TDL

Low Pressure Steam Boiler


1 2 5 4 12 3 14 9 8
K

140
NP

øM

C
R

D
øI

H
G

100

F
220

115
N L J E
16 15 13 10 17 A B
11

Design pressure 1 bar Type 1 2 3 4 5 6 7 8 9


Capacity max. kW 465 581 733 930 1163 1455 1860 2326 2907
Steam generation max. t/h 0,70 0,88 1,10 1,40 1,70 2,20 2,60 3,50 4,00
A mm 2780 2930 2930 3130 3680 4080 4030 4530 4680
B mm 1760 1760 1960 1960 1960 1960 2160 2160 2410
C mm 2110 1730 2285 2285 2285 2285 2560 2560 2840
D mm 1920 1920 2095 2095 2095 2095 2370 2370 2650
E mm 1110 1110 1295 1295 1295 1295 1360 1360 1475
F mm 925 925 941 941 941 941 1150 1150 1275
G mm 1045 1045 1110 1110 1110 1110 1295 1295 1443
H mm 2430 2580 2583 2783 3330 3730 3675 4175 4325
IØ mm 750 750 800 800 800 800 960 960 1050
J mm 615 615 615 615 615 615 615 615 615
K mm 591 591 615 615 615 615 710 710 774
L mm 1550 1700 1700 1900 2450 2850 2800 3300 3450
Ø
M mm 290 290 350 400 400 400 475 475 550
N mm 615 615 615 615 615 615 615 615 615
NP mm 2200 2350 2350 2550 3100 3500 3450 3950 4100
R mm 384 384 427 427 427 427 492 492 566
3
Water content for L.W. m 2,52 2,54 3,02 3,47 3,96 4,32 5,36 5,91 7,87
3
Steam chest m 0,81 0,86 1,30 1,43 1,67 1,81 1,90 2,18 2,77
3
Flue gas volume* m 1,35 1,50 1,95 1,90 2,40 2,80 3,80 4,40 5,22
Flue gas temp. * ºC 230 225 225 230 225 230 230 220 220
Flue gas resistance * mbar 5,5 5,5 4,5 7,0 5,5 5,5 4,5 7,5 8,0
Weight ton 2,21 2,65 3,06 3,30 3,77 4,15 5,13 5,7 7,8

1 Manometer DN 20 20 20 20 20 20 20 20 20
2 Air valve RG ½” ½” ½” ½” ½” ½” ½” ½” ½”
4 Steam valve DN 100 100 125 150 200 200 250 250 250
5 Water level control DN 100 100 100 100 100 100 100 100 100
7 Safety valves DN 2x32 2x32 2x40 2x40 2x50 2x50 2x65 2x65 2x65
8 Water gauge mount- RG ¾” ¾” ¾” ¾” ¾” ¾” ¾” ¾” ¾”
ings
9 Feed valve DN 25 50 50 50 50 50 50 50 50
10 Blow down valve DN 25 50 50 50 50 50 50 50 50
11 Head hole 220 x 320 mm 15 Inspection hole
12 Man hole 320 x 420 mm 16 Handling brackets
13 Access door (inspection) 17 Cleaning opening
* at natural gas, O 2 dry : 2,1%, 8,3 bar, The manufacturer reserves the right to make alterations. 06-09-10