroke, water cooled, Turbocharged aspirated
 Direct injection fuel system
 Electric governor system
 12V DC starter and charge alternator
 Replaceable fuel filter and dry element air filter
 Cooling radiator and fan
 Starter battery(with lead acid) including rack and cables
 Flexible fuel connection hoses
 Industrial capacity exhaust silencer and steel bellows
 Operation manuals and circuit diagram documents

Generator Silent Type Generator Open Type


Alternator Specifications
Alternator Manufacturer Powerline

Design Design Brushless Single Bearing, Revolving Field

Stator 2/3 Pitch

Rotor Single Bearing, Flexible Disc

Insulation System Class H

Standard Temperatur Rise 125 - 163°C Continous

Exciter Type Self Excited

Phase Rotation A (U), B (V), C (W)

Alternator Cooling Direct Drive Centrifugar Blower Fan

AC Waveform Total Harmonic Distortion No Load <1.5% Non Distorting Balanced Linear Load <5%

Telephone Influence Factor ( TIF ) <50 per NEMA MGI – 22.43

Telephone Harmonic Factor ( THF ) <2%

Control System

DSE4520 ( Deepsea ) DSE4620 ( Deepsea ) DSE7320 ( Deepsea )

Suitable for > 250KVA Gen - sets Suitable for for all series Gen - sets

The Controller Display DSE4520 Control System DSE7320 Control System


Voltage between phases(L-L) √ √
Voltage between neutral and phase(L-N) √ √
Frequency √ √
3 Phase current √ √
Real power(kW) and apparent power(kVA) √ √
Power factor √ √
Engine speed √ √
Running hours √ √
Coolant temperature √ √
Oil pressure √ √
Battery voltage √ √
LCD alarm indication √ √
3 Phase mains (utility) sensing √ √
Emergency stop button √ √
High coolant temperature √ √
Low oil pressure √ √
Over current/load √ √
under/over speed, frequency & voltage √ √
Low/High battery voltage √ √
Low coolant level √ √
Generating Set Type

Genset Type Silent Genset Type Trailer Genset Type Open

Panel ATS / Synchrone

Panel ATS
Panel Synchrone

Sparepart

Module ( Deepsea ) Switch Temperatur Switch Oli Switch Aki Filter Solar

Filter Oli Filter Oli Filter Udara Speed Control AVR

Baterai Charger Camp Shaft Ampere Dynamo Stater Dynamo Bearing Generator