AT1K Series: Auto Transfer Switch Controller

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

SEDEMAC

AT1K Series
Auto Transfer Switch Controller

HIGHLIGHTS
Automatic & Manual switching between
the supplies

Offers single phase & three phase


power monitoring with control

Immediate phase reversal detection

Offers "Auto exercise mode" to start and


stop the genset

Configurable via SEDEMAC's


configuration utility
AT1K Series
Back-lit and full graphics display with
power saving feature

SEDEMAC’s AT1K Series controller is an It is provided with immediate phase reversal


automatic transfer switch controller with user detection feature with configurable action.
friendly interface and controls.
The device has an USB (Type-B) port that
In auto mode, ATS controller monitors voltage empowers it to communicate with SEDEMAC's
and frequency of incoming AC supply from proprietary Microsoft Windows based utility
two different sources namely S1 (Mains) and
S2 (Genset). In event of S1 failure, it issues a MODBUS over RS485 is provided for
start command to S2 and transfer load on it. supporting the remote communication.
When S1 is available again, the controller Various timers are available which ensure
restores the load back to S1. precise switching among sources by
In manual mode, the controller allows distinguishing between actual failure and
the operator to manually control the transfer momentary transients.
of load using transfer keys available on
front facia.

www.sedemac.com
SEDEMAC

AT1K Series
SCHEMATIC

www.sedemac.com
FEATURES SPECIFICATIONS

 Full graphics back-lit LCD display with power save mode Environmental Testing Standards
 Monitors 1ph/3ph voltage, frequency & load current for mains Operating/Storage temperature
and generator; monitors 1ph/3ph power factor for generator -30˚C to 65˚C as per IEC 60068-2-1, 2
Vibration
 Offers automatic & manual modes of operation 2G in X, Y and Z for 8-500 Hz as per IEC 60068-2-6
Humidity
 Offers "Auto exercise mode" (16 events) to start and stop the 0 to 95% RH as per IEC 60068-2-78
genset for preconfigured time EMI/EMC
Compliance as per IEC 61000-6-2, 4
 Versatile software capable of saving "events" during operation; Power Supply
event log for 100 events with real time clock (RTC) stamps and 8V- 32V continuous
engine run hour information Ingress Protection
IP65 for front face with optional gasket as per IEC 60529
 Totalizers for engine starts, running hours, Shock
kWh, kVAh, etc. 15 g for ms, compliance as per IEC 60068-2-27

 Offers multiple level passwords to avoid tampering in the


configuration Technical
 Access to each parameter through PC Software or control keys Power Consumption
~0.08A @ 12V or 24V DC (Standby mode)
on front fascia of AT1K series controller
Crank-start Dropout Survival Period
 Immediate phase reversal detection with configurable action 50 mS for a drop from 12V DC
Digital Output
 LED indications for load & supply status 7 x 0.75A high-side drivers configurable outputs
Digital Input
 Communicates with PC via configuration utility through a 9 switch-to-ground configurable inputs
USB port
Mains / Genset Voltage Measurement
 Higher number of configurable inputs (9) and outputs (7) make 20V–385V AC RMS @ 3–75 Hz for Ph to N
it fully flexible to suit a wide variety of applications. Load Current Measurement
0A - 5A AC RMS for current transformer (CT) secondary
Dimensions
External dimensions: 139 mm x 114 mm x 37.5 mm
Mounting panel cut: 118 mm x 93 mm

Ordering Information:
AT1K Series Controller .…………………………………………. SM0005298

SEDEMAC GENSET CONTROLS

Genset Controllers Electronic Governors ATS Controllers LiveTronics Ba ery Chargers

SEDEMAC MECHATRONICS PVT LTD


Local Partner
C 9-10, C Block, MIDC Bhosari
PDS/AT1000/004/JAN17

Pune 411026, INDIA


Phone: +91 20 67313500
Email: sales@sedemac.com
www.sedemac.com