PLUMBING
PLUMBING
PLUMBING
A B C A B C
6.00 6.00
3.00 3.00 3.00 3.00
2.00
ELEV. +0.40m
ELEV. +0.40m T&B
W2
20 mm CWL
3.00
3.00
F
W6
BEDROOM 1 D3
3.70
W4
ELEV. +3.40m
4.60
5.00
5.00
5.00
D2 D4
1.70
2 20 mm CWL
2 25mm GV LAV.
STORAGE
32 mm CWL R
W3
1.60
TOILET
2.00
W8
DN
D3 T&B
D3
10.00
10.00
10.00
10.00
3.30
A A
2.40
2.00
2.00
D2
BEDROOM 2
W7
UP
AREA
6.30
3 ELEV. +0.40m
3
5.40
D2 D2
5.00
5.00
1.00
W5
D1
1.80
W1 BEDROOM 3
3.00
3.00
W1
RECREATIONAL D5 ELEV. +3.40m
PORCH ROOM D3
2.00
1.20
BALCONY
ELEV. +3.40m
4 ELEV. +0.20m
W2
4 W2
C.V.
M
G.V.
FROM WATER
LINE SOURCE
DRAWINGS AND SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS DULY SIGNED, INSTRUCTOR: PROJECT TITLE: NAME OF STUDENTS: SHEET CONTENTS: REVISIONS: NOTE: SHEET NUMBER:
STAMPED OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY
AND DOCUMENTS OF THE ARCHITECT, WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS
EXECUTED OR NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE
PROPOSED TWO STOREY BACALANDO, VICTOR JOSEPH E.
COPIES OF THE SAID DOCUMENTS IN PART OR IN WHOLE OR USE IN REPETITION OF AND
FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT
THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF THE SAID DOCUMENTS.
SEC. 33, RA 9266
ENGR. JOBEL HYLES CABAHUG RESIDENTIAL BUILDING
LOCATION:
NAMUCO, JERICO P.
RUÑA, MICHAEL L.
AS SHOWN
DATE:
P-1
NOTE: DRAWINGS MUST NOT BE SCALED FOR CONSTRUCTION.
B B
A B C A B C
S 6.00 6.00
3.00 3.00 3.00 3.00
OUTLET
SEPTIC
100 mm PVC S P UG
TANK
INLET
FCO FCO
INLET
1 SSP 1 FCO
50 mm PVC W P
SSP
UG
LAV.
UG
WC
2.00
P
T&B
3.00
F
PVC S
PVC S
3.70
5.00
5.00
5.00
100 mm
100 mm
1.70
2 SSP
FCO 50 mm PVC W P 2 SSP
50 mm PVC W P
LAV.
FCO
LAV. FD
WC FCO
WC
TOILET
2.00
DN
T&B
10.00
10.00
10.00
3.30
PVC P
A A
2.00
2.00
100 mm
UP
6.30
3 3
5.00
5.00
1.00
1.80
3.00
2.00
1.20
4 ELEV. +0.20m 4
3.00 3.00
6.00
TO PUBLIC
SEWER LINE 1 GROUND FLOOR SANITARY PLAN 2 SECOND FLOOR SANITARY PLAN
P 2 SCALE 1:100 MTS. P 2 SCALE 1:100 MTS.
DRAWINGS AND SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS DULY SIGNED, INSTRUCTOR: PROJECT TITLE: NAME OF STUDENTS: SHEET CONTENTS: REVISIONS: NOTE: SHEET NUMBER:
STAMPED OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY
AND DOCUMENTS OF THE ARCHITECT, WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS
EXECUTED OR NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE
PROPOSED TWO STOREY BACALANDO, VICTOR JOSEPH E.
COPIES OF THE SAID DOCUMENTS IN PART OR IN WHOLE OR USE IN REPETITION OF AND
FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT
THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF THE SAID DOCUMENTS.
SEC. 33, RA 9266
ENGR. JOBEL HYLES CABAHUG RESIDENTIAL BUILDING
LOCATION:
NAMUCO, JERICO P.
RUÑA, MICHAEL L.
AS SHOWN
DATE:
P-2
NOTE: DRAWINGS MUST NOT BE SCALED FOR CONSTRUCTION.
1 A
B
2 B
A 0
5.0 .00 DIN
32
mm
3.0
0
6.0
5 PP 0
EL I RP
EV NG N
.+ 20
0.4AR
3 10
.00 32
mm
0mEA CW
LU
G
3.0
0 C
CW
2.0
0 LR ELK
EVITC
. + HE
0 0.4 N
4 5.0 .00
1
L
ELEAR IVIN LA
0m
20
F mm
32
mm
0 V. EA G V . CW CW
2.0 +0
.40
m
TO
ILE WC
20
mm L LR
1 A
ELEPO
V. RC
+0 H
T CW
L B
ELE
V.
.40
m
UP
2 B
3.0
0
+0
.2 0m RE
CR
ELE RO EA
A 5.0
0
3.
00
3.0
0
6.0
V. O TIO 0
+0 M N 25
6.0 .40 AL mm BE
0 m
3 10
.0
0 2.0
0
GV
25
ELE DR
V. O
+3 O
.40M LA
3.0
0 C
mm m 1 V.
25
0 CW mm
2.0 WC
L L T&B WC
T&B A V. CW
.00
M C.V
.
4 5
1.8
0 BE
ELEDR
L
2525m
mm m
G. V. O GV
LINFROM V. 20
+3 O
.40M 2.0
0 CW
LR
ES W 1. m 2 DN
OU AT 3.7
0
RC ER 0
E B 1.7
E A
LEV LC
.+ O
3.4NY
0m BE
3.0 ELE DR 0
0 V. O 3.3 .00
+3 O 10
.40M
3
1 GROUND FLOOR ISOMETRIC WATERLINE SYSTEM
m
6.0 0
0 6.3
DATE:
P-3
NOTE: DRAWINGS MUST NOT BE SCALED FOR CONSTRUCTION.
T
TLE S
1 OU
A
PT
SETANK
IC
I
INL NLET
B
2 E
U TG FCO
B
A 0
5.0 .00 PV
C S
P
10
3.0
0m
0
CP m 6.0
5 0
PV m PV
0m CS
m 1S0
10
0m
3 10
.00 SP P
UG
3.0
0 C
0
2.0
00 F
4 5. .00
1 FC
O
5 P
SSU GCO
P
LA0 mm
CS
0 V.
2.0
TO PV
C PV
SETO P ILE WC W mm
WE UB T P 0
R L LIC FC 10
O
INE ELE UP
V.
+0
3.0
.20
0 m
1 A
6.0
0
3.0
B
00
2
0
3.
A 3.
00
3.0
0 B
0
5.0 6.0
0
3 10
.0
0 2.0
0 SS
P 50
FC
O
LA
3.0
0 C
mm V. 50 m
PV m
0 CW PV
1 GROUND FLOOR ISOMETRIC SANITARY PLAN 2.0 T&B
WC WC CW
FD
T&B LA
V. PF
.00
P 4 SCALE 1:100 MTS.
4 5
1.8
0
CO P
SS
P
0
0 2.0
1.2 DN
70
3.
0
1.7
3.0 0
0 3.3 .00
10
6.0 0
0 6.3
3.0
00
0 3.
DATE:
P-4
NOTE: DRAWINGS MUST NOT BE SCALED FOR CONSTRUCTION.
GENERAL PLUMBING NOTES : MATERIAL SPECIFICATION : LEGEND:
1. ALL PLUMBING WORKS HEREIN SHALL BE EXECUTED ACCORDING TO THE REQUIREMENTS COLD WATER LINE WATER SUPPLY LINE
OF PHILIPPINE NATIONAL PLUMBING CODE AND THE RULES AND REGULATIONS OF THE BT BATH TUB SANITARY LINE
EXISTING LOCAL CODES AND ORDINANCES. NOTHING CONTAINED ON THE DRAWING SHALL ALL RISER & DISTRIBUTION LINES FOR POTABLE WATER SUPPLY SHALL BE CO CLEAN OUT 75mmØ WASTE LINE
BE CONSTRUCTED AS TO CONFLICT WITH THE NATIONAL AND LOCAL ORDINANCES OR LAWS POLYPROPYLENE (PPR) PIPE; BUGATTI BRAND UNLESS OTHERWISE SPECIFIED. 50mmØ VENT LINE
GOVERNING THE IMPLEMENTATION OF THE PLUMBING WORKS. ALL RISER & DISTRIBUTION LINES FOR NON-POTABLE WATER SUPPLY SHALL BE
CB CATCH BASIN M WATER METER
POLYPROPYLENE (PPR) PIPE; BUGATTI BRAND UNLESS OTHERWISE SPECIFIED. CCO CEILING CLEAN OUT GATE VALVE
2. REFER TO ALL ELECTRICAL, STRUCTURAL AND ARCHITECTURAL PLANS AND
SPECIFICATIONS AND INVESTIGATE ALL POSSIBLE INTERFERENCE AND CONDITIONS CV CHECK VALVE CHECK VALVE
INCREASER LAVATORY
50mmØ VENT
AIR CHAMBER AIR CHAMBER
BRACKET 100MMØ PVC
100MMØ PVC P-TRAP
12mmØ CWL PVC DRAIN PIPE
150
BEND
25mmØ CWL 25mmØ CWL P-TRAP CHANGE OF FLOOR DRAIN DETAIL
WALL CLEAN-OUT DETAIL HORIZONTAL DIRECTION
CO CHB WALL OR
50mmØ VENT 50mmØ VENT
PARTITION FIN. FLR. 50mmØ VENT THRU ROOF
FINISH FLOOR
RC. SLAB
1/8 BEND
PVC WYE
DATE:
P-5
NOTE: DRAWINGS MUST NOT BE SCALED FOR CONSTRUCTION.