Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Guara B.V.: Combined Heat Exchanger Hpu and After Coller Data Sheet (Diesel ENGINE) P-UH-B-UB-5420501A/B-01

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Nr:

DATA SHEET I-FD-3010.92-5420-456-SJA-002


GUARA CLIENT:
E&P SHEET:
1 of 4

B.V. PROGRAM:
PRESALT FPSOs – HULL _
AREA:
PETROBRAS 66 (P-66)
TITLE:
COMBINED HEAT EXCHANGER HPU AND CORPORATE
ENGENHARIA
IEEPT/IEPSA AFTER COLLER DATA SHEET (DIESEL
IEPSA
ENGINE) P-UH-B-UB-5420501A/B-01
SULZER NUMBER: TECHNICAL RESPONSIBLE: CREA NUMBER:

E4-154034-210 ANTONIO LUIS 4503565224


SULZER BRASIL S.A.
CONTRACT NUMBER: MAGNETIC ARCHIVE: MICROSOFT WORD 2000
35000000001.10.2 I-FD-3010.92-5420-456-SJA-002_F.doc

REVISION INDEX

REV. DESCRIPTION AND/OR REVISED SHEETS


0 ORIGINAL ISSUE / FOR APPROVAL
A DOCUMENT FOR COMMENTS ACCORDING TO ADF-00000-01197/66-93-0031
B DOCUMENT FOR COMMENTS
C FOR REVIEW
D DOCUMENT FOR COMMENTS ACCORDING TO ADF-00000-P01197/66-93-
0296_A
E FOR REVIEW
F DOCUMENT FOR WORKING OR CONSTRUCTION ACCORDING TO ADF-
00000-01197/66-93-0954.

SERVICE : FIRE FIGHTING PUMP


RM N°: I-RM-3010.92-5420-319-EGV-001
SERIAL Nr: OED Nr. TAG Nr. PUMP TYPE
154.033 A/B 261.758-01 B-UB-5420501A/B-01 BKn 450-450-1s/030
154.034 A/B 261.758-02 B-UB-5420501A/B-02 Z 400-490/61

REV. 0 REV. A REV. B REV. C REV. D REV. E REV. F REV. G REV. H


DATE 27/JUN/2011 30/AGO/2011 06/OUT/2011 20/DEZ/2011 04/JUN/2012 24/SET/2012 22/OUT/2012
PROJECT SJA SJA SJA SJA SJA SJA SJA
EXECUTION Leandro Barros Leandro Barros Leandro Barros Leandro Barros Leandro Barros Leandro Barros Leandro Barros
CHECK Álvaro Penteado Álvaro Penteado Álvaro Penteado Álvaro Penteado Álvaro Penteado Álvaro Penteado Álvaro Penteado
APPROVAL Carlos Lopes Carlos Lopes Carlos Lopes Carlos Lopes Carlos Lopes Carlos Lopes Carlos Lopes
THE INFORMATION CONTAINED IN THIS DOCUMENT IS PRETOBRAS PROPERTY AND MAY NOT BE USED FOR PURPOSES OTHER THAN SPECIFICALLY INDICATED HEREIN.

THIS FORM IS PART OF PETROBRAS N-381 REV.J ANNEX A – FIGURE A.1.


Nr: REV.
DATA SHEET I-FD-3010.92-5420-456-SJA-002 F
SHEET
PETROBRAS 66 (P-66) 2 of 4
GUARA TITLE:
B.V. COMBINED HEAT EXCHANGER HPU AND AFTER CORPORATE
COLLER DATA SHEET (DIESEL ENGINE)
IEPSA
P-UH-B-UB-5420501A/B-01

GEA ECOFLEX Plate Heat Exchanger: VT20 CDL-10


Thermal Data
Plate Type:
Frame Type:
Total Heat Transfer Area: 30,68 m²
Heat Recovery: 0,0 %
Number of Plates: 122
Frame Material: A 516 - 70
Surface: I-ET-3010.92-5420-956-SJA-001
Packet Length (total): 607 mm
Max. Packet Length Frame: 700 mm
Max. Packet Length Bolts: 651 mm
Weight (Gross): 643 kg
Weight (Net): 525 kg
Numbers Of Sections: 2
Number Of Intermediate / Reinforcement 1 0
Plates::
Design Temperature: 100,00 °C
Working Pressure: 6,86 bar
Test Pressure: 8,92 bar
Nr: REV.
DATA SHEET I-FD-3010.92-5420-456-SJA-002 F
SHEET
PETROBRAS 66 (P-66) 3 of 4
GUARA TITLE:
B.V. COMBINED HEAT EXCHANGER HPU AND AFTER CORPORATE
COLLER DATA SHEET (DIESEL ENGINE)
IEPSA
P-UH-B-UB-5420501A/B-01

Section Specification

Section: HPU VT20 H L Titanium 0.6 NBR Loc-In glueless


Calculation Data:
Thermal Data: Warm Side Cold Side
Media: ISO VG 46 Sea Water
Media group acc. PED Group 2 - others Group 1 - dangerous
97/23/EC:
Heat Exchanged: 150,00 kW
Mass flow: 14394 25435 kg/h
Volume flow: 16,80 25,00 m³/h
Temperature Inlet: 60,00 31,70 °C
Temperature Outlet: 41,04 36,78 °C
Pressure Drop: 1,50 0,09 bar
Working Pressure Inlet:: 6,00 5,60 barg
Product properties
Density: 856,74 1017,41 kg/m³
Heat Capacity: 1978,24 4180,00 J/kgK
Thermal Conductivity: 0,12847 0,62214 W/mK
Dyn. Viscosity Inlet: 17,614 0,775 cP
Dyn. Viscosity Outlet: 38,122 0,701 cP
Unit Data
Plate Type VT20 H L
Heat Transfer Area: 15,34 m²
No. Of Plates: 61
Plate Thickness: 0,60 mm
Plate Material: Titanium
Gasket Material: NBR
Gasket Type: glueless
Internal Flow (Passes x 3 x 10 1 x 30
Channels)

Remarks:
Nr: REV.
DATA SHEET I-FD-3010.92-5420-456-SJA-002 F
SHEET
PETROBRAS 66 (P-66) 4 of 4
GUARA TITLE:
B.V. COMBINED HEAT EXCHANGER HPU AND AFTER CORPORATE
COLLER DATA SHEET (DIESEL ENGINE)
IEPSA
P-UH-B-UB-5420501A/B-01

Section Specification

Section: AFTER COOLER VT20 H L Titanium 0.6 NBR Loc-In glueless


Calculation Data:
Thermal Data: Warm Side Cold Side
Media: Água Refrigeração Sea Water
Media group acc. PED Group 2 - others Group 1 - dangerous
97/23/EC:
Heat Exchanged: 473,56 kW
Mass flow: 22725 25386 kg/h
Volume flow: 23,00 25,00 m³/h
Temperature Inlet: 56,00 31,70 °C
Temperature Outlet: 38,00 47,77 °C
Pressure Drop: 0,07 0,06 bar
Working Pressure Inlet:: 3,00 5,15 barg
Product properties
Density: 988,05 1015,41 kg/m³
Heat Capacity: 4167,66 4180,00 J/kgK
Thermal Conductivity: 0,64013 0,63024 W/mK
Dyn. Viscosity Inlet: 0,494 0,775 cP
Dyn. Viscosity Outlet: 0,677 0,570 cP
Unit Data
Plate Type VT20 H L
Heat Transfer Area: 15,34 m²
No. Of Plates: 61
Plate Thickness: 0,60 mm
Plate Material: Titanium
Gasket Material: NBR
Gasket Type: glueless
Internal Flow (Passes x 1 x 30 1 x 30
Channels)

You might also like