SEWAGE PUMPS

MYERS MW SERIES
®

The Myers® MW series sewage


pumps are designed for light
commercial and residential raw
sewage applications. The enclosed
two-vane impeller provides high-
efficiency pumping and will easily
handle stringy, trashy 2” solids
without clogging. The heavy-duty
cast iron construction ensures
years of service in demanding
applications. Available in single-
and double seal models; cast
iron and optional bronze impeller
models.

applications features

Sewage, high-capacity sump, effluent Cast Iron Tough Guards Against Leaks
All cast-iron housing and volute case Optional leak probe senses water
stand tough against extremely leakage past seal (dual seal motors
specifications corrosive environments only)
Capacities – Up to 165 GPM (624 LPM) No Jamming Prevents Overheating
Shut-off Head – Up to 70’ (21.3 m) Enclosed impeller design eliminates Heat sensor overload protection with
Solids Handling – 2” (50.8 mm) jamming between impeller and volute automatic reset when
Liquids Handling – Domestic sewage and – cast iron or bronze (optional) motor cools to a safe operating
drain water temperature (single phase only)
Powerful Starts
Intermittent Liquid Temperature – High-torque, permanent split Easy Service
Up to 140°F (60°C) capacitor (PSC) motor; no starting Remove only four screws for
Motor/Electrical Data – 1/2 to 2 HP, switches or relays to wear out motor access; volute seal ring is
208/230V, 1Ø; 208/230/460/575V, 3Ø, replaceable
Motor Protection
oil-filled, permanent split, capacitor type, Rugged, oil-filled motor for
1Ø, 3450 RPM, 60Hz bearing lubrication and maximum
Acceptable pH Range – 5-9 heat dissipation
Discharge, NPT – 2” (50.8 mm)
Housing – Cast iron
Power Cord – 20’
Impeller – Ductile iron; bronze (optional)
available on double seal models –
consult Factory
Volute Case – Class 30 cast iron
Shaft Seal – Type 21, carbon and ceramic
Minimum Sump Diameter –
Simplex: 24” (61 cm)
Duplex: 36” (91.4 cm)

1
SEWAGE PUMPS

MYERS MW SERIES
®

ordering information

Approx.
Catalog Phase/ Discharge Switch Cord Wt.
Number HP Volts Cycles Size Type Length Lbs.
SINGLE SEAL
MWH50-01 1/2 200 1/60 2” Manual 20’ 84
MWH50-01P 1/2 200 1/60 2” Automatic* 20’ 84
MWH50-21 1/2 230 1/60 2” Manual 20’ 84
MWH50-21P 1/2 230 1/60 2” Automatic* 20’ 84
MWH50-03 1/2 200 3/60 2” Manual 20’ 84
MWH50-23 1/2 230 3/60 2” Manual 20’ 84
MWH50-43 1/2 460 3/60 2” Manual 20’ 84
MWH50-53 1/2 575 3/60 2” Manual 20’ 84
MW100-01 1 200 1/60 2” Manual 20’ 86
MW100-21 1 230 1/60 2” Manual 20’ 86
MW100-03 1 200 3/60 2” Manual 20’ 86
MW100-23 1 230 3/60 2” Manual 20’ 86
MW100-43 1 460 3/60 2” Manual 20’ 86
MW100-53 1 575 3/60 2” Manual 20’ 86
MW150-01 1-1/2 200 1/60 2” Manual 20’ 87
MW150-21 1-1/2 230 1/60 2” Manual 20’ 87
MW150-03 1-1/2 200 3/60 2” Manual 20’ 87
MW150-23 1-1/2 230 3/60 2” Manual 20’ 87
MW150-43 1-1/2 460 3/60 2” Manual 20’ 87
MW150-53 1-1/2 575 3/60 2” Manual 20’ 87
MW200-01 2 200 1/60 2” Manual 20’ 88
MW200-21 2 230 1/60 2” Manual 20’ 88
MW200-03 2 200 3/60 2” Manual 20’ 88
MW200-23 2 230 3/60 2” Manual 20’ 88
MW200-43 2 460 3/60 2” Manual 20’ 88
MW200-53 2 575 3/60 2” Manual 20’ 88
*Piggyback
Note: Consult factory for Double Seal models

2
SEWAGE PUMPS

MYERS MW SERIES
®

DIMENSIONS PUMP PERFORMANCE

Capacity liters per minute


0 100 200 300 400 500 600

80 24

20

60
MW

Total head in meters


200 16

Total head in feet


2H
MW P
150
1-1/
2HP
40 12
MW
100
1HP
MW
H50 8
1/2
HP
20

4
Single Seal

0 0
0 25 50 75 100 125 150 175
Capacity gallons per minute

Double Seal

3
SEWAGE PUMPS

MYERS MW SERIES
®

SPECIFICATIONS

Sewage Pumps – Pump(s) shall be F. E. Myers MW series single/double seal sewage pumps selected in accordance with the
following design criteria:
Number of Pumps: _____________________ Motor Horsepower: _____________________
Primary Design Flow: _____________________ Motor Speed: 3450 RPM
Primary Design Head: _____________________ Electrical: _____________________
Minimum Shut-off Head: _____________________
Pump – The pump shall be designed to handle raw sewage and be capable of passing 2 inch spherical solids. The pump shall be
capable of handling liquids with temperatures to 140°F intermittent and shall be capable of running dry without damage to the seals
or bearings.
Motor – The pump motor shall be of the submersible type rated 1/2, 1, 1-1/2 or 2 hp as required. Motor shall operate at 3450 RPM
and shall be for 208 or 230 volts single phase, or 200, 230, 460, or 575 volts, 3 phase, 60 cycles. Single phase motors shall be of the
permanent split capacitor type with no relays or starting switches. Three phase motors shall be squirrel cage induction type. Stator
winding shall be of the open type with Class B insulation rated for 130°C maximum operating temperature. The winding housing will
be filled with clean dielectric oil to lubricate bearings, seals, and transfer heat from the windings to the outer shell. The motor
assembly shall be of the standard frame design and shall be secured in place by four threaded fasteners allowing for easy field
serviceability.
The motor shall be capable of operating over the full range of the performance curve without overloading the motor and causing any
objectionable noise or vibration. The common motor pump shaft shall be of 416 stainless steel and shall be heat shrunk into the die
cast motor rotor. The motor shall have two bearings to support the rotor; an upper ball bearing to accommodate radial loads and a
lower ball bearing to take thrust and radial loads. Ball bearings shall be designed for a B-10 life of 50,000 hours.
A heat sensor thermostat and overload shall be attached to the top end of the motor windings and shall be wired in series with the
windings to stop the motor if the motor winding temperature reaches 266°F. The overload thermostat shall reset automatically when
the motor cools to a safe operating temperature. Three phase motors shall be protected by 3 leg overload relay in control box.
Overload shall be of the quick trip ambient compensated type and shall have manual reset button.
Power Cord – The motor power cord shall be SOOW. The cable jacket shall be sealed at the motor entrance by means of a rubber
compression washer and compression nut. A heat shrink tube filled with epoxy shall seal the outer cable jacket and the individual
leads to prevent water from entering the motor housing.
Shaft Seal (Single Seal) – The motor shall be protected by a rotating mechanical shaft seal. The seal shall have carbon and ceramic
seal faces lapped to a tolerance of one light band. Metal parts and springs for seals shall be 300 series stainless steel.
Shaft Seal (Double Seal) – The motor shall be protected by two (2) rotating mechanical shaft seals mounted in tandem with an oil
filled chamber separating the seals. The seals shall have carbon and ceramic seal faces lapped to a tolerance of one light band.
Metal parts and springs for seals shall be 300 series stainless steel. Two electrical sensing probes shall be mounted in the seal
chamber to detect any water leakage past the lower seal. The sensing probes shall be connected to a red warning light in the control
panel. The warning light shall serve to indicate a seal leak condition and shall not stop the pump.
Pump Impeller – The pump impeller shall be of the two vane enclosed type. The impeller shall be constructed of ductile iron or
optional bronze. A replaceable Buna-N sealing cup shall effect a seal between the volute and impeller in order to maintain high
efficiency and prevent recirculation. The impeller shall be threaded onto the 416 stainless steel pump/motor shaft.
Pump and Motor Castings – All castings shall be of high tensile strength Class 30 gray cast iron. Castings shall be treated with
phosphate rinse and painted with a high quality air dry alkyd enamel.
Fasteners – All exposed fasteners shall be of 300 series stainless steel.

USA CANADA
293 Wright Street, Delavan, WI 53115 WWW.FEMEYERS.COM 269 Trillium Drive, Kitchener, Ontario, Canada N2G 4W5
PH: 888-987-8677 ORDERS FAX: 800-426-9446 PH: 519-606-5484 ORDERS FAX: 800-426-9446

Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.

© 2012 Pentair Ltd. All Rights Reserved. 4 M9032SSE (12/20/12)

You might also like