CPP 3000 B
CPP 3000 B
CPP 3000 B
WARNING
This pump is not designed for
pumping petrol, paraffin or other
flammable or acid based liquids.
Safety Precautions
• DO NOT allow the pump to run dry.
• DO NOT operate at speeds greater than
3,000RPM.
Thank you for purchasing this CLARKE Drill • DO NOT pump liquids contaminated with
Powered Pump. solids, without a filter being fitted to the inlet
This extremely versatile pump is designed for hose.
use in the home for pumping flooded cellars, • In addition to petrol or other flammable liquids,
emptying fish tanks, blocked sinks, baths or and acids, or DO NOT pump liquids that leave
washing machines, in the garden for emptying a residue upon drying.
ponds, or paddling pools, irrigation or transferring
• ALWAYS keep your feet and hands dry when
insecticides, on boats for emptying bilge water
using the drill pump.
etc., and in any operation requiring the transfer of
liquids other than petrol and other flammable • ALWAYS ensure the drill is kept dry and is
substances, (see Safety Precautions). correctly earthed - preferably use a drill which
is double insulated.
The pump is simple to use, but you should never-
theless read this leaflet thoroughly and follow the • Make absolutely sure that there is no
instructions carefully. In doing so you will ensure possibility of the pump and drill vibrating its
the safety of yourself and that of others around way into the liquid.
you, and you can look forward to the pump giving • As the device is to be used in the close
you long and satisfactory service. proximity to water, the drill should always be
connected to the mains supply through a
Guarantee residual current circuit breaker (RCCB or
RCD).
This CLARKE product is guaranteed against
faulty manufacture for a period of 12 months from Contents List
the date of purchase. Please keep your receipt
as proof of purchase. This guarantee is invalid if 1. Pump Body
the product is found to have been abused or
tampered with in any way, or not used for the 2. ‘U’ Bolt w/washers and nuts
purpose for which it was intended. 3. Gauze Filter
Faulty goods should be returned to their place of 4. 4 x replacement Vane Seals
purchase. No product can be returned to us 4. ‘O’ Ring
without prior permission. This guarantee does
not affect your statutory rights.
Parts & Service: 020 8988 7400/E-mail:Parts@clarkeinternational.com or Service@clarkeinternational.com
Instructions for use Ensure also that the outlet hose is led away to
a suitable place of discharge. If a long hose is
1. Attach suitable 3/4” dia hose to the inlet and used, ensure that there is no likelihood of it
outlet ports using worm drive clips, (not becoming damaged or blocked by vehicles or
supplied), ensuring they are completely air other means. The maximum height to which
tight. The inlet port is marked ‘IN’ and the outlet the pump will deliver water is 15 metres.
port ‘OUT’.The inlet hose be completely sound
with no pin holes. Test it prior to use by 4. When installation is complete, plug the drill into
the mains supply and switch on.
blocking off one end and blowing into it.
Always attach the filter (provided), to the foot of NOTE: If the pump does not prime and begin to
the hose, as shown in the diagram. Use a deliver liquid within 10 seconds, switch off and
suitable adhesive (not supplied) to ensure it is investigate the cause.
firmly and permanently attached. The most common cause is leaks on the inlet side
of the pump, is where air is being drawn in through
a damaged or insecure hose.
Other causes are - blocked inlet or outlet pipes,
trying to draw from too great a height (2M max.),
or deliver to too great a height (15M max.), drill
power too low, or worn pump seals.
WARNING:‘The outlet flow from this pump must
2. Install the pump in the chuck of a suitable drill, not be restricted in any way either during or prior
with the drill disconnected from the mains
supply. to use’.
Do not connect the outlet of this pump to a system
NOTE: While the pump can be held by hand
that restricts its flow or has a head height greater
during fairly short periods of operation, for extra
than 1.5 metres.
stability it is advised that the pump be attached to
Maintenance
To prolong the life of the pump, always flush
thoroughly with a water/detergent solution and
‘U’ bolt then with water only. Finally, apply a few drops of
light lubricating oil into the inlet port, rotating the
worm drive drive shaft by hand as you do so.
clip
Store in a dry cool location. Do not leave exposed
to the elements.
Four vane seals, together with an end plate ‘O’
Ring and a shaft seal, are provided should the
pump require servicing.
drill board
To replace the vane seals, remove the four
screws securing the end cover, - at the SHAFT
end of the pump, and withdraw the shaft complete
a board using the ‘U’ bolt supplied, as shown in with vanes from the pump body.
the diagram. If necessary weigh the board down Pull out the vane seals and replace with new
or secure it in some way to prevent it from ones.
moving during operation.
Renew the large ‘O’ ring on the inside face of the
When securing the pump to a board, ensure the end cover and apply silicon grease to the vanes,
pump and drill remain perfectly in line. Do not ensuring they are perfectly free to move, before
under any circumstances tighten down the ‘U’ reassembly.
bolt in such a way as to cause the pump and drill
to become ‘bowed’. The drill should be free to Before fitting the four end cover screws, twist the
move but have its weight supported, keeping it end plate whilst applying gentle pressure, to
perfectly in line with the pump. ensure the locating dowels seat correctly.
3. Insert the inlet hose into the liquid with the Tighten the four end cover screws progressively,
pump as near to it as possible bearing in mind taking care not to vertighten them as this could
that the maximum lifting height is 2 metres. distort the body of the pump and cause severe
damage, possibly rendering the pump inoperable.
Parts & Service: 020 8988 7400/E-mail:Parts@clarkeinternational.com or Service@clarkeinternational.com